N236AA
1984 McDonnell Douglas DC-9-82(MD-82) standard FAA →
reservations
earlier registrations
1 past record
- 1984
NTSB
- 8 Mar 1987
incident, Baltimore MD
service difficulty reports
34 reports
- 2 Oct 2008
Duct, leaking
DFW - CREW REPORTED TAIL COMPARTMENT OVERHEAT INDICATION DURING CLIMBOUT. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED WATER SEPARATOR DUCT ASSEMBLY.…
- 1 Sep 2008
Oxygen Mask, failed
DFW INFLIGHT T323/01SEP. DURING DESCENT THROUGH FL110 PRESSURIZATION FLOW LIGHT ILLUMINATED. OXYGEN MASKS WERE DEPLOYED AND CREW REPORTED ELECTRICAL SMELL.…
- 7 Jul 2008
Battery Pack, discharged
LGA - EXTERIOR EMERGENCY LIGHTS AT AFT CARGO INOPERATIVE. REPLACED BATTERY PACK FOR EXTERIOR EMERGENCY LIGHTS AT AFT CARGO. SYSTEM GROUND CHECKED NORMAL…
- 29 Aug 2007
Blades, damaged
SJC INFLIGHT T2426/29AUG - BIRD STRIKE ON NUMBER TWO ENGINE DURING CLIMB. CREW REPORTED ODOR AFTER BIRD STRIKE. RETURNED TO SJC AND LANDED WITHOUT INCIDENT.…
- 13 Jun 2006
Battery Pack, discharged
LGA - OVERHEAD EMERGENCY LIGHTS FROM ROWS 8 THROUGH 11 INOPERATIVE. REPLACED BATTERY PACK B5101 FOR INOPERATIVE OVERHEAD EMERGENCY LIGHTS FROM ROWS 8 TO 11.…
- 4 Jun 2006
Outflow Valve, separated
TUL INFLIGHT AIRCRAFT LOST CABIN PRESSURE AT 28,000 FEET. OXYGEN MASKS DEPLOYED. RETURNED TO TUL AND LANDED WITHOUT INCIDENT. FOUND OUTFLOW VALVE DOOR…
- 29 Mar 2006
Battery Pack, inoperative
DFW - EMERGENCY LIGHT BATTERY PACK EQUIPMENT 3BS101 INOPERATIVE. REPLACED BATTERY PACK 3BS101 FOR EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 21 Dec 2003
Socket, shorted
EMERGENCY LIGHTS FROM ROWS 21-31 INOPERATIVE. REPLACED SOCKET IN ROW 30. SYSTEM GROUND CHECKED, NORMAL OPERATION.
- 3 Dec 2003
Switch, failed
DFW T9602/03 EN ROUTE MSY-DFW NOSE GEAR DID NOT RETRACT. RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED LANDING GEAR HANDLE SWITCH AND RESERVICED NOSE…
- 11 Sep 2003
Battery Pack, discharged
DEN - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTING INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 2 Jun 2003
Socket, inoperative
FOUND DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING AT SEAT 7D INOPERATIVE. REPLACED AFT EMERGENCY EXIT PATH LIGHT SOCKETS AT 7D. SYSTEM GROUND…
- 12 Feb 2003
Frame, cracked
TUL - FOUND FS 1485 CANT FRAME CRACKED, TOP LEFT AFT SIDE. INSTALLED DOUBLER ON FRAME PER AARD 53-10-00-32. (M)
- 4 Feb 2003
Bulkhead, cracked
TUL - FOUND AFT PRESSURE BULKHEAD UPPER RIGHT FS 1338, CRACKED. REMOVED AND REPLACED. (M)
- 4 Feb 2003
Shear Tie, cracked
TUL - FOUND SHEAR TIE CRACKED ABOVE LONGERON 16L STATION 1309. REPLACED SHEAR TIE WITH NEW PART SRM 51-20-00. (M)
- 4 Feb 2003
Longeron, cracked
TUL - FOUND CRACKED LONGERON 10L AT STATION 1271. INSTALLED DOUBLER SPLICE PER SRM 50-02-00 ON LONGERON 10L. (M)
- 30 Jan 2003
Frame, cracked
TUL - FOUND CRACK IN FRAME AT STATION 1136 LONGERON 6R. INSTALLED DOUBLER ON FRAME STATION 1136 L6R PER AARD 53-10-00-30. (M)
- 30 Jan 2003
Frame, cracked
TUL - FOUND CRACK IN FRAME STATION 1174 AT LONGERON 6 LEFT. INSTALLED FRAME DOUBLER AT STATION 1174, L6L PER AARD 53-10-00-30. (M)
- 29 Jan 2003
Frame, cracked
TUL - FOUND CRACK FS 503. INSTALLED REPAIR DOUBLER ON FRAME REF SRM 53-10-00-30. (M)
- 11 Mar 2001
Wire, loose
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT COCKPIT OVERHEAD PANEL INOPERATIVE. RE-SECURED EMERGENCY EXIT LIGHT WIRE AT OVERHEAD COCKPIT…
- 26 Nov 2000
O-Ring, leaking
BNA - FLT 1669 - EN ROUTE LGA-HOU, DETECTED LOS OF RIGHT SIDE HYDRAULIC QUANTITY. AIR INTERRUPTED, DIVERTED BNA AND LANDED WITHOUT FURTHER INCIDENT. REPLACED…
- 16 Nov 2000
Wire, chafed
SFO - DURING OVERNIGHT MAINTENANCE, AISLE EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED EMERGENCY EXIT WIRES AT SEAT ROW 21. SYSTEM GROUND CHECKED NORMAL…
- 10 Mar 2000
Sensor, defective
DFW - FLT 2355 - AFTER TAKEOFF, RED NOSE GEAR DOWN LIGHT REMAINED ILLUMINATED WITH GEAR HANDLE UP. LANDED DFW WITHOUT INCIDENT. REPEATED 3/11/2000 WITH TRIP…
- 20 Nov 1999
Holder, defective
ORD - DURING OVERNIGHT MAINTENANCE, ELECTRICAL BURNING SMELL NOTED IN THE AFT GALLEY DOOR AREA. REPLACED UPPER SIDEWALL LIGHT SOCKET IN AFT GALLEY AREA.…
- 16 Aug 1999
Bulb, shorted
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS FROM ROW 21 AFT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BULBS AT SEAT 27D. SYSTEM…
- 27 Jun 1999
Light, broken
DFW - DURING OVERNIGHT MAINTENANCE SEAT MOUNTED EMERGENCY EXIT LIGHT ASSEMBLY AT ROW 12 INOPERATIVE AND MISSING LENS. REPLACED SEAT MOUNTED LIGHT ASSEMBLY AND…
- 1 May 1999
Jamb, corroded
TUL - FOUND CORROSION ON LOWER DOOR JAMB BEAM OUTBOARD SIDE AT STATION 1242 BELOW RIGHT TIE DOWN TRACK. TREATED AND PRIMED BLENDED AREA. INSTALLED DOUBLER PER…
- 30 Apr 1999
Seat Track, corroded
TUL - FOUND CORROSION ON SEAT TRACK NR 3. REPLACED SECTION OF SEAT TRACK FROM STATION 1222-1309 PER SRM 53-05 FIG 4F. (M)
- 31 May 1998
Light, inoperative
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT IN TAIL CONE COMPARTMENT INOPERATIVE. REPLACED EMERGENCY FLOOD LIGHT ASSEMBLY IN TAIL CONE COMPARTMENT.…
- 5 Jan 1998
Sensor, defective
DFW - DURING OVERNIGHT CHECK, NOSE LANDING GEAR GREEN LIGHT WOULD NOT ILLUMINATE WITH HANDLE DOWN. REPLACED NLG UPLOCK SENSOR. ACCOMPLISHED NLG RETRACTION…
- 24 Dec 1997
Sensor, dirty
ORD - FLT 0317 - EN ROUTE LGA/ORD, NOSE GEAR RED LIGHT ILLUMINATED DURING DESCENT. LANDED ORD WITHOUT INCIDENT. INSPECTED NOSE GEAR, FOUND TO BE DRY.…
- 14 Nov 1997
Wire, corroded
DFW - DURING OVERNIGHT CHECK, FOUND THREE EMERGENCY LIGHTS IN AFTSTAIRS TAIL CONE AREA INOPERATIVE. REPLACED SECTION OF WIRE. SYSTEM GROUND CHECKED NORMAL…
- 14 Nov 1997
Connector, corroded
DFW - DURING OVERNIGHT CHECK, FUOND EMERGENCY LIGHTS IN AFT STAIR WELL INOPERATIVE. REPLACED LIGHT FIXTURE CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 31 Jan 1997
Hydraulic Line, leaking
DFW - FLT 1945 - AFTER TAKEOFF DFW DURING CLIMB-OUT, FUMES NOTED IN CABIN. ACCOMPLISHED ABNORMAL PROCEDURES AND FUMES CLEARED WHEN AIR CONDITIONING PACKS…
- 24 Mar 1996
Connector, loose
ORD - DURING OVERNIGHT CHECK, EMERGENCY EXIT SIGN AT AFT SIGN AT AFT GALLEY DOOR INOPERATIVE. CLEANED AND RESEATED EMERGENCY EXIT SIGN CONNECTOR API-4 AT AFT…