Piper PA-18-150 FAA →
earlier registrations
3 past records
- 1979
service difficulty reports
37 reports
- 10 Oct 2012
Battery Pack, discharged
EMERGENCY LIGHTS FROM EXIT ROW FORWARD FOUND TO BE INOPERATIVE IN FLOOR DURING INSPECTION. REPLACED FORWARD BATTERY PACK I/A/W DC-9 MM 33-52-01. OPS CHECK WAS…
- 10 Oct 2012
Battery Pack, discharged
EMERGENCY LIGHTS FROM EXIT ROW FORWARD FOUND TO BE INOPERATIVE IN FLOOR DURING INSPECTION. REPLACED THE AFT BATTERY PACK I/A/W DC-9 MM 33-52-01. OPS CHECK WAS…
- 10 Oct 2012
Socket, damaged
LAST RED EMERGENCY LIGHT IN AISLE FLOOR FOUND TO BE INOPERATIVE DURING INSPECTION. MX R & R THE LAST RED EMERGENCY LIGHT LAMP HOLDER ASSEMBLY ON AISLE FLOOR…
- 10 Oct 2012
Socket, damaged
ROW 13 WHITE EMERGENCY LIGHT IN FLOOR LIGHTS FOUND TO BE INOPERATIVE DURING INSPECTION. MX REPLACED THE LAMP HOLDER ASSY (SOCKET) IAW AMM 33-52-01 AT ROW 13.…
- 22 May 2012
Pan, corroded
FORWARD LOWER CARGO DOOR LOWER PAN CORRODED. MX REMOVED CORRODED PAN AND PERFORMED SPLICE. REPAIR IAW SRM 53-05, FIG 44 AND EA 96-51-02 R1.
- 30 Sep 2011
Wire, broken
PASSENGER CABIN EMERGENCY FLOOR ESCAPE PATH LIGHTING FOUND TO BE INOPERATIVE WHILE PERFORMING A SERVICE CHECK. MX FOUND A SHORT IN THE EMERGENCY EXIT FLOOD…
- 8 Jan 2011
Wire, damaged
CABIN OVERHEAD EMERGENCY LIGHTS FOUND INOPERATIVE DURING PERFORMANCE OF AN A-CHECK. MX REPLACED BATTERY PACKS WITH SERVICEABLE. AFTER REPLACEMENT OF BATTERY…
- 25 Nov 2010
Battery Pack, discharged
RT AFT NACELLE LIGHT DOES NOT ILLUMINATE WITH EMERGENCY LIGHT SWITCH. FOUND DURING SERVICE CHECK. MX REPLACED THE EMERGENCY POWER SUPPLY IAW MM33-53-00. ACFT…
- 16 Apr 2008
Frame, cracked
LONGERON 25 LEFT HAD CRACK INDICATIONS AT BOTH ATTACH FASTENERS TO FRAME AT FS 160. REMOVED AND REPLACED DAMAGED SECTION IAW DC9 SRM.
- 16 Apr 2008
Cusp Web, cracked
CUSP WEB CRACKED AT FS 218, LEFT BUTT LINE 44. INSTALLED REPAIR DOUBLER IAW DC9 SRM 53-01.
- 11 Apr 2008
Stop Fitting, cracked
RIGHT AFT OVERWING EXIT DOOR HAD CRACK AT UPPER STOP. REPAIRED RIGHT AFT OVERWING EXIT DOOR AT UPPER STOP IAW DC9 SRM 52-05.
- 27 Sep 2007
Angle, cracked
RIGHT ANGLE CRACKED STA 69.550 TO 83.550 X = 10.00. REPLACED ANGLE IAW DC9 SRM 51-30-2.
- 27 Sep 2007
Bracket, cracked
LEFT VERTICAL BRACKET CRACKED, STA 69.55 AND X = 10.00. REPLACED BRACKET IAW DC9 SRM 51-30-2 AND 51-30-5.
- 27 Sep 2007
Bracket, cracked
RIGHT VERTICAL BRACKET CRACKED, STA 69.55 AND X = 10.00. REPLACED BRACKET IAW DC9 SRM 51-30-2 AND 51-30-5.
- 24 Sep 2007
Frame, cracked
CENTER FRAME LEFT END CRACKED MORE THAN 1.12 INCH, BUT LESS THAN 2.50 INCH, STA 83.55 AND X = 10.00. REPAIRED FRAME IAW DC9 SRM 53-03, FIGURE 34.
- 24 Sep 2007
Frame, cracked
DURING INSPECTION TO COMPLY WITH AD 2002-21-09 AND S/B 53-290 NOSE SKIN, STA 73, LBL 10, P/N 5911403-3 FOUND CRACKS ON THE AFFECTED FRAMES, P/N…
- 24 Oct 2000
Battery Pack, discharged
TPA - FOUND THE R2 AND L2 DOOR EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE AFT CARGO BATTERY PACK. (M)
- 7 Aug 2000
Valve, failed
BWI - FLT 2633 - ON CLIMB-OUT FROM BWI, THE NR 1 ENGINE BLEED TRIP OFF LIGHT ILLUMINATED (RESET WAS SUCCESSFUL) AND THE EGT WENT TO 645 DEGREES FOR 5 SECONDS.…
- 22 Feb 2000
Skin, cracked
TPA - SKIN HAS A 3 INCH CRACK AT BS 971 STRINGER 21L. INSTALLED DOUBLER PER SRM 53-30-3 FIG 1 AND EA 66147. (M)
- 22 Feb 2000
Skin, cracked
TPA - SKIN HAS A 2 INCH CRACK AT BS 964 STR 19L. REPAIRED PER SRM 53-50-3 FIG 1 AND EA 66148. (M)
- 28 Jan 2000
Unknown, smoke
PVD - FLT 2655 - ON CLIMB-OUT FROM PVD, AT APPROXIMATELY 8,000 FEET, THE SMOKE DETECTOR IN THE AFT LAVATORY BEGAN SOUNDING AND A SMELL IN THE AFT CABIN WAS…
- 24 Jan 2000
Gasper Fan, failed
IAD - FLT 2800, AFTER CLIMB-OUT FROM BWI, LEVELING OFF AT FL230, CREW NOTICED AN ODOR THROUGHOUT THE COCKPIT AND CABIN. FLIGHT ATTENDANT PULLED CIRCUIT…
- 17 Sep 1999
Battery Pack, discharged
CLE - MAINTENANCE FOUND THE LEFT EXTERIOR OVERWING AND LOWER AFT EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK AND POWER…
- 15 Sep 1999
Drive Motor, failed
MIA - FLT 2739 - CAPT REPORTED HE WAS EIGHT MILES ON FINAL APPROACH AND HAD JUST SET THE FLAPS TO A SETTING OF 1 DEGREE WHEN THE 'A' SYSTEM HYDRAULICS FAILED.…
- 27 Jun 1999
Skin, cracked
PHL - DURING RON, FOUND 2.5 INCH CRACK IN SKIN AT STATION 884 AT STRINGER 24 RT. INSTALLED DOUBLER REPAIR AT STRINGER AREA PER SRM 53-30-3, FIG 1 SHT 4. (M)
- 14 May 1999
Skin, cracked
TPA - DURING CX-6 CHECK, FOUND 2.5 INCH CRACK IN SKIN AT BS 756 AND S17L. INSTALLED DOUBLER MADE OF 2024T3 .071 INCH THICK PER SRM 53-30-3 FIG 1. (M)
- 14 May 1999
Skin, cracked
TPA - DURIGN CX-6 CHECK, FOUND .125 INCH CRACK IN SKIN AT BS 727A AND S16L. INSTALLED DOUBLER MADE FROM 2024T3 .100 INCH THICK PER SRM 53-30-3 FIG 1. (M)
- 25 Mar 1999
Csd, failed
CLE - FLT 1055 - ON CLIMB-OUT FROM CLE, THE NR 1 ENGINE GENERATOR DROPPED OFF LINE. CREW COULD NOT RESET THE GENERATOR. DUE TO THE APU BEING ON MEL, THE…
- 10 Aug 1998
Light, inoperative
GSO - MAINTENANCE FOUND THE AFT LEFT SERVICE DOOR EXTERIOR LIGHT INOP. MAINTENANCE FOUND A BAD WIRE SPLICE. REMOVED AND REPLACED WIRE SPLICE 1724. OPERATIONAL…
- 18 Jun 1998
Skin, cracked
TPA - DURING CX-5 CHECK VISUAL INSPECTION, FOUND A 2.50 INCH CRACK IN SKIN STA 727B JUST BELOW STR 15L. INSTALLED DOUBLER PER TYPICAL REPAIR NR 53-30-14. (X)
- 18 Jun 1998
Former, cracked
CLT - DURING CX-5 CHECK VISUAL INSPECTION, FOUND A 10 INCH CRACK IN ANGLE FORMER RT WING L/E AT W STATION 219. INSTALLED MODIFIED PART. (M)
- 18 Jun 1998
Skin, cracked
TPA - DURING CX-5 CHECK VISUAL INSPECTION, FOUND A 3.75 INCH CRACK IN THE SKIN AT STATION 727B STRIGNER 17R. INSTALLED DOUBLER PER TYPICAL REPAIR NR 53-30-14.…
- 12 Jul 1997
Skin, cracked
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 3 INCH SKIN CRACK BS 1154 BETWEEN STRINGER 2R AND STRINGER 3R. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3. (M)
- 16 Jan 1997
Wire, broken
PHL - MAINTENANCE FOUND THE LOW LEVEL EMERGENCY LIGHTING INOP AT ROW 11ABC. MAINTENANCE REPAIRED BROKEN WIRE AT ROW 11ABC. OPS CHECK GOOD. (M)
- 22 Jul 1996
Indication, malfunctioned
CLT - FLT 1979 - ON DESCENT INTO CLT, WHEN LANDING GEAR LOWERED,CREW RECEIVED THREE GEAR RED LIGHTS AND THREE GEAR GREEN LIGHTS. THE GEARHORN SOUNDED AT FLAPS…
- 4 Jul 1996
Skin, cracked
BOS - DETECTED BY VISUAL AND EDDY CURRENT AND 4.25 INCH CRACK IN SKIN AT STATION 727B AT STRINGER 15R. INSTALLED DOUBLER 13.375 INCH BY 8.5 INCH PER SRM…
- 11 Mar 1995
Line, leaking
CLT - FLT 2188 - EN ROUTE TPA TO LGA, LOST 'A' SYSTEM HYDRUALIC QUANTITY, FOLLOWED BY LOW 'A' PRESSURE LIGHTS. FLIGHT DIVERTED TO CLT WHERE LANDING WAS…