N230AU
Boeing 737-2Q9 FAA →
earlier registrations
1 past record
service difficulty reports
13 reports
- 22 Jan 1999
Skin, cracked
TPA - DURING CX-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK IN FUSELAGE SKIN STATION 727B AND STRINGER 17L. INSTALLED DOUBLER PER SRM 53-30-3 FIG 25. (M)
- 15 Dec 1998
Skin, cracked
CLT - DURING RON VISUAL INSPECTION, FOUND A 3 INCH CRACK STATION 737 OF FUSELAGE STRINGER 17 RT SKIN. INSTALLED DOUBLER PER SRM 53-30-3 FIG 25. (M)
- 6 Oct 1998
Engine, fod
PHL - FLT 886 - DURING CLIMB-OUT FROM PHL AT APPROXIMATELY 1,100 FT, THE CAPTAIN REPORTED SEEING A LARGE BIRD GO PAST THE AIRCRAFT. THE BIRD STRUCK THE NR 2…
- 7 Jan 1998
Skin, cracked
ROA - DURING CX-6 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK BS 727A PLUS 8 STRINGER 18L FUSELAGE SKIN. STOPPED DRILLED CRACK AND INSTALLED DOUBLER,…
- 7 Jan 1998
Skin, cracked
ROA - DURING 'CX-6' CHECK VISUAL/EDDY CURRENT INSPECTION, FOUND 2.75 INCH CRACK STR 24R STA 885 SKIN (FUSELAGE). STOP DRILLED CRACK AND INSTALLED DOUBLER,…
- 25 Mar 1997
Skin, cracked
ROA - DURING CX-5 CHECK VISUAL/EDDY CURRENT INSPECTION, FOUND 4.5 INCH CRACK, 3.25 INCH CRACK AT STRINGER 17R BS 727B FUSELAGE SKIN. INSTALLED DOUBLER,…
- 26 Sep 1996
Press Switch, leaking
CLT - FL 338 - SHORTLY AFTER TAKEOFF, THE 'A' SYSTEM HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED. HYDRAULIC QUANTITY INDICATED ZERO. CREW RETURNED TO FIELD AT…
- 14 Jul 1996
Oil Cooler, failed
BOS - FLT 788 - ON CLIMB-OUT AT APPROXIMATELY 10,000 FEET, THE NR 1 ENGINE OIL TEMPERATURE GAUGE WENT INTO THE YELLOW BAND. TEMPERATURE DECREASED WITH POWER…
- 14 May 1996
Frame, cracked
INT - DURING Q-4 CHECK EDDY CURRENT, FOUND TWO CRACKS .125 INCH LONG, STATION 727 STRINGER 18A LEFT FRAME. REPLACED FRAME SECTION AND REPAIRED PER EO…
- 14 May 1996
Angle, corrosion
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 2 NCH AFT ENTRY THRESHOLD 'Z' ANGLE UPPER LEG. REPLACED UPPER LEG OF 'Z' ANGLE, REPAIRED…
- 14 May 1996
Floor Beam, corrosion
INT - DURING Q-4 CHECK, FOUND SEVERAL 1 INCH BY 2 INCH CORRODED AREAS AROUND NUT-PLATES SPANNING A TOTAL OF 86 INCHES, STATION 987 LBL 36 INCHES TO RBL 50…
- 14 May 1995
Frame, cracked
INT - DURING Q-4 CHECK EDDY CURRENT, FOUND TWO CRACKS .125 INCH LONG, STATION 727 STRINGER 18A RIGHT. REPLACED FRAME SECTION AND REPAIRED PER EO 5394G068. (M)
- 10 Jan 1995
Eel, inoperative
DCA - THE LEFT EMERGENCY EXIT OVERWING LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AT EMERGENCY EXIT ROW. (W)