- 1983
service difficulty reports
33 reports
- 4 Sep 2006
Pump, failed
DFW - IAH TO ORD - FUEL WOULD NOT FEED FROM CENTER TANK. LANDED DFW WITHOUT INCIDENT. FOUND AFT CENTER TANK FUEL BOOST PUMP CIRCUIT BREAKER TRIPPED. REPLACED…
- 19 Oct 2005
Wire, broken
SFO - DURING OVERNIGHT MAINTENANCE FOUND EMERGENCY CEILING LIGHTS ROWS 23-26 INOPERATIVE. REPAIRED BROKEN WIRE AT EMERGENCY POWER SUPPLY AT ROW 26 RIGHT HAND…
- 2 Oct 2005
Battery Pack, inoperative
SAT - AFT OVERWING AND OVERHEAD EMERGENCY LIGHTS AT ROWS 24 - 28 INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY PACK FOR AFT OVERWING AND OVERHEAD EMERGENCY…
- 31 Jan 2005
Wire, broken
TPA - EMERGENCY EXIT LIGHT AT FORWARD GALLEY AISLE WALL INOPERATIVE. REPAIRED BROKEN WIRE IN AISLE FLOOR TRACK FOR EMERGENCY EXIT LIGHT AT FORWARD GALLEY…
- 15 Jan 2005
Battery Pack, discharged
LAX - EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACKS AT B5101, B5100, AND B5105 FOR EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL…
- 19 Sep 2004
Connector, loose
DFW - TAIL CONE RELEASE HANDLE EMERGENCY LIGHT INOPERATIVE. REPINNED TAIL CONE RELEASE HANDLE EMERGENCY LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 8 Mar 2004
Battery Pack, inoperative
ORD EMERGENCY LIGHTS ABOVE ROW 9 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS ABOVE ROW 9. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 5 Mar 2004
Battery Pack, inoperative
MIA - EMERGENCY EXIT LIGHTS ABOVE LEFT AND RIGHT HAND OVERWING EXIT INOPERATIVE. RESET BATTERY PACKS FOR EMERGENCY EXIT LIGHTS ABOVE LEFT AND RIGHT HAND…
- 6 Jan 2004
Battery Pack, discharged
EMERGENCY LIGHTS ABOVE ROWS 7, 8, 9 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT ROWS 7, 8, AND 9. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 15 Nov 2003
Engine, malfunctioned
IAD T646/14 EN ROUTE MIA-YYZ AIRCRAFT LOST OIL PRESSURE AND QUANTITY IN NUMBER ONE ENGINE. LANDED AT IAD WITHOUT INCIDENT. REPLACED NUMBER ONE ENGINE. SYSTEM…
- 6 Oct 2003
Battery Pack, discharged
AUS - FOUND DURING OVERNIGHT MAINTENANCE, OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT PACK B5-2. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED…
- 24 Jul 2003
Clamp, loose
FLT 528 - DFW-ATL - TAIL COMPARTMENT HIGH TEMP LIGHT CAME ON 3 TIMES DURING CLIMB-OUT. AIRCRAFT RETURNED DFW AND LANDED WITHOUT INCIDENT. MAINTENANCE…
- 27 Feb 2003
Fan, malfunctioned
STL - FLT 2216 - EN ROUTE TUL-STL, SHORTLY AFTER TAKEOFF, FLIGHT ATTENDANT REPORTED SMOKE AND FUMES IN THE CABIN. PILOTS TURNED OFF RECIRCULATION FAN AND…
- 21 Feb 2003
Skin, cracked
TUL - FOUND TWO .25 INCH CRACKS EXTENDING FROM FASTENER HOLE IN FUSELAGE SKIN RIGHT SIDE STATION 1380 BETWEEN LONGERONS 13R AND 14R. STOP DRILLED CRACKS AND…
- 21 Feb 2003
Skin, cracked
TUL - FOUND THREE CRACKS EXTENDING FROM FASTENER HOLE IN FUSELAGE SKIN LT SIDE STATION 1380 BETWEEN LONGERONS 13L AND 14L. STOP DIRLLED CRACKS AND INSTALLED…
- 9 Feb 2003
Battery, inoperative
SAN - DURING OVERNIGHT MAINTENANCE, AFT HALF OF SEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHTS BATTERY. SYSTEM GROND CHECKED…
- 1 May 2002
Boot, blown
DFW - FLT 1191 - EN ROUTE DFW-SMF - APPROXIMATELY 10 MINUTES AFTER TAKEOFF, CLIMBING THROUGH 17,000 FEET TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED.…
- 5 Aug 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY PATH LIGHTING IN LOWER TAIL CONE INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 19 Jul 2001
Battery Pack, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, CEILING MOUNTED EMERGENCY EXIT LIGHT AT ROW 13 THROUGH 16 INOPERATIVE. REPLACED CEILING MOUNTED EMEREGNCY EXIT LIGHT…
- 19 Jul 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY FOR AFT OVERWING EXIT SIGN. SYSTEM GROUND CHECK NORMAL…
- 30 May 2001
Clamp, defective
LAX - FLT 335 - EN ROUTE LAX-SJD - SHORTLY AFTER TAKEOFF TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. RETURNED LAX AND LANDED WITHOUT FURTHER…
- 15 May 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY CEILING LIGHTS FROM ROWS 26 THROUGH 29 DIM. REPLACED BATTERY PACK FOR EMERGENCY CEILING LIGHTS AT ROW 26 THROUGH…
- 27 Sep 2000
Connector, failed
OMA - FLT 2463 - EN ROUTE OMA-DFW, SHORTLY AFTER TAKEOFF PILOTS REPORTED SMOKE IN THE COCKPIT AND CABIN THAT CONTINUED TO GET WORSE. RETURNED TO OMA AND…
- 9 Aug 2000
Wire, broken
ORD - FLT DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIR EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRE. SYSTEM GROUND CHECK NORMAL OPERATION. (M)
- 7 Jan 1999
Apu, leaking
MIA - FLT 1246 - EN ROUTE MIA-LGA - ABOUT 3 TO 4 MINUTES AFTER TAKEOFF, EXPERIENCED SMOKE IN CABIN AT 3,000 FEET. ACCOMPLISHED AIR CONDITIONING SMOKE AND…
- 11 Nov 1998
Connector, failed
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTING AT FIRST CLASS GALLEY INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP FLAP…
- 19 Jun 1998
Frame, cracked
TUL - FOUND FRAME 420 BELLFRAME CRACKED AT HORIZONTAL DOOR FRAME STIFFENER ATTACH POINT HI-LOK STRINGER 20R, VIEWED FROM UNDER SIDE OF COLLAR. INSTALLED…
- 19 Mar 1998
Longeron, corroded
TUL - FOUND CORROSION IN L29L, STATION 370 TO 427. INSTALLED STRAP DOUBLER PER ESO 80559. (M)
- 19 Mar 1998
Longeron, corroded
TUL - FOUND L30 HAS CORROSION STATION 370 TO 427. INSTALLED DOUBLER STRAP PER ESO 80559, DATED 3/19/98. (M)
- 24 Feb 1998
Acm, defective
DFW - FLT 2076 - IAH-DFW - SHORTLY AFTER TAKEOFF A BURNING SMELL LIKE A DIRTY PACK SOCK WAS IN COCKPIT AND AFT CABIN. CAIBN FROM MID TO AFT HAD A HAZE IN IT.…
- 26 Apr 1997
Fan, defective
BNA - FLT 0839 - EN ROUTE ORF/DFW DURING CRUISE, ACRID ODOR NOTED IN CABIN. AIRCRAFT DESCENDED TO FL 100 AND INTENTIONALLY DEPRESSURIZED AND ODOR SUBSIDED.…
- 26 Mar 1996
Wire, defective
DFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING IN THE FORWARD CABIN DIM. REPLACED CONNECTOR WIRE. SYSTEM GROUND CHECKED, NORMAL…
- 26 Mar 1996
Wire, defective
DFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING IN THE FORWARD CABIN AND MAIN CABIN DIM. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING…