26 reports
- 8 Jan 2003
Relief Valve, leaking
EMERGENCY FLOAT RELIEF VALVE LEAKING. REPAIRED.
- 30 Jul 2002
Oil Cooler, leaking
OIL COOLER LEAKING.
- 30 Jul 2002
Igniter, damaged
IGNITER PRODUCING A WEAK SPARK. ERODED INSULATOR. SCRAPPED.
- 30 Jul 2002
Clock, damaged
UNABLE TO ADJUST TIME ON CLOCK. ADJUSTMENT KNOB KEEPS COMING LOOSE. TIGHTENED KNOB, BUT IT KEEPS COMING LOOSE. SCRAPPED.
- 24 Aug 2001
Transceiver, failed
WILL NOT TRANSMIT AT THE RIGHT FREQUENCY. PERFORMED PRELIMINARY INSPECTION. ADJUSTED FREQUENCY, PULSE WIDTH AND POWER. ALIGNED PRESELECTOR AND IF. REPAIRED.…
- 21 Aug 2001
Fuel Control, malfunctioned
UNABLE TO ADJUST START TEMP. LOW ENOUGH TO GET ENG. STARTED. START MODE FUEL FLOW APPROX. 3 TIMES ALLISON LIMITS. FOUND FLOWS 12PPH HIGH. (METERING VALVE…
- 19 Jun 2001
Gps, failed
LOSES MEMORY. SENDING TO VENDOR FOR REPAIR.
- 11 Apr 2001
Gps, failed
LOCKS ON ONE LOCATION, WILL NOT UPDATE IN FLIGHT. SENT TO TRIMBLE NAVIGATION FOR WARRANTY REPAIR.
- 2 Apr 1999
Filter, malfunctioned
FILTER FAILS BYPASS CHECK.
- 23 Feb 1999
Starter, malfunctioned
STARTER/GENERATOR ARCHING AND MAKING NOISE.
- 23 Feb 1999
Starter, arced
STARTER/GENERATOR ARCHING AND MAKING NOISE.
- 1 Jul 1998
Transceiver, malfunctioned
TRANSCEIVER BREAKS SQUELCH HIGH END.
- 18 Jun 1998
Transponer, inoperative
TRANSPONDER NOT TRANSMITTING AND WILL NOT IDENT. FOUND IDENT REPLY LIGHT BLINKING ON AND OFF.
- 16 Apr 1998
Generator, failed
DROPS OFF LINE IN FLIGHT. COMES BACK ON WITH RESET FIELD SWITCH.
- 8 Dec 1997
Altimeter, defective
ALTIMETER HAS EXCESSIVE CASE LEAKAGE AROUND BASE KNOB.
- 9 Oct 1997
Indicator, failed
DUAL INDICATOR OIL PRESS SIDE GIVES LOW IND.
- 28 May 1997
PC Link, corroded
PC LINK HAS CORROSION BEYOND LIMITS ON TUBE AT COLLARS AND CENTER OF TUBES BEYOND LIMITS AS PER BELL 206B3 CR&O. REPLACED WITH SERVICEABLE P/C LINK.
- 13 May 1997
Actuator, inoperative
ACTUATOR INOPERATIVE AND CORRODED.
- 30 Apr 1997
Tube Assy, corroded
CORROSION ON CONTROL TUBE BEYOND LIMITS. SEVERAL AREAS HAD CORROSION. REPLACED WITH SERVICEABLE CONTROL ASSEMBLY.
- 23 Apr 1997
Indicator, reads high
READS HIGH BETWEEN 600 DEGREES - 800 DEGREES RANGE.
- 11 Feb 1997
Mount, separation
MOUNT SEPARATION BEYOND LIMITS.
- 5 Jun 1996
Transceiver, defective
NO IDENT LIGHT AND NO LIGHT ON TEST. REPLACED PHOTOCELL V201. REPAIRED. REPLACED DETERIORATED RESISTOR R477. ADJUSTED POWER OUT AND FREQUENCY TO SPECS. BENCH…
- 8 May 1996
Transducer, defective
FUEL PRESSURE FLUCTUATES BELOW 24 PSI CAUSING HIGH READING.
- 12 Oct 1995
Blade, corroded
EXCESSIVE AMOUNT OF EXFOLIATION ON UPPER LEADING EDGE NEAR THE TIP WITH PIECES MISSING.
- 5 Nov 1994
Blade, corroded
EXCESSIVE LEADING EDGE INNER GRANULAR CORROSION OVER THE SPAR AREA. THIS BLADE WAS REMOVED 12-22-93 FROM N 22679 FOR SAME PROBLEM. BLADE WAS BEING HELD IN…
- 23 Oct 1994
Display, weak
DISPLAY WEAK. REPLACED DISPLAY. REPAIRED.