N226US
Boeing 737-201 FAA →
reservations
earlier registrations
1 past record
service difficulty reports
30 reports
- 30 Jun 1999
Seat Track, corroded
DURING A C-CHECK, CORROSION WAS NOTED ON SEAT TRACK RT OUTBOARD STA 344 - STA 380.
- 24 May 1999
Battery Pack, discharged
GSO - MAINTENANCE FOUND THE AISLE SEAT EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED A WIRE SPLICE AND TWO BATTERY PACKS. OPERATIONAL CHECK…
- 19 Apr 1999
Battery Pack, discharged
BOS - PILOT REPORTED THAT THE AFT BATTERY PACK UNDER SEAT 16 LEFT NEEDS REPLACED DUE TO THE EMERGENCY LIGHTS ILLUMINATING DIM. MAINTENANCE REMOVED AND…
- 17 Apr 1999
Battery Pack, discharged
EWR - MAINTENANCE FOUND SEVERAL CABIN SEAT EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACKS AT SEATS 5A AND 16A AND RERACKED…
- 13 Apr 1999
Doubler, cracked
TPA - DURING HFEC CHECK INSPECTION, FOUND A .25 INCH CRACK IN MED REPAIR DOUBLER AFT LOWER CORNER OF MAIN ENTRY DOOR CUTOUT. INSTALLED NEW DOUBLER PER EO…
- 11 Apr 1999
Battery Pack, discharged
TPA - MAINTENANCE FOUND THE LEFT AND RIGHT EXTERIOR OVERWING EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LEFT AND RIGHT BATTERY PACKS…
- 20 Mar 1999
Hose, ruptured
CLT - FLT 462 - ON CLIMB-OUT OF JAX, F/O NOTICED NR 2 ENG HYD PUMP LOW PRESSURE LIGHT ILLUMINATED. ACCOMP QUICK REF HANDBOOK PROCEDURES. APPROX 1 MIN LATE,…
- 13 Sep 1998
Sensor, out of adjust
ATL - FLT 496 - AFTER TAKEOFF AT APPROXIMATELY 500 FT, THE FORWARD CARGO DOOR WARNING LIGHT ILLUMINATED. FLIGHT RETURNED TO FIELD AT ATL AND LANDED WITHOUT…
- 12 Apr 1998
Skin, cracked
ROA - DURING C-5 CHECK, FOUND 1 INCH CRACK IN FUSELAGE SKIN AT LOWER HINGE CUTOUT OF AFT SERVICE DOOR. REMOVED CRACK AND INSTALLED DOUBLER PER EA 61580. (M)
- 12 Apr 1998
Skin, cracked
ROA - DURING C-5 CHECK, FOUND 2 INCH CRACK AT STA 740, S17R FUSELAGE SKIN. REMOVED CRACK AND INSTALLED DOUBLER PER EA 51596. (X)
- 17 Jan 1998
B-Nut, loose
SAV - FLT 1481 - AT FL 310, THE 'A' SYSTEM HYDRAULIC QTY SLOWLY DROPPED TO 1.2 GALLONS. CAPTAIN NOTICED THE QTY HAD BEEN SLOWLY DROPPING OVER THE LAST HOUR.…
- 6 Jan 1998
Separator Bags, dirty
CLT - FLT 776 - CLIMBING THROUGH 4,000 FEET, CREW SMELLED A SMOKY ODOR THAT RESEMBLED A BURNING CANDLE SMELL IN THE COCKPIT. ODOR WAS ALSO PRESENT IN THE…
- 7 Dec 1997
Battery Pack, discharged
ATL - MAINTENANCE FOUND THE INTERIOR AND EXTERIOR EMERGENCY LIGHTS AT THE FORWARD ENTRY AND SERVICE DOOR INOP. MAINTENANCE REMOVED AND REPLACED THE FORWARD…
- 2 Dec 1997
Power Supply, failed
MCO - MAINTENANCE FOUND THE EMERGENCY EXIT LIGHTING AT ROWS 1 THROUGH 5, LEFT SIDE, INOP. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY AT SEAT ROW 5. OPS…
- 24 May 1997
Stringer, corrosion
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION 12 INCHES STATION 962 , STRINGER 27L. INSTALLED DOUBLER (SPLICE), REPAIRED PER SRM 53-10-3.…
- 24 May 1997
Skin, cracked
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 3 INCH BY .25 INCH CRACK FORWARD LOWER CORNER AFT ENTRY DOOR SKIN. INSTALLED DOUBLER AND TRIPLER, REPAIRED PER…
- 24 May 1997
Frame, corroded
INT - DURING Q2-CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA AFT CARGO LOWER LEG OF FRAME BS 767 STRINGER 26R-25R. INSTALLED FRAME REPAIR…
- 24 May 1997
Skin, corrosion
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION 2 INCHES BY 4 INCHES APPROX BS 927 BETWEEN STRINGER 24L AND 25L SKIN. INSTALLED FILLER AND DOUBLER,…
- 24 May 1997
Stringer, corroded
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA BS 907, STRINGER 24L. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 51-10-1.…
- 24 May 1997
Stringer, corroded
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORRODED AREA AFT CARGO BS 907 STRINGER 26R. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3 FIG 1 SRM…
- 24 May 1997
Skin, cracked
INT - DURING Q-2 CHECK CHECK VISUAL INSPECTION, FOUND 1 INCH CRACK BS 380 BETWEEN STRINGER 28L AND BL '0' SKIN. INSTALLED DOUBLER DOUBLER, REPAIRED PER TR…
- 24 May 1997
Beam, cracked
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK BL '0' BL 660 WL 208 BEAM. INSTALLED REPAIR ANGLES, REPAIRED PER BOEING DRAWING NR 65C34537. (M)
- 24 May 1997
Frame, cracked
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK FORWARD CARGO FRAME BS 500 BL '0'. INSTALLED DOUBLER AND FILLER, REPAIRED PER SRM 51-40-3 FIG 1.…
- 24 May 1997
Skin, dented
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND DENTS 2.5 INCH BY 3 INCH AND 1.5 INCH BY 1.5 INCH STATION 807 BETWEEN STRINGER 19L AND 20L SKIN. INSTALLED…
- 24 May 1997
Skin, cracked
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 3 INCH CRACK IN SKIN AT LOWER FORWARD CORNER OF DOOR CUTOUT AFT ENTRY DOOR BS 964. INSTALLED EXT SKIN REPAIR…
- 4 Apr 1997
Garlock Seal, failed
BWI - FLT 1243 - FLIGHT HAD JUST LEVELED OFF AT 28,000 FEET WHEN CREW NOTICED THE NR 1 ENGINE OIL QUANTITY BEGAN TO DECREASE TOWARDS ZERO. FLIGHT DIVERTED TO…
- 13 Sep 1996
Skin, cracked
ROA - DURING 'CX-3' CHECK VISUAL/EDDY CURRENT INSPECTION, FOUND .125 INCH CRACK FORWARD GALLEY DOOR CUT OUT AFT LOWER CORNER FUSELAGE SKIN. REMOVED CRACK AND…
- 6 Sep 1996
Air Distr, odor
PIT - FL 553 - FLIGHT ATTENDANTS ADVISED COCKPIT CREW THAT THEY SMELLED SMOKE OR FUMES IN THE REAR OF THE AIRCRAFT. THEY DID NOT DETECT ANY SIGHT OF SMOKE.…
- 9 Jul 1996
Flow Control Vlv, failed
MSP - FLT 824 - ON CLIMB-OUT ABOVE 15,000 FEET, A LOUD RUMBLING NOISE BEGAN. CREW DECIDED TO RETURN TO FIELD AT MSP. ALL AIRCRAFT INDICATORS WERE NORMAL. CREW…
- 15 Dec 1995
Stringer, corroded
ROA - DURING 'CX-2' CHECK VISUAL INSPECTION, FOUND 2 INCH CORRODED STRINGER CAUSED BY LAVATORY SPILL, STRINGER 27L AT BS 947. REMOVED CORRODED STRINGER…