- 11 Jun 2007
Bearing, separated
DURING A DAILY INSPECTION TECHNICIAN FOUND BEARING CAGE SEPARATED AT THE RIVETS. ALSO FOUND SEALS OUT OF THEIR RESPECTIVE RETENTION GROOVES. REQUEST THAT…
- 21 Jul 2003
Starter Gen, failed
FIRST START AFTER INSTALLATION GENERATOR WOULD NOT COME ON LINE. SHOP REPAIR.
- 30 Jul 1998
Torquemeter, failed
TORQUE METER NEEDLE STICKS AROUND 40 PERCENT THROUGH UPPER RANGE.
- 22 Jun 1998
Cylinder, leaking
MAIN ROTOR SERVO CYLINDER HAS EXCESSIVE LEAKAGE.
- 5 Jun 1998
Bearing, worn
TRANSMISSION RESTRA9INT BEARI8NG WORN.
- 4 Jun 1998
Skin, corroded
DOOR INSPECTION FOUND CORROSION BLEEDING OUT FROM INNER AND OUTER SKINS AND CORROSION BLEEDING OUT FROM FIBERGLASS CORNER FAIRING.
- 4 Jun 1998
Indicator, inoperative
TURBINE NEEDLE WILL NOT COME UP.
- 4 Jun 1998
Link Assembly, worn
M/R GEARBOX ELASTOMERIC IS WORN.
- 20 May 1998
Support, damaged
DEEP SANDING MARKS ON BOTTOM AT RADIUS OF BRACKET. POOR QUALITY CONTROL.
- 16 Apr 1998
Transceiver, failed
PULSE WIDTH OUT OF SPECS. UNABLE TO CHANGE PULSE WIDTH DUE IT BEING A SURFACE MOUNT COMPONENT.
- 3 Dec 1997
Drive Link, defective
WHILE ATTEMPTING TO INSTALL DRIVE LINK, FOUND TEFLON JOINTS WERE TOO TIGHT, NOT ALLOWING DRIVE LINK TO MOVE FREELY. COLLAR BOLT WAS VERY DIFFICULT TO REMOVE.…
- 28 Nov 1997
Indicator, defective
INDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DIDN'T WORK.
- 8 May 1996
Link Assy, bearing separate
LINK ASSY ELASTOMER BEARINGS SEPARATED. S/N LK0208 &LK7022
- 28 Feb 1996
Restraint, bearing worn
RESTRAINT HAS WORN BEARINGS.
- 21 Sep 1995
Fuel Control, leaks
FUEL LEAKS FROM BY-PASS VALVE RETENTION PLATE. REPLACED WITH SERVICEABLE FUEL CONTROL.
- 13 Jun 1995
Transponder, defective
WILL NOT TEST; DOES NOT APPEAR TO HAVE POWER. UNIT WON'T TURN ON. REPLACED SWITCH BOARD ASSY. REPAIRED. UNIT WON'T TRANSMIT. REPAIRED BROKEN FOIL ON HIGH…
- 31 Mar 1995
Washer, deteriorated
EXCESSIVE LOAD ON PLUGS CAUSING MATERIAL TO DETERIORATE. SCRAPPED LOCALLY. APPLIED LOWER TORQUE ON ADJUSTMENT SCREWS AND LOWER PRELOAD ON THRUST PLUGS.
- 24 Oct 1994
Indicator, needle sticks
HANGS UP AT 700 DEGREES AND NEEDLE STICKS. TIME SINCE REPAIR 62:45.
- 2 Oct 1994
Actuator, inoperative
ACTUATOR INOPERATIVE. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND MOISTURE IN MOTOR AND NO GREASE IN CAVITY BETWEENOUTPUT SHAFT BUSHINGS. REPAIRED ACTUATOR…