- 26 Oct 2001
Sign, malfunctioned
RSW - FLT 5082 - CREW REPORTED THE EMERGENCY EXIT SIGN AT ROW 1 RIGHT SIDE TO BE INOPERATIVE. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. OPERATIONAL CHECK…
- 16 Oct 2001
Battery Pack, discharged
MIA - FLT 4964 - MAIN DOOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACKS 15WL AND 18WL IAW ATR 42 AMM.…
- 16 Oct 2001
Battery Pack, discharged
MIA - FLT 4964 - MAIN DOOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACKS 15WL AND 18WL IAW ATR 42 AMM.…
- 30 Dec 2000
Rod, broken
TPA - FLT 5379 - CREW REPORTED HUMMING SOUND FROM NOSE AREA IN FLIGHT. POST FLIGHT INSPECTION REVEALED RIGHT NOSE GEAR DOOR DAMAGED CAUSED BY DOOR ATTACH ROD…
- 13 Dec 2000
Battery Pack, discharged
MIA - FLT 5229 - CREW REPORTED BOTH FORWARD EMERGENCY EXIT LIGHTS AT WINDOW EXITS ARE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BATTERY PACK AT POWER…
- 13 Dec 2000
Bulb, inoperative
MCO - FLT 5410 - PASSENGER DOOR EMERGENCY LIGHT IS INOPERATIVE. MAINTENANCE REPLACED LIGHT BULB. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 28 Sep 2000
Fitting, leaking
MIA - FLT 5284 - ON APPROACH, THE BLUE HYDRAULIC SYSTEM LOW LEVEL LIGHT ILLUMINATED. THE CREW SHUT DOWN THE BLUE SYSTEM, DECLARED AN EMERGENCY. THE ACFT…
- 1 Sep 2000
Guide, corroded
DURING MVB-1 FOUND RIGHT OUTBOARD FLAP, OUTBOARD DEFLECTOR CAM GUIDES CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLAP DEFLECTOR IAW SRM 57-53-11. (M)
- 1 Sep 2000
Seat Track, corroded
SAW - DURING CPCP-2, FOUND RIGHT FLIGHT ATTENDANT, RIGHT AFT INBOARD AND RIGHT OUTBOARD SEAT TRACK CORRODED BEYOND LIMITS. REMOVED AND REPLACED SEAT TRACKS…
- 1 Sep 2000
Sill Drain, corroded
SAW - DURING CPCP-2, FOUND SERVICE DOOR SILL PLATE DRAIN TRACK CORRODED BEYOND LIMITS. REMOVED AND REPLACED DRAIN TRACK IAW SRM 51-25-03. (M)
- 27 Aug 2000
Mount, chafed
SAW - DURING MBV-1 INSPECTION, MAINTENANCE REPORTED, THE LEFT ENGINE OUTBOARD ZEE MOUNT CHAFED BY THE HP BLEED VALVE. MAINTENANCE REMOVED AND REPLACED THE ZEE…
- 12 Jul 2000
Acm, frozen
MIA - FLT 5217 - FLIGHT ATTENDANT REPORTED SMOKE SMELL IN THE CABIN. SMELL COULD ALSO BE DETECTED IN THE COCKPIT. THE AIRCRAFT RETURNED TO THE GATE AND WAS…
- 22 Mar 2000
Battery Pack, discharged
MIA - FLT 5290 - WITH BATTERY IN OFF POSITION FA CAN NOT ACTIVATE THE EMERGENCY LIGHTS. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY. OPS CHECK GOOD. (M)
- 22 Mar 2000
Battery, missing
MIA - ALL EMERGENCY LIGHTS INOPERATIVE. FOUND BATTERIES NOT INSTALLED IN POWER SUPPLIES. INSTALLED SAME, OPS CHECKED IAW 33-51-21. OPS CHECK GOOD. AIRCRAFT…
- 10 Jun 1999
Switch, out of adjust
BOS - FLT 4963 - FORWARD CARGO DOOR WARNING CAME ON AFTER TAKEOFF. DECLARED EMERGENCY. RETURNED TO FIELD. ADJUSTED DOOR PROXIMITY SWITCH AND PERFORMED…
- 11 May 1999
Floorbeam, corroded
SAW - DURING CPCP-1 INSPECTION, FOUND FLOORBEAM 40 CORRODED. REMOVED AND REPLACED FLOORBEAM 40 IAW 53-61-40. AIRCRAFT RETURNED TO SERVICE. (M)
- 11 May 1999
Web, corroded
SAW - DURING CPCP-1 INSPECTION, FOUND THE RIGHT AFT FLOOR WEB BETWEEN FRAME 39 AND 40 CORRODED. REMOVED AND REPLACED THE WEB IAW SRM 51-25-02. AIRCRAFT…
- 11 May 1999
Zee, corroded
SAW - DURING CPCP-1 INSPECTION, FOUND RIGHT AFT CARGO ZEE MEMBER BETWEEN FRAME 39 AND 40 CORRODED. REMOVED AND REPLACED THE ZEE MEMBER IAW SRM 51-25-02.…
- 10 May 1999
Floorbeam, corroded
SAW - DURING CPCP-1 INSPECTION, FOUND FLOORBEAM 38 AND 39 CORRODED. MAINTENANCE REPAIRED THE FLOORBEAMS IAW SRM 53-00-00 FIGURE 438 AND 53-61-40 FIGURE 412.…
- 28 Jul 1998
Battery Pack, discharged
SAW - DURING PS-2 INSPECTION, THE AFT EMERGENCY EXIT SIGN AND AFT FLOOR PROXIMITY LIGHTS DID NOT ILLUMINATE. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY…
- 6 Jun 1998
Battery Pack, discharged
GRR - CABIN CENTER SECTION FLOOR PROXIMITY LIGHTS DO NOT ILLUMINATE. MEL'D PER MEL 33-22. RAI BATTERY PACK 16WL. OPERATIONAL CHECK GOOD. MEL CLEARED. (M)
- 26 May 1998
Battery Pack, discharged
SAW - DURING PS-2 INSPECTION, MAINTENANCE REPORTED THE RIGHT AND LEFT AFT EXTERIOR EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT…
- 18 May 1998
Drain Track, corroded
SAW - DURNG CPCP-4 INSPECTION, MAINTENANCE REPORTED THE SERVICE DOOR DRAIN TRACK BETWEEN FRAME 36 AND 40 CORRODED. MAINTENANCE REMOVED AND REPLACED THE…
- 18 May 1998
Zee Member, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE RIGHT AFT ZEE MEMBER, BETWEEN 39 AND 40 CORRODED. MAINTENANCE REMOVED AND REPLACED THE RIGHT AFT ZEE…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Seat Track, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING SEAT TRACKS CORRODED OUT OF LIMITS. THE LEFT FORWARD OUTBOARD, LEFT MIDDLE INBOARD, LEFT…
- 13 May 1998
Floorbeam, corroded
SAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED THAT FLOORBEAM 38 WAS CORRODED. MAINTENANCE REPAIRED FLOORBEAM 38 IAW SRM 53-00-00. A/C WAS RETURNED TO…
- 6 Apr 1998
Battery, discharged
ORD - FLT 4055 - THREE EMERGENCY FLOOR PROXIMITY LIGHTS AND THE TWO FORWARD EMERGENCY EXIT SIGNS DO NOT ILLUMINATE. REMOVED AND REPLACED EMERGENCY LIGHTING…
- 17 Mar 1998
Battery Pack, discharged
ORD - FORWARD EMERGENCY LIGHTING INOP. REPLACED EMERGENCY BATTERY PACKS AND POWER SUPPLIES FOR 3WL AND 27WL IAW ATR-42 JIC 33-51-21. OPERATIONAL CHECKS GOOD…
- 10 Nov 1997
Battery Pack, discharged
ORD - FLT 4161 - EMERGENCY LIGHT ON AFT CARGO DOOR INOP. REPLACED POWER SUPPLY AND BATTERY PACK 18WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 2 Jul 1997
Idler Arm, loose bearing
DFW - DURING COMPLIANCE OF ENGINEERING ORDER EO-2700-001 REPETITIVE INSPECTION OF AILERON CONTROL SYSTEM, AD 93-22-10, MTX FOUND ONE IDLER ARM IN LT WING…
- 1 Apr 1997
Light, inoperative
ORD - FLT 4001 - SERVICE DOOR EMERGENCY EXIT LIGHT INOP. RAI'D SERVICE DOOR EMERGENCY EXIT LIGHT SIGN. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 31 Oct 1996
Battery, discharged
SGF - EMERGENCY FLOOR LIGHTS 2, 4, 6, AND LOWER FORWARD SIGNS INOP. RAI'D EMERGENCY FLOOR LIGHT BATTERY FOR 2, 4, 6, AND LOWER FORWARD EMERGENCY SIGNS.…
- 13 Jun 1996
Light, failed
ORD - FLT 4059 - AIRSTAIR EMERGENCY LIGHT INOP. REPLACED LIGHT ASSY, OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 24 Sep 1995
Eel, inoperative
ORD - FLT NR 4265 - PASSENGER AIRSTAIR EMERGENCY LIGHT INOP. RAI'D LIGHT ASSEMBLY. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 24 Jun 1995
Act Bracket, broken
MQT - AFTER LANDING AT ORD, THE PILOT REPORTED THE GEAR MADE A LOUD BANG NOISE WHEN IT WAS LOWERED. MAINTENANCE INSPECTED THE GEAR AND FOUND THE RIGHT GEAR…