N20898
1982 Bell Helicopter Textron 206L-1 standard FAA →
earlier registrations
2 past records
- 2012
- 1982
service difficulty reports
17 reports
- 9 Jan 2003
Amplifier, inoperative
PA AMPLIFIER SIREN INOPERATIVE.
- 8 Jan 2003
Receiver, malfunctioned
FUNCTION BUTTONS REQUIRE 2-3 PUSHES THE CHANGE FUNCTION. SOME BUTTONS HAVE MARKINGS WORN OFF. ALL FUNCTION BUTTONS AND SWITCHES BAD. ALSO FOUND DISPLAY LENS…
- 7 Jan 2003
Transceiver, intermittent
TRANSCEIVER RECEIVES INTERMITTENTLY. FOUND NO RECEIVER AUDIO DUE TO BAD C147 CAPACITOR. REPLACED. REPAIRED PROBLEM. REALIGNED RECEIVER AND ADJUSTED C/N…
- 6 Jan 2003
Transceiver, weak
TRANSCEIVER RECEIVES WEAK AND BROKEN. FOUND RECEIVER AUDIO CUTTING OUT INTERMITTENTLY. REPLACED BAD C147 CAPACITOR. REPAIRED. FOUND MODULATION DISTORTED.…
- 13 Oct 1999
Tube Assy, corroded
FOUND TUBE CORRODED AND DAMAGED BEYOND LIMITS. REPLACED WITH SERVICEABLE TUBE ASSY.
- 13 Oct 1999
Crosstube, corroded
FOUND AFT CROSSTUBE CORRODED BEYOND LIMITS. REPLACED WITH SERVICEABLE TUBE ASSY.
- 13 Oct 1999
Retainer, corroded
CORRODED BEYOND LIMITS. REPLACED WITH SERVICEABLE RETAINERS.
- 13 Oct 1999
Fitting, corroded
FOUND FITTING CORRODED AND DAMAGED. REPLACED WITH SERVICEABLE FITTING.
- 25 Aug 1998
Indicator, reads high
PRESSURE READS HIGH OUT OF TOLERANCE.
- 14 Aug 1998
Starter, failed
STARTER HAS BURNT BRUSHES AND COMMUTER.
- 29 Apr 1998
Torquemeter, failed
TORQUEMETER NEEDLE DOESN'T RETURN TO ZERO.
- 6 Jan 1998
Indicator, failed
TOT INDICAOR INCORRECT READING.
- 17 Dec 1997
Indicator, sticks
INDICATOR NEEDLE STICKS THROUGH SCALE INTERMITTENTLY.
- 4 Mar 1996
Bearing, cracked
BEARINGS CRACKED. ALSO REPLACED 4 EACH SLEEVES, P/N 206-010-733-003 AND 8 EACH SPACERS, P/N 206-011-742-101. NOTE: SEE MMIR'S # 6826 THROUGH #6835 FOR…
- 15 May 1995
Support, req replacement
REMOVED TO COMPLY WITH ASB 206L-93-89 REV. B (REPLACEMENT OF -109 SUPPORT WITH -113 SUPPORT)
- 11 Apr 1995
Freewheel, seals leak
LEAKING FROM FORWARD AND AFT SEALS. REPLACED WITH SERVICEABLE FREEWHEELING UNIT AND RETURNED AIRCRAFT TO SERVICE.
- 10 Oct 1994
Actuator, inoperative
ACTUATOR INOPERATIVE. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND COLD SOLDER JOINT ON MOTOR AND MOISTURE IN MOTOR. ALSO NO GREASE BETWEEN OUTPUT SHAFT…