N206ME
2025 Textron Aviation INC T206H standard FAA →
registration
- 2025
earlier registrations
1 past record
- 1979
service difficulty reports
187 reports
- 24 Jun 2003
Rudder, inoperative
RUDDER FULL RIGHT APPLIED WITH NO APPARENT EFFECT. ADJUSTED CABLE RUN AND SENSING SECTOR, PERFORMED ADJUSTMENT TEST. NO DEFECTS NOTED. (AIRCRAFT PARKED SINCE…
- 25 May 2003
Switch, dirty
RECEIVED TAKEOFF WARNING HORN WHILE ADVANCING THROTTLES. -- CLEANED STICKY SWITCH.
- 17 Oct 2002
Line, disconnected
RIGHT ENGINE PRESSURE RATIO GAUGE REMAINED AT 10. FOUND PT7 LINE DISCONNECTED AT LOWER AFT ATTACH FITTING. RECONNECTED PT7 LINE.
- 6 May 2002
Valve, clogged
AILERON SERVO INDICATOR SHOWED FULL DEFLECTION. DISCONNECTED AUTO PILOT AND THE AIRCRAFT STARTED TO TURN TO THE LEFT. FOUND WATER DRAINING IN LEFT GEAR AREA…
- 11 Apr 2002
Longeron, cracked
FORWARD PIT LONGERON 29 RIGHT IS CRACKED AT STATION 570-578. -- REMOVED, MATCH DRILLED LONGERON AS REQUIRED PER DWG # 5910068, AND INSTALLED.
- 11 Apr 2002
Skin, damaged
REPLACE AFT CARGO PIT BELLY SKIN SECTION LONGERON 28 LEFT TO 28 RIGHT STATION 803 THROUGH 996 TO COMPLY WITH CARRY OVER NR 2201. REMOVED AND REPLACED SKIN.
- 11 Apr 2002
Support Bracket, corroded
FORWARD PIT LEFT AUX TANK STRUT UPPER SUPPORT BRACKET HAS EXFOLIATION AROUND A FASTENER STATION 545 LONGERON 24 LEFT. REMOVED AND REPLACED FITTING.
- 8 Apr 2002
Panel, damaged
REMOVED CABIN FLOOR PANEL B-5 TO FACILITATE OTHER MAINTENANCE. -- FORWARD END OF PANEL IS DAMAGED. FABRICATED NEW SKIN AND REINSTALLED CABIN FLOOR PANEL.
- 8 Apr 2002
Longeron, blown
AFT CARGO COMPARTMENT HAS A LONGERON BLOWN OUT IN THE CENTER OF LONGERON 23 LEFT AT STATION 945. -- FABRICATED AND INSTALLED STRAP.
- 8 Apr 2002
Doubler, blown
AFT CARGO COMPARTMENT DOUBLER AROUND THE SUGAR SCOOP IS BLOWN OUT ON THE BOTTOM AFT AREA AT STATION 965 ABOVE LONGERON 22 LEFT. -- REMOVED DOUBLER. DRILLED UP…
- 8 Apr 2002
Intercostal, cracked
FORWARD CARGO DOOR, INTERCOSTAL CRACKED, LOWER AFT AREA OF DOOR. -- REMOVED AND REPLACED INTERCOSTAL.
- 8 Apr 2002
Skin, corroded
LEFT HORIZONTAL STABILIZER LEADING EDGE HAS CORROSION AROUND SOME OF THE WRAP AROUND SCREWS (CENTER SECTION INBOARD AREA). THERE WAS PREVIOUS BLEND OUT…
- 8 Apr 2002
Skin, corroded
RIGHT HORIZONTAL STABILIZER LEADING EDGE HAS CORROSION AROUND SOME OF THE WRAP AROUND SCREWS (CENTER SECTION INBOARD AREA). THERE WAS PREVIOUS BLEND-OUT…
- 8 Apr 2002
Skin, damaged
FUSELAGE CLASS III DOUBLER NEEDS UPGRADE AT STATION 218 LONGERON 25 LEFT. REMOVED DOUBLER, VERIFIED AS NO CRACKS IN SKIN. INSTALLED DOUBLER. REPAIR PLACED ON…
- 8 Apr 2002
Angle, broken
CORROSION ON LOWER LEG FORWARD SIDE OF ELECTRONIC POWER CENTER PANEL SUPPORT FROM COCKPIT DOOR JAMB TO BANANA PANEL. FOUND ANGLE CRACKED OFF. REMOVED AND…
- 8 Apr 2002
Web, misdrilled
FORWARD CARGO DOOR JAMB WEB AND FRAME AT 427 HAS A DOUBLE DRILLED HOLE BETWEEN LONGERON 29 RIGHT AND LONGERON 28 RIGHT. -- FABRICATED AND INSTALLED REPAIR…
- 8 Apr 2002
Former, cracked
FORMER AT STATION 237 LONGERON 18 LEFT TO 17 LEFT IS CRACKED. -- FABRICATED AND INSTALLED SHIM TO ACHIEVE EDGE DISTANCE.
- 8 Apr 2002
Angle, cracked
VERTICAL STABILIZER LEADING EDGE TAIL TO FUSELAGE DORSAL INTERNAL ANGLE IS CRACKED. REMOVED AND REPLACED ANGLE BRACKET.
- 8 Apr 2002
Web, out of tolerance
REMOVAL AFT CARGO DOOR JAMB LOWER INNER WEB TO FACILITATE OTHER MAINTENANCE. -- OLD WEB FOUND OUT OF LIMITS. INSTALLED NEW WEB.
- 27 Mar 2002
Bracket, corroded
CORROSION ON ANGLE BRACKET FOR FLOOR SUPPORT AT STATION 367 RIGHT SIDE. REMOVED AND REPLACED BRACKET.
- 27 Mar 2002
Intercostal, improper
FORWARD PIT INTERCOASTAL LOCATED BETWEEN LONGERON 28 RIGHT AND 27 RIGHT AND FRAMES 560-579 HAS SEVERAL DIVETS IMPROPERLY BACKED. -- FABRICATED AND INSTALLED…
- 27 Mar 2002
Angle, corroded
CORROSION ON CELING IN E&E BAY FROM STATION 200 TO 218 JUST BELOW THE CUSP LINE NEAR LONGERON 18 LEFT. REMOVED DAMAGED SECTION OF UPPER CUSP ANGLE. FABRICATED…
- 27 Mar 2002
Fitting, damaged
REMOVED FLOOR BEAM END FITTING AT CUSP, STATION 218 LEFT SIDE TO FACILITATE OTHER MAINTENANCE. -- FITTING DAMAGED UPON REMOVAL. INSTALLED NEW FITTING.
- 27 Mar 2002
Fitting, misdrilled
FITTINGS MISDRILLED AT STATION 207 (INTERCOSTAL ATTACH CLIP). -- FABRICATED AND INSTALLED NEW FITTING. LOCATED AND PRIMED AND INSTALLED PARTS.
- 27 Mar 2002
Panel, damaged
DENT DAMAGE ON RUDDER LEADING EDGE STRUCTURE AT STATION ZR70 RIGHT SIDE. MEASURES APPROX 4 INCHES IN LENGTH. FABRICATED AND INSTALLED REPAIR.
- 27 Mar 2002
Gusset, corroded
GUSSET AT STATION 580 IS CORRODED ON INTERCOSTAL. -- FABRICATED AND INSTALLED GUSSET.
- 22 Mar 2002
Panel, corroded
LEFT FLAP TRAILING EDGE PANEL NR 3 HAS MODERATE TO HEAVY CORROSION AROUND FINGER DOUBLERS IN SEVERAL BAYS. FINGER DOUBLERS LOOSE IN SEVERAL AREAS. FABRICATED…
- 22 Mar 2002
Splice, cracked
LONGERON 28 LEFT SPLICE AT STATION 560 IS CRACKED OUT AFT HOLE. -- REMOVED LONGERON SPLICE FITTING. MATCH DRILLED FITTING. FABRICATED AND INSTALLED SHIMS TO…
- 19 Mar 2002
Support, cracked
STATION 980 BY LONGERON 27 RIGHT HAS A CRACKED SUPPORT. -- REMOVED AND REPLACED FLOOR SUPPORT.
- 19 Mar 2002
Fitting, corroded
STATION 945 BETWEEN LONGERONS 28 LEFT AND 27 LEFT HAS A CORRODED SUPPORT FITTING. -- REMOVED AND REPLACED SUPPORT FITTING.
- 19 Mar 2002
Support, cracked
STATION 897 BETWEEN LONGERONS 27 LEFT AND 28 LEFT SUPPORT HAS CORROSION BY A FASTENER. WHILE REMOVING CORROSION, FOUND SUPPORT CRACK. REMOVED AND REPLACED…
- 19 Mar 2002
Frame, corroded
FORMER AT STATION 980 HAS AREA OF LIGHT CORROSION BETWEEN LONGERON 25 THROUGH LONGERON 26 LEFT. FABRICATED AND INSTALLED FORMER AND SPLICES.
- 19 Mar 2002
Fitting, corroded
CUSP SPLICE FITTING AT STATION 229 LEFT SIDE HAS CORROSION. REMOVED AND REPLACED FITTING.
- 19 Mar 2002
Frame, corroded
STATION 965 FRAME HAS LIGHT CORROSION FROM LONGERON 25 LEFT TO 27 RIGHT AFT SIDE. REMOVED AND REPLACED SPLICE.
- 19 Mar 2002
Frame, corroded
STATION 917 FRAME FORWARD SIDE HAS CORROSION FROM LONGERON 28 LEFT TO 29 RIGHT UNDER THE FLOOR SUPPORT. FABRICATED AND INSTALLED FRAME SECTION, REPAIR…
- 19 Mar 2002
Frame, corroded
STATION 832 FRAME AFT SIDE HAS CORROSION BETWEEN LONGERONS 29 RIGHT TO 28 RIGHT. FABRICATED AND INSTALLED FRAME REPAIR SECTIONS.
- 19 Mar 2002
Clip, corroded
AFT CARGO COMPARTMENT UNDERSIDE OF SHOVEL CLIP CORRODED AT STATION 945 LONGERON 26 RIGHT. -- REMOVED AND REPLACED SHOVEL CLIP.
- 19 Mar 2002
Longeron, cracked
FORWARD PIT LONGERON 28 LEFT IS CRACKED UNDER SPLICE AT STATION 552 THROUGH 560. -- REMOVED LONGERON, POSITIONED AND DRILLED, REINSTALLED LONGERON.
- 19 Mar 2002
Frame, corroded
STATION 980 FRAME UPPER -J- CHANNEL HAS AREAS OF LIGHT CORROSION BETWEEN LONGERON 29 LEFT THROUGH LONGERON 28 RIGHT. FABRICATED AND INSTALLED REPAIR ANGLES,…
- 19 Mar 2002
Longeron, corroded
FORWARD PIT, CORROSION ON LONGERON AT STATION 570 LONGERON 30. REMOVED AND REPLACED LONGERON. FABRICATED AND INSTALLED RADIUS STRAP.
- 15 Mar 2002
Longeron, cracked
LONGERON 2 RIGHT AT FUSELAGE STATION 1076 CRACKED AT END. -- REMOVED AND REPLACED WITH REPAIR, NEW LONGERON SPLICE.
- 15 Mar 2002
Longeron, dented
LONGERON 20 LEFT STATION 214 HAS DENT AND HAS CARRY OVER 5735. FABRICATED AND INSTALLED LONGERON SECTION.
- 15 Mar 2002
Frame, corroded
STATION 897 FRAME AT LONGERON 29 RIGHT TO 30 HAS CORROSION ON THE LOWER SURFACE. FABRICATED AND INSTALLED CLIP, REPAIR DOUBLERS, AND SHIMS.
- 22 Feb 2002
Frame, cracked
LEFT HAND LOWER RADOME GUIDE PIN HAS A 1.5 INCH CRACK EMANATING FROM ITS HOLE OUTWARD TO A RIVET. REPAIRED PER SRM 53-01-00 FIGURE 2 SHEET 3, DOUBLER ON AFT…
- 17 May 2001
Fan, failed
IN ROUTE TO DSM WEATHER RADAR FAILED. AIRCRAFT DIVERTED TO OMA. REMOVED AND REPLACED WEATHER RADAR RT AND RT FAN.
- 1 May 2001
Skin, cracked
AT STATION 980 RIGHT, THERE IS A SMALL CRACK EXTENDING FROM A FASTENER BETWEEN LONGERON 14 RIGHT AND 16 RIGHT. REMOVED DAMAGED AREA, FABRICATED FILLERS,…
- 27 Apr 2001
Shear Tie, cracked
RIGHT SIDE SHEAR TIE IS CRACKED AT STATION 980 ABOVE LONGERON 15. REMOVED AND REPLACED SHEAR TIE.
- 27 Apr 2001
Seat Track, damaged
CAPTAINS AFT, INBOARD SEAT TRACK LOCKING HOLES ARE ELONGATED. FABRICATED AND INSTALLED REPAIR STRAP.
- 27 Apr 2001
Frame, cracked
STATION 980 RIGHT SIDE FRAME IS CRACKED ON LOWER LEG AT LONGERON 17 RIGHT. FABRICATED AND INSTALLED DOUBLERS.
- 27 Apr 2001
Seat Track, damaged
CAPTAINS AFT SEAT TRACKS LOCKING HOLES ARE ELONGATED. FABRICATED AND INSTALLED REPAIR STRAP.
- 27 Apr 2001
Seat Track, damaged
F/O''S AFT OUTBOARD SEAT TRACK LOCKING HOLES ARE ELONGATED. FABRICATED AND INSTALLED REPAIR STRAP.
- 24 Apr 2001
Angle, cracked
NR 2 BEAM ON AFT PRESSURE BULKHEAD HAD A CRACKED ATTACH ANGLE. REMOVED ANGLE, FABRICATED, DRILLED, AND INSTALLED NEW ANGLE.
- 24 Apr 2001
Stop Fitting, cracked
AFT CARGO DOOR LOWER CENTER STOP FITTING ON DOOR WAS CRACKED. REMOVED FITTING, DRILLED AND INSTALLED NEW FITTING.
- 24 Apr 2001
Fitting, cracked
AFT CARGO DOOR NR 2 BEAM AFT END FITTING WAS CRACKED. REMOVED FITTING, DRILLED, AND INSTALLED NEW FITTING.
- 24 Apr 2001
Hinge, worn
AFT PRESSURE BULKHEAD DOOR UPPER HINGE LOBES ARE WORN. REMOVED AND REPLACED UPPER HINGE LINK.
- 24 Apr 2001
Bulkhead, cracked
LEFT LOWER VENTRAL DOOR CORNER HAS CRACK INDICATION ON RADIOGRAPH APPROXIMATELY 1.25 INCH LONG. TRIMMED AND LOCATED DOUBLERS IAW SERVICE BULLETIN DC9 53-137.…
- 24 Apr 2001
Fitting, cracked
NR 2 BEAM END FITTING IS CRACKED ON FORWARD END. REMOVED AND REPLACED END FITTING.
- 24 Apr 2001
Pan, cracked
FORWARD CARGO DOOR OUTER PAN IS CRACKED UNDER FORWARD STOP FITTING AREA. FABRICATED AND INSTALLED REPAIR DOUBLER.
- 24 Apr 2001
Intercostal, cracked
INTERCOSTAL WEB IS CRACKED UNDER LOWER FORWARD STOP FITTING. FABRICATED AND INSTALLED INTERCOSTAL.
- 24 Apr 2001
Shear Tie, cracked
LEFT SIDE SHEAR TIE IS CRACKED AT STATION 980 ABOVE LONGERON 15 ON FORWARD SIDE. REMOVED AND REPLACED SHEAR TIE.
- 24 Apr 2001
Shear Tie, cracked
RIGHT SIDE SHEAR TIE IS CRACKED AT STATION 945 BETWEEN LONGERON 15 - 16. REMOVED AND REPLACED SHEAR TIE.
- 24 Apr 2001
Angle, cracked
RIGHT PYLON WEB ATTACH ANGLE CRACKED AT STATION 1038 JUST INBOARD OF AFT ENGINE MOUNT. FABRICATED AND INSTALLED ATTACH ANGLE.
- 24 Apr 2001
Rib, corroded
LEFT WING LOWER RIB CAP HAS MODERATE CORROSION ON UPPER SURFACE INBOARD SIDE AT XRS 91 BETWEEN STRINGER 17 AND 22. FABRICATED AND INSTALLED REPAIR DOUBLERS.
- 24 Apr 2001
Attach Angle, cracked
RIGHT HAND PYLON UPPER ATTACH ANGLE IS CRACKED, STATION 980. FABRICATED AND INSTALLED ANGLE AND SPLICE STRAPS.
- 15 Mar 2001
Adi, defective
CAPTAINS ADI FOGGED OVER. REMOVED AND REPLACED CAPTAINS ADI, OPS CHECK GOOD.
- 22 Feb 2001
Angle, cracked
FOUND CRACK ON LEFT FRONT SPAR PYLON BULKHEAD ANGLE AT FS 965, 2.75 LONG BETWEEN LONGERON 15-16 LEFT. REMOVED, FABRICATED, LOCATED AND INSTALLED NEW ANGLE.
- 19 Nov 2000
Battery Pack, inoperative
AFTER ENGINE START FLIGHT ATTENDENT COMPLAINED OF STRONG ELECTRICAL SMOKE SMELL AROUND OVERWING EXITS. EMERGENCY AND FORWARD EXIT LIGHTS WOULD NOT STAY ON.…
- 17 Sep 2000
Hi Lok, loose
MKE - LEFT WING LOWER SURFACE HAD 2 FASTENERS LEAKING FUEL AT STR 19 BETWEEN STA 214 - STA 240. REMOVED FASTENERS, REMOVED TO OVERSIZE AND FABRICATED REPAIR…
- 1 Sep 2000
Smoke, detected
DFW - FLT 310 - SMOKE NOTED IN CABIN. INSPECTED APU AREA FOR LEAKS, NONE FOUND. POWERED UP AIRCRAFT, FOUND RIGHT AIR CONDITIONED PACK SWITCH ON IN AUTO WITH…
- 19 Jul 2000
Battery Pack, discharged
MKE - FOUND EMERGENCY LIGHTS ARM AND CHARGE CIRCUIT BREAKER WAS TRIPPED, RESET IT AND IT TRIPPED AGAIN. FOUND 2 BATTERY PACKS FAULTY, REMOVED AND REPLACED…
- 23 May 2000
Battery Pack, inoperative
AFT EMERGENCY FLOOR TRACK LIGHTING INOP. REMOVED AND REPLACED AFT EMERGENCY BATTERY PACK.
- 14 Apr 2000
Coalescer Bag, contaminated
SMOKE DETECTOR WENT OFF IN LAVATORY, FLIGHT ATTENDANT NOTED SMOKE IN LAVATORY. MAINTENANCE FOUND OIL INGESTED INTO AIR CONDITIONING PACK FROM THE APU,…
- 12 Apr 2000
Pan, chafed
AFT CARGO DOOR OUTER PAN SKIN CHAFED IN 3 PLACES AT DOOR STOPS. FABRICATED AND INSTALLED DOOR PAN.
- 14 Mar 2000
Seat Track, corroded
NR 4 SEAT TRACK AND UNDERSIDE OF UPPER LEG HAS MODERATE CORROSION ON IT FROM STATION 200 TO STATION 237. FABRICATED AND INSTALLED SEAT TRACK AND SPLICES.
- 14 Mar 2000
Floorboard, corroded
FORWARD EDGE OF FLOORBOARD AT STATION 237 BETWEEN NR 3 AND NR 4 SEAT TRACKS ARE MODERATLY CORRODED. FABRICATED AND INSTALLED FLOORBOARD.
- 14 Mar 2000
Longeron, corroded
LIGHT CORROSION AROUND FASTENERS IN LONGERON 28 RIGHT FROM STATION 646 TO 670. FABRICATED AND INSTALLED NEW LONGERON.
- 14 Mar 2000
Floorbeam, cracked
SUB FLOOR CRACKED, 6 INCHES TO THE LEFT OF CENTER AT STATION 200. FABRICATED AND INSTALLED DOUBLER.
- 14 Mar 2000
Frame, cracked
FRAME 617 LONGERON 24 RIGHT THRU 30 CRACK ON OUTBOARD END. FABRICATED AND INSTALLED NEW DOUBLER.
- 14 Mar 2000
Keelbeam, cracked
STATION 691 AT LONGERON 30 HAS A CRACK AT FOURTH FASTENER, CRACK IS ON THE WEB KEEL WEB. FABRICATED AND INSTALLED REPAIR DOUBLER.
- 14 Mar 2000
Angle, corroded
SERVICE DOOR JAMB AT THE CUSP LINE HAS AN ANGLE THAT IS CORRODED HEAVY AT STATION 200 STATION 207. FABRICATED AND INSTALLED NEW ANGLE.
- 14 Mar 2000
Angle, corroded
LIGHT CORROSION ON ANGLE AT STATION 691 ATTACHED TO RIGHT SIDE OF KEEL WEB. FABRICATED AND INSTALLED ANGLE.
- 14 Mar 2000
Vane, chafed
LEFT FLAP INBOARD FIXED VANE OUTBOARD CLOSEOUT PANEL CHAFED ALONG UPPER AFT EDGE. FABRICATED AND INSTALLED NEW DOUBLER.
- 14 Mar 2000
Floorbeam, corroded
REMOVED FLOORBEAM RIGHT BUTTLINE 20-40 AT STATION 200 AND FOUND TO BE CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOORBEAM.
- 14 Mar 2000
Floor Support, cracked
SUB FLOOR CRACKED RIGHT SIDE 7.5 INCHES OUTBOARD OF NR 3 SEAT TRACK AND 2.5 INCHES FORWARD OF STATION 218. FABRICATED AND INSTALLED SUB FLOOR SECTION.
- 14 Mar 2000
Seat Track, corroded
FLOOR SUPPORT BETWEEN CENTER LINE, AND NR 3 SEAT TRACK AT STATION 200 HAS MODERATE CORROSION. FABRICATED AND INSTALLED NEW FLOOR SUPPORT.
- 14 Mar 2000
Floor Support, gouged
SUB FLOOR GOUGED 3 INCHES AFT OF STATION 180 NEAR RIVET HOLES IN LINE OF NR 4 SEAT TRACK. FABRICATED AND INSTALLED SECTION OF FLOORBOARD.
- 14 Mar 2000
Rib, cracked
RIGHT ELEVATOR MOST INBOARD RIB ANGLE LOWER FORWARD SIDE CHAFED AND CRACKED. FABRICATED AND INSTALLED NEW RIB.
- 14 Mar 2000
Door Frame, corroded
CORROSION ON ELECTRIC AND ELECTRONICAL CEILING AT STATION 200 AT RIGHT OUTBOARD CORNER. FABRICATED AND INSTALLED NEW CUSP SECTION, JAMB, AND REPAIR SPLICES.
- 14 Mar 2000
Clip, corroded
MODERATE CORROSION ON FORMER AT STATION 691 AT RIGHT SIDE OF KEEL BEAM. REMOVED AND INSTALLED NEW CLIP.
- 14 Mar 2000
Fitting, corroded
END FITTING ON LONGERON 29 RIGHT AFT OF STATION 604 HAS MODERATE CORROSION ON INNER ATTACHMENT AROUND RIVETS AND ON UPPER INBOARD LEG. FABRICATED AND…
- 14 Mar 2000
Longeron, corroded
LONGERON 29 RIGHT HAS LIGHT TO MODERATE CORROSION AROUND ATTACH RIVETS FROM STATION 622 TO 637. FABRICATED AND INSTALLED LONGERON.
- 14 Mar 2000
Floor Support, cracked
SUB FLOOR CRACKED 1 INCH BELOW STATION 180 AND 25.5 INCHES TO THE LEFT OF THE CENTER. FABRICATED AND INSTALLED DOUBLER.
- 14 Mar 2000
Floorboard, corroded
FORWARD EDGE OF FLOORBOARD AT STATION 237 BETWEEN NR 4 SEAT TRACK AND SIDEWALL MODERATELY CORRODED. FABRICATED AND INSTALLED DOUBLER.
- 14 Mar 2000
Skin, chafed
GALLEY SERVICE DOOR INNER SKIN JUST BELOW BAYONET IS BEING CHAFED BY THE ROLLER BROKEN ON AFT DOOR JAMB. FABRICATED AND INSTALLED DOUBLER.
- 14 Mar 2000
Beam, cracked
GALLEY SERVICE DOOR LOWER BEAM FORWARD END IS CRACKED IN OUTER RADIUS. FABRICATED AND INSTALLED NEW FITTING.
- 14 Mar 2000
Floor Support, cracked
SUB FLOOR CRACKED OUT AROUND RIVET HOLE AT STATION 200, 5.5 INCHES OUTBOARD OF NR 3 SEAT TRACK. FABRICATED AND INSTALLED FILLER AND DOUBLER.
- 14 Mar 2000
Skin, corroded
MODERATE CORROSION ON LOWER FUSELAGE SKIN LEFT OF LONGERON 30 AT STATION 579. FABRICATED AND INSTALLED FILLER AND DOUBLER.
- 14 Mar 2000
Seat Track, corroded
NR 3 SEAT TRACK AND UNDERSIDE OF UPPER LEG HAS MODERATE CORROSION ON IT FROM STATION 200 TO STATION 237. FABRICATED AND INSTALLED SEAT TRACK.
- 14 Mar 2000
Web, cracked
LEFT ELEVATOR CRACK ON FITTING, INBOARD PART OF LEADING EDGE ON BOTTOM SIDE. FABRICATED AND INSTALLED NEW RIB.
- 13 Mar 2000
Frame, cracked
FRAME 658 LONGERON 26 RIGHT 30 CRACKED ON OUTBOARD END. FABRICATED AND INSTALLED DOUBLER.
- 27 Jan 2000
Oven, smoke
RIGHT HAND GALLEY STARTED TO SMOKE DURING FLIGHT. FLIGHT ATTENDANT TURNED OFF OVEN AND SMOKE IMMEDIATELY STOPPED. MTC CHECKED AND RAN OVENS FOR SEVERAL…
- 19 Jan 2000
Cover, dislodged
FORWARD GALLEY DOOR SLIDE COVER CAME OFF. MTC REINSTALLED GALLEY DOOR SLIDE COVER.
- 3 Jan 2000
Engine, surges
MKE - FLT 279 - DURING TAKEOFF ROLL, RIGHT ENGINE HAD A COMPRESSOR SURGE. DISCONTINUED TAKEOFF. MTC INSPECTED INLETS AND EXHAUST, NO DEFECTS NOTED. MTC THEN…
- 3 Jan 2000
Engine, malfunctioned
DURING TAKEOFF ROLL, RIGHT ENGINE HAD A COMPRESSOR SURGE. DISCONTINUED TAKEOFF. SUSPECTED SNOW/SLUSH WENT INTO ENGINE. MTC INSPECTED INLETS AND EXHAUST, NO…
- 21 Dec 1999
Bulb, failed
AFT OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. MTC RELAMPED AFT OVERHEAD EMERGENCY EXIT LIGHT.
- 8 Nov 1999
Relay, failed
MCI - FLT 580 - SMELLED ELECTRICAL SMOKE IN COCKPIT PRIOR TO DEPARTURE. MTC DEFERRED APU AND REMOVED AND REPLACED LEFT APU POWER RELAY. (X)
- 13 Sep 1999
Control Cable, frozen
AILERONS VERY DIFFICULT TO MOVE DURING DESCENT, FEELS FROZEN. MTC FOUND ICE BUILD-UP IN LEFT WHEEL WELL FORWARD TOP OUTBOARD AILERON CABLE/PULLEY STACK. MTC…
- 22 Jul 1999
Cover, disconnected
GALLEY DOOR SLIDE COVER FELL OFF, REINSTALLED.
- 6 Jul 1999
Engine, bird strike
SMOKE IN CABIN AND COCKPIT DUE TO INGESTION OF A BIRD. MAINTENANCE FOUND BIRD STRIKE ON NR 1 ENGINE AND PERFORMED FOREIGN OBJECT DAMAGE INSPECTION.
- 3 May 1999
Slide, low pressure
THE GALLEY DOOR SLIDE PRESSURE GAUGE IS LOW AT 2500 PSI. MAINTENANCE REMOVED AND REPLACED GALLEY DOOR SLIDE.
- 19 Apr 1999
Skin, misdrilled
FOUND MISDRILLED HOLE AT FS 313 BETWEEN LONGERON 28 AND 29R ON FUSELAGE SKIN. MTC FABRICATED AND INSTALLED DOUBLER.
- 19 Apr 1999
Skin, misdrilled
THE SHEAR TIE AT FS 313 BETWEEN LONGERON 28 AND 29R IS MISDRILLED THROUGH SKIN. MTC FABRICATED AND INSTALLED DOUBLER.
- 19 Apr 1999
Tip, damaged
THE RIGHT ELEVATOR TIP HAD TEMPORARY DOUBLER INSTALLED. MTC REMOVED TEMPORARY DOUBLER AND INSTALLED PERMANENT.
- 17 Apr 1999
Fitting, corroded
AFT CARGO DOOR AFI I/B STOP FITTING CORRODED AROUND AND UNDER RADIUS BLOCK. INSTALLED NEW FITTING AND FABRICATED REPAIR DOUBLER.
- 17 Apr 1999
Frame, corroded
AFT PIT FLOOR FRAME STA 813 LOWER SIDE HAS SEVERAL AREAS OF CORROSION FROM 28R TO 27L. BLENDED CORROSION, INSTALLED REPAIR SPLICE.
- 16 Apr 1999
Skin, corroded
BULGING AFT BAG AT BELLY SKIN AROUND HI-LOKS AT SKIN SPLICE. FABRICATED AND INSTALLED NEW BELLY SKIN.
- 14 Apr 1999
Frame, corroded
THE AFT PIT FLOOR FRAME AT STATION 832 AFT LOWER SIDE HAS SEVERAL AREAS OF CORROSION FROM 29R TO 29L. MAINTENANCE FABRICATED AND INSTALLED REPAIR SPLICE PARTS.
- 14 Apr 1999
Tee, corroded
STATION 760 TEE IS BLENDED BEYOND LIMITS BETWEEN LONGERON 28 & 29L. MTC FABRICATED AND INSTALLED NEW TEE SECTION.
- 13 Apr 1999
Fitting, corroded
THE RIGHT KEEL AT STATION 756 BATHTUB FITTING HAS A HEAVY CORROSION. MTC FABRICATED AND INSTALLED NEW FITTING.
- 12 Apr 1999
Longeron, corroded
FOUND HEAVY CORROSION ON LONGERON 30 FROM STATION 804 TO 950. MTC FABRICATED, INSTALLED LONGERON AND -9 FITTING.
- 9 Apr 1999
Fitting, cracked
THE RIGHT AFT WHEEL WELL JAMB TO KEEL FITTING IS CRACKED. MTC FABRICATED, INSTALLED NEW FITTING, REMOVED AND REPLACED SHANKED OUT BOLT.
- 7 Apr 1999
Intercostal, damaged
REMOVED INTERCOSTAL FROM STATION 754 70 AT LONGERON 28 R DUE TO HEAVY TOOL MARKS. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 6 Apr 1999
Battery Pack, discharged
THE MAIN CABIN CEILING EMERGENCY LIGHTS ARE INOPERATIVE FROM ROW 11 TO ROW 14. MTC REMOVED AND REPLACED EMERGENCY BATTERY PACK BATTERIES.
- 5 Apr 1999
Longeron, chafed
LONGERON 22L AT STATION 1010 IS CHAFED. FABRICATED AND INSTALLED DOUBLER REPAIR.
- 29 Mar 1999
Beam, cracked
FOUND CRACK ON FORWARD PASSENGER DOOR ON NUMBER 1 BEAM FORWARD END. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 18 Jan 1999
Skin, dented
FUSELAGE SKIN DENTED AT STATION 890 TO 897 BETWEEN LONGERON 24 AND 25 LEFT. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 18 Jan 1999
Shear Tie, cracked
FUSELAGE FRAME AT STATION 896 SHEAR TIE CRACKED AT AFT FASTENER ROW ABOVE LONGERON 24 LEFT. MTC FABRICATED AND INSTALLED NEW SHEAR TIE.
- 10 Jun 1998
Skin, dented
FOUND SLIGHT DENT ON SKIN AT FS 294 BELOW LONGERON 25L. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 10 Jun 1998
Skin, dented
FUSELAGE SKIN IS DENTED AT FS 351 BELOW LONGERON 26L. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 10 Jun 1998
Skin, dented
THE FUSELAGE SKIN IS DENTED AT FS 370 ABOVE LONGERON 20L. MTC FABRICATED AND INSTALLED REPAIR DOUBLER.
- 10 Jun 1998
Skin, dented
THE FUSELAGE SKIN IS DENTED AT FS 442 AT LONGERON 22L. MTC FABRICATED AND INSTALLED REPAIR DOUBLER.
- 10 Jun 1998
Shear Tie, dented
THE SHEAR TIE IS DENTED INWARD AT STATION 294 BETWEEN L20L AND L19L. MTC SPLICED IN NEW SECTION.
- 10 Jun 1998
Shear Tie, cracked
THE SHEAR TIE CRACKED AT STATION 351 BETWEEN LONGERON 26L AND 27L. MTC SPLICED IN NEW SECTION.
- 10 Jun 1998
Longeron, dented
LONGERON 22L IS DENTED BETWEEN STATION 427 AND 446. MTC SPLICED IN LONGERON SECTION.
- 10 Jun 1998
Longeron, dented
LONGERON 23L IS DENTED AT FS 300. MTC SPLICED IN NEW LONGERON SECTION.
- 10 Jun 1998
Longeron, cracked
LONGERON 24L IS CRACKED AT FS 450. MTC SPLICED IN LONGERON SECTION.
- 10 Jun 1998
Skin, dented
FUSELAGE SKIN IS DENTED AT FS 451 BELOW LONGERON 24L. MTC FABRICATED AND INSTALLED DOUBLER.
- 10 Jun 1998
Skin, dented
FUSELAGE SKIN IS DENTED AT FS 351 AT LONGERON 22L. MTC FABRICATED AND INSTALLED DOUBLER.
- 10 Jun 1998
Skin, dented
THE FUSELAGE SKIN IS DENTED AT FS 300 ABOVE AND BELOW LONGERON 23L. MTC FABRICATED AND INSTALLED REPAIR DOUBLER.
- 10 Jun 1998
Skin, dented
THE FUSELAGE SKIN IS DENTED AT FS 296 BETWEEN LONGERON 19 AND 20L. MTC FABRICATED AND INSTALLED REPAIR DOUBLER.
- 10 Jun 1998
Skin, dented
FUSELAGE SKIN IS DENTED AT FS 214 ABOVE LONGERON 21L AND AT STATION 218 BETWEEN LONGERON 24 AND 25L. MTC FABRICATED AND INSTALLED REPAIR DOUBLERS.
- 10 Jun 1998
Longeron, dented
LONGERON 25L IS DENTED INWARD APPROXIMATELY .125 INCH AT STATION 452. MTC SPLICED IN NEW SECTION OF LONGERON.
- 25 May 1998
Intercostal, cracked
FOUND CRACK ON PASSENGER DOOR INTERCOSTAL AFT OF INTERIOR HANDLE MECHANISM. MTC REMOVED AND REPLACED INTERCOSTAL.
- 25 May 1998
Rib, corrosion
FOUND CORROSION ON RIGHT WING LEADING EDGE RIB AT NUMBER 3 SLAT DRIVE TRACK. MTC FABRICATED AND INSTALLED NEW FITTING.
- 25 May 1998
Pan, cracked
FOUND CRACK ON AFT ENTRANCE DOOR PAN AT UPPER RIGHT STOP FITTING. MTC FABRICATED AND INSTALLED NEW UPPER DOOR PAN.
- 12 May 1998
Batteries, discharged
THE LEFT ENTRANCE WAY PORTABLE LIGHT BATTERY CONTACTS FOUND BAD. MAINTENANCE REPLACED BATTERIES.
- 10 May 1998
Skin, cracked
FOUND CRACK ON RIGHT HAND SKIN AT FS 990 BELOW LONGERON 14R. MAINTENANCE REMOVED DAMAGED SKIN AND FABRICATED AND INSTALLED REPAIR DOUBLERS.
- 7 May 1998
Annunciator, malfunctioned
THE FIRST OFFICERS MASTER CAUTION ANNUNCIATOR STICKS INTERMITTANTLY IN RESET. MTC REMOVED CLEANED AND REINSTALLED FIRST OFFICERS MASTER CAUTION ANNUNCIATOR.
- 7 May 1998
Spar Cap, corrosion
FOUND CORROSION ON RIGHT WING FRONT SPAR TEE CAP SPLICE PLATE INBOARD OF NUMBER 1 SLAT DRIVE TRACK. MAINTENANCE FABRICATED AND INSTALLED NEW STRAP.
- 6 May 1998
Battery Pack, discharged
BOTH FORWARD OVERWING EMERGENCY EXIT SIGNS DID NOT ILLUMINATE WHEN TESTED. MTC CHARGED THE EMERGENCY BATTERY PACK.
- 5 May 1998
Skin, dented
FOUND SMALL DENT ON SKIN AT LONGERON 18L STATION 210. MTC FABRICATED AND INSTALLED REPAIR DOUBLER.
- 28 Mar 1998
Smoke Goggle, cracked
FOUND SMOKE GOGGLE COMPARTMENT FULL OF WATER. MTC DRAINED COMPARTMENT AND REMOVED AND REPLACED CRACKED GOGGLE.
- 7 Feb 1998
Battery Pack, discharged
DURING INSPECTION, FOUND AFT NACELLE LT EMERGENCY LIGHT INOP. MTC REMOVED AND REPLACED AFT NACELLE LT EMERGENCY LIGHT BATTERY PACK IAW DC9 MM 33-50.
- 16 Jan 1998
Battery Pack, discharged
DURING SERVICE CHECK, FOUND CEILING EMERGENCY LIGHTING INOP AT ROWS 15 THROUGH 19. MTC REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT STATION 826.
- 7 Dec 1997
Skin, erroded
DURING C-CHECK, FOUND ERROSION FASTENERS ON LEADING EDGE OF VERTICAL STABILIZER JUST BELLOW Q BELLOWS PITOT TUBE. MTC INSTALLED REPAIR IAW SRM 55-01 PG 7.
- 7 Dec 1997
Skin, cracked
DURING C-CHECK, FOUND RT RUDDER SKIN CRACKED AND DENTED AT STA ZR122. MTC INSTALLED DOUBLER REPAIR IAW SRM 55-03 FIG 11, RECAL WT AND BAL IAW SRM 55-40-1.
- 6 Dec 1997
Frame, cracked
DURING C-CHECK, FOUND CANTED FRAME STA 1089 HAS 2 .5 INCH CRACK AT LONGERON 5R. MTC INSTALLED DOUBLER REPAIR IAW SRM 53-01 FIG 2 SHEET D.
- 6 Nov 1997
Battery Packs, discharged
DURING SERV CHK REAER SECTION EMERG LIGHTS INOP -- MTC REPLACED BATTERY PACKS IN RT LAV
- 24 Aug 1997
Socket, inoperative
DURING TRANSIT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHT AT ROW 10 INOP. MTC INSTALLED NEW SOCKET ASSY AT ROW 10K, OPS CHECK GOOD.
- 4 Jun 1997
Battery Pack, discharged
DURING SERV CHECK, AFT EMERG LIGHT WOULD NOT SHUTOFF. BUSES OFF, EMERG LIGHT SWITCH OFF. MAINT REPLACED BATTERY PACK.
- 3 Jun 1997
Batteries, discharged
DURING SERV CHECK, AFT AISLE OVERHEAD EMERG LIGHTING INOP. MAINT REPLACED BATTERIES.
- 28 Mar 1997
Engine, failed
RT ENG LOW OIL PRESS ANNUNCIATOR LIGHT CAME ON WITH MASTER CAUTION LIGHT ENG SHUT DOWN AS QUANTITY REACHED ZERO. MAINT REMOVED AND REPLACED RT ENGINE.
- 25 Mar 1997
Cover, not secure
PASS DOOR SLIDE COVER POPPED OFF. MAINTENANCE REINSTALLED DOOR SLIDE COVER.
- 10 Feb 1997
Fuel Control, leaking
MAINT REPORTS, APU LEAKING AT FUEL CONTROL CAUSING SMOKE IN CABIN. MAINT REMOVED AND REPLACED APU FUEL CONTROL UNIT.
- 3 Feb 1997
Wire, broken
DURING TAKEOFF, ENGINE EPR DROPPED FROM 1.86 TO 1.4 PRIOR TO REACHING 60 KTS. ABORTED TAKEOFF AND RETURNED TO GATE. MAINT FOUND BROKEN WIRE BEHIND EPR…
- 31 Jan 1997
Augmentation Vlv, inoperative
LEFT ICE PROTECTION TEMP HIGH ANNUN ILLUMINATED, FOLLOWED SHORTLY BY LEFT AIR CONDITIONING SUPPLY TEMP HIGH ANNUN. DIVERTED TO MKE FROM OMA. MAINT REMOVED AND…
- 18 Jan 1997
Power Supply, inoperative
DURING C-CHECK, FOUND AFT ACCESS EMERGENCY LIGHTS, OVRWING EXIT EMERGENCY LIGHTS AND FWD OVERHEAD LIGHTS EXTINGUISHED DURING LIGHT TEST. MAINT REMOVED AND…
- 1 Jan 1997
Battery, discharged
DURING SERVICE CHECK, FOUND EMERGENCY FLOOR TACK LIGHTING FROM ROW 14 AFT INOP. MAINTENANCE REMOVED AND REPLACED BATTERY POWER SUPPLY, OPS CHECK GOOD.
- 26 Nov 1996
Power Supply, inoperative
DURING SERVICE CHECK, FOUND AFT EMERGENCY LIGHTS WOULD NOT TEST. REMOVED AND REPLACED BATTERY PWR SUPPLY, OPS CHECK GOOD.
- 18 Nov 1996
Power Supply, inoperative
DURING A-CHECK, FOUND AFT ACCESSORY COMPARTMENT EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED BATTERY PWR SUPPLY, OPS CHECK GOOD.
- 25 Sep 1996
Flashlight, broken clip
CREW REPORTS, FWD ENTRANCE DOOR EMERGENCY FLASHLIGHT INOP DUE TO BROKEN LOWER CLIP. REPLACED FWD ENTRANCE EMERGENCY FLASHLIGHT, OPS CHECK GOOD.
- 6 Sep 1996
Battery Pack, discharged
EMERGENCY FLOOR LIGHTING INOP IN AFT ACCESSORY COMPARTMENT. REPLACED BATTERY PACK.
- 5 Sep 1996
Batteries, discharged
CREW REPORTS CABIN MEGAPHONE INOP. MAINTENANCE REMOVED AND REPLACED BATTERIES OPS CHK GOOD.
- 27 Aug 1996
Slide, fell off
CREW REPORTS GALLEY SERVICE DOOR EVACUATION SLIDE FELL OFF MOUNT. REINSTALLED GALLEY DOOR EVACUATION SLIDE.
- 15 Aug 1996
Battery Pack, discharged
AFT STATION OF FLOOR EMERGENCY LIGHT INOP. REPLACED FLOOR TRACK BATTERY PACK.
- 3 Jul 1996
Power Supply, inoperative
DURING INSPECTION, FOUND AFT SECTION OF EMERGENCY FLOOR TRACK LIGHTING INOP. REPLACED AFT BATTERY POWER SUPPLY, OPS CHECK GOOD.
- 14 Jun 1996
Frame, corroded
DURING CERT INSP, FOUND HEAVY CORROSION AT THE BOTTOM OF CANTED FRAME AND AREA SKIN OF LT VENTRAL STAIR JAMB AT STA 1143. SPLICED IN A SECTION OF REPAIR ANGLE…
- 14 Jun 1996
Vent Hole, not plugged
DURING CERT MAINTENANCE, VENT HOLE REMAINED AFTER REMOVAL OF AFT GALLEY AT FS 945. REMOVED EXISTING GALLEY VENT AND INSTALLED A PERMANENT REPAIR IAW SRM…
- 14 Jun 1996
Vent Hole, not plugged
DURING CERT MAINTENANCE, VENT HOLE REMAINED AFTER REMOVAL OF AFT GALLEY AT FS 945. REMOVED EXISTING GALLEY VENT AND INSTALLED A PERMANENT REPAIR IAW SRM…
- 14 Jun 1996
Floor Beam, chafed
DURING CERT INSP, A CABIN FLOOR BEAM WAS FOUND CHAFED AT STA 229 UNDER THE LT CENTER FLOOR BOARD. REPAIRED THE FLOOR BEAM IAW 53-05, FIG 20.
- 14 Jun 1996
Floor Beam, chafed
DURING CERT INSP, A CABIN FLOOR BEAM WAS FOUND CHAFED AT STA 541 UNDER LT CENTER FLOORBOARD. REPAIRED THE FLOOR BEAM IAW SRM 53-05, FIG 20.
- 14 Jun 1996
Door Pan, corroded
DURING CERT INSP, FOUND BOTTOM OF THE AFT CARGO DOOR PAN WITH CORROSION. REPAIRED AFT CARGO DOOR PAN IAW SRM 53-05, FIG 44.
- 14 Jun 1996
Intercostal, corroded
DURING CERT INSP, FOUND CORRODED INTERCOSTAL ON UPPER FLANGE IN SEVERAL AREAS AT STA 908 THROUGH 935 LONGERON 29R. REPLACED INTERCOSTAL IAW SRM 51-30-2.
- 14 Jun 1996
Floor Beam, corroded
DURING CERT INSP, FOUND CABIN CENTER FLOOR BEAM UPPER CHANNEL WITH MODERATE CORROSION FROM STA 917 TO 965. REPLACED THE SECTION OF FLOOR BEAM IAW SRM 53-01,…
- 14 Jun 1996
Skin, damaged
DURING CERT INSP, REPAIR MOD OF VHF ANTENNA REQUIRES INSTALLATION AT STA 470, LONG 30. INSTALLED PERMANENT REPAIR ON VHF ANTENNA PER SB 53-188 AND SRO 9530005.
- 14 Jun 1996
Bulkhead Angle, corroded
DURING CERT INSP, FOUND AFT CARGO COMPT BULKHEAD ANGLE HAD LIGHT CORRSION ON UNDERSIDE AT STA 996 FROM LONGERONS 25R TO 18R. SPLICED IN A NEW ANGLE IAW THE…
- 14 Jun 1996
Bracket, cracked
DURING CERT INSP, FOUND AN AFT RT BRACKET CRACKED ON RT INTERCOSTAL AT STA 996.0. FABRICATED A NEW BRACKET IAW SRM 53-01, PAGE 1 AND INSTALLED IAW SRM 53-01,…