N204GL
2014 Waco Classic Aircraft Corp 2T-1A-2 standard FAA →
registration
- 2014
earlier registrations
1 past record
- 1996
service difficulty reports
18 reports
- 13 Jan 2004
Circuit Board, failed
NR 1 AND NR 2 ENVIRO FAILS, REMOVED AND REPLACED A130 PCB. OPS CK GOOD.
- 27 Feb 2003
Tube, disconnected
RIGHT BLEED AIR FAIL. RECONNECTED EVA TUBING ON LT INBOARD WING, OPS CHECK GOOD.
- 21 Feb 2003
Display, inoperative
NR 2 EADI SCREEN FAILED, REPLACED EADI OPS CHECKED SYSTEM SATISFACTORY
- 17 Jan 2003
Cap, broken
NOSE GEAR ACTUATOR CAP BROKE. REMOVED AND REPLACED NOSE GEAR.
- 27 Nov 2002
Transmitter, malfunctioned
RT N1 & TORQUE FLUCTUATIONS, R&R N1 TACH & TORQUE TRANSMITTER
- 11 Oct 2002
Tube, damaged
RT BLEED FAIL ANNUNCIATOR ILLUMINATED AFTER TAKE OFF, THEN RT & LT ENVIRONMENTAL FAIL ANNUNCIATOR ILLUMINATED, REPAIRED RT INSTRUMENT AIR TUBE
- 11 Oct 2002
Tube, failed
AFTER TAKE OFF LT & RT ENVIRONMENTAL FAIL ANNUNCIATORS ILLUMINATED WITH LT BLEED ON AND RT BLEED OFF, REPAIRED RIGHT INSTRUMENT AIR TUBE OPS CHECKED…
- 18 Aug 2002
Governor, out of adjust
LEFT PROP LIMITED TO 1650 ON TAKEOFF ROLL. ADJUSTED LEFT HAND PROP GOV.
- 29 Jul 2002
Tube, disconnected
SMOKE COMING FROM LEFT NACELLE. INSPECTED FOUND VENT TUBE DISCONNECTED. RESECURED, OPS CHECKED SATISFACTORY.
- 25 Jun 2002
Door, leaking
THE 6C EMERGENCY EXIT LEAKS. REMOVED AND REPLACED EMERGENCY DOOR.
- 2 Mar 2002
Tach Generator, fluctuates
LEFT N1 INDICATOR FLUCTUATING. REPLACED TACH GEN, OPS CHECKED SYSTEM SATISFACTORY.
- 7 Feb 2002
Control Handle, inoperative
LANDING GEAR WOULD NOT EXTEND ELECTRICALLY. REPLACED GEAR SELECT HANDLE, OPS CHECKED SYSTEM SATISFACTORY.
- 11 Dec 2001
Seal, out of adj
CABIN DEPRESSURIZED ON CLIMB. RE-INSTALLED DOOR SEAL IN TRACK, OPS CHECKED SYSTEM SATISFACTORY.
- 6 Dec 2001
Line, cracked
RIGHT BLEED AIR FAIL INFLIGHT. REPAIRED EVA TUBING AND REPLACED INSTRUMENT LINE.
- 21 Oct 2001
Downlock Switch, failed
LANDING GEAR WARNING HORN SOUNDS CONTINUOUSLY. REPLACED RIGHT MAIN GEAR DOWNLOCK SWITCH, OPS CHECKED SYSTEM SATISFACTORY.
- 20 Sep 2001
Inverter, malfunctioned
CAPTAINS EADI FLICKERS. REPLACED INVERTER, OPS CHECKED SYSTEM SATISFACTORY.
- 15 Jun 2001
Light, inoperative
RIGHT MAIN LANDING GEAR ANNUNCIATOR INOPERATIVE. REPLACED LIGHT BULB.
- 5 Jun 2001
Indicator, fluctuates
PROP RPM FLUX. REPLACED LEFT INDICATOR.