N203ME
1975 McDonnell Douglas DC-9-32 standard FAA →
earlier registrations
1 past record
- 1975
NTSB
- 31 Jan 2000
incident, Milwaukee WI
service difficulty reports
166 reports
- 24 Oct 2003
Wire, broken
EMERGENCY LIGHTS NOT WORKING. FOUND BROKEN WIRE AND REPAIRED.
- 12 Jul 2003
Yoke, corroded
EVIDENCE OF CORROSION AND GALLING INSIDE LOWER HALF OF RIGHT PYLON MOUNT YOKE CUP. REMOVED AND REPLACED RIGHT ENGINE YOKE MOUNT.
- 14 Oct 2002
Skin, dented
FUSELAGE SKIN IS DENTED AT STATION 1080 AND LONGERON 22R. FABRICATED AND INSTALLED REPAIR DOUBLER, SMOOTHED OUT TOOL MARKS.
- 14 Oct 2002
Door Frame, corroded
AFT CARGO DOOR JAMB WEB HAS SURFACE CORROSION AT SEVERAL LOCATIONS. BLENDED CORROSION, LOCATED FASTENER HOLES IN NEW WEB AND INSTALLED NEW WEB.
- 14 Oct 2002
Door Frame, corroded
CORROSION ON LOWER END OF DOOR JAMB BETWEEN STATION 987-935 IN AFT CARGO BAY. BLENDED CORROSION, REMOVED FASTENERS IN LOWER JAMB SECTION, REMOVED DAMAGED…
- 14 Oct 2002
Panel, corroded
CABIN OVERWING RIGHT SLANT PANEL HAS CORROSION IN THE LOWER RIGHT OUTBOARD PANEL AREA. FABRICATED AND INSTALLED NEW SLANT PANEL.
- 14 Oct 2002
Door Frame, corroded
FORWARD CARGO DOOR JAMB PAN AT LONGERON 28 HAS LIGHT CORROSION ALONG ENTIRE LENGTH. REMOVED CORROSION, REMOVED LOWER DOOR JAMB PAN, LOCATED AND DRILLED NEW…
- 11 Oct 2002
Frame, corroded
FORWARD PIT FRAME 503 CORRODED BEYOND LIMITS ON THE AFT SIDE AT LONGERON 30. REMOVED DAMAGED SECTION OF FRAME, FABRICATED REPAIR PLATES, DRILLED UP NEW FRAME…
- 11 Oct 2002
Door Frame, corroded
AFT CARGO DOOR JAMB BEAM FROM STATION 897-935 AT LONGERON 29 RIGHT HAS CORROSION AT NUTPLATE HOLES. BLENDED CORROSION, REMOVED, FABRICATED AND INSTALLED…
- 8 Oct 2002
Doubler, cracked
SKIN DOUBLER CRACKED AT STATION XE156 FORWARD OF LOWER SPAR CAP. TRIMMED OUT DAMAGE, FABRICATED AND INSTALLED FILLERS, REMOVED AND INSTALLED FASTENERS.
- 8 Oct 2002
Spar Cap, cracked
RIGHT ELEVATOR SPAR CAP HAS A CRACK INDICATION APPROXIMATELY .75 LONGERON PROTRUDING FROM A FASTENER HOLE BETWEEN STATION XE 144.4 AND 156.4. FABRICATED AND…
- 4 Oct 2002
Frame, corroded
FORWARD PIT FRAME 484 CORRODED AROUND FASTENERS AT EACH LONGERON FROM 27 LEFT TO 27 RIGHT. REMOVED DAMAGED SECTION, LOCATED AND DRILLED, FABRICATED AND…
- 2 Oct 2002
Frame, corroded
FORWARD PIT FRAME 446 CORRODED AFT SIDE BETWEEN LONGERON 30 AND 29. CUT OUT DAMAGE, FABRICATED AND INSTALLED FILLER, DOUBLER AND REPAIR ANGLE.
- 17 Sep 2002
Smoke, detected
SMOKE COMING FROM THE RIGHT ENGINE. INSPECTED ENGINE, NO LEAKS FOUND OR SIGNS OF FIRE IN ENGINE COWL, NO DEFECTS NOTED.
- 8 Feb 2002
Skin, cracked
AFT CARGO DOOR SKIN BY DOOR HANDLE HAS A CRACK. FABRICATED AND INSTALLED REPAIR SCUFF PLATE.
- 8 Feb 2002
Skin, dented
DENT IN FUSELAGE SKIN AT STATION 237 BELOW LONGERON 18 LEFT REQUIRES THE PANE REMOVED FOR EVALUATION. TRIMMED INTERNAL DOUBLER IAW TELEX MWX-ORD-02-00019H.…
- 8 Feb 2002
Strap, cracked
LEFT UPPER SPAR STRAP HAS CRACK INDICATION. MUST PERFORM MAGNETIC PARTICLE INSP IAW DC9 54A031 REV 8 FIG 3. REMOVED AND REPLACED BN FASTENER AND CRACKED PYLON…
- 8 Feb 2002
Pan, dented
FORWARD CARGO DOOR INNER PAN IS DENTED FROM THE FORWARD DOOR HINGE. -- FABRICATED AND INSTALLED REPAIR DOUBLER. ALSO FOUND HINGE SUPPORT FITTING BOLT ATTACH…
- 8 Feb 2002
Floorboard, chafed
FLOORBOARD IS CHAFING ON SUBFLOOR BETWEEN AIRCRAFT CENTER LINE AND NR 2 SEAT TRACK STATION 200 TO 218. FABRICATED AND INSTALLED DOUBLER.
- 8 Feb 2002
Floorboard, chafed
FLOORBOARD IS CHAFING ON SUBFLOOR AT STATION 218 BETWEEN NR 3 AND 4 SEAT TRACKS. FABRICATED AND INSTALLED REPAIR DOUBLER.
- 8 Feb 2002
Longeron, damaged
STATION 308 ON LONGERON 1 HAS A DEEP GOUGE FROM A STANDOFF. REMOVED AND REPLACED LONGERON SECTION AND SPLICES.
- 8 Feb 2002
Stiffener, cracked
RIGHT UPPER VENTRAL DOOR CORNER STIFFENER BEAM ATTACH ANGLE IS CRACKED, LOCATED BETWEEN LONGERON 3 AND 4 RIGHT ON AFT PRESSURE BULKHEAD FORWARD SIDE. REMOVED…
- 8 Feb 2002
Skin, tool damage
STATION 699 TO 718 AT LONGERON 6 RIGHT, FUSELAGE SKIN (INTERNAL) HAS FOUR DIRLL START MARKS AND A GOUGE. -- FABRICATED AND INSTALLED SKIN REPAIRS.
- 8 Feb 2002
Frame, gouged
STATION 813 FRAME BELOW LONGERON 5 RIGHT HAS A DEEP GOUGE AND SOME SMALLER GOUGES. FABRICATED AND INSTALLED REPAIR FILLER AND PLATE.
- 8 Feb 2002
Skin, cracked
FUSELAGE SKIN IS CRACKED AT STATION 990 JUST BELOW LONGERON 14 RIGHT. -- FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER.
- 8 Feb 2002
Skin, cracked
FUSELAGE SKIN IS CRACKED AT STATION 990 JUST BELOW LONGERON 14 LEFT. -- REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER AND FILLER.
- 8 Feb 2002
Former, cracked
FORWARD SIDE OF AFT PRESSURE BULKHEAD, FIRST FORMER UP FROM FLOOR, LEFT SIDE IS CRACKED AT OUTBOARD END IN RADIUS, STATION 996. -- FABRICATED AND INSTALLED…
- 8 Feb 2002
Former, cracked
FORWARD SIDE OF AFT PRESSURE BULKHEAD, THIRD FORMER UP FROM FLOOR, LEFT SIDE IS CRACKED IN RADIUS AT OUTBOARD END. STATION 996. -- FABRICATED AND INSTALLED…
- 8 Feb 2002
Former, cracked
FORWARD SIDE OF AFT PRESSURE BULKHEAD, FIRST FORMER UP FROM FLOOR ON RIGHT SIDE IS CRACKED IN RADIUS AT OUTBOARD END, STATION 996. -- FABRICATED AND INSTALLED…
- 8 Feb 2002
Former, cracked
FORWARD SIDE OF AFT PRESSURE BULKHEAD, THIRD FORMER UP FROM FLOOR ON RIGHT SIDE, IS CRACKED IN RADIUS AT OUTBOARD END. STATION 996. -- FABRICATED AND…
- 8 Feb 2002
Shear Tie, cracked
FRAME STATION 945, SHEAR TIE HAS A CRACK LOCATED BETWEEN LONGERON 14 RIGHT AND 15 RIGHT. FABRICATED AND INSTALLED SHEAR TIE.
- 8 Feb 2002
Skin, cracked
FUSELAGE SKIN AFT OF FRAME STATION 945 HAS A CRACK LOCATED BETWEEN LONGERON 14 RIGHT AND 15 RIGHT. FABRICATED AND INSTALLED REPAIR DOUBLER.
- 8 Feb 2002
Shear Tie, cracked
SHEAR TIE AT BULKHEAD FRAME STATION 965 HAS A CRACK LOCATED BETWEEN LONGERON 16 RIGHT AND 17 RIGHT. FABRICATED AND INSTALLED SHEAR TIE.
- 8 Feb 2002
Longeron, cracked
STATION 699 LONGERON LEFT 3 CRACKED. -- FABRICATED AND INSTALLED HAT SECTION REPAIR SPLICE, FILLER, AND SPLICES.
- 8 Feb 2002
Longeron, cracked
STATION 699 LONGERON 4 LEFT IS CRACKED. -- FABRICATED AND INSTALLED REPAIR SPLICE AND FILLER INSTALLED.
- 8 Feb 2002
Longeron, cracked
STATION 699 LONGERON 5 LEFT IS CRACKED. -- FABRICATED AND INSTALLED LONGERON SECTION AND SPLICES.
- 8 Feb 2002
Longeron, cracked
STATION 699 LONGERON 6 LEFT IS CRACKED. -- FABRICATED AND INSTALLED LONGERON RADIUS BLOCKS, TWO SPLICES, AND ONE LONGERON FILLER.
- 8 Feb 2002
Pan, gouged
RIGHT AFT EMERGENCY EXIT DOOR JAMB IS GOUGED AT STATION 658 LONGERON 12 RIGHT. REMOVED AND REPLACED DOOR JAMB PAN.
- 8 Feb 2002
Frame, damaged
STATION 680 FRAME HAS THREE OPEN HOLES BETWEEN LONGERON 17 LEFT AND 18 LEFT. -- FABRICATED AND INSTALLED FREEZE PLUG AND RADIUS BLOCKS.
- 8 Feb 2002
Tee Fitting, cracked
CRACKED TEE FITTING ON PAX DOOR AT AFT END OF BEAM #3 (3RD FROM BOTTOM). -- REMOVED AND REPLACED TEE FITTING.
- 8 Feb 2002
Intercostal, gouged
GOUGES ON TOP OF INTERCOSTAL AT STATION 726 ABOUT 10 INCHES RIGHT OF CENTER FLOOR SUPPORT CABIN AREA. FABRICATED AND INSTALLED DOUBLER STACK REPAIR.
- 8 Feb 2002
Intercostal, gouged
GOUGE ON TOP OF INTERCOSTAL AT STATION 708 ABOUT 10 INCHES RIGHT OF CENTER FLOOR SUPPORT CABIN AREA. FABRICATED AND INSTALLED DOUBLE ANGLE REPAIR.
- 8 Feb 2002
Web, cracked
RIGHT MAIN LANDING GEAR WHEEL WELL FORWARD UPPER KEEL WEB TO SLANT PANEL ANGLE CRACKED. -- REMOVED AND REPLACED ANGLE FITTING.
- 8 Feb 2002
Frame, damaged
STATION 658 FRAME HAS TWO HOLES IN INBOARD RADIUS OF FRAME BETWEEN LONGERON 17 LEFT AND 18 LEFT. -- FABRICATED AND INSTALLED RADIUS BLOCK AND CLIP.
- 8 Feb 2002
Floorboard, dented
FLOORBOARD B11 IS DENTED AT THE FORWARD RIGHT CORNER. -- FABRICATED AND INSTALLED REPAIR DOUBLER.
- 8 Feb 2002
Rib, corroded
RIGHT WING TANK -XRS 189 WING RIB LOWER CAP HAS LIGHT CORROSION ON UPPER INBOARD SURFACE FROM FORWARD SPAR TO STRINGER 19. BLENDED OUT AREA TO 1.0 INCH RADIUS…
- 8 Feb 2002
Rib, corroded
RIGHT WING TANK -XRS 189 WING RIB LOWER CAP HAS LIGHT CORROSION ON LOWER SURFACE FROM STRINGER 17 TO 13. BLENDED OUT AREA TO 1.0 INCH RADIUS IAW DAC TELEX…
- 8 Feb 2002
Panel, cracked
METALLIC FLOOR PANEL B8, HAS A FASTENER HOLE CRACKED AND ON THE SAME END THE OTHER CORNER IS CRACKED OFF WITH A BROKEN RIVET HEAD NEAR BY. -- FABRICATED AND…
- 8 Feb 2002
Rib, corroded
LEFT WING FUEL TANK STATION XRS 164, RIB HAS LIGHT CORROSION IN AREA ON OUTBOARD SIDE FROM AFT SPAR TO STRINGER. COMPLIED WITH PER BOEING TELEX…
- 8 Feb 2002
Fitting, unserviceable
REMOVED FITTING FROM LEFT KEEL AREA AT STATION 604 TO FACILITATE OTHER MAINTENANCE. -- INSTALLED NEW FITTING.
- 8 Feb 2002
Splice, misdrilled
STRINGER SPLICE BETWEEN KEEL BEAM AND LONGERON 29 LEFT FUSELAGE STATION 658 ABD 667 HAS DOUBLE DRILLED HOLES. -- INSTALLED NEW SPLICE.
- 8 Feb 2002
Intercostal, cracked
INTERCOSTAL AT LONGERON 7 RIGHT, FUSELAGE STATION 256, HAS A HOLE WHICH IS CRACKED ON THE AFT END. -- REMOVED AND REPLACED INTERCOSTAL AND ANGLE.
- 8 Feb 2002
Fitting, cracked
FITTING IS CRACKED, LOCATED AT FUSELAGE STATION 1038 UPPER INBOARD CORNER. -- FABRICATED AND INSTALLED FITTING.
- 8 Feb 2002
Stringer, corroded
CORROSION AND BARE METAL ON STRINGER AT STATION 604 TO 622. STRINGER IS LOCATED BETWEEN KEEL AND LONGERON 29 LEFT. REMOVED AND REPLACED HAT CHANNEL AND…
- 8 Feb 2002
Longeron, cracked
LONGERON 4 LEFT IS CRACKED AT STATION 160. -- FABRICATED AND INSTALLED LONGERON SECTIONS AND REPAIR SPLICES.
- 23 Jan 2002
Frame, chafed
CANTED FRAME AT STATION 1168 HAS A CHAFED AREA ON LOWER AFT SIDE AT 7 O'CLOCK POSITION. -- FABRICATED AND INSTALLED REPAIR DOUBLERS.
- 23 Jan 2002
Intercostal, cracked
LONGERON 8 RIGHT, INTERCOSTAL AT STATION 292 HAS A CRACK BY A FASTENER. FABRICATED AND INSTALLED REPAIR DOUBLER.
- 23 Jan 2002
Doubler, cracked
SUBFLOOR REPAIR DOUBLER CRACKED AT STATION 160 AND CENTER OF FLOOR, FWD SIDE OF STATION 160 AS VIEWED FROM BELOW. FABRICATED AND INSTALLED DOUBLER.
- 23 Jan 2002
Pan, cracked
FORWARD CARGO DOOR INNER PAN IS CRACKED BY THE AFT DOOR HINGE LOWER FLANGE. -- FABRICATED AND INSTALLED REPAIR DOUBLER.
- 23 Jan 2002
Pan, cracked
AFT CARGO DOOR INNER PAN HAS LIGHT CORROSION BETWEEN BEAMS NR 1 THROUGH NR 2 (FWD LEFT BOTTOM). MAINTENANCE FOUND CRACK IN LIP OF PAN. FABRICATED AND…
- 23 Feb 2001
Intercostal, cracked
INTERCOSTAL CRACKED AT FS 1040 ABOVE LONGERON 16 RIGHT. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLERS, LOCATED AND INSTALLED.
- 22 Jan 2001
Skin, dented
FOUND DENT ON SKIN AT STATION 105 LEFT SIDE LONGERON 19. REMOVED DAMAGED AREA, FABRICATED, LOCATED, DRILLED, AND INSTALLED DOUBLER.
- 22 Jan 2001
Skin, damaged
DRILL START IN OUTER SKIN ABOUT 3 INCHES FORWARD OF FRAME STATION 598 JUST BELOW WINDOW BELT PANEL. REMOVED DAMAGE AND FLUSH PLUGGED IAW SUBMITTAL…
- 22 Jan 2001
Longeron, cracked
INSIDE CABIN RIGHT LAV HAD CRACKED LONGERON STATION 965, LONGERON 17 RIGHT. REMOVED DAMAGED LONGERON, SPLICED AND INSTALLED.
- 22 Jan 2001
Skin, damaged
WINDOW FRAME CORRODED AND PITTED STATION 503 - 522, ZONE 2 AND 15 LEFT WINDOW. REMOVED DAMAGED WINDOW BELT SECTION, LOCATED, DRILLED, AND INSTALLED NEW SECTION.
- 22 Jan 2001
Shear Tie, cracked
INSIDE CABIN FORWARD OF RIGHT LAV HAD A CRACKED SHEAR CLIP AT STATION 945 BETWEEN LONGERONS 15 - 16 RIGHT. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED…
- 18 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGE, FUSELAGE LOWER SECTION AT STATION 190 BETWEEN LONGERON 29 - 30 LEFT. BLENDED AND REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR…
- 18 Jan 2001
Longeron, cracked
INSIDE CABIN, LEFT LAV HAS A CRACKED LONGERON AT STATION 965, LONGERON 16 LEFT. FABRICATED AND INSTALLED NEW LONGERON.
- 16 Jan 2001
Frame, cracked
FRAME AT STATION 980 IS CRACKED AT LONGERON 16 LEFT. REMOVED DAMAGE, FABRICATED NEW FRAME AND REPAIR SPLICES.
- 16 Jan 2001
Shear Tie, cracked
SHEAR CLIP IS CRACKED AT STATION 980 BELOW LONGERON 14 LEFT. REMOVED DAMAGED PART, FABRICATED AND INSTALLED SHEAR TIE.
- 16 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGE AT FUSELAGE LOWER SECTION BETWEEN STATION 216 - 229 AND LONGERON 29 LEFT AND LONGERON 30 LEFT. BLENDED AREAS AT STATION 219 OUT OF…
- 16 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGE BOTTOM SIDE OF FUSELAGE BETWEEN STATION 260 - 284. BLENDED AREA, REMOVED DAMAGED RIVET, INSTALLED NEW RIVET. REMOVED DAMAGED AREA BY…
- 16 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGED, BOTTOM SIDE OF FUSELAGE BETWEEN STATION 287 - 313, LONGERON 28 LEFT AND 29 LEFT. BLENDED AREA, REMOVED DAMAGE BY DRILLING, INSTALLED…
- 16 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGE TO RIVETS AND SKIN BETWEEN STATION 416 - 427 BETWEEN LONGERON 24 LEFT AND 25 LEFT. REMOVED DAMAGED RIVETS, BLENDED DAMAGED AREA,…
- 16 Jan 2001
Skin, damaged
LIGHTNING STRIKE DAMAGED AT STATION 541 LONGERON 25 LEFT. REMOVED DAMAGED RIVET, BLENDED AREA, INSTALLED OVERSIZED RIVET.
- 16 Jan 2001
Longeron, cracked
AREA OF LEFT HAND LAVATORY HAD CRACKED LONGERON AT STATION 980. REMOVED DAMAGED SECTION, LOCATED, DRILLED, AND INSTALLED NEW LONGERON.
- 16 Jan 2001
Angle, cracked
LEFT HAND LOWER PYLON ATTACH ANGLE IS CRACKED AT STATION 980. REMOVED CRACKED ANGLE, LOCATED, DRILLED, AND INSTALLED NEW ANGLE.
- 10 Jan 2001
Longeron, cracked
LEFT LAV HAD CRACKED LONGERON, UPPER FLANGE AT STATION 965, LONGERON 16 LEFT. FABRICATED AND INSTALLED NEW LONGERON SECTION.
- 6 Dec 2000
A/C Pack, failed
AFTER DEPARTURE FROM MCI AT 6800 FT THE LEFT PACK SHUTDOWN. JUST PRIOR TO SHUTDOWN CREW NOTED EXTREMELY WARM AIR IN COCKPIT. RETURNED TO MCI. -- DEFERRED LEFT…
- 16 Nov 2000
Warning Light, illuminated
UPON CLIMBOUT FROM DSM FORWARD AIRSTAIR OPEN ANNUNCIATOR CAME ON. RETURNED TO DSM. DES MOINES FLYING SERVICE CHECKED AIRSTAIR, OPERATIONAL AND PRESSURE CHECK…
- 6 Sep 2000
Rudder, restricted
MKE - FLT 3 - DURING TAXI CHECK OF FLIGHT CONTROLS, THE RUDDER TRAVEL FELT RESTRICTED IN BOTH DIRECTIONS. MAINTENANCE COULD NOT DUPLICATE THIS DISCREPANCY.…
- 17 Feb 2000
Cover, loose
SPLIT PIN FOR FORWARD ENTRANCE DOOR EMERGENCY EVACUATION SLIDE COVER CAME OFF. MAINTENANCE REINSTALLED SLIDE COVER.
- 31 Jan 2000
Heater, malfunctioned
FLIGHT CREW NOTICED SMOKE COMING FROM THE LEFT LAVATORY AT THE GATE. EVIDENCE OF ELECTRICAL FIRE. MTC REMOVED AND REPLACED LAV WATER HEATER, FLUSH TIMER,…
- 16 Jan 2000
Skin, corroded
RIGHT HAND AILERON ON INBOARD SKIN IS CORRODED UNDER CHAFE PLATE IN SEVERAL AREAS. MTC FABRICATED AND INSTALLED FILLER AND DOUBLER.
- 11 Jan 2000
Floorboard, cracked
RIGHT SIDE CABIN FLOORBOARDS MARKED F4 AND E6 HAVE SEVERAL CRACKS NEAR THE ENDS. MTC FABRICATED AND INSTALLED DOUBLERS.
- 29 Dec 1999
Retainer, cracked
FOUND LEFT FLAP OUTBOARD HINGE RETAINERS (2 EACH) WERE CRACKED INSIDE OF FLAP. MAINTENANCE FITTED AND INSTALLED NEW RETAINERS.
- 29 Dec 1999
Angle, gouged
FORWARD CARGO DOOR HAD GOUGE ON INNER PAN NEAR AFT LOCKING TORQUE TUBE. MAINTENANCE FABRICATED AND INSTALLED REPAIR ANGLE.
- 29 Dec 1999
Longeron, corroded
FORWARD CARGO PIT, LONGERON 29 LEFT, HAS MODERATE CORROSION AT STATION 337. MAINTENANCE FABRICATED AND INSTALLED NEW SECTION OF LONGERON.
- 23 Dec 1999
Splice, corroded
MODERATE CORROSION AROUND RIVETS IN CHANNEL OF LONGERON 30, STATION 351-370. MAINTENANCE FABRICATED AND INSTALLED NEW SPLICE.
- 20 Dec 1999
Longeron, corroded
INTERCOSTAL LONGERON 28 RIGHT STATION 980-996 CORROSION OUT OF LIMITS. MAINTENANCE FABRICATED AND INSTALLED NEW LONGERON.
- 20 Dec 1999
Floorbeam, corroded
NUMEROUS NUT PLATES HAVE CORROSION ON UNDERSIDE ON THE FORWARD AND AFT GILLINER SUPPORT STRUTS AT FUSELAGE 917 TO 996 AND 943-996. SUPPORT BETWEEN FUSELAGE…
- 18 Dec 1999
Splice, cracked
FORWARD CARGO COMPARTMENT CORROSION ON LONGERON 30 DOUBLER AT STATION 407 TO 419. MAINTENANCE REMOVED CORROSION AND FOUND CRACK AT LONGERON 30 SPLICE.…
- 18 Dec 1999
Splice, corroded
DUE TO NRI 18870 AND 18909, SPLICE IS REQUIRED ON LONGERON 30 AT STATION 375. MAINTENANCE FABRICATED AND INSTALLED NEW LONGERON SPLICE.
- 18 Dec 1999
Frame, corroded
FORWARD CARGO COMPARTMENT CORROSION ON TOP OF FRAME UNDER FLOOR SUPPORT AND UNDER NUTPLATES AT STATION 333. MAINTENANCE FABRICATED AND INSTALLED NEW PLATE FOR…
- 16 Dec 1999
Longeron, misrepaired
CORROSION ON END OF TIE CLIP AT FUSELAGE STATION 995, LONGERON 22 LEFT. LONGERON 22 LEFT BLENDED OUT OF LIMITS. MAINTENANCE FABRICATED AND INSTALLED SPLICE…
- 16 Dec 1999
Floorbeam, chafed
FLOORBEAM CHAFFED THROUGH AT FUSELAGE STATION 917. MAINTENANCE FABRICATED AND INSTALLED FLOORBEAM.
- 16 Dec 1999
Floorbeam, chafed
HEAVY CHAFING ON FLOORBEAM ABOVE FORWARD CARGO DOOR STATION 389. MAINTENANCE FABRICATED AND INSTALLED FLOORBEAM.
- 16 Dec 1999
Shear Tie, corroded
CORROSION ON SHEARTIE AT STATION 897 ABOVE LONGERON 30. MX DRILLED AND INSTALLED SHEARTIE.
- 14 Dec 1999
Skin, cracked
LEFT WING LOWER SURFACE INBOARD OF STATION 164 AFT OF REAR SPAR, THE SKIN IS CRACKED. MAINTENANCE FABRICATED AND INSTALLED PANEL, SKIN AND BUET DOOR.
- 14 Dec 1999
Structure, damaged
REMOVE TEMPORARY REPAIR STRAP AND FASTENER FROM DAMAGED HOLE AT XRS 91.000. MX REMOVED TEMPORARY REPAIR, THEN FABRICATED AND INSTALLED DOUBLER.
- 13 Dec 1999
Frame, chaffing
LEFT FORWARD OVERWING EXIT FRAME CHAFFING AT CENTER TOP WHERE DOOR LATCHES. MAINTENANCE FABRICATED AND INSTALLED DOUBLER.
- 21 Oct 1999
Rib, damaged
FIRST AND SECOND RIB OF THE RIGHT HAND WING TRAILING EDGE, INBOARD OF THE END CAP AND CHANNEL, DAMAGED. MTC REMOVED AND REPLACED FIRST AND SECOND RIB AS…
- 21 Oct 1999
Rib, damaged
RIGHT HAND TRAILING EDGE PANEL, AND RIB CAP DAMAGED ON OUTBOARD FLAP. MTC REMOVED AND REINSTALLED RIB.
- 21 Oct 1999
Skin, damaged
RIGHT HAND FLAP OUTBOARD REMOVABLE TRAILING EDGE PANEL LOWER SKIN DAMAGED. MTC REMOVED AND REPLACED SKIN.
- 1 Aug 1999
Gauge, out of position
PRESSURE GAUGE ON GALLEY SLIDE VERY DIFFICULT TO SEE. REPOSITIONED GALLEY SLIDE.
- 5 Jul 1999
Skin, cracked
LEFT PYLON UPPER SKIN STIFFENER IS CRACKED ABOVE 13TH STAGE BLEED DUCT INSIDE PANEL 8103A. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 1 Jul 1999
Girt Bar, stuck
THE AFT SERVICE DOOR GIRT BAR IS STUCK. MAINTENANCE REPOSITONED AFT GALLEY SLIDE COVER.
- 9 Jun 1999
Transceiver, inoperative
EN ROUTE TO MCO, THE WEATHER RADAR STOPPED PAINTING WEATHER, AND DISPLAYED A R/T FAIL ON THE SCREEN. REMOVED AND REPLACED THE RADAR R/T UNIT.
- 20 Mar 1999
Skin, cracked
FOUND SKIN CRACKED AT STATION 37 L1. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.
- 6 Feb 1999
Spar, damaged
FOUND DAMAGED HOLE AT RIGHT WING STATION 109.0 AFT SPAR. MTC INSTALLED TEMPORARY REPAIR STRAP.
- 25 Jan 1999
Skin, cracked
FOUND SMALL FAIRING LIFTING AND RIVETS PULLING THROUGH SKIN ON AFT OUTBOARD CORNER OF RIGHT ELEVATOR. MTC FABRICATED AND INSTALLED NEW DOUBLER AND SKIN.
- 15 Jan 1999
Fitting, cracked
FOUND CRACK ON AFT CARGO DOOR BEAM END FITTING. MTC FABRICATED AND INSTALLED NEW END FITTING.
- 23 Oct 1998
Battery Pack, discharged
FOUND LEFT AND RIGHT FORWARD WING OVERHEAD EMERGENCY EXIT SIGN INOPERATIVE. MTC REMOVED AND REPLACED EMERGENCY BATTERY PACK.
- 11 Oct 1998
Proximity Switch, failed
LEFT UNSAFE RED GEAR LIGHT REMAINS ON WITH GEAR HANDLE IN UP POSITION. MTC REMOVED AND REPLACED LEFT MLG UP LIMIT SWITCH AND PROXIMITY SWITCH CONTROL BOX.
- 19 Jun 1998
Light, inoperative
FOUND FORWARD ENTRANCE EMERGENCY LIGHT INOP. MTC REMOVED AND REPLACED FORWARD ENTRANCE EMERGENCY LIGHT ASSEMBLY.
- 9 Mar 1998
Battery Pack, discharged
DURING SERVICE CHECK, FOUND LT NACELLE EMERGENCY LIGHT INOPERATIVE. MTC REMOVED AND REPLACED LT NACELLE BATTERY PACK.
- 2 Mar 1998
Bulkhead Web, elongated holes
THE AFT PRESSURE BULKHEAD WEB HAS 3 ELONG HOLES ON LT SIDE DOOR JAMB STA Z34 TO 48. MTC FABRICATED REPAIR DOUBLER AND BUSHINGS IAW SVC MSP-0172/PDG ATA…
- 20 Feb 1998
Skin, corroded
INSPECTION FOUND CORROSION UNDER THE LEFT WING FINGER DOUBLERS ON LOWER SKIN INSIDE TRAILING EDGE PANEL. REPLACED SKIN IAW EA NR 57-006.
- 9 Feb 1998
Skin, corroded
DURING INSPECTION, FOUND LIGHT CORROSION ON EXTERIOR SURFACE OF LOWER SKIN ON RIGHT ELEVATOR XE 157.9. MTC REPAIRED IAW SRM 55-03 FIG 14 SHEET 2 AND SRM 51-30.
- 9 Feb 1998
Bulkhead, corroded
DURING INSPECTION, FOUND LIGHT CORROSION ON FWD SIDE OF APB LEFT SIDE FROM APPROXIMATELY LONG 26L TO 28L. MTC REPAIRED IAW SRM 53-03 FIG 9 SHEET 1 AND 51-30-5.
- 9 Feb 1998
Seat Track, corroded
DURING INSPECTION, FOUND HEAVY CORROSION ON GALLEY SEAT TRACK NR 4 FROM STATION 200 TO 240. MTC REPAIRED IAW SRM 51-30-2 AND SRM 53-05 FIG 4F.
- 8 Feb 1998
Fairing, damaged
DURING INSPECTION, FOUND THE RT FLAP FIXED VANE FAIRING DAMAGED. MTC REPAIRED IAW SRM 51-30-2 AND 57-01 FIG 3 SHEET 2.
- 4 Feb 1998
Doubler, cracked
DURING C-CHECK, FOUND A CRACK THROUGH A FASTENER HOLE ON AFT FACE OF STATION 37 BULKHEAD. MTC REPAIRED IAW SRM 53-01 FIG 2.
- 4 Feb 1998
Angle, cracked
DURING C-CHECK, FOUND A CRACKED ANGLE ON LT PYLON STATION 1019. MTC REPAIRED IAW SRM 54-01 FIG 2 AND 51-30-05.
- 2 Feb 1998
Seat Track, corroded
DURING INSPECTION, FOUND GALLEY SEAT TRACK NR 3 IS CORRODED FROM STATION 200 TO STATION 240. MTC REPAIRED IAW SRM 53-05 FIG 40.
- 2 Feb 1998
Angle, cracked
DURING INSPECTION, FOUND THE AFT CARGO DOOR INNER DOOR PAN CRACKED IN FLANGE RADIUS. MTC REPAIRED IAW SRM 51-30-2 AND 51-30-5.
- 19 Jan 1998
Slide Cover, fell off
CREW REPORTS, GALLEY DOOR SLIDE COVER FELL OFF. MTC INSTALLED SLIDE COVER.
- 19 Jan 1998
Slide Cover, fell off
THE GALLEY SLIDE COVER CAME OFF. MTC RESECURED THE SLIDE AND COVER.
- 25 Nov 1997
Battery, discharged
DURING TRANS CHECK, FOUND AFT UPPER EMERGENCY FLASHLIGHT INOP. MTC REMOVED AND REPLACED BATTERY, OPS CHECK GOOD.
- 4 Nov 1997
Temp Sensor, defective
DURING CLIMB, THE AIRCRAFT TEMP HIGH LIGHT STAYED ON WITH SYSTEM OFF. MTC REMOVED AND REPLACED LT AIRFOIL TEMP HIGH SENSOR.
- 7 Aug 1997
Slide Cover, fell off
CREW REPORTS GALLEY DOOR SLIDE COVER BROKE OFF. MAINT REINSTALLED COVER.
- 14 Jun 1997
Frame, chafed
DURING C-CHECK, LT PYLON AFT VERT FRAME CHAFED. MAINT REPAIRED IAW SRM 54-01 FIG 2 SHT 2.
- 14 Jun 1997
Skin, cracked
DURING C-CHECK, RT/LT NLG DOOR AFT HINGE RADIUS OF SKIN CRACKED. MAINT REPAIRED IAW SRM 53-05 FIG 62.
- 14 Jun 1997
Skin, dented
DURING C-CHECK, PAX DOOR UP AFT CORNER SKIN DENTED 1.75 INCH .10 DEPTH. MAINT REPAIRED IAW SRM 52-05 FIG 4.
- 1 Jun 1997
Door, not closed
DURING FLIGHT, ELECTRICAL COMPART DOOR OPEN LIGHT ON. UNABLE TO PRESSURIZE. MAINT CLOSED E AND E COMPARTMENT DOOR.
- 19 Apr 1997
Slide Cover, fell off
EVAC SLIDE COVER ON SERVICE DOOR CAME OFF. MAINTENANCE REINSTALLED SLIDE COVER.
- 29 Mar 1997
Pan, cracked
DURING SERVICE CHECK, FWD CARGO DOOR HAS CRACK ON INNER PAN. MAINT REPAIRED IAW SRM 52-05 FIG 26A.
- 26 Feb 1997
Air Cycle Mach, malfunctioned
PILOT REPORTS, JUST AFTER STARTING AOU AND TURNING ON PACKS THE CABIN FILLED WITH SMOKE. MAINT REMOVED AND REPLACED AIR CYCLE MACHINE AND WATER SEPARATOR.
- 26 Feb 1997
Air Distribution, smoke
AFTER STARTING APU AND TURNING ON THE PACK, CABIN FILLED WITH SMOKE. MAINTENANCE RAN APU OPERATED BOTH PACKS, NO SMOKE NOTED. CHECK OIL IN BOTH ACMS, FOUND…
- 12 Nov 1996
Light, inoperative
DURING SERVICE CHECK FOUND FWD ENTRY EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED FWD ENTRY EMERGENCY LIGHT ASSY. OPS CHECK GOOD. RETURNED…
- 28 Jul 1996
Skin, debonded
TEMPORARY REPAIR INSTALLED ON RT WING TRAILING EDGE UPPER SKIN IAW SRM 57-01, FIG. 2, SHEET 2. INSTALLED PERMANENT DOUBLER REPAIR IAW SRM 57-01, FIG. 2, SHEET…
- 27 Jul 1996
Girt Bar Spring, weak
DURING C-CHECK, FOUND GALLEY SERVICE DOOR GIRT BAR LATCH SPRINGS WEAK. REPLACED GIRT BAR LATCH COMPRESSION SPRINGS.
- 16 Jun 1996
Beam, cracked
DURING INSP, FOUND AFT VENTRAL DOOR HAS CRACK IN LT LOWER BEAM. REPLACED BEAM IAW SRM 51-30.
- 11 May 1996
Beam, cracked
DURING CARGO DOOR INSPECTION, FOUND AFT CARGO DOOR NR 5 HORIZONTAL BEAM CRACKED NEAR AFT END AT PAN CUTOUT, RADIUS 1 .0625 INCH IN LENGTH. INSTALLED DOUBLER…
- 11 May 1996
Former, cracked
DURING CARGO DOOR INSPECTION, FOUND FWD CARGO DOOR FORMER CRACKED IN RADIUS BELOW NR 1 BEAM ABOVE AFT LOWER DOOR STOP. INSTALLED REPAIR IAW SRM 52-01 FIG 2…
- 11 May 1996
Angle, corroded
DURING CARGO DOOR INSPECTION, FOUND FWD CARGO DOOR LOWER AFT INTERNAL ANGLE HAS 1 INCH AREA OF HEAVY CORROSION. SPLICED IN SECTION OF ANGLE IAW SRM 52-01 FIG…
- 2 May 1996
Skin, punctured
AIRCRAFT RECEIVED PUNCTURE IN SKIN WHILE PARKED IN MSN. APPROX .3750 INCH TEAR IN FUSELAGE AT STA 240 BETWEEN LONGERON 19 AND LONGERON 20R. FERRIED AIRCRAFT…
- 28 Apr 1996
Slide Cover, fell off
CREW REPORTS, GALLEY SERVICE DOOR EVACUATION SLIDE COVER FELL OFF. REINSTALLED EVACUATION SLIDE COVER.
- 19 Apr 1996
Cover, fell off
UPON ARRIVAL, GALLEY DOOR EVACUTAION SLIDE COVER FELL OFF DOOR. REINSTALLED GALLEY SERVICE DOOR EMERGENCY EVAC SLIDE COVER.
- 20 Jan 1996
Angle, cracked
DURING C-CHECK, FOUND VERTICAL STAB TO FUSELAGE EXTERIOR ATTACH ANGLE CRACKED ON LT SIDE APPROX 8 INCH FROM AFT END. INSTALLED DOUBLER REPAIR IAW SRM 53-05…
- 20 Jan 1996
Angle, cracked
DURING C-CHECK, FOUND ANGLE AT FS 1076 IN AFT ACCESSORY COMPT CRACKED AT LONGERON 16R. FABRICATED AND INSTALLED ANGLE IAW SRM 53-01.
- 19 Jan 1996
Oven, malfunctioned
CREW REPORTS, CIRCUIT BREAKER FOR LEFT OVEN POPPED. RESET CB, POPPED AGAIN. F/A REPORTS, SMELLING ELECTRICAL SMOKE. REPLACED OVEN AND OPS CHECK GOOD.
- 16 Jan 1996
Slide Cover, fell off
CREW REPORTS, FWD GALLEY DOOR EVACUATION SLIDE COVER CAME OFF. RESECURED GALLEY DOOR SLIDE COVER.
- 11 Nov 1995
Evac Slide, loose
CREW REPORTS, UPON LANDING THE GALLEY SERVICE DOOR EMERGENCY EVACUATION SLIDE BECAME LOOSE. MAINTENANCE RESECURED ESCAPE SLIDE, RETURNED A/C TO SERVICE.
- 21 Oct 1995
Eel, inop
MAINT REPORTED, THE FWD EMERGENCY ENTRANCE LIGHT WILL NOT ILLUMINATE DURING TEST. MAINTENANCE REMOVED AND REPLACED LIGHT ASSEMBLY AND AIRCRAFT RETURNED TO…
- 24 Sep 1995
Portable Fire-X, leaked
FORWARD FLIGHT ATTENDANT'S PORTABLE HALON FIRE EXTINGUISHER, FOUND LEAKED DOWN TO ZERO. REPLACED THE FIRE EXTINGUISHER WITH A SERVICEABLE UNIT.
- 13 Jul 1995
Eel Power Supply, failed
DURING ROUTINE INSPECTION, THE EMERGENCY FLOOR TRACK LIGHTING WAS FOUND TO BE INOP, FROM ROW 18 AFT. MAINTENANCE REMOVED AND REPLACED BATTERY POWER SUPPLY.…
- 22 Jun 1995
Cable, detached
CREW REPORTS, GALLEY SERVICE DOOR GIRT BAR ATTACH CABLE CAME UNATTACHED. MAINTENANCE REATTACHED GIRT BAR CABLE, REINSTALLED SLIDE COVER. RETURNED A/C TO…
- 28 May 1995
Door Frame, cracked
DURING ROUTINE INSPECTION, A 3 INCH CRACK WAS FOUND IN RADIUS OF DOOR FRAME STRUCTURE IN AFT PRESSURE BULKHEAD RT SIDE. MAINTENANCE INSTALLED SPLICE REPAIR…
- 6 May 1995
Lanyard, broken
DURING ROUTINE INSPECTION, THE GALLEY SERVICE DOOR SLIDE COVER LANYARD WAS FOUND BROKEN. REPLACED GALLEY SLIDE COVER LANYARD. RETURNED A/C TO SERVICE.
- 5 May 1995
Antenna, inop
ON TAKEOFF ROLL, GPWS 'PULL UP' SQUAWKED SEVERAL TIMES, CAPT REPORTED SPEED UNDER 60 KNOTS. PULLED OFF TO DEFER (34-29A) AND SILENCE GPWS COMPUTER.…
- 3 Apr 1995
Eel Battery Pack, discharged
CREW REPORTS COCKPIT AND GALLEY CEILING EMERGENCY LIGHTS REMAIN ON WHEN POWER IS REMOVED FROM AIRCRAFT. REPLACED BATTERY POWER PACK NR 1. OPS CHECK GOOD,…
- 11 Mar 1995
Slide Cover, fell off
CREW REPORTS, GALLEY SERVICE DOOR EVACUATION SLIDE COVER CAME OFF. REINSTALLED GALLEY DOOR EVACUATION SLIDE COVER AND RETURNED A/C TO SERVICE.
- 18 Feb 1995
Hinge, cracked
DURING C-CHECK INSP, ON THE LEFT MAIN LANDING GEAR OUTBOARD DOOR HINGE, FOUND 1 HINGE LOBE CRACKED. REPLACED HINGE PER DAC SB 32-244 AND SRM 51-30. A/C…
- 31 Jan 1995
Slide Cover, fell off
PILOT REPORTS GALLEY SERVICE DOOR EVACUATION SLIDE COVER FELL OFF. REINSTALLED SLIDE COVER AND RETURNED A/C TO SERVICE.
- 31 Jan 1995
Girt Bar Latch, dirty
PILOT REPORTS GIRT BAR ON GALLEY SERVICE DOOR SLIDE HARD TO OPERATE. CLEANED AND LUBED GIRT BAR RELEASE. OPS CHECK GOOD. RETURNED A/C TO SERVICE.