N202FR
2008 Airbus A320-214 standard FAA →
registration
- 2008
service difficulty reports
31 reports
- 19 Aug 2021
Latch, out of adjust
DISCREPANCY: LP1199237 ITEM 1: AT APPROXIMATELY 80-90 KNOTS ON TAKEOFF, REFUEL PANEL CAME OPEN. T/O WAS ABORTED. HIGHEST BRAKE TEMP WAS 738. CORRECTIVE…
- 10 Jul 2021
Slide, leaking
R1 SLIDE RESERVOIR PRESSURE IS FOUND OUT OF LIMITS. PER EO # A0-25EO-35106, AD 2020-25-03. REMOVED R1 DOOR SLIDE ASSY IAW AMM 25-62 44-012-A. INSTALLED R1…
- 29 Apr 2021
Line, failed
LP133846 ITEM 1 DISCREPENCY -- HYD Y RSVR LO LVL CORRECTIVE ACTION: REMOVED AND REPLACED #2 ENG YELLOW HCU PIPE REF AMM 29-13-49-000-048-A AND AMM…
- 2 Sep 2019
Unknown, odor
SMELLED BURNING ELECTRIC FOR ABOUT 30 SEC ONLY IN COCKPIT NO SMOKE ASSOCIATED W/SMELL. CONDUCTED VISUAL INSPECTION OF AVIONICS COMPARTMENT AND NO DEFECTS…
- 15 May 2019
Apu, leaking
DISCREPANCY: REFERENCE LP1170958 ITEM#1 - ON DECENT F/A'S NOTICED STRONG ACRID ODOR WAS ALSO NOTICED IN THE COCKPIT. CORRECTIVE ACTION - REF TDI CNTRL#…
- 11 May 2019
Apu, leaking
DISCREPANCY: REFERENCE LP1110900 ITEM 1. FIRST FLT OF THE DAY TURNED APU ON AND A STRONG DIRTY MUSTY SOCK ODOR FILLED THE CABIN. TURNED PACKS OFF AND ODOR…
- 6 Nov 2018
Panel, defective
DISCREPANCY: REFERENCE LOG PAGE LP1112557 ITEM 1, RMP 1 MALFUNCTION VERY STRONG ELECTRICAL ODOR. CORRECTIVE ACTION: REMOVED AND REPLACED 1RG1 RMP REF AMM…
- 24 Oct 2018
Control Cable, corroded
DISCREPANCY: REFERENCE N/R 2168N511 RUDDER LT OUTBOARD CABLE RUSTED LOCATED UNDER DUMMY BEAM Y503.2. CORRECTIVE ACTION: CABLE FWD CONNECTION REMOVED AND…
- 16 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N412, P/R (721615) FLOORBEAM Y765 CORRODED AT FR66-70. CORRECTIVE ACTION: EVALUATED FLOORBEAM Y765 AT FR66-70. REMOVED .030…
- 15 Oct 2018
Beam, cracked
DISCREPANCY: REFERENCE N/R 2168N342 CRACK ON ENG 2 I/B THRUST REVERSER PIVOT FITTING BEAM. CORRECTIVE ACTION: REMOVED AND REPLACED NR 2 ENG I/B THRUST…
- 12 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N291, FLOORBEAM Y1292 CORRODED AT FR16. CORRECTIVE ACTION: EVALUATED FLOORBEAM Y1292 AT FR16 FOUND TO BE OUT OF LIMITS IAW SRM…
- 12 Oct 2018
Floorbeam, corroded
FLOORBEAM -Y1292 CORRODED AT FR16. REMOVED AND REPLACED FLOORBEAM -Y1292 AT FR 16 IAW SRM 51-72-11, SRM 51-74-00, TASK 5-A AND SRM 53-11-14-283-004.
- 12 Oct 2018
Floorbeam, corroded
FLOORBEAM -Y254 CORRODED AT FR16. REMOVED AND REPLACED FLOORBEAM -Y254 AT FR16 IAW SRM 51-72-11 AND SRM 51-74-00 TASK 5-A AND 53-11-14-283-004.
- 11 Oct 2018
Shear Web, corroded
DISCREPANCY: REFERENCE N/R 2168N230, LT FR70 LATERAL SHEAR WEB PLATE AT CABIN FLOOR CORROSION. CORRECTIVE ACTION: EVALUATED LT FR70 SHEAR WEB FOUND TO BE OUT…
- 11 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N241, FLOORBEAM Y254 CORRODED 2 INCHES FWD OF FR66. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM Y254 FR66 IAW SRM…
- 11 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N242, FLOORBEAM -Y765 CORRODED AT FR66-FR70. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM -Y765 FR66 TO FR70 IAW SRM…
- 11 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N233 FWD DUMMY BEAM Y503.2 CORRODED BETWEEN FR12 TO FR16. CORRECTIVE ACTION: DUMMY FLOORBEAM REMOVED AND REPLACED IAW SRM…
- 11 Oct 2018
Door Sill, corroded
DISCREPANCY: REFERENCE N/R 2168N247, R2 DOOR SILL CORRODED AT FWD SPLICE FR66. CORRECTIVE ACTION: REMOVED AND REPLACED R2 DOOR SILL IAW SRM 51-72-11 AND SRM…
- 11 Oct 2018
Door Sill, corroded
DISCREPANCY: REFERENCE N/R 2168N238, L2 DOOR SILL CORRODED AT FR66 FWD SPLICE. CORRECTIVE ACTION: REMOVED AND REPLACED DOOR SILL (L2 DOOR) IAW SRM…
- 11 Oct 2018
Floorbeam, corroded
DISCREPANCY: REFERENCE N/R 2168N246, FLOORBEAM CORRODED BETWEEN FR16 TO FR20. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM IAW 51-72-11-911 AND…
- 25 Jul 2018
Unknown, odor
FLIGHT ATTENDANTS COMPLANIED OF ODOR FUMES DURING TAXI. UPON DEBRIEF THEY SAID THEY COULD SMELL IN DESCENT. DID TRY TO ISOLATE BETWEEN PACK 1 AND 2 DURING…
- 31 May 2018
Unknown, odor
AT FL350 F/AS CALLED AND SMELLED AN ODOR LIKE MUSTY DIRTY SOCKS, ELECTRICAL, NAIL POLISH SWEET ODOR FROM ROW 14 AFT. RAN ELIMINATION OF ODOR IN CABIN /COCKPIT…
- 14 Sep 2016
Proximity Sensor, out of adjust
LANDING GEAR NOT UPLOCKED. LANDING SYSTEM DISAGREE, AIR TURNBACK. POST FLIGHT REPORT SHOWED 25GA NLG EXTENTION PROXIMITY SWITCH IAW TSM 32-31-00-810-842-A AND…
- 3 Sep 2013
Plate, corroded
ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. AFT CABIN LATERAL PLATE HAS CORROSION AT FR 69-70, S23R. R & R SHEAR PLATE IAW SRM 51-42-11, PAR 6, PAR 7, AND PAR 13.
- 27 Aug 2013
Skin, dented
ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. RT FWD FUSELAGE FR 10, STRINGER 23R DENTED. REPAIRED IAW SRM 53-11-11 PB201, PARA 5.J.
- 27 Aug 2013
Skin, gouged
ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. LOWER FUSELAGE AT FR 53, STRINGER 37L, DENTED WITH A GOUGE IN THE CENTER. REPAIRED IAW SRM 53-41-11, PB201.
- 19 Aug 2013
Skin, dented
ACFT OUT OF SERVICE FOR C4/S1 CHECK. DENT FWD OF THE L2 DOOR APPROXIMATELY .054" DEEP, 3.5" LONG, 3.375" WIDE. REPAIRED IAW SRM 53-00-11, PB201, PARA 4.A.
- 29 Oct 2012
Line, chafed
YELLOW SYS LOW LEVEL HYDRAULICS. R & R NR 2 ENGINE HYD LOW PRESSURE SWITCH TUBE. REF AMM 29-13-49-000-005A AND 29-13-49-400-005A. OPS AND LEAK CHECK GOOD.
- 10 Mar 2012
Proximity Switch, failed
MAIN CABIN DOOR DOES NOT SHOW CLOSED ON ECAM WHEN IT IS CLOSED. R & R LT 1 DOOR PROXIMITY SWITCH, OPS CHECK GOOD AMMS2-71-11-401.
- 17 Feb 2012
Girt Bar, out of adjust
R2 DOOR ARMED INDICATION INTERMITTENT. FOUND R2 DOOR GIRT BAR FITTING OUT OF ADJUSTMENT. ADJUSTED R2 DOOR GIRT BAR FITTING AMM 52-13-00-820-057 A.
- 11 Feb 2012
Proximity Switch, failed
L1 DOOR INDICATES OPEN WHEN IT IS CLOSED. R & R L1 DOOR PROXIMITY SWITCH AMM52-71-11, PB 401.