N196CA
1979 Cessna 402C standard FAA →
registration
- 1979
earlier registrations
2 past records
- 1990
- 1959
service difficulty reports
80 reports
- 25 Jun 2025
Rib, cracked
DURING SCHEDULED INSPECTION, A CRACK WAS VISUALLY IDENTIFIED ON THE RIGHT HAND CLOSEOUT RIB LOCATED AT RWS 106.79. THIS CRACK IS LOCATED IN THE FORWARD…
- 20 Dec 2017
Indicator, failed
DURING FLIGHT THE PILOT REPORTED THE WEATHER RADAR SHUT OFF BY ITSELF ACCOMPANIED BY A BURNED PLASTIC ODOR IN THE COCKPIT FOR A SHORT TIME. THE COMPONENT WAS…
- 25 Aug 2016
Exhaust Valve, damaged
CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION. EXHAUST VALVE DISPLAYS EVIDENCE OF HEAT DAMAGE.
- 3 Jun 2016
Exhaust Valve, damaged
CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION. EXHAUST VALVE DISPLAY EVIDENCE OF HEAT DAMAGE.
- 11 Jan 2006
Window Frame, cracked
PILOTS SIDE WINDOW LOWER STRUCTURAL BEAM IS CRACKED AT LEFT WINDSHIELD AFT BEAM. NORMAL OPS. (K)
- 2 Sep 2002
Engine, overtemp
ON CLIMBOUT (LEFT) T6 RAISED WITH POWER REDUCTION. T6 CONTINUED TO RISE TO THE POINT OF T6 WARNING. T6 FINALLY CAME DOWN TO ABOUT 684 DEGREES, PRODUCING NO…
- 17 Aug 2002
Control Box, malfunctioned
LEFT LANDING RED LIGHTS REMAIN ON (A & B) WITH GEAR HANDLE SELECTED. INSTALLED SERVICEABLE LANDING GEAR RELAY BOX ASSY, SWUNG LANDING GEAR 35 PLUS TIMES. OPS…
- 1 Aug 2002
Battery, discharged
DURING TAXI FOR TAKEOFF, FLOOR LEVEL EMERGENCY LIGHTING FROM ROW 6 TO AFT OF AIRCRAFT ILLUMINATED. COULD NOT BE EXTINGUISHED. REPLACED EMERGENCY LIGHT BATTERY…
- 4 Jul 2002
Striker, out of adjust
AFTER TAKEOFF, CARGO DOOR LIGHT ILLUMINATED, MASTER WARNING DOORS AND DOOR CAPTION ON MAP ILLUMINATED. WARNING DOES NOT OCCUR ON GROUND. RETURNED TO RDD.…
- 6 May 2002
Wire Harness, faulty
WITH GEAR HANDLE DOWN THE LANDING GEAR REMAINED UP AND LOCKED. LEFT THE GEAR HANDLE DOWN AND ON GO-AROUND THE LANDING GEAR CAME DOWN AND LOCKED. REPLACED…
- 29 Mar 2002
Battery, discharged
FORWARD FLOOR EMERGENCY LIGHTS ARE OUT. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK PER MM 33-50-02. OPS CHECK GOOD.
- 24 Jan 2002
Wire Harness, malfunctioned
LEFT EEC FAILED ON TAKEOFF. ABORTED TAKEOFF. REMOVED AND REPLACED LEFT ENGINE UPPER WIRE HARNESS IAW POWER PLANT BUILDUP MANUAL 71-00-00. OPS CHECKED IAW MM…
- 12 Dec 2001
Structure, cracked
C-CHECK, PAX DOOR LOWER AFT TRACK, CRACK ON DOOR STRUCTURE. PERFORMED REPAIR ON PASSENGER DOOR UNDER LOWER AFT TRACK PER SB 120-052-0034.
- 14 Nov 2001
Fastener, loose
SERVICE DOOR LIGHT ILLUMINATED ON CLIMB THROUGH 10,000 FEET. LIGHT WENT OUT ON DESCENT WHILE SLOWING. RETURNED TO FAT. FOUND 1 CAMLOCK ON INBOARD FUEL SERVICE…
- 8 Sep 2001
Uplock Sensor, dirty
RIGHT 'A' RED GEAR LIGHT DID NOT EXTINGUISH AFTER TAKEOFF. ALL GEAR DOORS REMAINED OPEN WITH GEAR SELECTED IN UP POSITION. CYCLED AS PER QRH.CLEANED AND…
- 18 Jul 2001
Window Post, cracked
CRACK FOUND IN RIGHT POST BETWEEN DIRECT VIEW WINDOW AND WINDSHIELD.FABRICATED AND INSTALLED DOUBLER IAW SB120-053-0010/3-18-88.
- 6 Feb 2001
Battery, discharged
EMERGENCY LIGHTS WILL NOT STAY ON WHEN TURNED ON. REPLACED FORWARD EMERGENCY LIGHT BATTERY. OPS CHECKS GOOD. P/N ON: D366-04-00, S/N ON: 1213, S/N OFF: 349.
- 5 Feb 2001
Fire Loop, damaged
RIGHT DET INOP ENGINE/WW LIGHT ILLUMINATED INFLIGHT. RETURNED TO LAX. INSTALLED SERVICEABLE ENGINE FIRE DETECTION LOOP ON RIGHT ENGINE IAW MM 26-11-00. OPS…
- 22 Dec 2000
Sequence Valve, malfunctioned
ON DEPARTURE RETRACTED LANDING GEAR, RIGHT MAIN WOULD NOT RETRACT. BOTH A & B RED LIGHTS ILLUMINATED. CREW IN AIRCRAFT BEHIND US NOTED THE RIGHT GEAR WOULD…
- 15 Oct 2000
Actuator, stuck
AT SETTINGS BEYOND 1.0 UNITS NOSE DOWN, ELEVATOR TRIM WHEEL STICKS. THE ELECTRIC TRIM WHEEL ACTUATOR IS INCAPABLE OF OVERCOMING BEING STUCK, BUT IT CAN BE…
- 15 Sep 2000
Harness, chafed
LEFT NH GAUGE BOTH ANALOG AND DIGITAL INOP DURING FLIGHT. ANALOG NEEDLE JUMPING BETWEEN 10 - 70 PERCENT AND DIGITAL JUMPING 90 - 150 PERCENT NH. DIVERTED TO…
- 28 Nov 1999
Uplock, out of adjust
UPON GEAR RETRACTION THE RIGHT MAIN GEAR RED A LIGHT WORLD NOT EXTINGUISH. ALSO HEARD BANGING SOUNDS AND FELT VIBRATION. RETURNED TO FAT. ADJUSTED RIGHT MLG…
- 31 Mar 1999
Pin, bent
RIGHT MAIN FORWARD GEAR DOOR HAS COME UNLATCHED TWO TIMES IN LAST TWO FLIGHTS. STRAIGHTENED LOCK PIN AND FUNCTION APPEARS NORMAL ON GROUND.
- 28 Jun 1998
Lamp, failed
EMERGENCY FLOOR LIGHT AT ROW 9 IS INOPERABLE. REPLACED LAMP.
- 23 Jun 1998
Actuators, malfunction
INBOARD FLAPS ASYMMETRY WARNING DURING TAKEOFF. REPLACED THE INBOARD FLAPS ACTUATORS.
- 16 Jun 1998
Mechanism, malfunctioned
FLAP ASYMMETRY, INBOARD FLAPS WOULD NOT DEPLOY. COULD NOT DUPLICATE DISCREPANCY, SYSTEM OPERATIONAL CHECK SATISFACTORY.
- 6 Apr 1998
Support, cracked
CREW PREFLIGHT INSPECTION FOUND ONE RIVET HEAD BROKEN OFF IN FUSELAGE SKIN, LEFT HAND SIDE, FRAME NR 9, JUST BELOW CAPTAIN'S DV WINDOW. FURTHER INVESTIGATION…
- 21 Dec 1997
Actuator, failed
FLAP CONTROL FAULT WARNING. REPLACED THE RIGHT OUTBOARD FLAP ACTUATOR.
- 4 Nov 1997
Autopilot, malfunctioned
AUTO PILOT AND TRIM FAIL WARNINGS DURING TAKEOFF. DEFERRED AUTO PILOT SYSTEM PER MEL.
- 23 Oct 1997
Angle, cracked
DURING 2C INSPECTION, TASK 5320-244-02I FOUND WING TO FUSELAGE FAIRING ATTACH ANGLE PART NR 120-31657-002 CRACKED. REPAIRED ANGLE IAW APPROVED AERO-DESIGN…
- 22 Oct 1997
T Section, corroded
DURING 2C INSPECTION TASK 141-012 REVEALED LEFT CENTER T-SECTION TO BE CORRODED. REPLACED T-SECTION USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
T Section, corroded
DURING 2C INSPECTION TASK 141-012 REVEALED T-SECTION AT FRAME 23 TO BE CORRODED. REPLACED T-SECTION USING EMB 120 STANDARD PRACTICES.
- 22 Oct 1997
T Section, corroded
DURING 2C INSPECTION TASK 5310-131-01I REVEALED LEFT CENTER T-SECTION TO BE CORRODED BEYOND LIMITS. REPLACED T-SECTION USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Crossbeam, corroded
DURING 2C INSPECTION TASK 151-01Z REVEALED RIGHT FLOOR CROSSBEAM AT FRAME 33 TO BE CORRODED BEYOND LIMITS. REPLACED CROSSBEAM USING EMB120 SRM STANDARD…
- 22 Oct 1997
Crossbeam, corroded
DURING 2C INSPECTION TASK 141-01Z REVEALED FLOOR CROSSBEAMS LEFT AT FRAME 20 AND LEFT AT FRAME 23 (BOTH THE SAME PART NUMBER) TO HAVE CORRODED BEYOND LIMITS.…
- 22 Oct 1997
Crossbeam, corroded
DURING 2C INSPECTION TASK 5310-131-O1I REVEALED LEFT FLOOR CROSSBEAM AT FRAME 15 TO BE CORRODED. REPLACED CROSSBEAM USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION TASK 151-01Z REVEALED RIGHT SILL TO BE CORRODED. REPLACED SILL USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION TASK 5310-141-03I REVEALED LEFT NR 2 SILL TO BE CORRODED. REPLACED SILL USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION TASK 5310-131-01I REVEALED LEFT SILL (UNDER GALLEY) TO BE CORRODED. REPLACED SILL USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION TASK 5310-131-O1I REVEALED RIGHT FLOOR SILL (UNDER LAV) TO HAVE HEAVY CORROSION. REPLACED SILL USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 5320-147-03I REVEALED CENTER BUTTSTRAP TO BE CORRODED. REPLACED BUTTSTRAP USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 161-01Z REVEALED LEFT HAND CARGO BUTTSTRAP TO BE CORRODED. ALSO, FOUND THAT CARGO LINING SCREW HAD BEEN SCREWED INTO STRAP. REPLACED…
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 0 152-01Z, REVEALED LEFT HAND BUTTSTRAP TO BE CORRODED. REPLACED BUTTSTRAP USING EMB SRM STANDARD PRACTICES.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 5310-131-01I REVEALED LEFT BUTTSTRAP TO BE CORRODED. REPLACED BUTTSTRAP USING EMB SRM STANDARD PRACTICES.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 5310-131-01I REVEALED CENTER BUTTSTRAP TO BE CORRODED. REPLACED BUTTSTRAP USING EMB SRM STANDARD PRACTICES.
- 22 Oct 1997
Butt Plate, corroded
DURING 2C INSPECTION TASK 5310-131-01I REVEALED CENTER BUTT PLATE TO BE CORRODED. REPLACED CENTER BUTT PLATE USING APPROVED AERODESIGN REPORT NR 1671-1.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION TASK 161-01Z, FOUND LEFT HAND CARGO THRESHOLD BUTTSTRAP CORRODED BEYOND LIMITS. REPLACED BUTTSTRAP USING EMB 120 SRM STANDARD PRACTICES.
- 22 Oct 1997
T Section, corroded
DURING 2C INSPECTION, TASK 5310-132-O1I FOUND RIGHT FRAME 16 T-SECTION CORRODED BEYOND LIMITS. REPLACED T-SECTION IAW EMB-120 SRM.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION, TASK 162-01Z, FOUND RIGHT FORWARD CARGO SILL CORRODED BEYOND LIMITS. REPLACED SILL IAW EMB-120-SRM.
- 22 Oct 1997
Crossbeam, corroded
DURING 2C INSPECTION, TASK 5320-142-03I, FOUND RIGHT CROSSBEAM AT FRAME 23 CORRODED BEYOND LIMITS. REPLACED CROSSBEAM IAW EMB 120 SRM.
- 22 Oct 1997
Crossbeam, corroded
DURING 2C INSPECTIN TASK 5310-132-01I, FOUND RIGHT CROSSBEAM AT FRAME 16 CORRODED BEYOND LIMITS. REPLACED CROSSBEAM IAW EMB 120 SRM.
- 22 Oct 1997
Buttstrap, corroded
DURING 2C INSPECTION, TASK 5310-132-01I, FOUND NR 1 RIGHT SIDE BUTTSTRAP CORRODED BEYOND LIMITS. REPLACED BUTTSTRAP IAW SRM EMB-120.
- 22 Oct 1997
Control Cable, worn
WHILE PERFORMING TASK 5720-581-01I ON LEFT WING, 2C INSPECTION, FOUND BOTH AILERON CABLES WORN BADLY AT NACELLE FAIRLEADS. REPLACED CABLES IAW EMB 120 MM.
- 22 Oct 1997
Cables, worn
WHILE PERFORMING TASK 5720-681-01I ON RIGHT WING, 2C INSPECTION, FOUND BOTH AILERON CABLES WORN BADLY AT NACELLE FAIR LEADS. REPLACED CABLES IAW EMB 120 MM.
- 22 Oct 1997
Sill, corroded
DURING 2C INSPECTION TASK 161-01Z, FOUND LEFT HAND CARGO FLOOR SILL CORRODED BEYOND LIMITS. REPLACED CORRODED SILL IAW EMB 120 SRM.
- 11 Sep 1997
Circuit Breaker, tripped
'TAKEOFF TRIM' AURAL WARNING SOUNDED DURING TAKEOFF ROLL. AURAL WARNING CIRCUIT BREAKER WAS TRIPPED. RESET BREAKER AND SYSTEM TEST NORMAL.
- 20 Aug 1997
Brake Disk, broken
LEFT BRAKE LOCKED UP WHILE TAXIING OUT TO RUNWAY. FOUND BRAKE DISC HAD BROKEN. REMOVED AND REPLACED BRAKE ASSY WITH SERVICEABLE UNIT.
- 17 Jul 1997
Actuator, malfunction
LT MLG DID NOT INDICATE DOWN AND LOCK WHEN GEAR SELECTED DOWN. CONTROL HANDLE CYCLED AND INDICATION WAS NORMAL. REPLACED THE LEFT HAND MLG UPLOCK ACTUATOR.
- 13 Jul 1997
Sensor, overheated
CREW SMELLED BURNING RUBBER ODOR AND OBSERVED SMOKE COMING FROM COPILOTS INSTRUMENT PANEL. REPLACED OVERHEATED, IOCE PROTECTION CIRCUIT, CURRENT SENSOR.
- 8 Jul 1997
Duct, cracked
LEFT HAND BLEED AIR DUCT LEAK WARNING ON. REPLACED CRACKED BLEED AIR DUCT IN LEFT HAND WING LEADING EDGE.
- 18 May 1997
Inverter, failed
THE NR 1 INVERTER FAILED AND MOMENTS LATER THE NR 2 FAILED. REPLACED THE NR 1 AND 2 STATIC INVERTERS (S/N 3360 AND 5463).
- 18 May 1997
Flap Contl Unit, malfunction
FLAP CONTROL FAULT MESSAGE, INTERMITTENT DISAGREEMENT AND ASYMMETRY WARNINGS. REPLACED THE FLAP CONTROL UNIT.
- 14 Apr 1997
Rccb, overheated
BURNING ODOR IN COCKPIT. REPLACED GROUND COOLING FAN RCCB.
- 22 Mar 1997
Air Speed Ind, inaccurate
20 KNOT DIFFERENCE BETWEEN PILOTS AND CO-PILOTS AIRSPEED INDICATORS. REPLACED PILOTS AIR SPEED INDICATOR.
- 18 Jan 1997
Roller, worn
FLAPS RETRACT SLOWLY AND DISAGREE MESSAGE. REPLACED LEFT AND RIGHT INBOARD FLAP ROLLERS, OPERATIONAL CHECK GOOD.
- 16 Jan 1997
Pneumatic Lines, frozen
HYDRAULIC LOW PRESS LEFT ILLUMINATED. THAWED AND PURGED PNEUMATIC LINES.
- 11 Jan 1997
Hyd System, moisture contam
BOTH LOW PRESS RES L/R AND GREEN SYS INDICATORS WENT TO 0 QUANTITY. THAWED OUT PNEUMATIC LINERS AND PURGED MOISTURE FROM SYS, OPERATIONAL CHECK GOOD.
- 9 Sep 1996
Door, not closed
SERVICE DOOR WARNING LIGHT ILLUMINATED DURING TAKEOFF. SECURED SINGLE POINT FUEL SERVICE DOOR.
- 4 Sep 1996
Bolt, broken
NO NP OR TORQUE INDICATION AFTER ENGINE START. PROPELLER WAS NOT ROTATING. AFTER ENGINE SHUT DOWN THE PROPELLER COULD NOT BE TURNED BY HAND. WHEN ENGINE…
- 10 Jul 1996
Bracket, broken
LT MLG AFT GEAR DOOR BRACKET IS BROKEN. REPLACED BRACKET.
- 29 May 1996
Check Valve, leaking
FUEL LEAKING FROM RT ENGINE NACELLE. REPLACED THE EPA TANK CHECK VALVE.
- 2 Feb 1996
Rollers, contaminated
AFTER TAKEOFF, FLAP DISAGREEMENT WHEN FLAPS SELECTED UP. FOUND RT WING FLAP ROLLERS CONTAMINATED WITH ANTI-SEIZE COMPOUND. REPLACED ROLLERS.
- 1 Feb 1996
Rollers, worn
AFTER TAKEOFF, FLAP DISAGREEMENT WHEN FLAPS SELECTED UP. REPLACED WORN ROLLERS ON RT WING FLAPS.
- 27 Jan 1996
Sensor, defective
AFTER LANDING GEAR RETRACTED, A RUMBLING SOUND WAS HEARD AS IF GEAR DOORS WERE OPEN. FOUND LT MLG UPLOCK PROXIMITY SENSOR, SYSTEM-A DEFECTIVE. DEFERRED SYSTEM…
- 14 Jan 1996
Battery, false warning
BATTERY AURAL WARNING SOUNDED AFTER TAKEOFF. BATTERY TEMP GAUGE INDICATED NORMAL. REPLACED THE BATTERY.
- 12 Jan 1996
Flap Tracks, dirty
FLAP DISAGREEMENT WARNING WHEN FLAPS SELECTED UP AFTER TAKEOFF. CLEANED THE FLAP TRACKS AND ACFT RETURNED TO SERVICE.
- 2 Dec 1995
Accumulator, required service
DURING TAKEOFF, RECEIVED EMERGENCY PARKING BRAKE LOW PRESSURE WARNING. SERVICED THE EMERGENCY PARKING BRAKE ACCUMULATOR TO CORRECT NITROGEN CHARGE. ACFT…
- 18 Sep 1995
O-Rings, leaking
FUEL LEAKING FROM THE LEFT ENGINE NACELLE. REPLACED THE FUEL NOZZLES TRANSFER TUBE O-RINGS.
- 19 May 1995
Shutoff Valve, inop
LT COOLING PACK PRESSURE REDUCING SHUTOFF VALVE FAILED TO CLOSE WHEN PACK FAILED. REPLACED THE LT PRESSURE REDUCING SHUTOFF VALVE.
- 27 Apr 1995
Fitting, leaking
FUEL LEAKING FROM RT MLG WHEELWELL AREA. REPAIRED PERMASWAGE FITTING ON MOTIVE FLOW LINE IN RT NACELLE.