N184SK
Boeing 747-400 FAA →
registration
earlier registrations
1 past record
- 1968
service difficulty reports
25 reports
- 24 Apr 1999
Fuel Control, malfunctioned
TRIP NR 03295 LATI-EINN, NR 1 ENGINE FLAMEOUT AT 22:05 Z, ON DESCENT. ENGINE FLAMEOUT CHECKLIST COMPLETED, 35 PERCENT N2, OIL PRESSURE 20 PSI AND 25 PERCENT…
- 17 Apr 1999
P & D Valve, failed
NR 1 ENGINE FLAME-OUT AFTER ENGINE START. FUEL FLOW INDICATOR SHOWING FLUCTUATION OF 1,000 +/- 500 PSI. FUEL PRESSURE ENGINE DRIVEN PUMP. NORMAL RANGE - FUEL…
- 17 Dec 1998
Fuel Control, out of adjust
NR 4 ENGINE WOULD NOT DEVELOPE TAKEOFF POWER, (1.87 EPR). REJECTED T/O AT 100 KTS. ADJUSTED NR 4 ENGINE FUEL CONTROL IAW DMM, CH 73-20-1. PERFORMED ENGINE…
- 11 Nov 1998
O-Ring, broken
HYDRAULIC LOSS TO STANDPIPE IN FLIGHT. PERFORMED CHECKLIST, OPERATED IN MANUAL REVERSION. FOUND HYDRAULIC LEAD NR 3 ENGINE, HYDRAULIC PUMP INLET. REMOVED AND…
- 11 Nov 1998
Fitting, loose
SLOW HYDRAULIC FLUID DOWN TO STANDPIPE, MANUAL REVERSION LIGHT ON. ACCOMPLISHED ABNORMAL HYDRAULIC CHECKLIST. FOUND LOOSE FITTING PRESSURE SIDE OF NR 3 ENGINE…
- 7 Oct 1998
Engine, failed
DFW-DAY. TRIP# 02617 DISCREP: #1 ENGINE LOSS OF POWER ON CLIMBOUT 240-330. ENGINE SURGING FROM CLIMB EPR TO 1.6 THEN 1.3 SHUTDOWN, ALL PARAMETERS NORMAL.…
- 3 Oct 1998
Fitting, failed
DURING DESCENT, LOSS OF HYDRAULIC FLUID. QUANTITY DROPPED DOWN TO AUX MARK. PERFORMED IMMEDIATE ACTION ITEMS THEN ABNORMAL HYDRAULIC PROCEDURES. REPLACED NR…
- 25 Aug 1998
Cylinder, failed
AFTER PUSHBACK, AIRCRAFT WOULD ONLY TURN SEVERAL DEGREES LEFT WITH NOSE WHEEL STEERING. FOUND RT STEERING CYLINDER FAILED DURING PUSHBACK. REPLACED RT…
- 2 Jul 1998
Engine, malfunctioned
ABORTED T/O AT IAH DUE TO HIGH EGT ON ENGINE NR 2, 1.85 EPR, EGT GOES 555 REDLINE AND CONTINUE TO CLIMB, SHUT DOWN ENGINE, TAXI BACK. ENGINE NR 2 EXCEEDS MAX…
- 21 May 1998
Line, failed
DURING APPROACH, EXPERIENCED LOSS OF HYDRAULIC FLUID AND PRESSURE. COMPLIED WITH EMERGENCY CHECKLIST. FOUND AND REPLACED 2 PRESSURE HARD LINES FROM ENGINE…
- 30 Apr 1998
Cover Plate, loose
PRECAUTIONARY SHUTDOWN NR 3 ENGINE ON SHORT FINAL. OIL PRESSURE STARTED FLUCTUATING BETWEEN 45 PSI AND YELLOW ARC. SHUT IT DOWN WHEN ITWENT BELOW THE RED…
- 29 Jan 1998
Switch, failed
TRIP NR 1259, SLOT DISAGREEMENT LIGHT STAYED ON ON TAXI-OUT, RETURNED TO RAMP. ENTERED ON DMI 8052 CAT C, REMOVED AND REPLACED INBOARD RT SWITCH, OPS CHECKED…
- 21 Jan 1998
Compressor, stalled
NR 2 ENGINE COMPRESSOR STALLED ON TAKEOFF, ABORTED TAKEOFF. INSPECTED ENGINE IAW 72-00, PERFORM GROUND RUN IAW TCA MIP VOL 2, OPS CHECK NORMAL, NO STALLS NOTED.
- 5 Aug 1997
Oil Line, loose
DUE TO LOW OIL QUANTITY AND PRESSURE FLUCTUATION SHUT DOWN NR 1 ENGINE IN FLIGHT AT 15:45PER ABNORMAL CHECKLIST PAGE 3-122 (HALF GALLON AND BELOW 40 PSI). DUE…
- 11 Jul 1997
Hyd Press Trans, failed
DURING THE TAXI CHECKLIST UNABLE TO VERIFY SPOILER DROP / RISE, NO DEFLECTION ON GAUGE. REMOVED AND REPLACED SPOILER PRESSURE TRANSMITTER IAW MM 29-30-3, OPS…
- 9 May 1997
Starter, failed
NR 4 ENGINE STARTER FAILED ON STARTUP. REMOVED AND REPLACED PNEUMATIC STARTER, ENGINE OPS CHECKS OK IAW MM 80-10-1.
- 13 Mar 1997
Actuator, leaking
TNCC-KMIA, FLT 00024. DISCREP: UNSATISFACTORY UPLATCH CHECK OUT OF TNCC. ABNORMAL CH 3, P.111, CONTINUE FLIGHT NORMALLY. REMOVED AND REPLACED LT MAIN GEAR…
- 9 Feb 1997
Engine, out of trim
NR 1 ENGINE WOULD NOT GO TO TAKEOFF POWER, RETURNED TO RAMP. TRIMMED NR 1 ENGINE, SYSTEM OPS GOOD ON RUN-UP IAW MM 76-10.
- 9 Feb 1997
Engine, out of trim
NR 2 ENGINE WOULD NOT GO TO TAKEOFF POWER. RETURNED TO RAMP. TRIMMED NR 2 ENGINE, SYSTEM OPS GOOD ON RUN-UP IAW MM 76-10.
- 17 Jan 1997
Compressor, stalled
NR 4 ENGINE COMPRESSOR STALLED WITHIN 3 TO 4 SECONDS AFTER FULL TAKEOFF POWER APPLIED, 1.87 EPR / 21 DEGREES CELCIUS TEMP / ALTIMETER 30.1 AT SEA LEVEL.…
- 17 Jan 1997
Bleed Valve, failed
NR 4 ENGINE COMPRESSOR STALLED WITHIN 3 TO 4 SECONDS AFTER FULL TAKEOFF POWER APPLIED, 1.87 EPR / 26 DEGREES CELSIUS TEMP / ALTIMETER 30.01 AT SEA LEVEL.…
- 17 Jan 1997
Compressor, stalled
NR 4 ENGINE COMPRESSOR STALLED WITHIN 3 TO 4 SECONDS AFTER FULL TAKEOFF POWER APPLIED, 1.87 EPR / 22 DEGREES CELCIUS TEMP / ALTIMETER 30.17 AT SEA LEVEL.
- 15 Jan 1997
Crossfeed Valve, malfunctioned
PNEUMATIC CROSSFEED VALVE WON'T OPEN. REMOVED AND REPLACED CROSS FEED VALVE, SYSTEM OPS CHECKS GOOD IAW MM 36.
- 15 Jan 1997
Smoke Detector, malfunctioned
ON PUSHBACK, CARGO SMOKE DETECTOR LIGHT ILLUMINATED. REPAIRED NR 2 SMOKE DETECTOR, SYSTEM OPS CHECKS NORMAL IAW MM 26.
- 15 Jan 1997
Circuit Breaker, tripped
KMIA - FLT NR 01501. ON PUSHBACK, NR 4 MAIN FUEL PUMP BREAKERS (3) POPPED. CORRECTIVE ACTION: SUMPED TANK AND CLEANED BOOST AND FEED PUMP, SYSTEM CHECKS…