N18066
Cessna 150L FAA →
reservations
earlier registrations
2 past records
owner withheld at the FAA
- 1989
NTSB
- 28 Aug 1991
incident, Atlantic Ocean AO
- 26 May 1985
accident, Marshall MI
service difficulty reports
46 reports
- 30 Oct 2008
Gearbox, failed
SDQ INFLIGHT - CREW REPORTED FLAPS WOULD NOT RETRACT AFTER TAKEOFF. RETURNED TO SDQ AND LANDED WITHOUT INCIDENT. REPLACED RIGHT BEVEL GEARBOX STARBOAD SIDE.…
- 23 Oct 2008
Battery Pack, discharged
MIA - EMERGENCY LIGHT AT SEAT ROWS 1G TO 5G INOPERATIVE. CHARGED BATTERY LIGHTING SYSTEM. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 23 Oct 2008
Battery Pack, discharged
MIA - EMERGENCY LIGHTS AT RIGHT NUMBER TWO DOOR INOPERATIVE. CHARGED EMERGENCY LIGHT SYSTEM. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 10 Oct 2008
Light, inoperative
JFK - EMERGENCY LIGHT AT SEAT 13C INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 13C. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 10 Oct 2008
Light, damaged
JFK - EMERGENCY LIGHT ASSEMBLY AT SEAT 21C DAMAGED. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT SEAT 21C. SYSTEM GROUND CHECKED NORMAL OPERATIONS.
- 31 Aug 2008
Light, missing
MIA EMERGENCY LIGHT ASSEMBLY AT SEAT 31G MISSING. REPLACED EMERGENCY LIGHT ASSEMBLY AT SEAT 31G. SYSTEM GROUND CHECKED NORMAL OPS.
- 6 May 2008
Battery Pack, discharged
JFK - EMERGENCY CABIN AISLE LIGHTS AT LEFT AFT DOOR INOPERATIVE FROM COCKPIT SWITCH 29C TO 37C. REPLACED BATTERY PACK FOR EMERGENCY CABIN AISLE LIGHTS AT LEFT…
- 6 May 2008
Light, inoperative
MIA - EMERGENCY LIGHT AT LEFT NUMBER TWO DOOR INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT LEFT NUMBER TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 13 Dec 2007
Actuator, inoperative
MIA INFLIGHT T377/13DEC - NUMBER ONE YAW DAMPER PADDLE TRIPPED ON TAKEOFF. RETURNED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED AUTO PILOT YAW ACTUATOR.…
- 1 Aug 2007
Sensor, inoperative
MIA INFLIGHT T2251/01AUG MCO TO SJU - AIRCRAFT EXPERIENCED UNWANTED FUEL TRANSFER INTO THE TRIM TANK. LANDED MIA WITHOUT INCIDENT. REPLACED CENTER OF GRAVITY…
- 3 Aug 2005
Light, inoperative
JFK - EMERGENCY LIGHT AT SEATS 31G AND 34G BROKEN. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHTS AT SEATS 31G AND 34G. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 3 Aug 2005
Battery Pack, inoperative
JFK - EMERGENCY LIGHTS AT SEATS 29 TO 33C AND 35 TO 37C INOPERATIVE. REPLACED LEFT NUMBER 4 BATTERY PACK FOR EMERGENCY LIGHTS AT SEATS 29 TO 33C AND 35 TO…
- 6 Jul 2005
Battery Pack, inoperative
JFK - FOUND LEFT 4 DOOR EXIT EMERGENCY EGRESS LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT LEFT 4 DOOR FOR EMERGENCY EGRESS LIGHTS. SYSTEM GROUND CHECKED…
- 4 May 2004
Light, broken
MIA EMERGENCY LIGHT AT SEAT 9G BROKEN. INSTALLED NEW EMERGENCY LIGHT ASSEMBLY AT SEAT 9G. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)
- 31 Jan 2002
Horn, inoperative
JFK - DURING OVERNIGHT MAINTENANCE, EMERGENCY EVACUATION SIREN AT 2R DOOR WAS INOPERATIVE. REPLACED EMERGENCY EVACUATION SIREN. SYSTEM GROUND CHECKED NORMAL…
- 18 Nov 2001
Detector, malfunctioned
LHR - FLT 101 - BRAKE HOT LIGHT ILLUMINATED IN CRUISE FLIGHT. ECAM INDICATIONS ON WHEELS 1, 2, 5 AND 6 WERE 400-420 DEGREES. ACCOMPLISHED PROCEDURES IAW…
- 31 Aug 2001
Battery Pack, discharged
JFK - DURING OVERNIGHT MAINTENANCE, FIRST CLASS RIGHT SEAT MOUNTED EMERGENCY LIGHT VERY DIM. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 3 Aug 2000
Light, inoperative
JFK - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT SIGN AT 2L DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY, SYSTEM GROUND CHECK NORMAL OPERATION. (M)
- 6 May 2000
Structure, worn
TUL - FOUND RIGHT KRUEGER FLAP BLOCKER DOOR WORN 2 INCHES BY .080 DEEP IN FLANGE. REPAIRED FLAP BLOCKER DOOR PER ESO 30595 DATED 5/5/2000. (M)
- 5 May 2000
Arm, corroded
TUL - FOUND LOWER ARM ASSY CORRODED ON R1 DOOR. REMOVED AND REPLACED LOWER ARM ASSY ON R1 DOOR PER SRM 51-72-10-0. (M)
- 29 Apr 2000
Skin, corroded
TUL - FOUND A SECTION OF CORROSION 3 SQUARE INCHES AND A SECTION 20 SQUARE INCHES OUTBOARD OF RIBS 4 AND 5. (M)
- 6 Dec 1999
Oven, dirty
LHR - FLT 0106 - DURING OVERNIGHT MAINTNENANCE, FIRST CLASS NR 1 OVEN SMOKED. CLEANED FIRST CLASS OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
- 6 Dec 1999
Oven, dirty
LHR - DURING OVERNIGHT MAINTENANCE, FIRST CLASS NR 2 OVEN SMOKED. CLEANED FIRST CLASS OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
- 3 Feb 1999
Support, corroded
TUL - FOUND LAV 'L' TIE DOWN AREAS CORRODED AT INBOARD SUPPORT BEAM. REMOVED AND BLENDED OUT CORROSION PER ESO 30595/01-02-99, TREATED, PRIMED AND PAINTED. (M)
- 16 Apr 1998
Intercostal, corroded
CORROSION ON INTERCOSTAL. REMOVED AND REPLACED INTERCOSTAL PER SRM 51-72-10. TST: 25,900 HOURS. CYCLES: 10,200. (X)
- 9 Apr 1998
Stringer, corroded
TUL - CORROSION ON STR 53L. REPLACED STRINGER SECTION PER SRM 53-10-14-2. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 9 Apr 1998
Stringer, corroded
TUL - CORROSION ON STR 48L SPLICE. REPLACED STRINGER SPLICE PER SRM 51-72-10-0. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 8 Apr 1998
Fitting, cracked
TUL - CONNECTING FITTING LEFT SIDE BETWEEN FR 13A AND FR 14A CRACKED AT UPPER OUTBOARD EDGE OF REGION B. BLENDED CRACK AT UPPER OUTBOARD EDGE OF REGION 'B' OF…
- 8 Apr 1998
Stringer Splice, corroded
TUL - STRINGER SPLICE AT FRAME 65 TO LEFT IS CORRODED. REMOVED AND REPLACED PER SRM 51-72-10-0. TST: 25,942.58 HOURS. CYCLES: 10,261. (X)
- 8 Apr 1998
Stringer Splice, corroded
TUL - STRINGER SPLICE AT FRAME 65 STRINGER 49L CORRODED. REMOVED AND REPLACED PER SRM 51-72-10-0. TST: 25,942.58 HOURS. CYCLES: 10,261. (X)
- 8 Apr 1998
Support, corroded
TUL - FLOORBOARD SUPPORT FRAME HAS CORROSION FORWARD SIDE BETWEEN NR 4 AND NR 6 ROLLER TRAYS. SPLICED IN NEW SECTION OF CROSSBEAM 12 INCHES RIGHT OF…
- 7 Apr 1998
Stringer, corroded
TUL - CORROSION ON STRINGER 51L. REPLACED STRINGER SECTION PER SRM 53-10-14-2. TST: 25,942 HOURS. CYCLE: 10,261. (X)
- 7 Apr 1998
Stringer, corroded
TUL - CORROSION ON STRINGER 49L. INSTALLED NEW STRINGER SECTION PER SRM 53-10-14-2. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 7 Apr 1998
Longeron, corroded
TUL - CORROSION ON RT SIDE OF LONGERON 56 RT BETWEEN FRAMES 57.2 AND 57.3. BLENDED OUT CORROSION PER SRM 51-74-14-2 AND INSTALLED DOUBLER PER SRM 53-10-14-2.…
- 6 Apr 1998
Fitting, corroded
TUL - CROSSBEAM END FITTING CORRODED ON FORWARD FLANGE AT TRAY NR 6. INSTALLED DOUBLER REF SRM 53-10-15-2. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 6 Apr 1998
Stringer, corroded
TUL - STRINGER SPLICE CORRODED AT 48L FRAME 65. REMOVED AND REPLACED STRINGER SPLICE PER SRM 51-72-10-0. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 6 Apr 1998
Floor Support, corroded
TUL - CORROSION ON FLOOR SUPPORT INBOARD OF COCKPIT DOOR AT FRAME 12. INSTALLED NEW EXTRUSION, ALODINED, PRIMED AND PAINTED PER SRM 53-12-15-0. TST: 25,942.58…
- 2 Apr 1998
Shear Tie, corroded
TUL - CORROSION ON SHEAR TIE BETWEEN STR 54L AND STR 55L. REPLACED SHEAR TIE PER SRM 51-72-10. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 31 Mar 1998
Stringer, corroded
TUL - CORROSION ON STR 55L. REPLACED STRINGER SECTION PER SRM 53-10-14. TST: 25,942 HOURS. CYCLES: 10,261. (X)
- 14 Feb 1998
Connector, loose
JFK - DURING OVERNIGHT CHECK, AFT LAVATORY SMOKE DETECTOR RED WARNING LIGHT INOPERATIVE. RESECURED LOOSE CONNECTOR FOR AFT LAVATORY SMOKE DETECTOR RED WARNING…
- 21 Sep 1997
Converter, defective
JFK - 1473 - AFTER TAKEOFF JFK, NR 2 TAT FAULT AND FAINT ELECTRICAL ODOR NOTED WITH DC ELECTRIC T/R'S XXX OUT. AIRCRAFT RETURNED TO JFK AND LANDED WITHOUT…
- 23 Dec 1996
Strip, broken
BDL - DURING OVERNIGHT CHECK, FUOND EMERGENCY EXIT FLOOR PATH LIGHTING AT ROW 21 A/B BROKEN. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT ROW 21 A/B.…
- 27 Oct 1996
Light, missing
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 21B AND 24B INOPERATIVE. REPLACED MISSING EMERGENCY FLOOR LIGHT STRIP BETWEEN PAX…
- 18 Aug 1996
Connector, loose
JFK - DURING OVERNIGHT MAINTENANCE, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS AT ROWS 8H AND 12H INOPERATIVE. SECURED CONNECTOR. SYSTEM GROUND CHECKED NORMAL…
- 28 Jun 1995
Sensor, defective
SJU - FLT 1786 - AFTER TAKEOFF ANU, LANDING GEAR WOULD NOT RETRACT IN SYSTEM 2. SELECTED SYSTEM 1 AND LANDING GEAR RETRACTED NORMALLY. AIRCRAFT PROCEEDED SJU…
- 30 May 1995
Eel Strip, defective
JFK - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS IN FRONT OF THE L3 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP FROM SIDE…