~/tools/licenses/N176AM
N176AM
2007 Sikorsky S-76C standard FAA →
registration
- 2007
service difficulty reports
4 reports
- 29 Nov 2013
Starter Gen, failed
NR 1 STARTER/GENERATOR FAILED. DURING START, THE ENGINE TOOK AN UNUSUALLY LONG TIME TO REACH LIGHT OFF AND IDLE SPEED. AFTER ENGINE START, THE GENERATOR WOULD…
- 25 Jun 2013
Brushes, broken
NR 2 DC GENERATOR FAILED IN FLIGHT. AFTER THE ACFT RETURNED TO THE MX FACILITY, THE STARTER GENERATOR WAS REMOVED FOR INSPECTION. THE BRUSHES WERE FOUND WORN…
- 29 Nov 2012
Hmu, malfunctioned
THE FUEL CONTROL FAILED ON START CAUSING THE ENGINE TO EXCEED TEMPERATURE LIMITS. THE HMU WAS FOUND TO BE AT FAULT. (SUSPECT THE CONSTANT DELTA "P" VALVE…
- 8 Aug 2012
Engine, vibration
INTEGRATED INFORMATION DISPLAY SYSTEM, (IIDS), DISPLAYED A "MINOR" ENGINE FAULT "TQ TRIM LVL L" FOR THE NR 1 ENGINE FROM THE DIGITAL ENGINE CONTROL UNIT…