N17317
2023 Boeing 737-8 standard FAA →
registration
- 2023
earlier registrations
3 past records
- 2007
- 1985
- 1937
NTSB
- 17 Mar 1990
incident, Wichita KS
service difficulty reports
23 reports
- 4 Mar 2026
Motor, clogged
AFT LAV 2R CLOGGED MOTOR WILL NOT FLUSH AND IS BACKING UP CLEANED EXCESIVE AMOUNTS OF COMPACTED PAPER TOWELS FROM AFT RT TOILET AND FWD TOILET. AS A…
- 1 Mar 2026
Toilet, clogged
FWD TOILET INOPERATIVE, PAPER TOWELS FLUSHED, AIR FLOW WAS CONT BUT F LSD NOW NO SOUND CLEANED EXCESIVE AMOUNTS OF COMPACTED PAPER TOWELS FROM AFT RT TOILET…
- 19 Sep 2025
Motor, faulted
ELECTRIC AND MANUAL TRIM WILL NOT MOVE REMOVED COMBINED STABILIZER TRIM MOTOR (M1659) REF: AMM 27-41-71-000-801. INSTALLED COMBINED STABILIZER TRIM MOTOR…
- 25 Aug 2025
Not Reported, no discrepancy
PREVIOUS FLIGHT PAX REPORT WATER LEAKING FROM EXIT ROW DOOR. INSPECTED AND DID NOT FIND ANY FLUID COMING FROM ANYWHERE IN THE ARE OF ANY OF THE EXIT ROW…
- 1 Oct 2023
Sensor, no test
COCKPIT TEMP RUNAWAY. NOTICED RISING TEMP AFTER ENGINE START. C OCKPIT REACHED 78C PACK FLOW CTRL SENSOR L STATUS MESSAGE PRESENT. MAINT. MESS 21-55060.…
- 13 Apr 2003
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 1016, LBL 27. THE UPPER T-CAP ON FLOORBEAM WAS REPLACED IAW ECRA 5310-03851.
- 6 Apr 2003
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED THROUGH FASTENERS AND SHIM AT STA 986.5, RBL 48. THE CORRODED SECTION WAS REMOVED AND A REPAIR WAS INSTALLED IAW ECRA…
- 17 Jan 2002
Skin, dented
INSPECTION FOUND FORWARD CARGO DOOR OUTER SKIN DENTED IN CENTER OF DOOR. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-00-01.
- 14 Jan 2002
Skin, worn
INSPECTION FOUND FUSELAGE SKIN WORN BELOW R/H HORIZONTAL STABILIZER AFT ATTACH LUG AT STA 1156. THE WORN SKIN WAS REMOVED AND NEW SKIN WAS INSTALLED IAW SRM…
- 13 Jan 2002
Cargo Track, corroded
INSPECTION FOUND AFT BAGGAGE BIN RT TIE DOWN RAIL CORRODED AT STA 787-847. THE RT TIE DOWN RAIL WAS REMOVED AND REPLACED IAW SRM 51-10-02 AND 53-00-53, FIGURE…
- 13 Jan 2002
Cargo Track, corroded
INSPECTION FOUND AFT BAGGAGE BIN FLOOR RAIL CORRODED AT STA 770, RBL 8. THE FLOOR RAIL WAS REPAIRED IAW ECRA 5320-01603.
- 13 Jan 2002
Cargo Track, corroded
INSPECTION FOUND AFT BAGGAGE BIN FLOOR RAIL CORRODED AT STA 770, LBL 3 TO LBL 12. THE FLOOR RAIL WAS REPAIRED IAW ECRA 5320-01603.
- 12 Jan 2002
Channel, corroded
INSPECTION FOUND AFT BAGGAGE BIN FLOOR CHANNEL CORRODED AT STA 860, RBL 3. THE CORRODED AREA WAS REMOVED AND AN ANGLE REPAIR WAS INSTALLED IAW ECRA 5320-01603.
- 21 Jan 2001
Control Cable, broken
THE LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF FROM DCA. CHECKLIST PROCEDURES WERE COMPLIED WITH AND THE AIRCRAFT WAS RETURNED TO DCA WHERE IT LANDED…
- 4 Oct 2000
Fire Detector, false indication
ON DESCENT INTO RDU DSCH LIGHT CAME ON FOR THE NUMBER ONE BOTTLE FOR THE CARGO DETECTION SUPPRESION SYSTEM. LATER ON FIRE WARNING LIGHT CAME ON. REPLACED FIRE…
- 7 Jul 1999
Skin, cracked
INSPECTION FOUND A .375 INCH CRACK IN OUTBOARD CORNER OF CAPTAIN'S FORWARD WINDOW FRAME. VA DOUBLER WAS INSTALLED IAW ECRA 5330-02841.
- 29 Jun 1999
Floorbeam, corroded
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 346 FROM RBL 15 TO LEFT SIDEWALL. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A NEW SECTION OF FLOORBEAM…
- 28 Jun 1999
Floorbeam, corroded
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 294, LBL 25 TO RBL 15. A NEW FLOORBEAM AND DOUBLERS WERE INSTALLED IAW SRM 53-10-51.
- 28 Jun 1999
Seat Track, corroded
INSPECTION FOUND LEFT O/B SEAT TRACK CORRODED AT STA 340-380. THE CORRODED SEAT TRACK SECTION WAS REMOVED AND REPLACED IAW SRM 53-00-52, FIGURE 202.
- 18 Jun 1999
Battery Pack, discharged
INSPECTION FOUND EMERGENCY LIGHTS AT SEVEN SEATS IN COACH SECTION OF CABIN INOPERATIVE. THE OVERHEAD BATTERY PACK WAS REMOVED AND REPLACED AND OPERATION OF…
- 26 Jun 1998
Light, rusted
THE EMERGENCY SLIDE LIGHT AT L-2 DOOR DID NOT COME ON WHEN TESTING EMERGENCY LIGHTS FROM EITHER SWITCH. THE LIGHT ASSEMBLY WAS REPLACED DUE TO INTERNAL…
- 4 Sep 1997
Sensor, inoperative
THE LT MLG UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION LEAVING EWR. THIS WAS A REPEAT PROBLEM. CYCLING THE GEAR DID NOT HELP. THE GEAR WAS…
- 12 Aug 1996
Light, inoperative
INSPECTION FOUND THE R-1 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. THE LIGHT SOCKET WAS FOUND CORRODED. THE R-1 DOOR EXTERIOR EMERGENCY LIGHT WAS REMOVED AND…