N17309
2023 Boeing 737-8 standard FAA →
registration
- 2023
earlier registrations
1 past record
NTSB
- 20 Feb 1986
accident, Denver CO
service difficulty reports
49 reports
- 15 Aug 2025
Unknown, odor
BAD ODOR COMING FROM AC SYSTEM. FOUND APU RUNNING AND EXTERNAL AIR HOOKED UP ON ARRIVAL. DISCONNECTED EXT AIR AND RAN BOTH PACKS. WALKED CABIN AND FLIGHT DK…
- 26 May 2025
Warning Message, false indication
ANTI-ICE MASTER CAUTION DURING TAKEOFF ROLL DEBRIEFED CREW. ON TAKEOFF ROLL AT 80 KT RECEIVED ANTI ICE MASTER CAUTION MOMENTARILY. NOTED NO FAULTS ON MASTER…
- 27 Apr 2025
Door, none
BATHROOM DOOR 2R JAMMED. FOUND LAV E OPENING AND CLOSING NORMAL. ALSO CHECKED LAV D AND A DOORS. ALL OPERATING NORMAL. FOUND LAV E OPENING AND CLOSING NORMAL.…
- 14 Mar 2025
None, none
PRESS GAUGE ON 2L/2R ARE BORDERLINE INSPECTED DOOR SLIDE PRESSURES. BOTH ARE WITHIN LIMITS REF. AMM 25-66-01.
- 12 Jul 2024
Windshield, cracked
POSSIBLE CRACK ON R1 LOWER SIDE REMOVED R2 WINDSHIELD IAW AMM 56-11-11. AND INSTALLED R2 WINDSHIELD UP TO STEPS 8-B IAW AMM 56-11-11. STEPS 9 THRU CLOSE UP…
- 23 Feb 2005
Channel, cracked
INSPECTION FOUND A 10 INCH CRACK IN STIFFENER CHANNEL IN FORWARD CARGO BAY AT VOR ANTENNA, STA 500 BETWEEN S28L AND S28R. THE CHANNEL WAS REMOVED AND REPLACED…
- 22 Feb 2005
Shear Tie, corroded
INSPECTION FOUND SKIN CLIP CORRODED AT STA 500, RBL 2 IN FORWARD BAGGAGE BIN FLOOR AREA. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-00-07 FIGURE 207.
- 20 Feb 2005
Frame, corroded
INSPECTION FOUND STA 500 FRAME CORRODED AT SKIN ATTACH POINT BETWEEN S27R AND S28R, RBL 11-RBL 16. A FRAME REPAIR WAS INSTALLED IAW SRM 53-00-07, FIGURE 203.
- 20 Feb 2005
Stringer, corroded
INSPECTION FOUND STRINGER 27L CORRODED AT RIVET HOLES BETWEEN STA 500 AND 500B. THE CORRODED SECTION OF STRINGER WAS CUT OUT AND A REPAIR WAS INSTALLED IAW…
- 29 Sep 2003
Wire, broken
INSPECTION FOUND EMERGENCY AISLE LIGHTS AT ROW S 12-20 INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE AT STA 378 EMERGENCY LIGHT BATTERY PACK. THE BROKEN WIRE…
- 26 Sep 2003
Battery Pack, inoperative
THE INTERIOR EMERGENCY AISLE LIGHTS AT ROWS 14R, 16L, 19L, 21R, AND 23L WERE FOUND INOPERATIVE. REPLACED BATTERY PACKS AT M1135 AND M1136 POWER SUPPLIES IAW…
- 8 Jul 2003
Pressure Panel, cracked
INSPECTION FOUND A 3 INCH CRACK IN PRESSURE DECK AT STA 665, RBL 35, JUST O/B OF J-BOX IN RT WHEEL WELL CEILING. THE PRESSURE DECK WAS REPAIRED IAW SRM…
- 25 Jun 2003
Uplock, inoperative
THE RT MLG FAILED TO EXTEND ON FIRST ATTEMPT WHILE ON APPROACH TO IAH. THE FAILURE WAS ACCOMPANIED BY ILLUMINATION OF THE RT MLG RED WARNING LIGHT. A TOWER…
- 28 Feb 2003
Beam, corroded
INSPECTION FOUND ALL TORQUE BOX MOUNTING HOLES ELONGATED ON L-2 DOOR. REPAIRED IAW ECRA 5210-01658.
- 26 Feb 2003
Skin, cracked
INSPECTION FOUND A 1/2" CRACK IN L-2 DOOR AT WEB OPENING ON INTERIOR SKIN ABOVE INSTALLED TORQUE TUBE. INSTALLED REPAIR IAW ECRA 5210-01653.
- 23 Feb 2003
Web, corroded
INSPECTION FOUND VERTICAL WEB CORRODED IN AFT BAGGAGE BIN AT STA 791-800, RBL 20. A NEW WEB WAS INSTALLED IAW SRM 51-70-11.
- 23 Feb 2003
Strap, corroded
INSPECTION FOUND CORROSION ON AFT LOWER STRAP ON BOTTOM SIDE OF VERTICAL WEB UPPER FLANGE AT STA 840-853, RBL 19. THE STRAP WAS REMOVED AND REPLACED IAW SRM…
- 23 Feb 2003
Strap, corroded
INSPECTION FOUND STRAP CORRODED UDER VERTICAL WEB AT STA 780-800, RBL 20. THE STRAP WAS REMOVED AND REPLACED IAW SRM 51-10-2.
- 23 Feb 2003
Web, corroded
INSPECTION FOUND THE FORWARD I/B CORNER OF WEB CORRODED AT AFT CARGO DOOR LOWER THRESHOLD. THE THRESHOLD WEB WAS REMOVED AND REPLACED IAW SRM 51-10-2 AND…
- 23 Feb 2003
Strap, corroded
INSPECTION FOUND R/H FLOOR SUPPORT STRAP CORRODED AT STA 793. THE FLOOR SUPPORT STRAP WAS REMOVED AND REPLACED IAW SRM 51-10-2.
- 22 Feb 2003
Frame, corroded
INSPECTION FOUND BELTFRAME CORRODED AT STA 793. THE CORRODED AREA WAS REMOVED AND A TYPICAL FORMED SECTION REPAIR WAS INSTALLED IAW SRM 51-70-11.
- 19 Feb 2003
Seat Track, corroded
INSPECTION FOUND L/H O/B SEAT TRACK AT BS 907-947.5 CORRODED. THE CORRODED SECTION OF SEAT TRACK WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW SRM 53-00-52,…
- 17 Feb 2003
Stringer, corroded
INSPECTION FOUND STRINGER 28R AND 29L CORRODED AT STA 323 AT FORWARD SIDE OF E&E DOOR JAMB. THE STRINGER SECTIONS WERE REMOVED AND REPLACED IAW SRM 51-10-2.
- 16 Feb 2003
Strap, corroded
INSPECTION FOUND H-STRAP CORRODED AT STA 1006, BL 0. THE H-STRAP WAS REMOVED AND A NEW STRAP WAS INSTALLED IAW SRM 51-40-02.
- 16 Feb 2003
Pan, corroded
INSPECTION FOUND LAV FLOOR PAN FASTENER CORRODED AT STA 1016, RBL 13. A NEW FLOOR PAN WAS INSTALLED IAW SRM 51-20-02.
- 15 Feb 2003
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 986, BL 0 TO LBL 18. THE UPPER CHORD OF FLOORBEAM WAS REMOVED AND REPLACED IAW ECRA 5310-03851, REV. B.
- 14 Feb 2003
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM UPPER CHORD CORRODED AT STA 344 BETWEEN LBL 36 AND RBL 12. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED AND REPLACED IAW SRM…
- 10 Feb 2003
Skin, gouged
INSPECTION FOUND THE R/H UPPER FUSELAGE SKIN GOUGED BELOW FORWARD R/H SIDE DORSAL FIN MOUNT POINT AT STA 880, STRINGER 2R. A DOUBLER REPAIR WAS INSTALLED IAW…
- 10 Feb 2003
Stiffener, corroded
INSPECTION FOUND STIFFENER CORRODED AT LEFT SIDE AND RIGHT SIDE OF BL0 BELOW FLOOR LINE AT STA 1016. REPAIRED IAW EA 5310-04045, POS 2.
- 10 Feb 2003
Galley Track, corroded
INSPECTION FOUND GALLEY FLOOR TRACK CORRODED BETWEEN BS 277 - 294 AT RBL 36. THE TRACK WAS REMOVED AND REPLACED IAW SRM 51-10-02.
- 1 Jan 2003
Skin, cracked
INSPECTION FOUND A 1.5" CRACK IN R/H FUSELAGE SKIN AFT OF TRAILING EDGE OF FLAP, BS 727E, S18R. A DOUBLER WAS INSTALLED IAW SRM 53-00-01 AND ECRA 5330-03191.
- 4 Dec 2001
Skin, cracked
INSPECTION FOUND A 1/4" CRACK AT LOWER HINGE OF R-1 DOOR EXTERIOR SKIN. A REPAIR WAS INSTALLED IAW ECRA 5210-01458.
- 30 Nov 2001
Seat Track, corroded
INSPECTION FOUND CABIN L/H O/B SEAT TRACK CORRODED AT STA 887-907. REPAIRED SEAT TRACK IAW SRM 53-00-52, FIGURE 204.
- 28 Nov 2001
Frame, corroded
INSPECTION FOUND FRAME CORRODED AT STA 1006 BETWEEN S16R AND S15R. A FRAME REPAIR SECTION AND SPLICES WERE INSTALLED IAW SRM 53-00-07, FIGURE 201.
- 27 Nov 2001
Skin, cracked
INSPECTION FOUND A 1/2" CRACK IN #1 PYLON SKIN PANEL #5727L. REPAIRED IAW ECRA 5430-01230.
- 23 Nov 2001
Bracket, cracked
INSPECTION FOUND A 1/4" CRACK IN R/H WING #6 FLAP TRACK FAIRING I/B SUPPORT BRACKET. A NEW BRACKET WAS INSTALLED IAW MM 51-10-02.
- 18 Sep 1999
Skin, cracked
INSPECTION FOUND A 2 INCH CRACK IN FORWARD LOWER FUSELAGE SKIN AT BS 373 AT GROUND BLOWER EXHAUST. THE CRACK WAS STOP DRILLED AND A REPAIR DOUBLER WAS…
- 7 May 1999
Stringer, corroded
STRINGER 26L IS CORRODED FROM STA 500 TO 500D ALONG WITH STRINGER ATTACH CLIP AT STA 500D FORWARD CARGO PIT. SPLICED IN NEW SECTION OF STRINGER PER SRM…
- 3 May 1999
Skin, cracked
FUSELAGE SKIN CRACKED UPPER LEFT CORNER OF CAPTAINS WINDSHIELD 1/2 TO RIVET. CONFIRMED WITH HFEC. REPAIRED PER EC/RA 5330-02802.
- 30 Apr 1999
Floorbeam, cracked
HOU - FLOORBEAM WEB CRACKED .35 INCH AT STATION 328 LBL 1. INSTALLED REPAIR PER EC/RA 5310-03847. (M)
- 26 Apr 1999
Seat Track, corroded
CABIN RIGHT O/B SEEAT TRACK HEAVY CORROSION AT STA 907 - 917. REMOVED CABIN SEAT TRACK AT STA 907 TO END OF TRACK PER SRM 53-00-52.
- 23 Apr 1999
Seat Track, corroded
CABIN RIGHT SIDE INBOARD SEAT TRACK HEAVY CORROSION BS 907 - BS 930. SPLICED IN NEW SEAT TRACK SECTION AT STA 827 - 947 PER SRM 5300-00-52 FIG 204.
- 19 Apr 1999
Floorbeam, corroded
INSPECTION FOUND CABIN FLOORBEAM UPPER CHORD CORRODED AT STA 344, BL 0 TO LBL 15. THE FLOORBEAM UPPER CHORD WAS REMOVED AND REPLACED IAW SRM 53-10-51, FIGURE…
- 21 Dec 1998
Switch, inoperative
THE NOSE GEAR RED UNSAFE LIGHT REMAINED ILLUMINATED WHEN GEAR WAS EXTENDED FOR LANDING AT PBI. THE GEAR WAS CYCLED, BUT THE RED LIGHT DID NOT EXTINGUISH. A…
- 16 Oct 1998
Power Supply, inoperative
AFT 4 SEATS AND AFT 3 LOWER EMERGENCY EXIT LIGHTS INOP. REMOVED AND REPLACED BATTERY POWER SUPPLY IN AFT CEILING, STA 920 PER MM 33-51-51.
- 11 Mar 1997
Hyd Line, leaking
THE HYDRAULIC B NR 1 ELECTRIC LOW PRESSURE LIGHT CAME ON FOLLOWED BY NR 2 ENGINE LOW PRESSURE AND HYDRAULIC B QUANTITY DROPPED TO ZERO. THE A/C WAS RETURNED…
- 2 Sep 1996
Hyd Line, broken
THE B-SYSTEM LOW PRESSURE LIGHT FOR NR 2 ENGINE HYDRAULIC PUMP ILLUMINATED FOLLOWED BY B-SYSTEM HYDRAULIC QUANTITY DROP TO 0.5 GALLONS WHILE APPROACHING CLE.…
- 19 May 1995
Hyd Line, leaking
FLT NR 0419 - CLE - THE 'A' SYSTEM HYDRAULIC QUANTITY WAS LOST WHILE IN FLIGHT. THE FLUID LOSS WAS ACCOMPANIED BY ILLUMINATION OF THE NR 1 ENGINE DRIVEN…
- 17 Jan 1995
Circuit Breaker, failed
CLE - FLT 1835 - THE ACFT EXPERIENCED AN ELECTRICAL FAILURE WHILE EN ROUTE TO MDW. THE APU WAS STARTED, BUT IT WOULD ONLY POWER THE LT SIDE. THE TRANSFER BUS…