service difficulty reports
26 reports
- 8 Jul 1998
Accessory Unit, inoperative
THE GEAR HANDLE STOPPED IN THE OFF POSITION WHEN RAISING THE GEAR AFTER TAKEOFF. THE GEAR TRIGGER WAS PULLED AND THE GEAR CAME UP. MAINTENANCE REMOVED AND…
- 11 Dec 1996
Skin, corroded
INSPECTION FOUND NLG WHEEL WELL UPPER SKIN CORRODED AFT OF ACCESS, STA 240. THE SKIN WAS REPAIRED IAW ECRA 5310-03378.
- 11 Dec 1996
Stringer, corroded
INSPECTION FOUND FUSELAGE STRINGER 24L CORRODED FROM FS 970 TO 1000. THE CORRODED SECTION OF STRINGER WAS REMOVED IAW SRM 51-10-6. STRINGER REPAIR PARTS WERE…
- 11 Dec 1996
Skin, corroded
INSPECTION FOUND EXTERNAL FUSELAGE SKIN LAP BULGED AND ONE FASTENER SHEARED AT FS 380, STRINGER 26R. THE CORROSION WAS REMOVED IAW SRM 51-10-6. FILLER AND…
- 11 Dec 1996
Skin, cracked
INSPECTION FOUND A 2 INCH CRACK IN FUSELAGE SKIN AT BS 755, STRINGER 19R. THE CRACKED AREA WAS REMOVED IAW SRM 53-30-3. A DOUBLER WAS FABRICATED AND INSTALLED…
- 11 Dec 1996
Floorbeam, corroded
INSPECTION FOUND CABIN FLOORBEAM CORRODED ON UPPER CHORD AT STA 294.5 FROM RBL 20 TO LBL 20. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED, A NEW FLOORBEAM…
- 11 Dec 1996
Skin, cracked
INSPECTION FOUND .5 INCH CRACKS IN LT FUSELAGE SKIN AT BS 188 TO 251, WL 207 TO 234. THE AREA WAS REPAIRED IAW SRM 51-30-2, BAC DRAWING NR 65-18420, AND EA…
- 11 Dec 1996
Window Frame, corroded
INSPECTION FOUND FORWARD LOWER CORNER OF NR 4 RT CABIN WINDOW FRAME CORRODED. THE WINDOW FRAME WAS REMOVED AND A NEW FRAME WAS FABRICATED AND INSTALLED IAW…
- 9 Dec 1996
Stringer, cracked
INSPECTION FOUND A 1 INCH CRACK AT STRINGER 7R FASTENER ON RT WING UPPER SURFACE, WBL 200. A REPAIR STRAP WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND…
- 9 Dec 1996
Skin, corroded
INSPECTION FOUND NOSE WHEEL WELL CUTOUT AFT RT CORNER HAD CORRODED SKIN AND STRESSED FASTENERS. LOWER LOBE SKINS WERE CUT AND REMOVED FROM STA 253 TO 312. THE…
- 9 Dec 1996
Bear Strap, corroded
INSPECTION FOUND E AND E DOOR CUTOUT BEAR STRAP CORRODED AT FORWARD SIDE OF CUTOUT. STRINGER 29 WAS REMOVED AND CORROSION WAS REMOVED FROM SKIN AND BEAR STRAP…
- 7 Dec 1996
Intercostal, cracked
INSPECTION FOUND A 1.5 INCH CRACK IN INTERCOSTAL AT STA 357, STRINGER 16L. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-30-2.
- 7 Dec 1996
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM UPPER T-CAP CORRODED AT STA 328, RBL 10 TO RBL 46. THE UPPER T-CAP WAS REMOVED, A NEW UPPER T-CAP WAS FABRICATED AND INSTALLED IAW…
- 7 Dec 1996
Skin, corroded
INSPECTION FOUND FUSELAGE EXTERIOR SKIN LAP CORRODED AT STA 540, STRINGER 26L. REPAIR FILLER AND DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 51-30-2.
- 6 Dec 1996
Web, corroded
INSPECTION FOUND AFT LAV LT PAN CORRODED AROUND DUMP CHUTE AND CENTER SUBSTRUCTURE CHANNEL CORRODED AT UPPER SURFACE. THE FLOOR WEB AND CENTER CHANNEL WERE…
- 4 Dec 1996
Stiffener, corroded
INSPECTION FOUND STA 285.62 NOSE WHEEL WELL RT VERTICAL STIFFENER CORRODED 3 INCHES FROM LOWER END AND 2 INCHES FROM UPPER END. THE VERTICAL STIFFENER WAS…
- 25 Nov 1996
Skin, corroded
INSPECTION FOUND FUSELAGE SKIN CORRODED BETWEEN RIVETS AT BS 964, STRINGER 20L. THE CORRODED AREA OF SKIN WAS CUT OUT, DOUBLERS AND FILLERS WERE FABRICATED…
- 16 Nov 1996
Skin, cracked
INSPECTION FOUND A 1.75 INCH CRACK IN FUSELAGE SKIN AT BS 775, STRINGER 19R. THE CRACKED AREA WAS CUT OUT, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW…
- 25 Apr 1996
Skin, cracked
GSO - REMOVED DAMAGE AREA AND FABRICATED DOUBLER, INSTALLED DOUBLER AT STRINGER 20R - STATION 192 PER SRM 53-30-3. (M)
- 21 Apr 1996
Switch, inoperative
FLT NR 234 - EWR - RIGHT MAIN LANDING GEAR RED UNSAFE LIGHT ILLUMINATED, AFTER GEAR LOWERED DURING APPROACH FOR LANDING. CYCLED GEAR, RED AND GREEN LIGHT…
- 13 Dec 1995
Battery Pack, discharged
GSO - INSPECTION FOUND BOTH RT WING EXTERIOR EMERGENCY LIGHTS INOPERATIVE. THE BATTERY PACK WAS REPLACED AND OPERATION OF THE LIGHTS WAS RESTORED. (M)
- 13 Dec 1995
Light, inoperative
GSO - INSPECTION FOUND THE L-1 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. THE L-1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY WAS REMOVED AND REPLACED. (M)
- 13 Dec 1995
Battery Pack, discharged
GSO - INSPECTION FOUND THE OVERHEAD EMERGENCY EXIT LIGHT AT ROW 23 INOPERATIVE. THE EMERGENCY EXIT LIGHT BATTERY PACK WAS REMOVED AND REPLACED. (M)
- 13 Dec 1995
Light, inoperative
GSO - INSPECTION FOUND THE LEFT OVERWING INTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. THE EMERGENCY EXIT LIGHT ASSEMBLY WAS REMOVED, RECHARGED, AND INSTALLED. (M)
- 13 Dec 1995
Skin, corroded
GSO - INSPECTION FOUND THE FUSELAGE SKIN AND DOUBLERS CORRODED AT AFT LOWER CORNER OF C-1 DOORWAY. THE CORROSION WAS REMOVED. REPAIR DOUBLERS WERE FABRICATED…
- 27 Dec 1994
Spar Skin, corroded
GSO - INSPECTION FOUND THE LT WING LOWER FRONT SPAR CHORD SKIN CORRODING WITH FASTENER PULLING THROUGH THE SKIN AT WBL STA 157. A SKIN REPAIR WA INSTALLED IAW…