N151SY
2015 Embraer S A ERJ 170-200 LR standard FAA →
registration
- 2015
earlier registrations
1 past record
- 1982
NTSB
- 23 Dec 1996
accident, Las Vegas NV
service difficulty reports
167 reports
- 31 Aug 2026
Seat Track, corroded
FWD WET AREA RT SEAT TRACK WAS CORRODED ON THE CROWN, BTWN FR 18-19, Y105. R & R THE SEAT TRACK IAW SRM 51-40-08.
- 31 Aug 2026
Floorbeam, corroded
FWD WET AREA FLOORBEAM WAS CORRODED, FR 17, Y-10. REPAIRED FLOORBEAM IAW SRM 53-00-10,REPAIR 3P. NO FURTHER ACTION REQUIRED
- 31 Aug 2026
Beam, corroded
AFT WET AREA LH UPPER BEAM HAD CORROSION BTWN FR 87-88, Y-10 - Y-12. REMOVED AND REPLACED AFT WET AREA LH UPPER BEAM IAW SRM 51-40-08.
- 31 Aug 2026
Floorbeam, corroded
FWD WET AREA HAS CORROSION ON LONGITUDINAL FLOORBEAM AT FR 17, Y-10. REMOVED AND REPLACED THE FLOORBEAM AT FR 17 AND Y-10 IAW SRM 51-40-08.
- 31 Aug 2026
Seat Track, corroded
FWD WET AREA CENTER SEAT TRACK HAS CORROSION ON CROWN AT FR 20-21 AND Y-10. REPAIRED TRIMMED OUT FWD WET AREA CENTER SEAT TRACK CROWN TEETH AT FR 20-21 AND…
- 26 Nov 2023
Unknown, warning message
ENG 2 FIRE DET FAIL CAUTION MSG WHILE CLIMBING OUT OF BNA ABOVE 13,000. MSG GOT CLEARED ON ITS OWN; FOLLOWED QRH - NO INDICATION OF FIRE FOUND ON ENG 2…
- 26 Nov 2023
Unknown, warning message
ENG 2 FIRE DET FAIL CAUTION MSG WHILE CLIMBING OUT OF BNA ABOVE 13,000. MSG GOT CLEARED ON ITS OWN; FOLLOWED QRH - NO INDICATION OF FIRE FOUND ON ENG 2…
- 22 Jun 2023
Unknown, corroded
LH FLOOR SEAT TRACK FLANGE HAS CORROSION AT FR 19-20 AT BASE OF CROWN TEETH TRANSITION. (C-CHECK RO 7/13/2023) L/H INBD SEAT TRACK WAS REMOVED AND REPLACED…
- 21 Jun 2023
Unknown, gouged
LH O/B SEAT TRACK FR74/84 GOUGED IN THREE LOCATIONS AS MARKED (C-CHECK RO 7/13/2023) REMOVED AND REPLACED LH O/B SEAT TRACK FR74/84 REF SRM 51-40-08. LH O/B…
- 21 Jun 2023
Unknown, corroded
CORROSION - RH I/B SEAT TRACK BETWEEN FR83/84 (C-CHECK RO 7/13/2023) REMOVED CORROSION FROM RH IB SEAT TRACK BY CUTTING OUT DAMAGE AND SPLICING IN ANEW…
- 13 Sep 2020
Rib, cracked
PANEL 345 AR INNER RIB CRACKED, AS MARKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED CRACKED RIB ON PANEL 345AR, REF EMB SRM.
- 13 Sep 2020
Support Rod, cracked
FUELING PANEL SUPPORT ROD IS CRACKED AND GOUGED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED FUEL PANEL SUPPORT ROD, REF E175 AMM.
- 12 Sep 2020
Guide, cracked
LT WING NR 4 AFT FLAP CARRIAGE INBOARD FWD TRACK GUIDE CRACKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED LT NR 4 AFT FLAP CARRIAGE INBOARD FWD TRACK GUIDE,…
- 12 Sep 2020
Guide, cracked
RT WING NR 2 MAIN FLAP CARRIAGE INBOARD AFT TRACK GUIDE CRACKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED RT NR 2 MAIN FLAP CARRIAGE INBOARD AFT TRACK…
- 11 Sep 2020
Rod, chafed
CHAFE LOWER ROD ASSEMBLY AS MARKED ON PILOTS DV WINDOW. C-CHECK RO 9/24/2020. BLENDED CHAFED AREA ON LOWER ROD ASSEMBLY, IAW EMB-175 AMM. ROD DIAMETER BEFORE…
- 11 Sep 2020
Rod, chafed
CHAFE LOWER ROD ASSEMBLY AS MARKED ON CO-PILOTS DV WINDOW. C-CHECK RO 9/24/2020. BLENDED CHAFFED AREA ON LOWER ROD ASSEMBLY, IAW EMB-175 AMM. ROD DIAMETER…
- 10 Sep 2020
Crossbeam, corroded
CORROSION FWD WET AREA FR 17 CROSSBEAM AS MARKED IN BETWEEN LT AND RT FLOOR TRACKS. C-CHECK RO 9/24/2020. PERFORMED CUTOUT OF CORROSION ON FRAME 17 CROSSBEAM.…
- 10 Sep 2020
Seat Track, corroded
CORROSION FWD WET AREA LT FLOOR TRACK CORRODED AS MARKED AT FR 17. C-CHECK RO 9/24/2020. PERFORMED CUTOUT OF CORROSION ON FRAME 17 LT FLOOR TRACK. FABRICATED…
- 10 Sep 2020
Structure, chafed
RT ENGINE, INBOARD AND OUTBOARD CHEVRON TURKEY FEATHERS ARE CHAFED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED RT ENGINE, INBOARD AND OUTBOARD CHEVRON TURKEY…
- 10 Sep 2020
Crossbeam, broken
FRAME 86 CROSSBEAM LT AND RT PANEL SUPPORTS BROKEN OFF. C-CHECK RO 9/24/2020. REMOVED AND REPLACED FR 86 CROSSBEAM LT AND RT PANEL SUPPORTS, PER SRM. SEE…
- 10 Sep 2020
Floor Support, corroded
CORROSION, AFT WET AREA RT PANEL SUPPORT HAS CORROSION AT FR 90, AS MARKED. C-CHECK RO 9/24/2020. REMOVED CORROSION, MATERIAL LOSS FOUND TO BE BEYOND ANY SRM…
- 10 Sep 2020
Floor Support, corroded
CORROSION, AFT WET AREA RT PANEL SUPPORT HAS CORROSION AT FR 90, AS MARKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED RT PANEL SUPPORT AT FRAME 90, REF SRM.
- 10 Sep 2020
Floor Support, corroded
CORROSION, AFT WET AREA FR 87 PANEL SUPPORT FWD OF RT SHEAR PANEL CORRODED, AS MARKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED AFT WET AREA FR 87 PANEL…
- 10 Sep 2020
Floorbeam, corroded
CORROSION, AFT WET AREA RT FLOOR BEAM CORRODED AROUND FASTENER, AS MARKED AT FR 87. C-CHECK RO 9/24/2020. REMOVED AND REPLACED AFT WET AREA RT FLOOR BEAM FR…
- 10 Sep 2020
Floor Support, corroded
CORROSION, AFT WET AREA RT FLOOR BEAM UPPER SHEET HAS CORROSION AS MARKED FR 85-86. C-CHECK RO 9/24/2020. REMOVED AND REPLACED AFT WET AREA RT FLOOR BEAM…
- 10 Sep 2020
Floorbeam, corroded
CORROSION, AFT WET AREA LT FLOOR BEAM HAS CORROSION, AS MARKED AT FR 87. C-CHECK RO 9/24/2020. REMOVED DAMAGED AFT WET AREA LT FLOOR BEAM. LOCATED, DRILLED,…
- 10 Sep 2020
Seat Track, corroded
CORROSION, AFT WET AREA LT FLOOR SEAT TRACK END CORRODED, AS MARKED FR 84-85. C-CHECK RO 9/24/2020. REMOVED COROSION, REF EMB SRM. PERFROMED PERNANENT REPAIR…
- 10 Sep 2020
Seat Track, corroded
CORROSION, AFT WET AREA RT FLOOR SEAT TRACK END CORRODED, AS MARKED FR 84-85. C-CHECK RO 9/24/2020. PERFORMED SEAT TRACK SPLICE REPAIR AT AFT WET AREA RT…
- 10 Sep 2020
Splice, corroded
CORROSION ON SPLICE PLATE INSTALLED AT FWD FLANGE OF PANEL 192DL. C-CHECK RO 9/24/2020. REMOVED SPLICE PLATE FWD FLANGE OF PANEL 192 DL AND INSTALLED NEW…
- 10 Sep 2020
Angle, corroded
CORRODED 3 EA LOWER ANGLES AND 1 EA CRACK RECEPTACLE ON PANEL 1441FR. C-CHECK RO 9/24/2020. REMOVED AND REPLACED 2 EA LOWER ANGLES. PERFORMED BLENDOUT ON (1)…
- 9 Dec 2019
Brake, failed
WHILE IN FLIGHT WE HAD INTERMITTENT BRK LH/RH FAIL MESSAGES. WE COORDINATED WITH DISPATCH, DECLARED AN EMERGENCY AND LANDED AFTER ALL APPLICABLE CHECKLIST AND…
- 18 Mar 2001
Switch, dirty
DURING TAKEOFF ROLL AT MCO (85KTS) THE FORWARD CENTER CARGO A-SYSTEM LIGHT ILLUMINATED. PLACED A-SYSTEM LIGHT ON MEL. CLEANED SWITCHES AND OPERATIONAL CHECKS…
- 27 Aug 2000
Wire, broken
DURING A MAINTENANCE LINE CHECK, THE EMERGENCY TRACK LIGHTING IN RIGHT AFT CABIN WAS FOUND INOPERATIVE. REMOVED AND REPLACED A BROKEN WIRE IN C SECTION…
- 6 Jul 2000
Power Supply, inoperative
DURING A MAINTENANCE LINE CHECK THE FORWARD POWER SUPPLY FAILED THE SELF TEST OF THE EMERGENCY LIGHTS. REMOVED AND REPLACED THE FORWARD CABIN EMERGENCY…
- 10 Apr 2000
Battery Pack, inoperative
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY FLOOR PATH LIGHTING WAS FOUND TO BE INOPERATIVE FORWARD OF SEAT 33HJK IN THE AFT CABIN. REMOVED AND REPLACED…
- 22 Jan 2000
Power Supply, inoperative
DURING A LINE MAINTENANCE CHECK, THE OVERWING EMERGENCY LIGHTS BATTERY POWER SUPPLY FAILS TEST. REMOVED AND REPLACED THE OVERWING POWER SUPPLY. OPERATIONALLY…
- 15 Jan 2000
Light, inoperative
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY LIGHT (WHITE BAR) BEHIND THE COCKPIT WAS FOUND TO NOT ILLUMINATE ON THE CENTER FORWARD BULKHEAD. FOUND A BROKEN…
- 18 Oct 1999
Web, cracked
DURING A HEAVY MAINTENANCE CHECK IN THE CARGO BAY STA 1541 AT LGR 43L WAS FOUND TO HAVE A 1 INCH CRACK IN THE WEB UNDER THE CARGO ROLLER TRACKS. REMOVED WEB…
- 18 Oct 1999
Angle, corroded
DURING A HEAVY MAINTENANCE CHECK IN THE AFT CARGO COMPARTMENT CORROSION WAS FOUND AT STA 1964 AT LBL 50 TO RBL 50. REMOVED AFT THRESHOLD ANGLE AND FABRICATED…
- 18 Oct 1999
Oxygen Gen, discharged
DURING A HEAVY MAINTENANCE CHECK, THE OXYGEN GENERATOR AT SEAT 20D AND 20E WAS FOUND DISCHARGE. REMOVED AND REPLACED OXYGEN GENERATOR PER MM 352003.
- 18 Oct 1999
Intercostal, corroded
DURING A HEAVY MAINTENANCE CHECK INTERCOSTAL AT STA 495X EQUALS PLUS AND MINUS 45 WAS FOUND CORRODED AT THE UPPER END. 100 PERCENT MATERIAL LOSS WAS NOTED.…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, SEAT TRACK AT STA 465 48 RT IN THE MAIN CABIN WAS FOUND CORRODED. REMOVED AND REPLACED SEAT TRACK PER SRM 537000.
- 18 Oct 1999
Channel, corroded
DURING A HEAVY MAINTENANCE CHECK IN THE AFT CARGO PIT STA 1841 TO 1964 RT SIDE LOWER CENTER FLOOR TO LOWER SIDE FLOOR Z CHANNEL HAS CORROSION ON ENTIRE…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 459 X MINUS 30 AND Z MINUS 18 WAS FOUND CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS.…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 459 X PLUS 20 Z MINUS 18 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS.…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1841 X PLUS WAS FOUND CORRODED. REMOVED CORROSION FOUND OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 495 X PLUS 62 Z MINUS 18 WAS FOUND CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 414 X MINUS 20 WAS FOUND CORRODED ON THE UPPER SURFACE. REMOVED CORROSION MATERIAL LOSS FOUND TO BE…
- 18 Oct 1999
Tie Down, corroded
DURING A HEAVY MAINTENANCE CHECK, THE TIE DOWN CHANNEL AT STA 795 TO 859 WAS FOUND CORRODED AT RBL 50. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR BOARD SUPPORT AT STA 1902 TO 2607 X MINUS 57 WAS FOUND TO BE CORRODED. REMOVED CORRODED SUPPORT FOUND OUT OF…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT DOG BONE AT STA 1914 X MINUS 54 WAS FOUND TO BE CORRODED. REMOVED CORRODED FLOOR SUPPORT DOG BONE AND…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT CHANNEL AT STA 440 RBL 70 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED AND…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT AT STA 1887 X EQUALS PLUS 91 TO MINUS 91 WAS FOUND TO BE CORRODED. REMOVED FABRICATED AND INSTALLED NEW…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT AT STA 825 FROM RBL 30 TO RBL 50 WAS FOUND TO BE CORRODED. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT AND…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1902 TO 1965 WAS FOUND TO BE CORRODED. CORROSION REMOVED WAS FOUND TO BE OUT OF LIMITS. REMOVED SEAT…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, ALL LAVATORY SUPPORT RAILS FROM STA 1841 TO 1886 36LT TO 36RT WERE FOUND TO BE CORRODED. REMOVED AND INSTALLED NEW LAV…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE LOWER AFT RT GALLEY BOTTOM FLANGE WAS FOUND CORRODED. REMOVED FABRICATED ANGLES AND INSTALLED PER SAMPLE.
- 18 Oct 1999
Splice, corroded
DURING A HEAVY MAINTENANCE CHECK THE HAT SPLICE NEEDS TO BE FABRICATED FROM STA 795 TO 859 AT X MINUS 50 IN CONJUNCTION WITH SEAT TRACK REPAIR AT SAME STA.…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 795 TO 825 LBL 6 WAS FOUND TO BE CORRODED. FABRICATED SEAT TRACK PER SAMPLE AND INSTALLED PER SRM…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT DOG BONE AT STA 1841 X PLUS 10 TO 26 WAS FOUND TO BE CORRODED. REMOVED FABRICATED AND INSTALLED FLOOR…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 1841 X EQUALS PLUS 27 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS.…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 440 TO 470 AT RBL 85 WAS FOUND TO BE CORRODED. SEAT TRACK WAS FOUND TO BE EXFOLIATED COMPLETELY…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, A FLOOR SUPPORT AT STA 824 LBL 86 WAS FOUND TO BE BROKEN. REMOVED AND INSTALLED SUPPORT IAW 513501.
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STA 1914 TO 2007 AT X PLUS 23 WAS FOUND TO BE CORRODED. REMOVED CORRODED SUPPORT AND INSTALLED NEW…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 795 TO 825 LBL 25 WAS FOUND TO BE CORRODED. REMOVED CORROSION AND INSTALLED FABRICATED PARTS PER SRM…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT DOG BONE AT STA 1910 X MINUS 60 TO X MINUS 86 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT…
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT STA 1884 TO 2007 X MINUS 23 WAS FOUND TO BE CORRODED. REMOVED AND REPLACED SUPPORT IAW SRM 513101.
- 18 Oct 1999
Seat Track, cracked
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 808 RBL 95 WAS FOUND TO BE CRACKED. REMOVED AND REPLACED STRAP IAW 504101.
- 18 Oct 1999
Channel, corroded
DURING A HEAVY MAINTENANCE CHECK, THE TIE DOWN CHANNEL AT STA 440 TO 470 RBL 65 WAS FOUND CORRODED. REMOVED AND REPLACED CORRODED SEAT TRACK REF SRM 531101…
- 18 Oct 1999
Seat Track, corroded
DURING A HEAVY MAINTENANCE CHECK, THE SEAT TRACK AT STA 440 32 LT WAS FOUND CORRODED. REMOVED FABRICATED AND INSTALLED SEAT TRACK PER SRM 513101.
- 18 Oct 1999
Support, corroded
DURING A HEAVY MAINTENANCE CHECK, THE LAV AND GALLEY SUPPORT NUT CLIP HOLE WAS FOUND TO BE CORRODED AT STA 1910 TO 2007 X PLUS 52. REMOVED GALLEY SUPPORT AND…
- 18 Oct 1999
Rib, cracked
DURING A HEAVY MAINTENANCE CHECK, THE RT HORIZONTAL STABILIZER CLOSING RIB WAS FOUND CRACKED IN TWO PLACES APPROXIMATELY STA XE 26. REMOVED DAMAGED AREA PER…
- 18 Oct 1999
Angle, cracked
DURING A HEAVY MAINTENANCE CHECK, THE RT INBOARD ELEVATOR TRAILING EDGE WAS FOUND TO HAVE A CRACK IN THE INBOARD CORNER. REMOVED CORNER CAP AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 50 END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW FITTING…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 51 END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW FITTING…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 52 RIGHT AND LEFT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 51 RIGHT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 48 RIGHT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 48 LEFT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 49 RIGHT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 49 LEFT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Endcap, corroded
DURING A HEAVY MAINTENANCE CHECK, THE CENTER WING LOWER BARREL AT STA 1521 LGR 50 RIGHT END CAP FITTING WAS FOUND TO BE CORRODED. REMOVED AND FABRICATED NEW…
- 18 Oct 1999
Stringer Clip, cracked
DURING A HEAVY MAINTENANCE CHECK, THE RIGHT WING NUMBER THREE TANK STA XORS 402 STRINGER CLIP IS CRACKED AT STRINGER 7. REMOVED FABRICATED AND INSTALLED NEW…
- 14 Aug 1999
N1 Sensor, inoperative
AIRCRAFT ABORTED TAKEOFF AT 120 KNOTS AS NUMBER TWO ENGINE DIDN'T MAKE REDUCED N1. OPERATIONALLY CHECKED THE NUMBER TWO ENGINE IAW DC-10 MM 710000.…
- 17 Jul 1999
Coffeemaker, failed
DURING FLIGHT, NUMBER THREE COFFEEMAKER SPARKED THEN THE GALLEY POWER TRIPPED OFF LINE. GALLEY COFFEEMAKER CIRCUIT BREAKERS THEN PULLED. REMOVED AND REPLACED…
- 6 Jun 1999
Light, inoperative
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING ON THE RIGHT SIDE AT SEAT ROW 37 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY…
- 28 Mar 1999
Cover, out of position
DURING A LINE MAINTENANCE CHECK, THE L1 DOOR WOULD NOT RELEASE FROM THE DOOR OPENING. FOUND THE LOWER ESCAPE SLIDE COVER JAMMED INTO DOOR FRAME WITH ENOUGH…
- 31 Jan 1999
Wire, failed
DURING A LINE MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK AFT OF THE R1 DOOR WAS FOUND TO BE INOPERATIVE. REPAIRED WIRES ON THE EMERGENCY EXIT TRACK,…
- 10 Jan 1999
Wire, pinched
DURING FLIGHT, THE OXYGEN MASKS IN THE FORWARD CABIN EJECTED. TROUBLESHOT PROBLEM TO BE A PINCHED MUX SYSTEM CABLE AT SEAT ROWS 6ABC AND 7ABC. REPLACED THE…
- 4 Jan 1999
Power Supply, inop
DURING A LINE MAINTENANCE CHECK, THE LEFT OVERWING EMERGENCY POWER SUPPLY FAILED TEST. REMOVED AND REPLACED THE LEFT OVERWING EMERGENCY POWER SUPPLY.…
- 31 Dec 1998
Valve, failed
DURING CLIMBOUT, CREW REPORTED UNABLE TO MAINTAIN CABIN ALTITUDE. AT 31,000 FEET THE ALTITUDE WARNING HORN SOUNDED AND DESCENDED TO 19,000 FEET BEFORE THE…
- 8 Oct 1998
Wall, delaminated
DURING A MAINTENANCE CHECK, THE CENTER WALL BETWEEN THE P LIFT AND C LIFT WAS FOUND TO BE DELAMINATED. REMOVED AND REPLACED THE DAMAGED SECTION OF HONEYCOMB.…
- 7 Oct 1998
Intercostal, corroded
DURING A MAINTENANCE CHECK AN INTERCOSTAL THAT RUNS OUTBOARD TO THE RIGHT OF THE P LIFT WAS FOUND CORRODED. REMOVED CORRODED INTERCOSTAL AND FABRICATED A NEW…
- 27 Sep 1998
Slide, failed test
DURING A LINE MAINTENANCE CHECK, THE R3 DOOR SLIDE PRESS TO TEST LIGHT WAS CONTINUOUSLY ILLUMINATED. FOUND SLIDE PRESSURE TO BE LOW AND REMOVED AND REPLACED…
- 29 Jul 1998
Wire, broken
DURING A LINE MAINTENANCE CHECK, THE MID CABIN RIGHT SIDE EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. FOUND A BROKEN WIRE. WIRE REPAIRED AND LIGHTS…
- 26 May 1998
Stringer, corroded
DURING HEAVY CHECK, FORWARD CARGO SUMP AREA BETWEEN STA 899 AND 919 STR 52 WAS FOUND TO HAVE LEVEL 2 CORROSION. MATERIAL LOSS IS OUT OF LIMITS. MATEIRIAL…
- 26 May 1998
Spar Cap, cracked
DURING HEAVY CHECK, THE RIGHT HAND HORIZONTAL STABILIZER XFS77 XE57 WAS FOUND TO HAVE A 2 INCH CRACK AS VIEWED FROM INTERSPAR BOX ON TOP OF FORWARD SPAR AT…
- 26 May 1998
Seat Track, corrded
DURING HEAVY CHECK IN THE WASTE TANK COMPARTMENT RIGHT TUNNEL 186 STATION 2007 AT THE FLOOR LEVEL OUTER FLOORBEAM WAS CORRODED ON THE END. MATERIAL…
- 26 May 1998
Latch Solenoid, inoperative
DURING HEAVY CHECK, THE FLIGHT ATTENDANT L-4 OXYGEN BOX WOULD NOT OPEN DURING OXYGEN DROP CHECK. REMOVED AND REPLACED LATCH SOLENOID AT L-4 FLIGHT ATTENDANT…
- 13 May 1998
Angle, corroded
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL LEG IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED…
- 13 May 1998
Support, corroded
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL 186 END AT FLOOR SUPPORT BEAM END IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION…
- 13 May 1998
Support, cracked
DURING HEAVY CHECK, THE REMOVAL OF A FLOOR PANEL TO FACILITATE MAINTENANCE REVEALED A CRACKED FLOOR SUPPORT UNDER THE PATIO FLOOR PANEL. FABRICATION OF ONE…
- 13 May 1998
Bracket, cracked
DURING HEAVY CHECK, RIGHT HAND LATERAL CONTROL SPOILER MIXER BRACKET HAS A .25 CRACK NOTED ON AFT SPOILER BRACKET ON AFT SIDE AT TRANSITION RADII BETWEEN THE…
- 13 May 1998
Rib, cracked
DURING HEAVY CHECK, THE RIGHT HAND LEADING EDGE INTERNAL HAS A THREE INCH CRACK ON THE LOWER RIB APPROX AT STATION 491. FABRICATED TWO EACH DOUBLERS 7975 .063…
- 2 Apr 1998
Smoke Detector, malfunctioned
TWO PASSENGERS WERE CAUGHT SMOKING IN THE LAVATORIES AND THE SMOKE DETECTORS FAILED TO GO OFF. ALL LAVATORY SMOKE DETECTORS SUBJECTED TO LIVE SMOKE TEST WITH…
- 26 Feb 1998
Fastener, sheared
DURING A SCHEDULED MAINTENANCE INSPECTION, THE AFT LOWER RIGHT HAND FASTENER WAS FOUND SHEARED OFF ON THE NUT SIDE FOR THE NUMBER FOUR BANJO FITTING…
- 14 Aug 1997
Power Supply, inoperative
THE OVERWING EMERGENCY LIGHT POWER SUPPLY DOES NOT PASS THE EMERGENCY LIGHT TEST. REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY PACK, SYSTEM TESTED GOOD.
- 13 Aug 1997
Pneumatic Valve, lack of lube
WHILE CONDUCTING A TEST SLIDE/RAFT DEPLOYMENT AT THE L-3 DOOR, THE DOOR WOULD NOT OPEN PNEUMATICALLY. DOOR WAS OPERATED MANUALLY AND THE SLIDE/RAFT DEPLOYED…
- 6 May 1997
Batteries, discharged
THE L-3 DOOR SLIDE PRESS TO TEST LIGHT WAS FOUND TO BE DIM. REMOVED AND REPLACED TEST LIGHT BATTERIES. SLIDE TESTED GOOD.
- 9 Apr 1997
Light, inoperative
R1 DOOR FORWARD EMERGENCY EXIT LIGHT WAS FOUND INOP. RELAMPED EMERGENCY LIGHT AND FUNCTIONALLY TESTED IN ACCORDANCE WITH MM 33-00. NO DISCREPANCIES NOTED.
- 8 Apr 1997
Smoke Det Lamp, failed
POSITION 2 CARGO SMOKE DETECTOR DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED WITH NO DISCREPANCIES NOTED.
- 8 Mar 1997
Coffeemaker, dirty
DURING FLIGHT, THERE WAS AN ELECTRICAL SMOKE SMELL IN THE AFT GALLEY. TURNED GALLEY POWER OFF AND SMELL WENT AWAY. FOUND NUMBER 7 COFFEE MAKER BASE DIRTY,…
- 27 Feb 1997
Power Supply, inoperative
FORWARD OVERHEAD EMERGENCY LIGHT POWER SUPPLY FAILED SELF TEST. REMOVED AND REPLACED POWER SUPPLY IN ACCORDANCE WITH 33-51-01 AND OPS CHECKED GOOD.
- 7 Jan 1997
Light, inoperative
FORWARD CABIN EMERGENCY TRACK LIGHTING WAS FOUND INOP IN AFT HALF OF FORWARD CABIN. REPAIRED SHORTED SUPPLY WIRING AT SEAT 8HJK, OPS CHECKED GOOD.
- 5 Jan 1997
Switch Assy, inoperative
L1 DOOR EMERGENCY SLIDE PUSH TO TEST BUTTON WAS INOP. REMOVED AND REPLACED COMPLETE BATTERY, PLUG AND SWITCH ASSEMBLY, OPS CHECKED GOOD.
- 17 Nov 1996
Smoke Detector, failed
THE NUMBER 1 SMOKE DETECTOR WOULD NOT TEST. FOUND LAMP BURNED OUT ON NUMBER 1 AFT CENTER CARGO SMOKE DETECTOR. RELAMPED AND DETECTOR, TESTED GOOD.
- 6 Oct 1996
Skin, damaged
DURING HEAVY MAINTENANCE, FOUND LIP BENT AND TORN ON CUT OUT, SECOND HINGE FROM OUTBOARD END ON RIGHT HAND ELEVATOR. REMOVED DAMAGED AREA, FABRICATED AND…
- 6 Oct 1996
Skin, damaged
DURING HEAVY MAINTENANCE, FOUND LIP TORN ON CUT OUT, SECOND HINGE FROM OUTBOARD END ON LEFT HAND ELEVATOR. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED…
- 3 Oct 1996
Angle, cracked
DURING HEAVY MAINTENANCE, FOUND A CRACKED L-ANGLE IN THE NUMBER 1 PYLON AT APPROXIMATE STATION 272 OUTBOARD END, IN BACK AND ABOVE PRECOOLER. REMOVED EXISTING…
- 28 Sep 1996
Strut, scratched
DURING HEAVY MAINTENANCE, FOUND SCRATCHES IN THE CHROME ON THE OUTER CYLINDER OF THE RIGHT MAIN LANDING GEAR. REMOVED AND REPLACED THE RIGHT MAIN LANDING GEAR…
- 28 Sep 1996
Strut, scratched
DURING HEAVY MAINTENANCE, FOUND SCRATCHES ON THE INNER AND OUTER CYLINDERS OF THE LEFT MAIN LANDING GEAR. ALSO, FOUND DAMAGED UPPER AND LOWER BEARINGS.…
- 27 Sep 1996
Angle, broken
DURING HEAVY MAINTENANCE, FOUND BROKEN PANEL SUPPORT ANGLE AT BS 1801 RBL 32. FABRICATED AND INSTALLED NEW SUPPORT ANGLE IN ACCORDANCE WITH SRM 53-00-01 AND…
- 27 Sep 1996
Angle, broken
DURING HEAVY MAINTENANCE, FOUND NON STANDARD INSTALLATION OF SUPPORT ANGLE AT BS 1701 RBL 5. FABRICATED AND INSTALLED NEW SUPPORT ANGLE IN ACCORDANCE WITH SRM…
- 27 Sep 1996
Skin, dented
DURING HEAVY MAINTENANCE, FOUND A DENT APPROXIMATELY 12 INCHES FROM THE INBOARD END OF THE RIGHT HAND HORIZONTAL STABILIZER. REMOVED DAMAGED AREA, FABRICATED…
- 26 Sep 1996
Frame, cracked
DURING HEAVY MAINTENANCE, FOUND A CRACK IN THE LONGERON HOLE FOR LONGERON 48L AT BS 1501. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR DOUBLER IN…
- 24 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 1887, LBL 30 AND RBL 24. REMOVED CORRODED SECTIONS, FABRICATED AND INSTALLED FILLERS AND…
- 22 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 775 TO 830, RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND…
- 22 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 735 TO BS 737 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND…
- 21 Sep 1996
Floorbeam, cracked
DURING HEAVY MAINTENANCE, FOUND FLOORBEAM CRACKED AT BS 735 IN THE LOWER GALLEY AREA. CUT OUT MATERIAL, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH…
- 21 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 823 IN THE FORWARD GALLEY. REMOVED CORROSION, FABRICATED AND INSTALLED A FILLER AND DOUBLER…
- 21 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 685 IN THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND…
- 21 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 750 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED…
- 20 Sep 1996
Frame, cracked
DURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 45R. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND…
- 20 Sep 1996
Frame, cracked
DURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 50L. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND…
- 20 Sep 1996
Bulkhead, cracked
DURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 48R. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND…
- 20 Sep 1996
Floorbeam, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM BELOW THE THRESHOLD ON THE FORWARD SIDE OF THE SERVICE ELEVATOR IN THE LOWER GALLEY. REMOVED…
- 20 Sep 1996
Intercostal, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION AROUND NUTPLATE UNDER SEAT TRACK AT BS 1841, RBL 27. REMOVED INTERCOSTAL, FABRICATED AND INSTALLED A NEW INTERCOSTAL…
- 19 Sep 1996
Skin, corroded
DURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1741, LONGERON 44. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN…
- 19 Sep 1996
Skin, corroded
DURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1721, LONGERON 42. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN…
- 19 Sep 1996
Skin, corroded
DURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1761, LONGERON 44. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN…
- 19 Sep 1996
Skin, gouged
DURING HEAVY MAINTENANCE, FOUND 3 GOUGES IN THE LEFT SIDE OF THE FUSELAGE AT BS 715, JUST ABOVE THE FLOOR LINE. BLENDED OUT GOUGES IN ACCORDANCE WITH SRM…
- 19 Sep 1996
Skin, gouged
DURING HEAVY MAINTENANCE, FOUND A DENT ON THE LEFT SIDE OF THE FUSELAGE AT BS 560 JUST BELOW THE FLOOR LINE. BLENDED OUT DENT, FABRICATED AND INSTALLED A…
- 19 Sep 1996
Bulkhead, cracked
DURING HEAVY MAINTENANCE, FOUND A CRACK EXTENDING BEYOND THE STOP DRILL LOCATION IN AN EXISTING REPAIR ON THE BS 1841 BULKHEAD. REMOVED EXISTING REPAIR AND…
- 19 Sep 1996
Skin, dented
DURING HEAVY MAINTENANCE, FOUND A SMOOTH DENT AT BS 765, BELOW LONGERON L-27. FABRICATED AND INSTALLED A DOUBLER IN ACCORDANCE WITH SRM 53-20-00 FIGURE 13.
- 19 Sep 1996
Ceiling Support, cracked
DURING HEAVY MAINTENANCE, FOUND CEILING SUPPORT CRACKED IN THE FORWARD CARGO COMPARTMENT AT BS 919, RBL 67. REMOVED CRACKED CEILING SUPPORT, FABRICATED AND…
- 18 Sep 1996
Skin, chaffed
DURING HEAVY MAINTENANCE, FOUND CHAFING SPOTS ON THE LOWER SURFACE OF THE LEFT HAND NUMBER 3 SPOILER. FABRICATED AND INSTALLED A REPAIR ON THE LOWER SURFACE…
- 17 Sep 1996
Frame, corroded
DURING HEAVY MAINTENANCE, FOUND CORROSION AROUND INSERTS ON THE AFT SIDE OF THE DOOR FRAME IN THE AFT CARGO COMPARTMENT. REMOVED CORROSION, FABRICATED AND…
- 17 Sep 1996
Skin, chaffed
DURING HEAVY MAINTENANCE, FOUND CHAFING SPOTS ON THE LOWER SURFACE OF THE LEFT HAND NUMBER 4 SPOILER. FABRICATED AND INSTALLED A REPAIR ON THE LOWER SURFACE…
- 17 Sep 1996
Skin, dented
DURING HEAVY MAINTENANCE, FOUND A DENT IN THE INBOARD FOREFLAP ABOVE AND BEHIND THE MAIN GEAR ON THE RIGHT SIDE. FABRICATED AND INSTALLED A PERMANENT REPAIR…
- 3 Sep 1996
Smoke Detector, inoperative
AFT LAV-E SMOKE DETECTOR ON CONTINUOUSLY. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED NORMAL.
- 22 Aug 1996
Skin, corroded
DURING A-CHECK INSPECTION, FIVE DIMPLES WERE NOTED IN LOCALIZED AREAS ON THE EXTERIOR OF THE FUSELAGE SKIN. THE DIMPLES ARE APPROXIMATELY 0.50 INCH IN…
- 14 Jul 1996
Check Valve, inoperative
UNABLE TO PRESSURIZE CABIN, DUMPED APPROXIMATELY 30,000 POUNDS OF FUEL AND RETURNED TO LAS. FOUND CHECK VALVE (P/N 7012-505) TO BE INOP IN NUMBER 2 PACK AND A…
- 4 Jun 1996
Smoke Det, inoperative
FORWARD CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR, OPS CHECK OK.
- 3 Jun 1996
Smoke Detector, inoperative
THE SMOKE DETECTOR IN THE LAV JUST AFT OF DOOR R1 WAS FOUND TO BE INOP. REMOVED AND REPLACED THE SMOKE DETECTOR, OPS CHECK OK.
- 30 Mar 1996
Connector, faulty
THE SMOKE DETECTOR IN LAVATORY 'A' WAS FOUND TO BE INOPERATIVE. REPLACED ELECTRICAL CONNECTOR AT SMOKE DETECTOR. DETECTOR OPS CHECKED NORMAL.
- 19 Feb 1996
Smoke Detector, failed
LAVATORY B-SMOKE DETECTOR WILL NOT RESET. REMOVED AND REPLACED SMOKE DETECTOR AND PREFORMED SELF TEST, OPS CHECKED OK.
- 1 Feb 1996
Wire, broken
THE L-1 DOOR SLIDE PUSH TO TEST DOES NOT ILLUMINATE WHEN PRESSED. REPAIRED BROKEN WIRE AT BATTERY HOLDER AND SLIDE TESTED GOOD.
- 15 Dec 1995
Slide Batteries, faulty
THE R-2 DOOR EVACUATION SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR THE EVACUATION SLIDE AND SELF TESTED IAW MM 25-61-03, OPS CHECKED GOOD.
- 15 Dec 1995
Smoke Det Lamp, failed
THE NUMBER 3 CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR AND UNIT OPS CHECKED GOOD.
- 6 Dec 1995
Skin, corroded
DURING A SCHEDULED INSPECTION, THE FUSELAGE SKIN WAS FOUND BULGING WITH A PULLED FASTENER AT FRAME STATION 1902 BETWEEN LONGERONS 45R AND 48R. THE CAUSE OF…
- 4 Dec 1995
Pan, cracked
DURING A SCHEDULED INSPECTION, THE AFT CARGO DOOR WAS FOUND WITH A .75 INCH CRACK IN THE AFT DOOR PAN. THE CRACK EXTENDED FROM AN EXISTING FASTENER HOLE TO…
- 1 Sep 1995
Test Light Batt, discharged
THE R-2 DOOR SLIDE INTEGRITY TEST LIGHT DID NOT ILLUMINATE WHEN PRESSED. REMOVED AND REPLACED TEST BATTERIES, AND SLIDE TESTED GOOD.
- 15 Jul 1995
Eel Power Supply, failed
FOUND THE AFT CABIN EMERGENCY FLOOR LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT CABIN POWER SUPPLY PER MM 33-51-01. LIGHTS TESTED GOOD.
- 9 Apr 1995
Smoke Detector, failed
LAVATORY J SMOKE DETECTOR CONTINUOUSLY GOING OFF. REMOVED AND REPLACED SMOKE DETECTOR IN LAV J. OPS CHECKS GOOD IAW MM 26-29-00.
- 8 Mar 1995
Eel Power Supply, failed
FORWARD CABIN EMERGENCY LIGHTS FAIL TEST. REPLACED FORWARD CABIN EMERGENCY LIGHTS POWER SUPPLY AND OPS CHECK GOOD.
- 11 Feb 1995
Eel Power Pack, failed
MSP - FORWARD CABIN EMERGENCY TRACK LIGHTING INOPERATIVE IN BOTH AISLES. REMOVED AND REPLACED FORWARD SECTION BATTERY POWER PACK, SPLICED BROKEN WIRES,…
- 22 Jan 1995
Hyd Line, leaking
MSP - NR 2 HYDRAULIC SYSTEM PRESSURE LINE CHAFING WITH STANDBY RUDDER PRESSURE LINE CAUSING A LEAK BELOW NR 2 INLET DUCT. REPLACED BOTH LINES AND LEAK CHECKED…