N151AA
2006 Tague Larry PIONEER 200 experimental, amateur built FAA →
reservations
aircraft radio
earlier registrations
1 past record
- 2006
NTSB
- 26 Mar 1987
incident, Tuba City AZ
service difficulty reports
8 reports
- 16 Sep 1996
Apu, oil leak
HNL - FLT 022 - SMELLS LIKE APU OIL IS IN AIR PACKS. STRONGEST SMELL IN COCKPIT AND GALLEY WITH NR 1 PACK ON. WITH NR 1 PACK OFF, SMELL IS STILL EVIDENT IN…
- 7 May 1996
Bolt, sheared
LAX - FLT NR 9 - LOSS OF ALL HYDRAULIC FLUID IN SYSTEM 3 ON CLIMB-OUT. RETURNED TO LAX FOR LANDING. FOUND 2 SHEARED BOLTS ON HORIZONTAL STAB TRIM AUX HYD…
- 15 Dec 1995
Fitting, corroded
TULE - FOUND CORROSION ON FITTING OUTBOARD OF LEFT GEAR, ATTACHED TO TRUNNION. REMOVED CORRODED FITTING AND REPLACED WITH NEW PART. (M)
- 14 Dec 1995
Service Door, corroded
TULE - FOUND MID LAVATORY SERVICE DOOR CORRODED ON INSIDE SURFACE. INSTALLED NEW LAVATORY SERVICE DOOR. (M)
- 14 Dec 1995
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 43L, STATION 1098 TO 1110. REMOVED AND REPLACED STRINGER SECTION PER FSO 7349, DATED 12-12-95 AND SRM 51-21-01. (M)
- 13 Dec 1995
Support, corroded
TULE - FOUND CORROSION ON FLOOR SUPPORT BETWEEN STRINGER 49L AND 49R, STATION 1099. REMOVED AND REPLACED FLOOR SUPPORT PER AARD 51-01-00-5, TREAT AND PAINT. (M)
- 12 Dec 1995
Support, corroded
TULE - FOUND CORROSION ON TOP OF SUPPORT, STATION 1908. FABRICATE A U-CHANNEL FROM 2024 T-3, INSTALL UNDER SUPPORT ATTACH WITH .1875 INCH FASTENERS…
- 11 Dec 1995
Support, corroded
TULE - FOUND CORROSION ON TOP OF FLOOR SUPPORT, BETWEEN NR 7 AND NR 8 SEAT TRACK, STATION 1908. REMOVED DAMAGED FLOOR SUPPORT AND REPLACED WITH NEW PER AARD…