N14337
1987 Boeing 737-3TO standard FAA →
earlier registrations
2 past records
- 1987
- 1973
service difficulty reports
63 reports
- 19 May 2006
Stiffener, cracked
INSPECTION FOUND A CRACK IN THE WING CENTER SECTION REAR SPAR VERTICAL STIFFENER AT LBL AND RBL 6.15. THE VERTICAL STIFFENER WAS REPAIRED IAW ECRA 5714-01018.
- 1 Mar 2006
Skin, corroded
INSPECTION FOUND FUSELAGE SKIN CORRODED AT STA 1009, S27L. THE CORRODED AREA WAS CUT OUT AND A DOUBLER WAS INSTALLED IAW SRM 53-00-01, REPAIR 31.
- 1 Mar 2006
Web, corroded
INSPECTION FOUND AFT PRESSURE BULKHEAD WEB FORWARD FACE CORRODED AT LEFT AND RIGHT CHANNEL, STA 1016, BL 0. A WEB AND CHANNEL REPAIR WAS INSTALLED IAW BOEING…
- 1 Mar 2006
Stringer, corroded
INSPECTION FOUND STRINGER 27L CORRODED JUST FORWARD OF STA 1016. A REPAIR SECTION WAS INSTALLED IAW SRM 53-00-03.
- 27 Feb 2006
Stringer, corroded
INSPECTION FOUND STRINGER 27L IN FORWARD BAGGAGE BIN CORRODED AT STA 440-460. AN ANGLE REPAIR WAS INSTALLED IAW SRM 53-00-03, FIGURE 201, DETAIL VI.
- 26 Feb 2006
Stringer, corroded
INSPECTION FOUND STRINGER 27L CORRODED AT STA 480-500B. A NEW SECTION OF STRINGER WAS SPLICED IN IAW SRM 53-00-03, FIGURE 201.
- 21 Feb 2006
Frame, cracked
INSPECTION FOUND A 1 INCH CRACK IN LT MAIN FRAME AT STA 616 JUST BELOW MAIN DECK FLOOR, LBL 0 TO LBL 60. REPAIRED FRAME IAW ECRA 5311-01158.
- 3 Mar 2005
Floorbeam, corroded
INSPECTION FOUND LEFT O/B EDGE OF FLOORBEAM UPPER CHORD CORRODED AT BS 277, LBL 19. THE CORRODED SECTION OF UPPER CHORD WAS REMOVED AND A NEW CHORD WAS…
- 2 Mar 2005
Threshold, corroded
INSPECTION FOUND R-1 DOOR THRESHOLD DRAIN FRAME CORRODED AT STA 294-342, BL 0 TO RBL 36. A CHORD WAS INSTALLED IAW SRM 51-40-02 AND DRAWING 55-45875.
- 2 Mar 2005
Floorbeam, corroded
INSPECTION FOUND LEFT O/B EDGE OF FLOORBEAM UPPER CHORD CORRODED AT BS 294.5, LBL 20. THE CORRODED SECTION OF UPPER CHORD WAS REMOVED AND A NEW CHORD WAS…
- 27 Feb 2005
Floorbeam, cracked
INSPECTION FOUND A 1.625 INCH CRACK IN FORWARD GALLEY FLOORBEAM WEB AT STA 312, RBL 18. THE WEB WAS REPAIRED IAW ECRA 5310-04462.
- 27 Feb 2005
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED IN E&E COMPARTMENT ON RT SIDE ABOVE AIRFONE CONTROL BOX AT STA 312, RBL 21. THE FLOORBEAM UPPER CHORD WAS REMOVED AND…
- 27 Feb 2005
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 312, RBL 21, RBL 36, AND RBL 49. THE FLOORBEAM UPPER CHORD WAS REMOVED AND REPLACED IAW SRM 53-00-51.
- 12 Sep 2004
Skin, dented
INSPECTION FOUND A DENT IN FUSELAGE SKIN AT STA 264 ABOVE S19L. THE SKIN WAS REPAIRED IAW ECRA 5330-03366. A DIP WAS ISSUED TO PERFORM A PERMANENT REPAIR IAW…
- 8 May 2004
Floorbeam, cracked
INSPECTION FOUND A 1 INCH CRACK IN FLOORBEAM AT STA 540, RBL 48. THE FLOORBEAM WAS REPAIRED IAW ECRA 5331-01146.
- 6 May 2004
Angle, cracked
INSPECTION FOUND A 1 INCH CRACK IN NR 1 PYLON ANGLE JUST AFT OF I/B MIDSPAR ATTACH BOLT. A NEW ANGLE WAS INSTALLED IAW SRM 51-40-00.
- 4 May 2004
Skin, cracked
INSPECTION FOUND A .5 INCH CRACK IN LEFT WING L/E NR 3 SLAT ACTUATOR CUTOUT. THE CRACK WAS STOP DRILLED AND A REPAIR DOUBLER WAS INSTALLED IAW SRM 57-40-01,…
- 4 May 2004
Angle, cracked
INSPECTION FOUND A 1.5 INCH CRACK IN ANGLE FOR RIGHT RAM AIR INLET AT BS 540, S22R. THE CRACKED SECTION WAS CUT OUT AND A NEW SECTION WAS INSTALLED IAW SRM…
- 1 May 2004
Seat Track, broken
THE RIGHT O/B SEAT TRACK UPPER LOBE BROKE DURING SEAT REMOVAL AT STA 887, RBL 34. THE SEAT TRACK WAS REMOVED AND REPLACED IAW SRM 53-00-52, FIGURE 204.
- 1 May 2004
Seat Track, broken
THE RIGHT I/B SEAT TRACK UPPER LOBE BROKE DURING REMOVAL AT STA 827. A SEAT TRACK REPAIR SECTION WAS INSTALLED IAW SRM 53-00-52.
- 24 Apr 2004
Charger, inoperative
THREE EMERGENCY LIGHTS OVER EMERGENCY ESCAPE HATCH ARE INOP. REPLACED BATTERY CHARGERS AND BATTERIES PER MM 33-51-51.
- 8 Mar 2002
Skin, cracked
INSPECTION FOUND A 1" CRACK IN CAPTAIN'S WINDSHIELD O/B POST OUTER SKIN AT UPPER CORNER. A REPAIR DOUBLER WAS INSTALLED IAW ECRA 5330-01104.
- 8 Mar 2002
Skin, cracked
INSPECTION FOUND TWO INCH CRACKS AT THE EDGES OF THREE LIGHTENING HOLES IN C-2 DOOR INNER SKIN OVER CENTER BALANCE SPRINGS. A 1" CRACK WAS FOUND AT THE EDGE…
- 7 Mar 2002
Web, cracked
INSPECTION FOUND A 1/2" CRACK IN WEB AT LIGHTENING HOLE AFT OF STA 1040 AND I/B OF TAIL COMPARTMENT ACCESS. A REPAIR WAS INSTALLED IAW ECRA 5320-01768.
- 7 Mar 2002
Skin, cracked
INSPECTION FOUND A 1.25" CRACK IN C-2 DOOR INNER SKIN AT AFT LOWER CORNER. THE SKIN WAS REPAIRED IAW ECRA 5230-01650.
- 6 Mar 2002
Spar Cap, cracked
INSPECTION FOUND A 1/2" CRACK AT HOLE IN SPAR CAP AT R/H WING MLG BEAM ATTACH FITTING. REPAIRED IAW ECRA 5740-02000. THE ITEM WAS PLACED ON DIP TO PERFORM AN…
- 4 Mar 2002
Skin, cracked
INSPECTION FOUND A 3" CRACK IN R/H HORIZONTAL STABILIZER LOWER SKIN AT REAR SPAR JUST I/B OF #4 ELEVATOR HINGE. A PERMANENT REPAIR DOUBLER WAS INSTALLED IAW…
- 2 Mar 2002
Skin, cracked
INSPECTION FOUND A 4" CRACK IN #4 L/E SLAT PANEL AT O/B ACTUATOR. REPAIRED IAW SRM 57-43-01.
- 2 Mar 2002
Keelbeam, chafed
INSPECTION FOUND LT AFT UPPER SURFACE OF KEEL BEAM FLANGE HAD WORN HOLES ON UPPER SURFACE FROM PANEL ATTACH NUTS AT STA 719-727. REPAIRED IAW ECRA 5310-03740.
- 2 Mar 2002
Web, worn
INSPECTION FOUND C-1 AFT DOOR JAMB LOWER WEB WORN AROUND EDGES. A NEW WEB WAS INSTALLED IAW SRM 51-70-13.
- 27 Feb 2002
Skin, worn
INSPECTION FOUND UPPER FUSELAGE SKIN WORN AT STA 867, RBL 6. A REPAIR WAS INSTALLED IAW SRM 53-00-01, FIGURE 214.
- 27 Feb 2002
Strap, corroded
INSPECTION FOUND FLOOR H-STRAP CORRODED AT STA 1022-1026, LBL 3. A NEW H-STRAP WAS INSTALLED IAW SRM 51-10-2 AND 51-30-3.
- 25 Feb 2002
Floor Support, cracked
INSPECTION FOUND A 1 INCH CRACK IN CABIN FLOOR SUPPORT AT STA 578, BBL 0. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-2.
- 25 Feb 2002
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED ABOVE AND BELOW NUT CLIP HOLES AT STA 986, RBL 46 TO LBL 46. THE FLOORBEAM WAS REPAIRED IAW ECRA 5310-03851.
- 24 Feb 2002
Floor Support, corroded
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 1006-1016, LBL 7 AND RBL 7. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-02-01.
- 24 Feb 2002
Skin, cracked
INSPECTION FOUND A 1/2" CRACK IN R/H WING #6 FLAP FAIRING LOWER SKIN WITH RIVETS PULLING THROUGH. A STIFFENER WAS INSTALLED IAW SRM 51-10-2.
- 24 Feb 2002
Collar, cracked
INSPECTION FOUND A .5 INCH CRACK IN RT WING NR 6 FLAP FAIRING HORSE COLLAR. A NEW COLLAR WAS INSTALLED IAW SRM 51-10-2.
- 23 Feb 2002
Floor Support, corroded
INSPECTION FOUND TWO FLOOR SUPPORTS CORRODED AT STA 986-1006. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02.
- 23 Feb 2002
Floor Support, corroded
INSPECTION FOUND A RT AND LT LAV FLOOR SUPPORT CORRODED AT STA 994, RBL 14 TO RBL 44, AND LBL 14 TO LBL 44. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW…
- 22 Feb 2002
Angle, corroded
INSPECTION FOUND Z-ANGLE CORRODED AT L-2 DOOR JAMB, STA 927. THE Z-ANGLE WAS REMOVED AND REPLACED IAW SRM 51-40-05.
- 22 Feb 2002
Floor Support, cracked
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT AT STA 663.75, LBL 65. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-02.
- 22 Feb 2002
Stringer, cracked
INSPECTION FOUND A 1" CRACK IN STRINGER 16L AFT OF STA 500C. REPAIRED STRINGER IAW SRM 53-00-03, FIGURE 201.
- 22 Feb 2002
Web, cracked
INSPECTION FOUND A 1/2" CRACK IN WEB AT STA 270, S14R. A WEB INTERCOSTAL WAS INSTALLED IAW SRM 51-10-02.
- 20 Feb 2002
Floor Support, cracked
INSPECTION FOUND A 2 INCH CRACK IN AC BAY FLOOR SUPPORT AT STA 559, RBL 24, IN FORWARD BAGGAGE BIN. THE SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-02.
- 18 Feb 2002
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AROUND NUT CLIP HOLES AT STA 1016, RBL 37 TO LBL 37. THE FLOORBEAM WAS REMOVED AND REPLACED IAW ECRA 5310-03851.
- 17 Feb 2002
Angle, cracked
INSPECTION FOUND A 3" CRACK IN ANGLE AT STA 927-947, BL 0. THE ANGLE WAS REMOVED AND REPLACED IAW SRM 51-30-03.
- 17 Feb 2002
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AROUND NUT CLIP HOLES AT STA 967, LBL 50 TO RBL 50 AND AT RBL 18 TO LBL 18. A REPAIR WAS INSTALLED IAW SRM 53-00-51,…
- 16 Feb 2002
Floor Support, corroded
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 947-967, LBL 18 AND RBL 18. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02 AND 51-40-02.
- 16 Feb 2002
Floor Support, corroded
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 967-986, LBL 18 AND RBL 18. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02.
- 16 Feb 2002
Floor Support, corroded
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 951, LBL 14 TO LBL 16 AND AT LBL 18 TO LBL 24. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02.
- 15 Feb 2002
Track, corroded
INSPECTION FOUND CABIN FLOOR R/H FORWARD GALLEY ATTACH TRACK CORRODED AT STA 280-294, RBL43. THE TRACK WAS REMOVED AND REPLACED IAW SRM 51-10-02.
- 12 Feb 2002
Floor Support, corroded
INSPECTION FOUND CABIN FLOOR SUPPORT CORRODED AT STA 328-344, LBL 12. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2.
- 12 Feb 2002
Floor Support, corroded
INSPECTION FOUND CABIN FLOOR SUPPORT CORRODED AT STA 294-312, LBL 12. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-70-12.
- 26 Sep 2000
Brake Assy, failed
BRAKES FAILED ON TAXI TO GATE. CHECKED BRAKE SYSTEM PER MAINTENANCE MANUAL 32-41-00 ADJ / TEST. ALL SYSTEMS CHECK NORMAL.
- 24 Nov 1998
Module, inop
THE FIRE WARNING LIGHT AND BELL ACTIVATED WHILE ON SHORT FINAL INTO EWR. THE WARNING WAS ON THE GLARESHIELD WITH NO INDICATIONS IN T-HANDLE ON THROTTLE…
- 24 Oct 1998
Fire Warning, activated
WHEN THE APU WAS STARTED ON DESCENT INTO SAT, THE APU FIRE WARNING LIGHT AND BELL ACTIVATED. THERE WERE NO LIGHTS IN APU FIRE HANDLE OR FOR ENGINES AND NO…
- 17 Mar 1998
Battery, discharged
THE FORWARD SERVICE DOOR EXIT SIGN FAILED TEN MINUTE BURN DURATION TEST. THE BATTERY WAS REPLACED AND A WIRE WAS RECONNECTED, OPERATIONAL TEST WAS GOOD.
- 7 Mar 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 344, RBL 5 TO LBL 40. THE FLOORBEAM WAS REPAIRED IAW SRM 53-10-51, FIGURE 205.
- 6 Mar 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 312 FROM LBL 20 TO RBL 20. A REPAIR ANGLE WAS INSTALLED IAW SRM 53-10-51, PAGE 220-223.
- 5 Mar 1998
Intercostal, corroded
INSPECTION FOUND INTERCOSTAL CORRODED BETWEEN FS 967 AND 986.5 LEFT SIDE, 22 INCHES FROM CENTERLINE. A NEW INTERCOSTAL WAS INSTALLED IAW SRM 51-10-2.
- 4 Mar 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT BOTH SIDES OF SCREW HOLES TO EDGE OF T-CAP AT STA 986.5. REPAIRED IAW SRM 53-00-51.
- 4 Mar 1998
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT BS 967 UPPER T-CAP, LBL24. REPAIRED IAW SRM 53-00-51, FIGURE 202.
- 28 Mar 1997
O-Ring, leaking
AIRCRAFT LOST B-SYSTEM HYDRAULIC FLUID AND PRESSURE ON APPROACH. THE LOSS WAS ACCOMPANIED BY ILLUMINATION OF THE HYDRAULIC PUMP LOW PRESSURE LIGHT.…