N14208
1934 Douglas DOLPHIN 12 FAA →
earlier registrations
2 past records
- 1934
service difficulty reports
12 reports
- 27 Apr 1998
Hyd Lines, punctured
THE A SYSTEM HYDRAULIC FLUID LEVEL DROPPED TO ZERO WHILE ON DESCENT INTO PHL. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND TWO HYDRAULIC FLEX LINES…
- 1 Dec 1997
Line, leaking
THE AIRCRAFT LOST A-HYDRAULIC SYSTEM WHILE EN ROUTE. THE AIRCRAFT WAS DIVERTED TO BUF WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE LEFT WING AFT…
- 22 Aug 1997
Pcu, inoperative
A/C ATTEMPTED TO BANK LT WITH YAW DAMPER ON AND AUTOPILOT ENGAGED WHILE CLIMBING THRU 17,000 FT. THE YAW DAMPER WAS SWITCHED OFF AND ROLL ARRESTED. BANK ANGLE…
- 7 Jun 1995
Uplock Sensor, inoperative
FLT NR 9860 - CLE - THE RT MLG RED UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. CYCLING THE GEAR DID NOT HELP. THE AIRCRAFT WAS RETURNED TO CLE…
- 10 May 1995
Frame, cracked
GSO - INSPECTION FOUND A .5 INCH CRACK IN FRAME BETWEEN S22L AND S23L AT STATION 460. THE CRACKED FRAME WAS REMOVED AND A NEW FRAME AND DOUBLERS WERE…
- 10 May 1995
Frame, cracked
GSO - INSPECTION FOUND A .75 INCH CRACK IN FRAME BETWEEN S20L AND S21L AT STATION 480. THE CRACKED SECTION OF FRAME WAS CUOTUT. A NEW SECTION OF FRAME WAS…
- 10 May 1995
Frame, cracked
GSO - INSPECTION FOUND A .5 INCH CRACK IN FRAME BETWEEN S20L AND S21L AT STATION 500. THE CRACKED SECTION OF FRAME WAS CUTOUT. A NEW SECTION OF FRAME WAS…
- 10 May 1995
Frame, cracked
GSO - INSPECTION FOUND A .5 INCH CRACK IN FRAME BETWEEN S20L AND S21L AT STATION 440. THE FRAME WAS REMOVED AND REPLACED IAW BOEING DRAWING NR 65C25113 AND EA…
- 10 May 1995
Frame, corroded
GSO - INSPECTION FOUND CORROSION ON FRAME ABOVE STRINGER 26R AT STATION 529. A NEW FRAME AND SPLICE WERE FABRICATED AND INSTALLED IAW SRM 53-10-3 AND 51-30-2.…
- 10 May 1995
Skin, cracked
GSO - INSPECTION FOUND A .5 INCH CRACK IN EXTERNAL SKIN AT STRINGER 4L, STATION 908. THE CRACKED AREA WAS CUTOUT. A FILLER AND DOUBLER REPAIR WAS FABRICATED…
- 10 May 1995
Skin, cracked
GSO - INSPECTION FOUND FUSELAGE SKIN FASTENER HOLES CRACKED IN SEVERAL LOCATIONS BETWEEN BS 188-251.6 RIGHT SIDE. THE CRACKS WERE APPROXIMATELY .25 INCH LONG.…
- 10 May 1995
Skin, cracked
GSO - INSPECTION FOUND FUSELAGE SKIN FASTENER HOLES CRACKED IN SEVERAL PLACES BETWEEN WL 207.5 AND 234.35, SECTION 41. THE CRACKS WERE APPROXIMATELY .25 INCH…