service difficulty reports
13 reports
- 21 Jun 2004
Pump, inoperative
STL - INFLIGHT T2041 ON CLIMBOUT L1 AND L2 FUEL PUMP LIGHTS CAME ON AND WENT OFF. LATER MAIN LEVELS BECAME INBALANCED. REPLACED L1 AND L2 BOOST PUMPS AND LEFT…
- 20 Nov 2003
Light, loose
ORD EMERGENCY FLOOR LIGHTING STRIP AT ROW 16 PULLED LOOSE. REPAIRED EMERGENCY FLOOR LIGHTING STRIP AT ROW 16. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 6 Feb 2003
Light, inoperative
DFW - FOUND DURING OVERNIGHT MAINTENANCE, NR 5 EMERGENCY EXIT AISLE LIGHT INOPERATIVE. REPLACED NR 5 EMERGENCY EXIT AISLE LIGHT. SYSTEM GROUND CHECKED NORMAL…
- 14 Nov 2002
Wire, damaged
DFW - DURING EMERGENCY, EXIT FLOOR PATH LIGHT STRIP AT SEAT 8D INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP WIRE. SYSTEM GROUND CHECKED NORMAL…
- 29 May 2002
Floorbeam, corroded
(FLOORBEAM) CORROSION ON TOP OF FLOORBEAM AT BL1127R FROM STA 4610 TO 4850. REPLACE TOP OF FLOOR SUPPORT WITH ANGLE PROCURED FROM AA STOCK.
- 28 May 2002
Floorbeam, corroded
CORROSION ON TOP OF FLOORBEAM STA 3845 TO 4610 BL1127LH. REPLACE CORROSION WITH NEW ANGLE PROCURED FROM AA STOCK.
- 17 Mar 2001
Connector, inoperative
ORD - DURING OVERNIGHT MAINTENANCE, COCKPIT EMERGENCY EXIT LIGHT INOPERATIVE. RE-SECURED COCKPIT EMERGENCY EXIT LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL…
- 21 Aug 2000
Circuit Breaker, tripped
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS DO NOT ILLUMINATE WHEN LANDING GEAR EXTENDED. RESET CIRCUIT BREAKER G-12. SYSTEM GROUND CHECK NORMAL…
- 13 Aug 2000
Light, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT IN CABIN INOPERATIVE. REPLACED DAMAGED SECTION OF LIGHT STRIP. SYSTEM GROUND CHECK NORMAL…
- 6 Apr 2000
Switch, failed
IAD - FLT 1365 - AFTER TAKEOFF DCA STAB TRIM 1 AND STAB 2 TRIM SWITCHES ON FLIGHT AUGMENTATION PANEL FAULTED. LANDED IAD WITHOUT INCIDENT. REPLACED STABILIZER…
- 7 Feb 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT 12B INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT SEAT 12B.…
- 2 Dec 1999
Flashlight, inoperative
ATL - DURING OVERNIGHT MAINTENANCE, FORWARD ENTRY EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED FORWARD ENTRY EMERGENCY FLASHLIGHT. SYSTEM GROUND CHECK NORMAL…
- 28 Jan 1998
Hyd Pump, defective
DFW - FLT 504 - DURING CLIMB-OUT FROM DFW, HYDRAULIC SYSTEM NR 1 INDICATED OVERHEAT CONDITION. CREW FOLLOWED ALTERNATE PROCEDURES TURNING OFF SYSTEM NR 1…