N14074
1934 Waco YMF FAA →
reservations
earlier registrations
2 past records
- 1974
- 1934
service difficulty reports
12 reports
- 17 Dec 1999
Liner, failed
THE NR 2 ENGINE FIRE WARNING LIGHT ILLUMINATED DURING CLIMBOUT. THE FIRE WARNING LIGHT WAS ACCOMPANIED BY EGT GOING FULL SCALE. THE ENGINE THROTTLE WAS…
- 4 Oct 1999
Batteries, discharged
INSPECTION FOUND TWO CABIN MEGAPHONES INOPERATIVE. THE MEGAPHONE BATTERIES WERE REMOVED AND REPLACED IAW MM 25-60-00.
- 3 Oct 1999
Light, inop
INSPECTION FOUND EMERGENCY ESCAPE LIGHT INOPERATIVE AT SEAT 3B IN PASSENGER CABIN. THE ESCAPE LIGHT ASSEMBLY WAS REMOVED AND REPLACED IAW MM 33-50-00.
- 13 Apr 1999
Spoiler, damaged
INSPECTION FOUND THE RT WING NR 2 SPOILER DAMAGED. THE NR 2 SPOILER WAS REMOVED AND REPLACED IAW MM 27-60-01, PAGE 401.
- 10 Dec 1998
Solenoid, failed
THE SMELL OF SMOKE WAS OBSERVED COMING FROM CAPTAIN'S SEAT DURING CRUISE PORTION OF FLIGHT. AN ELECTRICAL CONNECTION IN THE BASE OF SEAT BACK WAS FOUND HOT…
- 25 Jun 1997
Skin, dented
INSPECTION FOUND FUSELAGE SKIN DENTED AT STA 1119, LONGERON 40R. THE DENTED AREA WAS CUT OUT, A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-20-00, FIGURE 6.
- 25 Jun 1997
Intercostal, corroded
INSPECTION FOUND INTERCOSTAL CORRODED AT NR 1 PACK OUTLET, STA 555 TO 595. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-00-01, 53-12-01, FIGURE 12 AND…
- 19 Jun 1997
Skin, dented
INSPECTION FOUND A .5 INCH CRACK AND DENT IN SKIN AFT OF RADOME AT LBL 10. THE DAMAGED AREA WAS CUT OUT AND A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-00-01,…
- 15 Dec 1996
Battery, discharged
THE EMERGENCY LIGHTS WOULD NOT TEST. CHANGING BATTERY CHARGER AT OVERWING POSITION DID NOT HELP. THE BATTERY AT DOOR 3L WAS REPLACED AND THE EMERGENCY LIGHTS…
- 15 May 1996
Dnlock Actuator, failed
MAN - FLT 9891 - THE CENTER GEAR WARNING LIGHT REMAINED ILLUMINATED FOR 2 MINUTES AFTER GEAR HANDLE HAD BEEN PLACED IN THE 'UP' POSITION ON TAKEOFF FROM MAN.…
- 23 Apr 1996
Door Jamb, corroded
INSPECTION FOUND FORWARD CARGO DOOR JAMB LOWER EDGE CORRODED. THE DOOR JAMB WAS REPAIRED IAW SRM 53-50-00, FIGURE 1.
- 19 Mar 1996
Former, cracked
MAN - INSPECTION FOUND THE NR 1 ENGINE NOSE COWL FORWARD FORMER CRACKED FROM APPROXIMATELY THE 11 O'CLOCK TO 2 O'CLOCK POSITIONS ALONG INNER SEATING ANGLE.…