- 7 Jan 2003
Smoke, detected
EWR - FLT 867 - EN ROUTE EWR-ORD, SMOKE IN CABIN WITH A ELECTRICAL SMELL. CHECKED GALLEY EQUIPMENT AND LIGHTING. RETURNED EWR AND LANDED WITHOUT INCIDENT.…
- 18 Oct 2002
Starter, malfunctioned
ORD - FLT 1641 - EN ROUTE ORD-SAT, SMELLED SMOKE THROUGHOUT AIRPLANE ON TAKEOFF ROLL, CREW THOUGHT IT WAS FROM AIRPLANE CLOSE TO THEM THAT WAS IN FRONT. FUMES…
- 2 May 2002
Light, inoperative
(LIGHT ASSEMBLY) DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHTS, INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT ASSEMBLY. SYSTEM GROUND…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL LEFT WING AFT ESCAPE HATCH EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT LEFT WING AFT ESCAPE HATCH EXIT LIGHTS.…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL LEFT WING FORWARD ESCAPE HATCH EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT LEFT WING FORWARD ESCAPE HATCH EXIT…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL RIGHT WING FORWARD ESCAPE HATCH EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT RIGHT WING FORWARD ESCAPE HATCH…
- 23 Jul 2001
Light, burned out
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL RIGHT WING AFT ESCAPE HATCH EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT RIGHT WING AFT ESCAPE HATCH EXIT…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL MID CABIN CEILING MOUNTED EMERGENCY EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS IN MID CABIN CEILING MOUNTED…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL COCKPIT ENTRY EMERGENCY EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS IN COCKPIT ENTRY EMERGENCY EXIT LIGHTS.…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL FORWARD ENTRY DOOR EMERGENCY EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT FORWARD ENTRY DOOR EMERGENCY EXIT…
- 23 Jul 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, SEVERAL GALLEY DOOR EMERGENCY EXIT LIGHTS BURNED OUT. REPLACED FUSED LAMPS AT GALLEY DOOR EMERGENCY EXIT LIGHTS. SYSTEM…
- 19 Dec 2000
Apu, leaking
DFW - FLT 1196 - EN ROUTE DFW-CVG AT GATE, SHORTLY AFTER STARTING ENGINES, CABIN FILLED WITH SMOKE. SHUT DOWN ENGINES. REPLACED APU. SYSTEM UNDER…
- 22 Sep 2000
Connector, defective
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS FORWARD OF ROW 10 INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH TRACK LIGHTING FLAT…
- 3 Jul 2000
Wire, broken
DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS INOPERATIVE. REPAIRED EMERGENCY EXIT ESCAPE PATH LIGHT WIRING. SYSTEM GROUND CHECK NORMAL…
- 25 Jun 1999
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE BETWEEN SEAT ROWS 11 THROUGH 15. REPAIRED WIRING AS REQUIRED BETWEEN SEAT…
- 21 Feb 1998
Wire, failed
ORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS AT FORWARD SERVICE DOOR WERE INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT GROUND WIRE LOCATED OVER…
- 30 Oct 1995
Angle, cracked
TUL - LEFT OUTBOARD PROFILE ANGLE CRACKED OUTBOARD SIDE. INSTALLED DOUBLER PER ESO 51000 DATED 10-27-95. TST 8,673. CYCLES, 7,365. (X)
- 18 Aug 1995
Eel Wire, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT WIRING ON LOOSE CEILING PANEL BETWEEN FORWARD GALLEY BROKEN. REPAIRED EMERGENCY LIGHT WIRING. SYSTEM GROUND…
- 24 Mar 1995
Lock Pin, needed adjust
ORD-LIT - FLT 1061 - EN ROUTE, THE LT MLG MFDU WARNING INDICATION. CYCLED GEAR THREE TIMES DID NOT CLEAR MESSAGE. RETURNED ORD AND LANDED OVERWEIGHT WITHOUT…