    s/n 47866 engine Ge CF6-50 Ser

service difficulty reports

62 reports
  1. 8 Jun 2000

    Channel, cracked

    Doug DC1030

    THE FORWARD CARGO COMPARTMENT LEFT LOWER SIDEWALL Z-CHANNEL FORWARD OF LOAD BAR HAD A 12 INCH CRACK AND PUNCTURE ON LT LOWER SIDEWALL TRIM PLATE. AN INTERIM…

  2. 8 Jun 2000

    Web, cracked

    Doug DC1030

    INSPECTION FOUND A 3 INCH CRACK ON VERTICAL WEB IN AFT CARGO COMPARTMENT AT STA 1841 ABOVE LONGERON 43-44, LBL 65. THE CRACKED AREA WAS TRIMMED OUT AND…

  3. 7 Jun 2000

    Skin, cracked

    Doug DC1030

    INSPECTION FOUND A 6 INCH CRACK IN LT WING LOWER SURFACE ON I/B CORNER OF FUELING BAY DOOR CUTOUT. THE AREA WAS REINFORCED WITH A DOUBLER USING RIVETS IAW SRM…

  4. 7 Jun 2000

    Skin, corroded

    Doug DC1030

    INSPECTION FOUND EXTERNAL FUSELAGE SKIN CORRODED AT STA 900 BETWEEN LONGERON 37L AND 38L. THE CORRODED AREA OF SKIN WAS TRIMMED OUT. THE AREA WAS REINFORCED…

  5. 7 Jun 2000

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 1 INCH CRACK IN ANGLE ON OUTER DOOR CUTOUT AFT SIDE FORWARD EDGE, LT MLG WHEEL WELL. THE ANGLE WAS REMOVED AND A NEW ANGLE WAS INSTALLED…

  6. 7 Jun 2000

    Stringer, cracked

    Doug DC1030

    INSPECTION FOUND STRINGERS NR 4, 5, AND 7 CRACKED IN RT MAIN GEAR WHEEL WELL AT O/B LOWER WALL AFT OF OUTER DOOR CUTOUT. THE CRACKS WERE 1, 4, AND 5 INCHES…

  7. 7 Jun 2000

    Fitting, corroded

    Doug DC1030

    INSPECTION FOUND FORWARD CARGO DOOR JAMB FORWARD FITTING CORRODED. THE FITTING WAS REMOVED AND A NEW FITTING WAS INSTALLED IAW SRM 53-50-00, FIGURE 1,…

  8. 7 Jun 2000

    Intercostal, corroded

    Doug DC1030

    INSPECTION FOUND INTERCOSTAL CORRODED IN CENTER CARGO COMPARTMENT AT STA 1740, LONGERON 45R. THE CORRODED AREA WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM…

  9. 2 Jun 2000

    Light, inoperative

    Doug DC1030

    INSPECTION FOUND CABIN EMERGENCY LIGHT ASSEMBLY AT SEAT 9B INOPERATIVE. THE LIGHT ASSEMBLY WAS REPLACED AND OPERATION CHECKED GOOD IAW MM 33-50-00.

  10. 23 Dec 1999

    Oven, inoperative

    Doug DC1030

    SMOKE BEGAN COMING OUT OF THE AFT GALLEY OVEN CONTROL PANEL WHILE EN ROUTE TO EWR. THE SMOKE STOPPED WHEN OVEN WAS TURNED OFF. THE FLIGHT CONTINUED WITHOUT…

  11. 14 Nov 1999

    Wire, broken

    Doug DC1030

    INSPECTION FOUND FORWARD EMERGENCY LIGHT AT SEAT 2KL INOPERATIVE. INSPECTION REPAIRED BROKEN WIRE AT SEAT 2KL AND OPERATION CHECKED GOOD.

  12. 5 Jul 1999

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND TWO VERTICAL STIFFENER ANGLES ON LT WHEEL WELL AFT SIDE WEB CRACKED. THE CRACKS WERE .5 INCH LONG. THE TWO ANGLES WERE REMOVED AND NEW ANGLES…

  13. 5 Jul 1999

    Skin, cracked

    Doug DC1030

    INSPECTION FOUND A 1 INCH CRACK WITH SHEARED RIVETS IN RT WING NR 2 LEADING EDGE SLAT INBOARD SKIN. THE CRACKED AREA WAS TRIMMED OUT AND REINFORCED WITH…

  14. 5 Jul 1999

    Support, corroded

    Doug DC1030

    INSPECTION FOUND FLOOR SUPPORT CORRODED UNDER LAV/GALLEY FLOOR AREA AT STA 420 BETWEEN BL 0 TO LBL 27. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS…

  15. 5 Jul 1999

    Support, corroded

    Doug DC1030

    INSPECTION FOUND CABIN FLOOR SUPPORT CORRODED BETWEEN STA 1920 AND 2007, LBL 55. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-31-01.

  16. 5 Jul 1999

    Frame, cracked

    Doug DC1030

    INSPECTION FOUND A 2 INCH CRACK IN FRAME OF CENTER CARGO COMPARTMENT VERTICAL WALL AT STA 1841, RBL 20. THE CRACKED AREA WAS TRIMMED OUT AND REINFORCED WITH…

  17. 5 Jul 1999

    Liner, torn

    Doug DC1030

    INSPECTION FOUND A 2 INCH TEAR ON VERTICAL WALL IN CENTER CARGO COMPARTMENT AT STA 1841, RBL 10. THE TORN AREA WAS TRIMMED OUT AND REINFORCED WITH DOUBLER IAW…

  18. 5 Jul 1999

    Support, cracked

    Doug DC1030

    INSPECTION FOUND A 2 INCH CRACK IN FLOOR SUPPORT IN FORWARD CARGO AREA AT STA 755 BETWEEN RBL 65 AND 85. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS…

  19. 5 Jul 1999

    Support, cracked

    Doug DC1030

    INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT IN FORWARD CARGO AREA AT STA 899, RBL 45-65. THE FLOOR SUPPORT WAS REMOVED AND A NEW ONE WAS INSTALLED IAW…

  20. 5 Jul 1999

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 1 INCH CRACK IN FUSELAGE SKIN ATTACH ANGLE AT STA 1120, STRINGER 33-34R. THE ANGLE WAS REMOVED AND A NEW ANGLE WAS INSTALLED IAW SRM…

  21. 4 Jul 1999

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 1 INCH CRACK IN STIFFENER VERTICAL ANGLE AT RT MLG WHEEL WELL REAR BULKHEAD LOWER O/B CORNER JOINT TO LONGERON TO BULKHEAD. THE ANGLE WAS…

  22. 30 Jun 1999

    Stringer, corroded

    Doug DC1030

    INSPECTION FOUND FRAME CORRODED IN LOWER LOBE AFT CARGO BILGE AREA AT STA 1851 BETWEEN STRINGER 51L AND 51R WITH CORROSION ON STRINGERS 52L AND 51L. THE…

  23. 28 Jun 1999

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 2 INCH CRACK ON VERTICAL ANGLE IN CENTER CARGO COMPARTMENT AT STA 1841, LBL 10. THE ANGLE WAS REMOVED AND A NEW ANGLE WAS INSTALLED IAW SRM…

  24. 28 Jun 1999

    Wall, torn

    Doug DC1030

    INSPECTION FOUND TEARS ON VERTICAL WALL IN CENTER CARGO COMPARTMENT AT STA 1841 BETWEEN LBL 40 & 60. THE TORN AREAS WERE TRIMMED OUT AND DEBURRED. REINFORCED…

  25. 28 Jun 1999

    Frame, corroded

    Doug DC1030

    INSPECTION FOUND CORROSION ON BOTH LOWER SIDES OF FRAME AT STA 1741 AND 1761 BETWEEN STRINGER 47L AND 50R. THE CORRODED AREAS WERE REMOVED, NEW ANGLES WERE…

  26. 28 Jun 1999

    Stringer, corroded

    Doug DC1030

    INSPECTION FOUND STRINGER 50 CORRODED BETWEEN STA 1851 AND 1868. THE CORRODED SECTION WAS REMOVED, A NEW SECTION OF STRINGER WAS INSTALLED WITH REINFORCEMENT…

  27. 22 Jun 1999

    Support, corroded

    Doug DC1030

    INSPECTION FOUND FLOOR SUPPORT UNDER LAV/GALLEY AREA CORRODED AT STA 755-899, LBL 44. THE CORRODED FLOOR SUPPORT SECTION WAS REMOVED AND A NEW SECTION WAS…

  28. 11 Oct 1998

    Apu, leaking

    Doug DC1030

    OIL SMELL IN COCKPIT. APU INTERNAL OIL LEAK CONFIRMED. CLEANED AIRCRAFT PACKS. PLACARD APU PER MEL.

  29. 24 May 1998

    Computer, inoperative

    Doug DC1030

    THE CAPTAIN'S STICK SHAKER ACTIVATED, THE SLAT DISAGREE LIGHT ILLUMINATED, AND SLAT RESET ILLUMINATED DURING TAKEOFF FROM IAH. CONFIRMED SLAT RETRACTION PER…

  30. 7 May 1998

    Wire, broken

    Doug DC1030

    NUMBER 3 ENGINE NUMBER 1 AGENT FIRE BOTTLE LOW PRESSURE SWITCH FAILED. WIRE FOUND BROKEN AT EARTH POINT 6015D. WIRE RETERMINATED WITH A NEW TAG PER MM20-00-00.

  31. 6 May 1998

    Cartridge, open circuit

    Doug DC1030

    NUMBER 1 ENGINE FIRE BOTTLE AGENT ONE FILAMENT A NOT LIGHTING ON TEST BOX DURING TEST. CARTRIDGE FOUND U/S. INSTALLED NEW CARTRIDGE.

  32. 6 May 1998

    Fire Bottle, damaged

    Doug DC1030

    NUMBER 2 ENGINE AND APU FIRE BOTTLE LOW PRESSURE CONNECTOR P1-1264 SOCKET B FOUND PUSHED BACK. ELECTRICAL CONNECTOR REPLACED PER MM 20-00-00.

  33. 6 May 1998

    Wire, broken

    Doug DC1030

    CARGO FIRE BOTTLE NR 2 LOW PRESSURE SWITCH ELECTRICAL CONNECTOR WIRE FOUND BROKEN. WIRE W277B24 FOUND BROKEN AT PIN B OF CONECTOR P1-2189. NEW PIN FITTED AND…

  34. 3 May 1997

    Compressor, damaged

    Doug DC1030

    THE NR 3 ENGINE EXPERIENCED COMPRESSOR STALLS WHILE ENROUTE. THE AIRCRAFT WAS RETURNED TO LGW. THE NR 3 ENGINE WAS REMOVED AND REPLACED. THE ENGINE WAS RUN…

  35. 25 Apr 1997

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 2 CRACK IN FORMED ANGLE AT FUSELAGE SKIN, STA 1421, LONGERON 31L TO 32L, AT LT WING INBOARD TOP FILLET AREA. THE ANGLE WAS REMOVED. A…

  36. 25 Apr 1997

    Skin, dented

    Doug DC1030

    INSPECTION FOUND FIVE DENTS IN UPPER SKIN OF RT DETACHABLE ELEVATOR. THE DENTED SKIN WAS REMOVED IAW SRM 55-00-01, FIG. 1, VOL I AND 55-00-01, FIG. 2, VOL I.…

  37. 25 Apr 1997

    Shear Tie, corroded

    Doug DC1030

    INSPECTION FOUND FRAME SHEAR TIE CORRODED AT STA 1821, BETWEEN LONGERON 48L AND 49L. THE CORRODED SECTION OF SHEAR TIE WAS REMOVED AND A NEW SHEAR TIE WAS…

  38. 25 Apr 1997

    Shear Tie, corroded

    Doug DC1030

    INSPECTION FOUND FRAME SHEAR TIE CORRODED AT STA 1721, BETWEEN LONGERON 49L AND 47L. THE CORRODED SECTION OF SHEAR TIE WAS REMOVED AND A NEW SHEAR TIE SECTION…

  39. 25 Apr 1997

    Skin, buckled

    Doug DC1030

    INSPECTION FOUND FUSELAGE SKIN BUCKLED AT STA 335 JUST UNDER PILOT'S SLIDING WINDOW. THE AREA WAS REFORMED TO WITHIN LIMITS IAW SRM 53-20-00. A FINGER DOUBLER…

  40. 25 Apr 1997

    Angle, cracked

    Doug DC1030

    INSPECTION FOUND A 5.5 INCH CRACK IN LT WING INBOARD ATTACH ANGLE AT WS XCW 118. THE ANGLE WAS REMOVED IAW SRM 51-33-01. A NEW ANGLE WAS FABRICATED AND…

  41. 25 Apr 1997

    Panel, cracked

    Doug DC1030

    INSPECTION FOUND NR 3 ENGINE ACCESS PANEL 487 FRAME CRACKED AT ATTACHMENT HOLE, A BROKEN NUTPLATE, AND CORROSION AT MATING SURFACE. THE CRACK WAS 1 INCH LONG.…

  42. 25 Apr 1997

    Longeron, corroded

    Doug DC1030

    INSPECTION FOUND LONGERON 51R CORRODED AT STA 1708. THE CORRODED AREA WAS CUTOUT. A LONGERON AND SPLICE WERE FABRICATED AND INSTALLED IAW SRM 53-10-00, FIGURE…

  43. 25 Apr 1997

    Longeron, corroded

    Doug DC1030

    INSPECTION FOUND LONGERON 50L CORRODED AT BS 1708. THE CORRODED SECTION WAS CUTOUT. A LONGERON AND SPLICE WERE FABRICATED AND INSTALLED IAW SRM 53-10-00,…

  44. 25 Apr 1997

    Skin, corroded

    Doug DC1030

    INSPECTION FOUND FUSELAGE SKIN CORRODED BELOW CENTER PIT DOOR AT STA 1681-1701, L48L TO L48R. THE CORRODED AREA OF SKIN WAS CUT OUT IAW SRM 53-20-00. SKIN…

  45. 25 Apr 1997

    Skin, cracked

    Doug DC1030

    INSPECTION FOUND A 1 CRACK IN SKIN WITH CORROSION AT FASTENER ON RIGHT HAND SIDE OF NR 2 ENGINE COWL, STA 2120 UPPER SURFACE AT BASE OF VERTICAL STABILIZER.…

  46. 25 Apr 1997

    Longeron, corroded

    Doug DC1030

    DIP NR 017105 WAS COMPLIED WITH BY INSTALLING A PERMANENT REPAIR AT LONGERON 46L, STA 1811. THE OLD REPAIR WAS REMOVED. A PERMANENT REPAIR WAS FABRICATED AND…

  47. 3 Dec 1996

    Control Cable, broken

    Doug DC1030

    THE AIRCRAFT ARRIVED IN EWR WITH THE RT MLG DOOR HANGING DOWN. MAINTENANCE FOUND THE RT MLG DOOR FOLLOW-UP CABLE BROKEN. THE CABLE WAS REMOVED AND REPLACED…

  48. 28 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND LONGERON 30L CORRODED AT STATION 1436. THE LONGERON WAS REPAIRED IAW ECRA 5310-03218 AND SRM 53-14-01. (M)

  49. 28 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION ON LONGERON 31L AT STATION 1405. THE CORROSION WAS REMOVED AND A DOUBLE ANGLE REPAIR WAS INSTALLED IAW ECRA 5310-03217 AND…

  50. 26 Jan 1996

    Door Frame, cracked

    Doug DC1030

    KUL - INSPECTION FOUND TWO EACH 4 INCH CRACKS ON CENTER CARGO DOOR OUTER FRAME BY FORWARD LOWER STRIKER PLATE. THE CRACKS WERE REPAIRED IAW SRM 52-10-00,…

  51. 26 Jan 1996

    Stiffener, corroded

    Doug DC1030

    KUL - INSPECTION FOUND LATERAL STIFFENER CORRODED AT FS 1841 RBL 42 AND LBL 28. THE LATERAL STIFFENERS WERE REPLACED IAW SRM 53-16-01. (M)

  52. 24 Jan 1996

    Floor Beam, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION ON FLOOR BEAM AT STATION 1701. REPAIRED IAW ECRA 5310-03225. (M)

  53. 22 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION ON BOTH SIDES OF LONGERON 46L AT STATION 1811. REPAIRED IAW ECRA 5310-03221. (M)

  54. 22 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN LONGERON SPLICE 37R AT STATION 1536 AND 1545. REPAIRED IAW ECRA 5310-03223. (M)

  55. 22 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN LONGERON SPLICE 32R AT STATION 1561. REPAIRED PER ECRA 5310-03222. (M0

  56. 18 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN THE FLANGE OF LONGERON 37L AT STATION 1406. REPAIRED IAW ECRA 5310-03217. (M)

  57. 18 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN RIGHT FLANGE OF LONGERON 30L AT STATION 1412. REPAIRED IAW ECRA 5310-03219. (M)

  58. 17 Jan 1996

    Frame, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CAP CORRODED AT FRAME, STATION 1841 BETWEEN LONGERONS 50L AND 51R. THE AREA WAS REPAIRED IAW ECRA 5310-03214. (M)

  59. 17 Jan 1996

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN FLANGE OF LONGERON 32L AT STATION 1409. REPAIRED IAW ECRA 5310-03215. (M)

  60. 17 Jan 1996

    Fairing, corroded

    Doug DC1030

    KUL - INSPECTION FOUND CORROSION IN SKIN AND DOUBLER OF THE RIGHT PANEL ASSEMBLY OF RIGHT WING INBOARD FLAP OUTER HINGE FAIRING. REPAIRED IAW ECRA 5752-01017.…

  61. 29 Dec 1995

    Longeron, corroded

    Doug DC1030

    KUL - INSPECTION FOUND LONGERON 37R SPLICE CORRODED AT STATION 1536 AND 1545. THE AREA WAS REPAIRED IAW ECRA 5310-03223. (M)

  62. 25 Nov 1995

    Rubber Duct, blown

    Doug DC1030

    GUM - FLT 0900 - THE SYSTEM NR 1 AND NR 2 MANIFOLD FAIL LIGHTS ILLUMINATED IN FLIGHT WITH NR 2 DISPLAYING THE LOWEST PRESSURE. THE AIRCRAFT WAS RETURNED TO…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05223 Nov 2026
FCC GMRS633,26623 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,80320 Nov 2026
FAA registered aircraft319,53720 Nov 2026
FAA N-number reservations125,98920 Nov 2026
FAA dealers12,50720 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,08023 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.