N125HQ
2007 Embraer-Empresa Brasileira De ERJ 170-200 LR standard FAA →
registration
- 2007
service difficulty reports
90 reports
- 26 Mar 2026
Sensor, failed
LANDING GEAR WILL NOT RETRACT, HANDLE STUCK IN DOWN POSITION. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. REMOVED AND REPLACED STEERING SENSOR AND HARNESS.
- 11 Jul 2025
Windshield, cracked
FO WINDSHIELD SHATTERED IN DESCENT. EICAS MSG OF WINDSHIELD HEAT FAIL. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. REMOVED AND REPLACED RH WINDSHIELD.
- 28 Sep 2024
Shear Tie, corroded
DURING HEAVY CHECK MAINTENANCE FOUND SHEAR CLIP CORRODED NEXT TO WASTE BOX CUT OUT ON FR 88 STR 29R -26R. REMOVED AND REPLACED SHEAR CLIP ON WASTE BOX CUTOUT…
- 24 Sep 2024
Doubler, corroded
DURING HEAVY CHECK MAINTENANCE FOUND LAV WASTE SERVICE DOOR CUTOUT FLANGE CORRODED AT FR 88 AND STR 27R - 28R. REMOVED AND REPLACED LAV WASTE SERVICE CUTOUT…
- 23 Sep 2024
Blanket, punctured
DURING HEAVY CHECK MAINTENANCE FOUND RH ENGINE OB T/R MIDDLE THERMAL BLANKET PUNCTURED AND CHAFE PLATE CHAFED. REMOVED DAMAGED CHAFE PLATE AND SPOT WELDED NEW…
- 27 Aug 2024
Plate, chafed
#1 ENGINE IB TR CENTER THERMAL BLANKET CHAFE PLATE CHAFED. REMOVED DAMAGED CHAFE PLATE FROM #1 ENGINE IB TR CENTER THERMAL BLANKET AND FABRICATED REPAIR PATCH…
- 7 Feb 2024
Battery, no test
EMERGENCY LIGHT BATTERY #4 FAILED FUNCTIONAL CHECK. R&R #4 EMERGENCY BATTERY.
- 10 Dec 2021
Fitting, worn
RH HORIZONTAL STABILIZER BEARING FITTING DAMAGED ON I/B SIDE AROUND ENTIRE CIRCUMFERENCE. PERFORMED A PERMANENT REPAIR ON RH HORIZONTAL STABILIZER BEARING…
- 10 Dec 2021
Fitting, worn
LH HORIZONTAL STABILIZER BEARING FITTING DAMAGED ON I/B SIDE AROUND ENTIRE CIRCUMFERENCE. : PERFORMED TEMPORARY REPAIR ON LH HORIZONTAL STABILIZER BEARING…
- 10 Dec 2021
Skin, damaged
PIN HOLE ON UPPER SKIN OF RH HORIZONTAL STABILIZER AT REAR SPAR BETWEEN RIBS 10 AND 11. : REMOVED PIN HOLE DAMAGE ON UPPER SKIN OF RH HORIZONTAL STABILIZER AT…
- 4 Dec 2021
Shear Tie, corroded
CORRODED SHEAR CLIP AT FRAME 89, STGR 28R - 27R. REMOVED SHEAR CLIP AT FR89, STGR 28R - 27R REF SRM 51-40-08. DRILLED NEW SHEAR CLIP AT FRAME 89, STR 28R-27R…
- 4 Dec 2021
Actuator, inoperative
L2 DOOR PNEUMATIC ASSY FAILS TO ACTUATE IN EMERGENCY CONFIGURATION OPENING: ADJUSTED CONTROL PLATE OF L2 DOOR TO ALIGN RED MARKS AND SECURED KNURLED NUT WITH…
- 3 Dec 2021
Cable, abnormal
EMERGENCY LANDING GEAR EXTENSION MAIN CLOSED LOOP AND RETURN CLOSED LOOP CABLE TENSIONS OUT OF ADJUSTMENT. ADJUSTED THE CABLE TENSION ON THE EMERGENCY LANDING…
- 2 Dec 2021
Stringer, corroded
CORROSION ON STRINGER 28R IN AFT CARGO BETWEEN FRAMES 82/83 PERFORMED PERMANENT REPAIR BY CUTOUT AND INSTALLING FILLER AND SPLICE AT STRINGER 28R IN AFT CARGO…
- 17 Nov 2021
Heat Exchanger, smoke
SMELL OF SMOKE IN ROW 4, RETURNED TO GATE. R&R DUAL HEAT EXCHANGER ON PACK 2.
- 16 Nov 2021
Acm, smoke
PACK 2 FAIL FOLLOWED BY SMOKE IN CABIN. R&R PACK 2 ACM.
- 9 Nov 2021
Skin, punctured
FOUND PUNCTURE TO AIRCRAFT SKIN LH SIDE AFT OF L1 DOOR BETWEEN FR 20 TO FR 23 STR 14L TO 15L. REPAIRED IAW SRM 51-23-04 AND 53-10-01
- 7 Jul 2021
Slide, partial deploy
L1 DOOR SLIDE PARTIALLY HANGING OUT, GIRT BAR STILL ATTACHED WITH DOOR PARTIALLY OPEN. R&R L1 DOOR EVAC SLIDE IAW AMM 25-65-01.
- 15 Oct 2020
Slide, partial deploy
PARTIALLY BLEW SLIDE WHEN OPENING L1 DOOR. R & R L1 EMERGENCY EVACUATION SLIDE ASSEMBLY.
- 10 Sep 2020
Power Supply, inoperative
EMERGENCY LIGHT CENTER AFT AISLE EMERGENCY EXIT ABOVE L2 DOOR INOP. R&R EMERGENCY LIGHT POWER UNIT NR 3, IAW AMM 33-50-01.
- 5 Nov 2019
Access Door, corroded
WHILE IN HEAVY CHECK - CORROSION, INT. SIDE OF WASTE SERVICE DOOR AND EXT. AT HINGE. REMOVED AND REPLACED WASTE SERVICE DOOR
- 5 Nov 2019
Floor Splice, corroded
WHILE IN HEAVY CHECK - CORROSION AFT WET AREA R/H SPLICE BENT AND 1 EA. RIVET PULLED THRU AT FR. 90 AS MARKED. REPLACED SPLICE WITH NEW AND TOP-COATED REF.…
- 5 Nov 2019
Seat Track, corroded
WHILE DURING HEAVY CHECK - CORROSION L/H I/B SEAT TRACK FR. 23 - 34/43. CUT OUT DAMAGE SECTION ON L/H I/B SEAT TRACK AT FR. 30/31 TO FR. 34 AND C/W SPLICE…
- 5 Nov 2019
Seat Track, corroded
WHILE IN HEAVY CHECK - CORROSION, L/H I/B SEAT TRACK FR. 74-84. REPLACED L/H I./B SEAT TRACK FR. 74-84 WITH NEW, TOP-COATED AND APPLIED CIC REF, SRM…
- 5 Nov 2019
Seat Track, corroded
WHILE IN HEAVY CHECK - CORROSION / GOUGED, R/H I/B SEAT TRACK FR. 23 - 34/43. CUTOUT DAMAGE SECTION OF SEAT TRACK AND PERFORMED SPLICE REPAIR REF EMB ETD…
- 5 Nov 2019
Seat Track, corroded
WHILE DURING HEAVY CHECK - CORROSION, R/H I/B SEAT TRACK FR. 74-84. CUT R/H I/B SEAT TRACK BETWEEN FR. 80-81AND REMOVED SECTION TO FR. 84, C/W SPLICE REPAIR,…
- 5 Nov 2019
Shear Tie, corroded
WHILE IN HEAVY CHECK - MAJOR- AFT CARGO SHEAR CLIP HAS CORROSION BETWEEN FR82-FR83 AND STR28R-STR27R AS MARKED. REMOVED AND REPLACE SHEAR CLIP PER EMB SRM…
- 26 Nov 2018
Slide, detached
R1 SLIDE WON'T DISARM. R&R R1 DOOR EMERGENCY EVACUATION SLIDE IAW 25-65-01.
- 19 Oct 2017
Floor Support, corroded
FWD WET AREA RT FLOOR SUPPORT HAS CORROSION BETWEEN FRAMES 17 AND 18. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-41-02, AND SRM 51-43-02.
- 19 Oct 2017
Rib, cracked
MAJOR REPAIR. CRACKED RIB 12 ON LT HORIZONTAL STABILIZER BETWEEN FRONT SPAR AND MID SPAR. REMOVED AND REPLACED LT HORIZONTAL STABILIZER RIB 12 BETWEEN FRONT…
- 19 Oct 2017
Rib, cracked
MAJOR REPAIR FCBS 55-10-00-005, CRACKED RIBS ON RT HORIZONTAL STABILIZER BETWEEN FRONT SPAR AND MID SPAR. REMOVED AND REPLACED RIB 11 AND 12 ON RT HORIZONTAL…
- 18 Oct 2017
Seat Track, corroded
LEFT OTBD SEAT TRACK HAD AN AREA OF CORROSION AT FRAME 79. BLENDED THE DAMAGE AND FOUND OUT OF LIMITS IAW SRM 53-23-10. REMOVED AND REPLACED THE SEAT TRACK…
- 18 Oct 2017
Gusset, corroded
CENTER GUSSET CORRODED AT FRAME 90. REMOVED AND REPLACED THE GUSSET IAW SRM 51-43-03, AND 51-21-01.
- 18 Oct 2017
Support, corroded
LEFT PANEL SUPPORT IS CORRODED AT FRAME 86. REMOVED AND REPLACED THE SUPPORT BRACKET IAW SRM 51-40-08 AND 51-40-01.
- 17 Oct 2017
Support, corroded
TRIM SUPPORTS AT AFT CARGO LOWER BEAM CORRODED. BLENDED 2QTY TRIM SUPPORTS NDT CHECKED GOOD AND REMOVED AND REPLACED OUT OF LIMITS (3) AFT CARGO LOWER TRIM…
- 17 Oct 2017
Support, corroded
FWD CARGO TRIM SUPPORTS AT LOWER BEAM CORRODED. BLENDED CORROSION AND FOUND TO BE NON SIGNIFICANT DAMAGE. REMOVED AND REPLACED FWD CARGO TRIM SUPPORT (B),…
- 17 Oct 2017
Finger Doubler, corroded
CORROSION-AFT CARGO DOOR AFT FINGER DOUBLER. BLENDED CORROSION ON THE AFT CARGO FWD FINGER DOUBLER NOM 0.098" REM. 0.065". OUT OF ALLOWABLE LIMITS. REMOVED,…
- 17 Oct 2017
Finger Doubler, corroded
CORROSION AFT CARGO DOOR FWD FINGER DOUBLER. BLENDED CORROSION ON THE AFT CARGO FWD FINGER DOUBLER NOM 0.098" REM. 0.074". OUT OF ALLOWABLE LIMITS. REMOVED,…
- 17 Oct 2017
Closeout Panel, corroded
FWD CARGO LOWER BEAM CLOSE-OUT PANEL CORRODED. REMOVED AND REPLACED FORWARD CARGO LOWER BEAM CLOSE-OUT PANEL REF SRM 51-40-02, 51-23-04, 51-23-05, 51-23-06.…
- 17 Oct 2017
Closeout Panel, corroded
CORROSION AFT CARGO DOOR LOWER BEAM CLOSEOUT PANEL. REMOVED AND REPLACED AFT CARGO DOOR LOWER BEAM CLOSEOUT PANEL. REF AMM 20-10-01. APPLIED TOPCOAT REF SRM…
- 10 Oct 2017
Beam, corroded
L1 LOWER DOOR BEAM HAS CORROSION AT AFT GIRT BAR MOUNTING ATTACHMENT. BLENDED CORROSION FROM L1 LOWER DOOR BEAM, GREATER THAN 30% LOSS. OUT OF LIMITS REF SRM…
- 15 Feb 2017
Slide, unserviceable
CREW REPORTED THAT THE L2 DOOR SLIDE PRESSURE WAS IN THE RED. AIRCRAFT WAS FLOWN VIA MAINTENANCE FERRY FROM SYR TO PIT WHERE MAINTENANCE REMOVED AND REPLACED…
- 30 Jan 2017
Battery Pack, inoperative
CREW REPORTED THAT TWO OVERHEAD CABIN EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK IAW AMM AND OPS CHECKED GOOD.
- 21 Jan 2017
Proximity Sensor, malfunctioned
CREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED PROXIMITY SENSOR AND RIG…
- 19 Jan 2017
Sensor, out of adjust
CREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE ADJUSTED L2 DOOR CLOSED SENSOR IAW AMM AND…
- 2 Jan 2017
Sensor, out of adjust
CREW RECEIVED A MESSAGE THAT THE L2 DOOR WAS OPEN. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE ADJUSTED DOOR CLOSED SENSOR IAW…
- 24 Dec 2016
Warning Message, false activation
CREW REPORTED THAT THE L2 DOOR SHOWED OPEN ON THE EICAS DURING TURBULENCE. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE…
- 6 Dec 2016
Proximity Sensor, malfunctioned
CREW RECEIVED AN L2 DOOR OPEN INDICATION. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED L2 DOOR PROXIMITY…
- 29 Nov 2016
Light, malfunctioned
CREW REPORTED THAT THE EMERGENCY LIGHT WAS STUCK ON. CREW CYCLED EMERGENCY CALL BUTTONS ON BOTH AUDIO PANELS IAW AMM AND OPS CHECKED GOOD.
- 23 Dec 2015
Spar, damaged
DURING HEAVY CHECK LT WING SPAR 3 FWD FACE CHAFED BY HYDRAULIC LINE SYSTEM 1 LINE BULKHEAD FITTING. MX REPAIRED BY FABRICATION OF BUSHING AND REPAIR WASHERS…
- 22 Dec 2015
Beam, corroded
DURING HEAVY CHECK FWD CARGO DOOR CUTOUT LOWER BEAM IS CORRODED. MAINTENANCE R & R FWD CARGO DOOR CUTOUT LOWER BEAM IAW SRM 51-40-02, 51-23-04, 51-43-01,…
- 22 Dec 2015
Shear Tie, corroded
DURING HEAVY CHECK, AFT CARGO BAY FRAME 82, STRINGERS 26-27R SHEAR CLIP IS CORRODED. MAINTENANCE R & R THE SHEAR TIE IAW SRM 51-40-02, 51-41-01.
- 21 Dec 2015
Seal Rest, corroded
DURING HEAVY CHECK, AFT CARGO DOOR MIDDLE SEAL REST IS CORRODED. MAINTENANCE R & R THE SEAL REST IAW SRM 51-41-01.
- 14 Aug 2015
Fmu, failed
ABOUT 3 MILES FROM LANDING, CREW REPORTED THE NR 1 ENGINE FAILED. CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. AFTER BEING CHECKED OUT BY THE FIRE…
- 5 Jan 2015
Battery Pack, inoperative
CREW REPORTED THAT THE EMERGENCY SIGN WAS INOPERATIVE. MAINTENANCE R & R THE BATTERY PACK IAW AMM AND OPS CHECKED GOOD.
- 25 Aug 2014
Sensor, failed
CREW REPORTED A FLAP FAIL MESSAGE, ON APPROACH SLATS OPERATED, HOWEVER, FLAPS DID NOT. CREW DECLARED AN EMERGENCY AND REQUESTED EMERGENCY EQUIPMENT BE…
- 21 Apr 2014
Attach Fitting, broken
CREW REPORTED THAT THE R2 DOOR WOULD NOT DISARM. MAINTENANCE INSPECTED AND FOUND THE GIRT BAR ATTACH POINT PLATE SCREWS ON THE FLOOR WERE BROKEN CAUSING THE…
- 30 Dec 2013
Seal Depressor, corroded
DURING HEAVY CHECK, R2 DOOR LOWER CENTER SEAL REST CORRODED. MAINTENANCE R & R R1 DOOR LOWER CENTER SEAL REST IAW SRM 51-40-02, 51-10-03, 51-41-03. PN…
- 29 Dec 2013
Skin, dented
DURING HEAVY CHECK, A SMALL DENT WAS FOUND IN THE SKIN FWD OF MAIN CABIN DOOR, BELOW JUST AFT OF 175 LOGO. MAINTENANCE CLASSIFIED AS A MAJOR REPAIR DO TO…
- 29 Dec 2013
Sill, corroded
DURING HEAVY CHECK, R2 DOOR SILL HAS CORROSION AFT OF GIRT BAR FIXTURE. MAINTENANCE R & R R2 DOOR SILL IAW SRM 170/175, SRM 51-43-01, & 51-43-02.
- 28 Dec 2013
Rib, cracked
DURING HEAVY CHECK, RT HORIZONTAL STAB L/E RIB 4 CRACKED. MX CUT OUT DAMAGED AREA, FABRICATED REPAIR ANGLE, FABRICATED FILLER IAW ETD 2013-170-071192, REV D.…
- 27 Dec 2013
Doubler, corroded
DURING HEAVY CHECK, LAVATORY SERVICE BOX DOUBLER CORRODED. MX R & R CORRODED DOUBLERS, AND COMPLETED SB 170-53-0095.
- 26 Dec 2013
Dampener, corroded
DURING HEAVY CHECK, R1 DOOR DAMPENER HAS CORROSION. MX R & R DOOR DAMPENER IAW AMM 52-41-27.
- 25 Dec 2013
Bulkhead, cracked
DURING HEAVY CHECK, LEFT FWD MLG WHEEL WELL BULKHEAD COMPOSITE PANEL IS CRACKED. MAINTENANCE R & R COMPOSITE PANEL IAW SRM 51-42-01.
- 24 Dec 2013
Pan, cracked
DURING HEAVY CHECK, FOUND SEAT PANS CRACKED. R & R SEAT PANS IAW AMM 25-21-17,
- 21 Nov 2013
Warning Message, false activation
CREW RECEIVED A STEER FAIL MESSAGE UPON EXTENSION OF LANDING GEAR. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT, HOWEVER THE ACFT HAD TO BE…
- 3 May 2013
Cable, broken
CREW REPORTED THAT THE R2 DOOR IS HARD TO CLOSE. MAINTENANCE FOUND THE R2 DOOR GIRT BAR CABLE IS BROKEN. AIRCRAFT WAS FLOWN VIA MAINTENANCE FERRY TO CMH WHERE…
- 23 Feb 2012
Mount Bolt, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE L-2 DOOR EMERGENCY SLIDE FORWARD LOWER MOUNT BOLT. MAINTENANCE REMOVED AND REPLACED…
- 23 Feb 2012
Shear Plate, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LEFT SHEAR PLATE AT FRAME 87. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE AND…
- 23 Feb 2012
Shear Plate, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LEFT SHEAR PLATE AT FRAME 87. MAINTENANCE REMOVED AND REPLACED THE SHEAR PLATE AND…
- 23 Feb 2012
Seat Track, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LT SEAT TRACK BEAM FORWARD OF FRAME 86. MAINTENANCE REMOVED AND REPLACED THE LT SEAT…
- 23 Feb 2012
Support Angle, cracked
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK MAINTENANCE FOUND THE LEFT WHEEL WELL FORWARD BULKHEAD UPPER SUPPORT ANGLE CRACKED. MAINTENANCE REMOVED AND REPLACED…
- 22 Feb 2012
Doubler, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LAV WASTE BOX, FORWARD INTERNAL DOUBLER. MAINTENANCE REMOVED AND INSTALLED NEW…
- 22 Feb 2012
Seat Track, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE SEAT TRACK BEAM AFT OF FRAME 86. MAINTENANCE REMOVED AND REPLACED THE SEAT TRACK…
- 22 Feb 2012
Shear Web, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE CENTER SHEAR WEB AT FRAME 87-88. MAINTENANCE REMOVED AND REPLACED THE CENTER SHEAR…
- 21 Feb 2012
Shear Web, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE RT SHEAR WEB IN THE AFT WET AREA BETWEEN FRAMES 86 & 87. MAINTENANCE REMOVED AND…
- 20 Feb 2012
Intercostal, corroded
ACFT IN HEAVY CHECK, FOUND RIGHT INTERCOSTAL FROM FR 89 TO 90 CORRODED. MX REMOVED AND REPLACED RIGHT INTERCOSTAL IAW SRM 51-41-01, 51-41-02, 51-43-03,…
- 20 Feb 2012
Crossbeam, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE FLOOR CROSS BEAM 17, ON THE RT SIDE OF THE BEAM. MAINTENANCE REMOVED AND REPLACED…
- 19 Feb 2012
Floor Support, corroded
ACFT IN FOR HEAVY CHECK, CORROSION FOUND ON FLOOR STRUCTURE PLATES UNDER FLOORBOARD 252ERF. MX REMOVED AND REPLACED CORRODED GUSSET IAW SRM 51-41-02.
- 19 Feb 2012
Floor Support, corroded
ACFT IN HEAVY CHECK, CORROSION FOUND ON FLOOR STRUCTURE UNDER FLOORBOARD 252ERF. MX REMOVED AND REPLACED CORRODED GUSSET IAW SRM 51-41-02.
- 19 Feb 2012
Seat Track, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE FLOORBOARD STRUCTURE (SEAT TRACK) UNDER FLOORBOARD PANEL 226BRF. MAINTENANCE REMOVED…
- 18 Feb 2012
Screw, corroded
DURING HEAVY CHECK, FOUND RIGHT WING NR 1 SLAT LOWER SEALS WORN AND HARDWARE IS RUSTED. MX REMOVED AND REPLACED THE RIGHT WING NR 1 SLAT LOWER SEALS AND…
- 18 Feb 2012
Hinge, corroded
WHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LAV SERVICE DOOR HINGE. MAINTENANCE REMOVED AND REPLACED THE LAV SERVICE DOOR HALF…
- 6 Jan 2011
Sensor, faulty
CREW REPORTED SLAT FAIL MESSAGE ON APPROACH, CREW DID NOT DECLARE AN EMERGENCY BUT EMERGENCY VEHICLES WERE ROLLED. AC LANDED WITHOUT INCIDENT. MX CLEARED…
- 4 Jan 2011
Unknown, malfunctioned
CREW REPORTED SLAT FAIL ON APPROACH AND DECLARED EMERGENCY, CABIN WAS NOT PREPARED. A/C LANDED WITHOUT INCIDENT, MX RESET PER FIM, MESSAGE CLEARED OPS CHECK…
- 9 Mar 2010
Slide, cracked
WHILE IN HEAVY CHECK, CREW REPORTED L-1 DOOR EVAC SLIDE HAD A CRACK IN THE COMPOSITE NUT PLATE. MAINTENANCE REMOVED AND REPLACED THE L-1 EVAC SLIDE PER EMB AMM.
- 9 Nov 2009
Battery, discharged
MTX REPORTED DURING FUNCTIONAL CHECK OF EMERGENCY LIGHTS, SEVERAL EMERGENCY LIGHTS WEREN'T ILLUMINATING. ONE LIGHT WAS AN EXIT SIGN, AND ONE WAS A COURTESY…
- 19 Jan 2009
Sensor, failed
ON CLIMBOUT CREW REPORTED, THEY RECEIVED SLAT/FLAP FAIL MESSAGE ON EICAS. CREW DECLARED EMERGENCY FOLLOWED QRH PROCEDURES AND RETURNED TO FIELD WITHOUT…
- 27 Dec 2008
Rod, broken
CREW REPORTED AFTER GEAR WAS RETRACTED AND HAD 3 GREEN, STILL HAD A NOSE GEAR DOOR OPEN. CYCLED GEAR AND STILL HAD MESSAGE. FOLLOWED QRH PROCEDURES, LANDED…
- 21 May 2008
Flap, malfunctioned
CREW REPORTED FLAP FAIL MESSAGE ON EICAS DURING DESCENT. CREW DECLARED EMERGENCY FOLLOWED QRH PROCEDURE AND LANDED WITHOUT INCIDENT. MAINTENANCE WAS…