N117DL
1980 Bell Helicopter Textron 212 standard FAA →
reservations
earlier registrations
1 past record
- 1980
NTSB
- 26 Jan 1988
accident, Block Island RI
service difficulty reports
35 reports
- 15 May 2004
Link, corroded
NR 2 LEFT I/B TRAILING EDGE FLAP I/B TORQUE TUBE LOWER ATTACH LINK CORRODED IN AFT O/B HOLE. COMPLIED WITH ERA089397-14MA REV A TIME LIMITED REPAIR NR 5.
- 9 Apr 2004
O-Ring, damaged
LOSS OF CENTER HYD FLUID. FOUND O-RING ON RUDDER PCA DAMAGED. REPLACED O-RING.
- 9 Apr 2004
Light, sparks
FLIGHT ATTENDANT REPORTED BURNING EMBER FELL OUT OF OVERHEAD AREA IN MID GALLEY. MTC PULLED CEILING PNLS DOWN IN MID GALLEY AREA. INSPECTED LIGHTING FIXTURES…
- 7 May 2002
Engine, failed
ENGINE STALLED ON TAKEOFF WITH EGT EXCEEDING REDLINE. NR 2 ENG REPLACED.
- 12 Dec 2001
Duct, cracked
NR 5 LEADING EDGE SLAT HAD A ANTI-ICE DUCT MALFUNCTION, IN WHERE THE FORWARD DUCT WAS CRACKED AND DAMAGED. SLAT WAS REPAIRED PER ERA 410858-14 REV 0 (REF CMM…
- 17 Mar 2001
Slat, malfunctioned
LEADING EDGE ASSYM EICAS MESSAGE CAME ON WITH LEADING EDGE LIGHT AT 250 KTS. FLAP INDICATION SHOWED HALFWAY BETWEEN UP AND 1 DEG. WITH WING A/I ON. LOWERED…
- 8 Sep 2000
Computer, malfunctioned
ON TAKEOFF ROTATION FIRE WARNING BELL CAME ON, NO LIGHT OR EICAS INDICATIONS. BELL COULD NOT BE SILENCED. T/SYSTEM BY PULLING B WARNING ELEX C/B HORN WAS…
- 12 Aug 2000
Engine, leaking
FULL PWR TAKEOFF RIGHT AFTER LIFTOFF SMOKE FILLED THE ENTIRE AFT CABIN C ZONE AND SET OFF THE LAV SMOKE DETECTORS. NO SOURCE COULD BE IDENTIFIED. LAVS AND…
- 12 Aug 2000
Engine, odor
FULL POWER T/O, GOT STRONG ACRID SMELL IN THE MID AND AFT CABIN RIGHT AFTER LIFTOFF. SMELL WENT AWAY RAPIDLY WHEN CLIMB POWER WAS SELECTED. NO SMOKE OBSERVED.…
- 11 Aug 2000
Engine, leaking
STRONG SMELL IN A/C PACKS T/O MADE AFT SMOKE DET GO OFF BRIEFLY, NO SMOKE. CLEARED UP A FEW MINS LATER. REPLACED NR 2 ENGINE FOR OIL LEAK.
- 1 Aug 2000
Fan, malfunctioned
F/A REPORTED ELEC SMELL AND HAZE IN CABIN AND 2 LAV SMOKE ALARMS WERE HEARD. TURNED OFF RECIRC FANS, ALARMS STOPPED AND HAZE CLEARED. INSPECTED FWD E/E MID…
- 5 May 2000
Battery Pack, discharged
EMERGENCY LIGHTS AFT OF LT WING INOP. RELAMPED, NO HELP. REPLACED BATTERY PACK, OPS CHECK GOOD.
- 19 Apr 2000
Engine, odor
ON TAKEOFF, F/A CALLED AND REPORTED SMOKE AND FUMES IN THE CABIN. RETURNED FOR LANDING. F/A THEN REPORTED ONLY FUMES. PRIOR TO LANDING FUMES HAD DISAPPEARED.…
- 21 Oct 1999
Skin, damaged
SKIN AT STA 370 AND STR 34R HAS A GASH MEASURING APPROX 6 X 3. ALSO, STRINGER 34R DAMAGED AT THIS LOCATION. BOTH SKIN AND STRINGER ARE BEING REPAIRED ER/A…
- 15 Oct 1999
Chord, corroded
FUSELAGE STATION 1562 FRAME CHORD WAS FOUND CORRODED BEYOND ALLOWABLE LIMITS BETWEEN STRINGERS 38L AND 38R. THE (P/N 146T1223-30) CHORD WAS REPLACED PER DWG…
- 13 Oct 1999
Splice, corroded
STRINGER 38R SPLICE WAS FOUND CORRODED AT STATION 434, NO DAMAGE TO THE STRINGER WAS FOUND. THE (P/N 140T0115-16) SPLICE WAS REPLACED PER DWG 143T3210.
- 12 Oct 1999
Splice, corroded
STRINGER 35L SPLICE WAS FOUND CORRODED AT STA 434, NO DAMAGE TO THE STRINGER WAS FOUND. THE (P/N 140T0115-16) SPLICE WAS REPLACED PER DWG 145T3210.
- 12 Oct 1999
Splice, corroded
STRINGER 38L SPLICE WAS FOUND CORRODED AT STATION 434, NO DAMAGE TO STRINGER WAS FOUND. THE (P/N 140T0115-16) SPLICE WAS REPLACED PER DWG 143T3210.
- 12 Oct 1999
Splice, corroded
STRINGER 36R SPLICE WAS FOUND CORRODED AT STATION 434, NO DAMAGE TO THE STRINGER WAS FOUND. THE (P/N 140T0115-25) SPLICE WAS REPLACED PER DWG 143T3210.
- 12 Oct 1999
Splice, corroded
STRINGER 36L SPLICE WAS FOUND CORRODED AT STATION 434, NO DAMAGE TO STRINGER WAS FOUND. THE (P/N 140T0115-16) SPLICE WAS REPLACED PER DWG 145T3210.
- 6 Oct 1999
Stringer, corroded
CORROSION WAS FOUND IN STRINGER 39L AT STATION 1540 AND WAS BEYOND ALLOWABLE LIMITS. A REPLACEMENT SECTION OF STRINGER WAS SPLICED IN PER SRM 53-00-03-2-202.
- 6 Oct 1999
Stringer, corroded
STRINGER 38L AT STATION 1540 WAS FOUND CORRODED BEYOND ALLOWABLE LIMITS. A REPLACEMENT SECTION OF STRINGER WAS INSTALLED PER SRM 53-00-03-2-202.
- 6 Oct 1999
Shear Tie, corroded
SKIN TO FRAME ATTACH CLIP WAS FOUND CORRODED AT STA 1562 BETWEEN STRINGERS 38L AND 38R ON FWD SIDE OF STA 1562 FRAME. THE (P/N 140T2102-656) ATTACH CLIP WAS…
- 6 Oct 1999
Stringer, corroded
STRINGER 39R WAS FOUND CORRODED BEYOND ALLOWABLE LIMITS AT STA 1540. A REPLACEMENT SECTION OF STRINGER WAS INSTALLED PER SRM 53-00-03-2-202.
- 6 Oct 1999
Clip, corroded
FUSELAGE FRAME TO SKIN CLIP WAS FOUND CORRODED BEYOND ALLOWABLE LIMITS AT STA 1562 AND BL 0 BETWEEN STRINGERS 38L AND 38R. THE (P/N 140T2102-23) SKIN CLIP WAS…
- 3 Jan 1998
Light, inoperative
COCKPIT DOOR EMERGENCY LIGHT INOP DURING TEST. REPLACED LIGHT ASSY.
- 29 Nov 1997
Coffeemaker, failed
STRONG ELECTRICAL ODOR COMING FROM BEHIND COFFEEMAKERS IN FIRST CLASS GALLEY. ALSO, VERY HOT TO TOUCH ABOVE COFFEEMAKERS IN FLIGHT. REPLACED NUMBER 1 FIRST…
- 27 Aug 1997
Floorbeam, cracked
THE FS 246 FLOORBEAM WEB WAS FOUND WITH A 3.25 CRACK AT RBL 20. REPAIRED PER DAL ER/A.
- 10 Aug 1997
Threshold, corroded
THE BULK CARGO COMPARTMENT DOOR THRESHOLD COVER PLATE WAS REPLACED DUE TO CORROSION.
- 21 Feb 1996
Skin, dented
THE FUSELAGE SKIN IN THE VICINITY OF BS 456 AND CENTERED OVER THE S-36L LAP SPLICE WAS DAMAGED DUE TO CONTACT WITH GROUND EQUIPMENT. AS A RESULT, THE SKIN IN…
- 5 Oct 1995
Eel Bulb, failed
ON LAYOVER, EMERGENCY PATH LIGHT OUT AT ROW 21F. RELAMPED, OPERATION NORMAL.
- 23 Aug 1995
Eel Battery Pack, discharged
EMER LIGHTS AT AFT ENTRANCE DOORS AND AFT SECTION OF COACH TRACK LIGHT INOP. REPLACED BATTERY PACK, OPERATION NORMAL.
- 28 Jun 1995
Te Wedge, delaminated
DURING SHOP INSPECTION, SLAT PANEL WAS FOUND WITH T/E WEDGE DELAMINATED. REPLACED WEDGE PER SRM 57-43-37.
- 11 May 1995
Skin, damaged
FOUND ON J2 LETTER CHECK, HOLE IN NBR 1 FLAP I/B T/E LOWER SURFACE MARKED. REPAIRED PER SRM 57-53-01.
- 27 Jan 1995
Te Wedge, delamination
FOUND T/E DAMAGE DURING INSPECTION, REPLACE T/E WEDGE PER CMM 57-43-45, FOR NR 2 L/E SLAT PANEL.