N11551
2002 Embraer EMB-145LR standard FAA →
reservations
earlier registrations
2 past records
- 2002
service difficulty reports
60 reports
- 18 Apr 2020
Tray, defective
DURING MX INSPECTION THE LH AND RH OVERWING EMERGENCY LIGHT WOULD NOT ILLUMINATE. MX REMOVED AND REPLACED #4 EMERGENCY BATTERY TRAY WITH OPERATIONAL CHECK…
- 15 Apr 2020
Unknown, malfunctioned
DURING MX INSPECTION THE EXIT AISLE PATH LIGHTING FROM ROW 8 TO 11 WAS FOUND INOPERATIVE. ALSO EXIT ROW 18 UPPER AND LOWER SIDEWALL SIGNS INOP AND ROW 18 AFT…
- 11 Mar 2020
Wire Harness, defective
IAH - FLIGHT 4360, THE CREW REPORTED THAT AT APPROXIMATELY 800FT AND 240KIAS THE NOSE LANDING GEAR DOORS OPENED WITH THE GEAR SELECTPOR IN THE UP POSITION.…
- 7 Mar 2020
Battery, discharged
DURING ROUTINE MAINTENANCE THE EMERGENCY LIGHTING OVER WING AND AISLE LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE #4 EMERGENCY LIGHT BATTERY.…
- 2 Aug 2019
Battery Pack, inoperative
DURING MX THE MAIN DOOR AND COCKPIT EMERGENCY LIGHTS DID NOT WORK. MX R&R THE #1 EMERGENCY LIGHT BATTERY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR…
- 2 Aug 2019
Charger, inoperative
DURING MX THE OVERWING EMERGENCY LIGHTS WERE INOP. MX R&R #4 EMERGENCY BATTERY TRAY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.
- 18 Dec 2018
Battery Pack, inoperative
PILOT REPORTED EMERGENCY LIGHTS INOP FROM ROW 7 AND AFT.MX REMOVED AND REPLACED #1, #3, AND #4 EMERGENCY BATTERIES WITH OPS CHECK GOOD. A/C WAS APPROVED FOR…
- 22 Jul 2018
Battery Pack, discharged
NR 2 EMERGENCY LIGHT BATTERY PACK INOPERATIVE. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT BATTERY PACK IN ACCORDANCE WITH AMM 33-50-04. OPERATIONAL CHECK GOOD.
- 22 Jul 2018
Skin, dented
DURING "C" CHECK, A DENT WAS FOUND AT FRAME 5 AND STRINGER 5R AS A RESULT OF INSPECTION. COMPLETED FILLER AND DOUBLER REPAIR FOR DAMAGED AREA AT FRAME 5 AND…
- 18 Jul 2018
Battery Pack, discharged
EMERGENCY LIGHTS IN AFT CABIN DO NOT ILLUMINATE. REMOVED AND REPLACED NR 3 AND NR 4 BATTERY PACKS IN ACCORDANCE WITH AMM 33-50-04. OPERATIONAL CHECK GOOD.
- 15 Jul 2018
Skin, cracked
TYS A/C IS IN C-CHECK WHEN INSPECTION FOUND SKIN CRACKED AROUND HOLES UNDER THE RAD NR 2 FRAME 69. MAINTENANCE INSTALLED A REPAIR TO THE FUSELAGE SKIN AFT OF…
- 9 Jul 2018
Floor Support, corroded
A/C IS IN C-CHECK WHEN INSPECTION FOUND THE CENTER OMEGA BEAM AT FRAME 20WITH AN AREA OF CORROSION. MAINTENANCE REMOVED THE AREA OF CORROSION USING A NEW PART…
- 25 Jun 2018
Skin, buckled
DURING "C" CHECK, A BUCKLE WAS FOUND AT FRAME 3, FORWARD OF THE BATTERY DOOR AS A RESULT OF INSPECTION. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR IN…
- 11 Jan 2018
Inverter, inoperative
DURING A PREFLIGHT INSPECTION, THE AISLE EMERGENCY LIGHT STRIPS 2 & 3 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 2 EMERGENCY LIGHT INVERTER.…
- 12 Jan 2016
Frame, cracked
DURING C-CHECK FRAME 68 CRACKED AT CARGO DOOR HOLD OPEN CUP. REPAIRED FRAME 68 IAW EC 5330-03083. ACFT APPROVED FOR RETURN TO SERVICE.
- 27 Oct 2015
Battery Pack, discharged
DURING MAINTENANCE INSPECTION THE PROXIMITY LIGHTS AND OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 4 EMERGENCY LIGHT…
- 21 Jul 2014
Acm, failed
CREW REPORTED NR 2 PACK VALVE CLOSED IN FLIGHT, UNABLE TO RESET AND HAD A BURNING ODOR. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ACM. OPS CHECKED GOOD.
- 25 Jan 2014
Attach Bracket, worn
DURING C-CHECK, RT AILERON OTBD PCA LUG INBD HAT BUSHING MIGRATED. MAINTENANCE R & R BRACKET IAW EC5750-01177. ACFT APPROVED FOR RETURN TO SERVICE.
- 29 Aug 2013
Coffeemaker, smoke
THE CREW REPORTED INFLIGHT THE COFFEE POT SMOKED AND SMELLED OF BURNED POPCORN. THE COFFEEMAKER WAS IMMEDIATELY TURNED OFF. THE COFFEE MAKERS WERE PLACED ON…
- 27 May 2013
Unknown, odor
THE CREW REPORTED ODOR COMING FROM PACK 1 WHEN ENGINE BLEEDS WERE SELECTED. MX INSPECTED AND PERFORMED OPS CHECKS OF PACK 1, ENGINE BLEED 1. NO DEFECTS WERE…
- 12 Jan 2013
Unknown, odor
FLIGHT 4210, CREW REPORTED A MILD ODOR OF FUMES IN CABIN AND COCKPIT INFLIGHT WHICH MADE A PASSENGER SICK. MX RAN BOTH ENGINES AND PACK SYS AND PERFORMED OPS…
- 5 Apr 2012
Skin, dented
DENT BELOW CARGO DOOR BUMPER PLATE. CUT OUT CREASED AREA AND RECONTURED DENT. FABRICATED FILLER AND DOUBLER. ALODINED, PRIMED AND PAINTED FILLER AND DOUBLER.…
- 5 Apr 2012
Fitting, cracked
NR 1 PYLON FWD YOKE LWR FWD FITTING CRACKED. R & R NR 1 ENG FWD LWR FITTING.
- 29 Feb 2012
Fan, overheated
CREW REPORTED SMOKE IN CABIN IN FLIGHT. MX R & R NR 2 AHRS FAN FOR OVERHEATING AND INOPERATIVE IAW AMM 34-21-03 WITH OPS CHECK SUCCESSFUL. ACFT APPROVED FOR…
- 10 Nov 2011
Control Unit, faulty
CLE - FLT 4281 THE CREW REPORTED AFTER LANDING INITIAL BRAKING WAS GOOD THEN A LOSS OF BRAKING, RECEIVED A BRAKE DEGRADE MESSAGE THEN WENT AWAY. BRAKE TEMP…
- 14 Feb 2011
Connector, loose
FLIGHT 2312 - EWR - FLIGHT CREW REPORTED LG AIR/GND FAIL IN FLIGHT AND ON GROUND AFTER LANDING. EWR MX RE-SECURED LOOSE CONNECTOR FOR RIGHT GEAR WOW PROX…
- 23 Jan 2011
Charger, faulty
CLE FLT 6014 - THE CREW REPORTED THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE NR 4 EMERGENCY LIGHT…
- 24 Sep 2010
Inverter, inoperative
EMERGENCY FLOOR PROX LIGHT STRIPS 6, 7, 8 ARE INOP. REMOVED AND REPLACED NR 6 INVERTER, OPS CHECK GOOD.
- 23 May 2010
Floor Support, corroded
SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…
- 23 May 2010
Floor Support, corroded
SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 38. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…
- 23 May 2010
Floor Support, corroded
SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 54. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…
- 23 May 2010
Floor Support, corroded
SHV - DURING C-CHECK THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 59-60. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW…
- 23 May 2010
Door Frame, corroded
SHV - DURING C-CHECK THE AFT SERVICE DOOR FRAME WAS FOUND TO BE CORRODED AT FRAME 22 BETWEEN STRINGERS 15R AND 16R. MAINTENANCE REMOVED THE CORROSION AND…
- 17 Mar 2010
Inverter, inoperative
TYS DURING A OVERNIGHT THE A/C WAS FOUND WITH THE NR 3 INVERTER FOR THE EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED THE NR 3 INVERTER IAW EMB 145…
- 19 Nov 2009
Connector, loose
CLE FLT 2038 THE CREW REPORTED THE EMERGENCY AISLE PATH LIGHTING AT ROW 4 THRU 6 WERE INOPERATIVE. MAINTENANCE INSPECTED AND RE-SECURED A LOOSE CONNECTOR AND…
- 29 Sep 2009
Light, malfunctioned
IAH - FLIGHT 3086 - DURING PREFLIGHT INSPECTION THE CREW REPORTED A FLOOR LEVEL EMERGENCY LIGHT HAD ONE SECTION NOT ILLUMINATING. MAINTENANCE VERIFIED NORMAL…
- 30 Aug 2009
Skin, dented
DENT TO LWR FWD FUSELAGE NEAR RVSM AREA. REPLACED SKIN IAW EC5330-01975.
- 19 Apr 2009
Inverter, inoperative
MCI - DURING MAINTENANCE INSPECTION AISLE PATH EGRESS LIGHTS NUMBER FOUR & FIVE, AND THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE…
- 27 Mar 2009
Unknown, odor
FLIGHT 3050 - EWR - FLIGHT CREW REPORTED ELECTRIC BURNING SMELL IN FLIGHT DECK DURING CLIMB. CREW PERFORMED AIR RETURN AND LANDED UNEVENTFULLY. EWR MX…
- 26 Mar 2009
Anti-Ice Valve, inoperative
FLIGHT 2077 - EWR - FLIGHT CREW PERFORMED AIR RETURN DUE TO "WING A/I FAIL" MESSAGE ON EICAS IN ICING CONDITION AND NO "OPEN" LIGHT ON WING A/I BUTTON. CREW…
- 22 Jan 2009
Fire Loop, chafed
E1 FIRE DETECT FAIL MSG. R&R FIRE LOOP ON ENG 1 IAW EMB 145 AMM 26-11-01. OPS CHECK GOOD. ACFT RELEASED FOR SERVICE
- 10 Oct 2008
Ballast, inoperative
IAH DURING MX INSPECTION A BURNING ODOR IN THE LAV WAS DISCOVERED. MX R&R THE LT LIGHT BALLAST IN THE LAV. OPS CHECKED WITH NO DEFECTS AND THE ACFT WAS…
- 27 Aug 2008
Battery, discharged
FLT MX ONT WHILE PERFORMING PRELIMINARY INSPECTION ON ACFT 551 SCHEDULE 4A CHECK INSPECTOR FOUND EMERGENCY PROXIMITY LIGHT OUT BTW ROWS 8 AND 12. MX PERSONNEL…
- 8 Aug 2008
Window, out of adjust
FLT 0312-IAH, FLIGHT CREW REPORTED LOUD PIERCING SQUEAL FROM CAPT DV WINDOW ON FLIGHT FROM AUS TO JAX DIVERTED TO IAH. MAINTENANCE PERSONNEL RE-ADJUSTED DV…
- 17 Jun 2008
Battery, inoperative
LT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED NR 1 EMERGENCY LIGHT BATTERY IAW EMB 145 AMM 33-50-04. OPS CHECK GOOD. (S)
- 7 Nov 2007
O-Ring, damaged
FLT 115 - BOI TO ONT - FLIGHT CREW REPORTED RIGHT WING FUEL LEAK DURING PRE-FLIGHT WALK AROUND. MX SENT A MECHANIC TO BOI WITH PART TO BE CHANGED AND…
- 29 Oct 2007
Floorbeam, corroded
SHV - DURING C-CHECK CENTER OMEGA BEAM CORROED BEYOND ALLOWABLE LIMITS ON FR 20. MAINTENANCE REMOVED AND REPLACED CENTER OMEGA BEAM FROM 18 TO 23 IAW EMB 145…
- 13 Aug 2007
Unknown, odor
FLT 534 - RDU - DURING PREFLIGHT, CREW REPORTED ELECTRICAL BURNING SMELL IN CABIN. MX POWERED ACFT AND TURNED ON LIGHTS AND EQUIPMENT IN CABIN, BUT COULD NOT…
- 4 May 2007
Battery, discharged
IAH - DURING MAINTENANCE INSPECTION THE FORWARD EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE EMERGENCY LIGHT…
- 30 Dec 2006
Light, inoperative
IAH - DURING MX INSPECTION, THE RIGHT HAND UPPER EXTERIOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT…
- 22 May 2006
Inverter, inoperative
STL - DURING MAINTENANCE INSPECTION, THE FLOOR PROXIMITY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO EMERGENCY LIGHT…
- 1 Nov 2005
Floor Support, corroded
SHV - DURING C-CHECK MAINTENANCE FOUND LT OMEGA BEAM CORRODED AT FRAME 20. MAINTENANCE REPAIRED LT OMEGA BEAM AT FRAME 20 IAW EMB 145 SRM 51-40-02 & EC…
- 1 Nov 2005
Floor Support, corroded
SHV - DURING C-CHECK MAINTENANCE FOUND CENTER OMEGA BEAM AT FRAME 20 WITH CORROSION BETWEEN RAMP ANGLE AND BUTTSTRAP. MAINTENANCE REPAIRED CENTER OMEGA BEAM…
- 1 Nov 2005
Firewall, cracked
SHV - DURING C-CHECK MAINTENANCE FOUND APU FIREWALL CRACKED ON RT SIDE 3 O'CLOCK POSITION AT END OF STIFFENER. MAINTENANCE REPAIRED APU FIREWALL RT SIDE AT 3…
- 1 Nov 2005
Firewall, cracked
SHV - DURING C-CHECK MAINTENANCE FOUND APU FIREWALL CRACKED AT RIVET ADJACENT TO RT SIDE OF COWLING ALIGNMENT PIN. MAINTENANCE REPAIRED APU FIREWALL AT RT…
- 1 Nov 2005
Firewall, cracked
SHV - DURING CHECK MAINTENANCE FOUND APU FIREWALL CRACKED AT FASTENER AT STR 16R. MAINTENANCE REPAIRED APU FIREWALL IAW EMB 145 SRM 53-32-13. AIRCRAFT WAS…
- 31 Jan 2004
Angle, corroded
TYS DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE OMEGA BEAM RAMP ANGLE AT FRAME 20. MAINTENANCE ACCOMPLISHED A DOUBLER REPAIR IAW EMB SRM 53-21-10…
- 12 Dec 2002
Windshield, cracked
IAH- DURING CLIMB OUT THE CREW NOTED THAT THE CAPTAINS WINDSHIELD SHATTERED IN FLIGHT. THE CREW DID AN AIR RETURN TO IAH, AND, LANDED WITHOUT INCIDENT. IAH-…
- 27 Oct 2002
Engine, leaking
CREW REPORTED SMOKE IN CABIN WITH EITHER ENGINE BLEED SELECTED AND LAV SMOKE INDICATION. MAINTENANCE DETERMINED SMOKE COMING FROM AN OIL LEAK INTERNAL TO THE…
- 15 Aug 2002
Engine, odor
EWR---CO3516, CREW REPORTED, "VERY ACRID ODOR AND SMALL AMOUNT OF SMOKE FROM #1 PACK AFTER ENGINE BLEED SELECTED ON CLIMBOUT" MAINTENANCE FOUND EVIDENCE OF…