search

N11551

2002 Embraer EMB-145LR standard FAA →

reservations

  1. reserved 26 Apr 2023

earlier registrations

2 past records
  1. 2002

    Tvpx Aircraft Solutions INC Trustee

    2002 Embraer EMB-145LR

    deregistered 26 Apr 2023 exported to Israel

    s/n 145411 engine Rolls-Royc Ae 3007A1P

  2. Memphis Navy Flying Club INC

    Cessna 150L

    deregistered 2 Apr 1975 exported to Canada

    s/n 15075513

service difficulty reports

60 reports
  1. 18 Apr 2020

    Tray, defective

    Emb EMB145LR

    DURING MX INSPECTION THE LH AND RH OVERWING EMERGENCY LIGHT WOULD NOT ILLUMINATE. MX REMOVED AND REPLACED #4 EMERGENCY BATTERY TRAY WITH OPERATIONAL CHECK…

  2. 15 Apr 2020

    Unknown, malfunctioned

    Emb EMB145LR

    DURING MX INSPECTION THE EXIT AISLE PATH LIGHTING FROM ROW 8 TO 11 WAS FOUND INOPERATIVE. ALSO EXIT ROW 18 UPPER AND LOWER SIDEWALL SIGNS INOP AND ROW 18 AFT…

  3. 11 Mar 2020

    Wire Harness, defective

    Emb EMB145LR

    IAH - FLIGHT 4360, THE CREW REPORTED THAT AT APPROXIMATELY 800FT AND 240KIAS THE NOSE LANDING GEAR DOORS OPENED WITH THE GEAR SELECTPOR IN THE UP POSITION.…

  4. 7 Mar 2020

    Battery, discharged

    Emb EMB145LR

    DURING ROUTINE MAINTENANCE THE EMERGENCY LIGHTING OVER WING AND AISLE LIGHTS WERE INOPERATIVE. MAINTENANCE REPLACED THE #4 EMERGENCY LIGHT BATTERY.…

  5. 2 Aug 2019

    Battery Pack, inoperative

    Emb EMB145LR

    DURING MX THE MAIN DOOR AND COCKPIT EMERGENCY LIGHTS DID NOT WORK. MX R&R THE #1 EMERGENCY LIGHT BATTERY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR…

  6. 2 Aug 2019

    Charger, inoperative

    Emb EMB145LR

    DURING MX THE OVERWING EMERGENCY LIGHTS WERE INOP. MX R&R #4 EMERGENCY BATTERY TRAY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.

  7. 18 Dec 2018

    Battery Pack, inoperative

    Emb EMB145LR

    PILOT REPORTED EMERGENCY LIGHTS INOP FROM ROW 7 AND AFT.MX REMOVED AND REPLACED #1, #3, AND #4 EMERGENCY BATTERIES WITH OPS CHECK GOOD. A/C WAS APPROVED FOR…

  8. 22 Jul 2018

    Battery Pack, discharged

    Emb EMB145LR

    NR 2 EMERGENCY LIGHT BATTERY PACK INOPERATIVE. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT BATTERY PACK IN ACCORDANCE WITH AMM 33-50-04. OPERATIONAL CHECK GOOD.

  9. 22 Jul 2018

    Skin, dented

    Emb EMB145LR

    DURING "C" CHECK, A DENT WAS FOUND AT FRAME 5 AND STRINGER 5R AS A RESULT OF INSPECTION. COMPLETED FILLER AND DOUBLER REPAIR FOR DAMAGED AREA AT FRAME 5 AND…

  10. 18 Jul 2018

    Battery Pack, discharged

    Emb EMB145LR

    EMERGENCY LIGHTS IN AFT CABIN DO NOT ILLUMINATE. REMOVED AND REPLACED NR 3 AND NR 4 BATTERY PACKS IN ACCORDANCE WITH AMM 33-50-04. OPERATIONAL CHECK GOOD.

  11. 15 Jul 2018

    Skin, cracked

    Emb EMB145LR

    TYS A/C IS IN C-CHECK WHEN INSPECTION FOUND SKIN CRACKED AROUND HOLES UNDER THE RAD NR 2 FRAME 69. MAINTENANCE INSTALLED A REPAIR TO THE FUSELAGE SKIN AFT OF…

  12. 9 Jul 2018

    Floor Support, corroded

    Emb EMB145LR

    A/C IS IN C-CHECK WHEN INSPECTION FOUND THE CENTER OMEGA BEAM AT FRAME 20WITH AN AREA OF CORROSION. MAINTENANCE REMOVED THE AREA OF CORROSION USING A NEW PART…

  13. 25 Jun 2018

    Skin, buckled

    Emb EMB145LR

    DURING "C" CHECK, A BUCKLE WAS FOUND AT FRAME 3, FORWARD OF THE BATTERY DOOR AS A RESULT OF INSPECTION. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR IN…

  14. 11 Jan 2018

    Inverter, inoperative

    Emb EMB145LR

    DURING A PREFLIGHT INSPECTION, THE AISLE EMERGENCY LIGHT STRIPS 2 & 3 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 2 EMERGENCY LIGHT INVERTER.…

  15. 12 Jan 2016

    Frame, cracked

    Emb EMB145LR

    DURING C-CHECK FRAME 68 CRACKED AT CARGO DOOR HOLD OPEN CUP. REPAIRED FRAME 68 IAW EC 5330-03083. ACFT APPROVED FOR RETURN TO SERVICE.

  16. 27 Oct 2015

    Battery Pack, discharged

    Emb EMB145LR

    DURING MAINTENANCE INSPECTION THE PROXIMITY LIGHTS AND OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 4 EMERGENCY LIGHT…

  17. 21 Jul 2014

    Acm, failed

    Emb EMB145

    CREW REPORTED NR 2 PACK VALVE CLOSED IN FLIGHT, UNABLE TO RESET AND HAD A BURNING ODOR. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ACM. OPS CHECKED GOOD.

  18. 25 Jan 2014

    Attach Bracket, worn

    Emb EMB145LR

    DURING C-CHECK, RT AILERON OTBD PCA LUG INBD HAT BUSHING MIGRATED. MAINTENANCE R & R BRACKET IAW EC5750-01177. ACFT APPROVED FOR RETURN TO SERVICE.

  19. 29 Aug 2013

    Coffeemaker, smoke

    Emb EMB145LR

    THE CREW REPORTED INFLIGHT THE COFFEE POT SMOKED AND SMELLED OF BURNED POPCORN. THE COFFEEMAKER WAS IMMEDIATELY TURNED OFF. THE COFFEE MAKERS WERE PLACED ON…

  20. 27 May 2013

    Unknown, odor

    Emb EMB145LR

    THE CREW REPORTED ODOR COMING FROM PACK 1 WHEN ENGINE BLEEDS WERE SELECTED. MX INSPECTED AND PERFORMED OPS CHECKS OF PACK 1, ENGINE BLEED 1. NO DEFECTS WERE…

  21. 12 Jan 2013

    Unknown, odor

    Emb EMB145LR

    FLIGHT 4210, CREW REPORTED A MILD ODOR OF FUMES IN CABIN AND COCKPIT INFLIGHT WHICH MADE A PASSENGER SICK. MX RAN BOTH ENGINES AND PACK SYS AND PERFORMED OPS…

  22. 5 Apr 2012

    Skin, dented

    Emb EMB145LR

    DENT BELOW CARGO DOOR BUMPER PLATE. CUT OUT CREASED AREA AND RECONTURED DENT. FABRICATED FILLER AND DOUBLER. ALODINED, PRIMED AND PAINTED FILLER AND DOUBLER.…

  23. 5 Apr 2012

    Fitting, cracked

    Emb EMB145LR

    NR 1 PYLON FWD YOKE LWR FWD FITTING CRACKED. R & R NR 1 ENG FWD LWR FITTING.

  24. 29 Feb 2012

    Fan, overheated

    Emb EMB145LR

    CREW REPORTED SMOKE IN CABIN IN FLIGHT. MX R & R NR 2 AHRS FAN FOR OVERHEATING AND INOPERATIVE IAW AMM 34-21-03 WITH OPS CHECK SUCCESSFUL. ACFT APPROVED FOR…

  25. 10 Nov 2011

    Control Unit, faulty

    Emb EMB145LR

    CLE - FLT 4281 THE CREW REPORTED AFTER LANDING INITIAL BRAKING WAS GOOD THEN A LOSS OF BRAKING, RECEIVED A BRAKE DEGRADE MESSAGE THEN WENT AWAY. BRAKE TEMP…

  26. 14 Feb 2011

    Connector, loose

    Emb EMB145LR

    FLIGHT 2312 - EWR - FLIGHT CREW REPORTED LG AIR/GND FAIL IN FLIGHT AND ON GROUND AFTER LANDING. EWR MX RE-SECURED LOOSE CONNECTOR FOR RIGHT GEAR WOW PROX…

  27. 23 Jan 2011

    Charger, faulty

    Emb EMB145LR

    CLE FLT 6014 - THE CREW REPORTED THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE NR 4 EMERGENCY LIGHT…

  28. 24 Sep 2010

    Inverter, inoperative

    Emb EMB145LR

    EMERGENCY FLOOR PROX LIGHT STRIPS 6, 7, 8 ARE INOP. REMOVED AND REPLACED NR 6 INVERTER, OPS CHECK GOOD.

  29. 23 May 2010

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…

  30. 23 May 2010

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 38. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…

  31. 23 May 2010

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 54. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM…

  32. 23 May 2010

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 59-60. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW…

  33. 23 May 2010

    Door Frame, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK THE AFT SERVICE DOOR FRAME WAS FOUND TO BE CORRODED AT FRAME 22 BETWEEN STRINGERS 15R AND 16R. MAINTENANCE REMOVED THE CORROSION AND…

  34. 17 Mar 2010

    Inverter, inoperative

    Emb EMB145LR

    TYS DURING A OVERNIGHT THE A/C WAS FOUND WITH THE NR 3 INVERTER FOR THE EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED THE NR 3 INVERTER IAW EMB 145…

  35. 19 Nov 2009

    Connector, loose

    Emb EMB145LR

    CLE FLT 2038 THE CREW REPORTED THE EMERGENCY AISLE PATH LIGHTING AT ROW 4 THRU 6 WERE INOPERATIVE. MAINTENANCE INSPECTED AND RE-SECURED A LOOSE CONNECTOR AND…

  36. 29 Sep 2009

    Light, malfunctioned

    Emb EMB145LR

    IAH - FLIGHT 3086 - DURING PREFLIGHT INSPECTION THE CREW REPORTED A FLOOR LEVEL EMERGENCY LIGHT HAD ONE SECTION NOT ILLUMINATING. MAINTENANCE VERIFIED NORMAL…

  37. 30 Aug 2009

    Skin, dented

    Emb EMB145LR

    DENT TO LWR FWD FUSELAGE NEAR RVSM AREA. REPLACED SKIN IAW EC5330-01975.

  38. 19 Apr 2009

    Inverter, inoperative

    Emb EMB145LR

    MCI - DURING MAINTENANCE INSPECTION AISLE PATH EGRESS LIGHTS NUMBER FOUR & FIVE, AND THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE…

  39. 27 Mar 2009

    Unknown, odor

    Emb EMB145LR

    FLIGHT 3050 - EWR - FLIGHT CREW REPORTED ELECTRIC BURNING SMELL IN FLIGHT DECK DURING CLIMB. CREW PERFORMED AIR RETURN AND LANDED UNEVENTFULLY. EWR MX…

  40. 26 Mar 2009

    Anti-Ice Valve, inoperative

    Emb EMB145LR

    FLIGHT 2077 - EWR - FLIGHT CREW PERFORMED AIR RETURN DUE TO "WING A/I FAIL" MESSAGE ON EICAS IN ICING CONDITION AND NO "OPEN" LIGHT ON WING A/I BUTTON. CREW…

  41. 22 Jan 2009

    Fire Loop, chafed

    Emb EMB145

    E1 FIRE DETECT FAIL MSG. R&R FIRE LOOP ON ENG 1 IAW EMB 145 AMM 26-11-01. OPS CHECK GOOD. ACFT RELEASED FOR SERVICE

  42. 10 Oct 2008

    Ballast, inoperative

    Emb EMB145LR

    IAH DURING MX INSPECTION A BURNING ODOR IN THE LAV WAS DISCOVERED. MX R&R THE LT LIGHT BALLAST IN THE LAV. OPS CHECKED WITH NO DEFECTS AND THE ACFT WAS…

  43. 27 Aug 2008

    Battery, discharged

    Emb EMB145LR

    FLT MX ONT WHILE PERFORMING PRELIMINARY INSPECTION ON ACFT 551 SCHEDULE 4A CHECK INSPECTOR FOUND EMERGENCY PROXIMITY LIGHT OUT BTW ROWS 8 AND 12. MX PERSONNEL…

  44. 8 Aug 2008

    Window, out of adjust

    Emb EMB145LR

    FLT 0312-IAH, FLIGHT CREW REPORTED LOUD PIERCING SQUEAL FROM CAPT DV WINDOW ON FLIGHT FROM AUS TO JAX DIVERTED TO IAH. MAINTENANCE PERSONNEL RE-ADJUSTED DV…

  45. 17 Jun 2008

    Battery, inoperative

    Emb EMB145LR

    LT OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED NR 1 EMERGENCY LIGHT BATTERY IAW EMB 145 AMM 33-50-04. OPS CHECK GOOD. (S)

  46. 7 Nov 2007

    O-Ring, damaged

    Emb EMB145LR

    FLT 115 - BOI TO ONT - FLIGHT CREW REPORTED RIGHT WING FUEL LEAK DURING PRE-FLIGHT WALK AROUND. MX SENT A MECHANIC TO BOI WITH PART TO BE CHANGED AND…

  47. 29 Oct 2007

    Floorbeam, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK CENTER OMEGA BEAM CORROED BEYOND ALLOWABLE LIMITS ON FR 20. MAINTENANCE REMOVED AND REPLACED CENTER OMEGA BEAM FROM 18 TO 23 IAW EMB 145…

  48. 13 Aug 2007

    Unknown, odor

    Emb EMB145LR

    FLT 534 - RDU - DURING PREFLIGHT, CREW REPORTED ELECTRICAL BURNING SMELL IN CABIN. MX POWERED ACFT AND TURNED ON LIGHTS AND EQUIPMENT IN CABIN, BUT COULD NOT…

  49. 4 May 2007

    Battery, discharged

    Emb EMB145LR

    IAH - DURING MAINTENANCE INSPECTION THE FORWARD EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE EMERGENCY LIGHT…

  50. 30 Dec 2006

    Light, inoperative

    Emb EMB145LR

    IAH - DURING MX INSPECTION, THE RIGHT HAND UPPER EXTERIOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT…

  51. 22 May 2006

    Inverter, inoperative

    Emb EMB145LR

    STL - DURING MAINTENANCE INSPECTION, THE FLOOR PROXIMITY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO EMERGENCY LIGHT…

  52. 1 Nov 2005

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK MAINTENANCE FOUND LT OMEGA BEAM CORRODED AT FRAME 20. MAINTENANCE REPAIRED LT OMEGA BEAM AT FRAME 20 IAW EMB 145 SRM 51-40-02 & EC…

  53. 1 Nov 2005

    Floor Support, corroded

    Emb EMB145LR

    SHV - DURING C-CHECK MAINTENANCE FOUND CENTER OMEGA BEAM AT FRAME 20 WITH CORROSION BETWEEN RAMP ANGLE AND BUTTSTRAP. MAINTENANCE REPAIRED CENTER OMEGA BEAM…

  54. 1 Nov 2005

    Firewall, cracked

    Emb EMB145LR

    SHV - DURING C-CHECK MAINTENANCE FOUND APU FIREWALL CRACKED ON RT SIDE 3 O'CLOCK POSITION AT END OF STIFFENER. MAINTENANCE REPAIRED APU FIREWALL RT SIDE AT 3…

  55. 1 Nov 2005

    Firewall, cracked

    Emb EMB145LR

    SHV - DURING C-CHECK MAINTENANCE FOUND APU FIREWALL CRACKED AT RIVET ADJACENT TO RT SIDE OF COWLING ALIGNMENT PIN. MAINTENANCE REPAIRED APU FIREWALL AT RT…

  56. 1 Nov 2005

    Firewall, cracked

    Emb EMB145LR

    SHV - DURING CHECK MAINTENANCE FOUND APU FIREWALL CRACKED AT FASTENER AT STR 16R. MAINTENANCE REPAIRED APU FIREWALL IAW EMB 145 SRM 53-32-13. AIRCRAFT WAS…

  57. 31 Jan 2004

    Angle, corroded

    Emb EMB145LR

    TYS DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE OMEGA BEAM RAMP ANGLE AT FRAME 20. MAINTENANCE ACCOMPLISHED A DOUBLER REPAIR IAW EMB SRM 53-21-10…

  58. 12 Dec 2002

    Windshield, cracked

    Emb EMB145LR

    IAH- DURING CLIMB OUT THE CREW NOTED THAT THE CAPTAINS WINDSHIELD SHATTERED IN FLIGHT. THE CREW DID AN AIR RETURN TO IAH, AND, LANDED WITHOUT INCIDENT. IAH-…

  59. 27 Oct 2002

    Engine, leaking

    Emb EMB145LR

    CREW REPORTED SMOKE IN CABIN WITH EITHER ENGINE BLEED SELECTED AND LAV SMOKE INDICATION. MAINTENANCE DETERMINED SMOKE COMING FROM AN OIL LEAK INTERNAL TO THE…

  60. 15 Aug 2002

    Engine, odor

    Emb EMB145LR

    EWR---CO3516, CREW REPORTED, "VERY ACRID ODOR AND SMALL AMOUNT OF SMOKE FROM #1 PACK AFTER ENGINE BLEED SELECTED ON CLIMBOUT" MAINTENANCE FOUND EVIDENCE OF…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05223 Nov 2026
FCC GMRS633,26623 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,80320 Nov 2026
FAA registered aircraft319,53720 Nov 2026
FAA N-number reservations125,98920 Nov 2026
FAA dealers12,50720 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,08023 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.