N108BZ
2007 Embraer ERJ 190-100 IGW standard FAA →
reservations
earlier registrations
1 past record
- 2007
service difficulty reports
14 reports
- 20 Aug 2025
Power Supply, failed
ELPU FAULTY, EPSU 2 FAIL, REPLACED EPSU 2.
- 18 Aug 2025
Power Supply, no test
EMERGENCY LIGHT FAULT - EMERGENCY LIGHT BATTERY FAULTED. REPLACED LH CTR EMERGENCY LIGHT POWER SUPPLY.
- 23 Apr 2025
Power Supply, no test
ELPU R/H INBOARD FAILED OPS TEST. R/R ELPU IAW E190 AMM 33-50-01.
- 29 Oct 2023
Unknown, unknown
FLIGHT CONTROL ISSUES DURING APPROACH. WHILE IN A TURN AND DESCENT, AND IN MODERATE TURBULENCE FLIGHT CONTROLS LOCKED UP. UNABLE TO BANK OR PITCH. AIRCRAFT…
- 18 Aug 2023
Support Bracket, cracked
RUDDER PEDAL DAMPER BRACKET CRACKED. PERMANENT REPAIR (BY REPLACEMENT) OF RUDDER PEDAL DAMPER SUPPORT (P/N 170-08554-401)
- 10 May 2023
Unknown, unknown
LH AND RH BRAKE FAIL WHILE TAXING IN. LOST BRAKING AUTHORITY FROM BOTH PEDALS. PERFORMED OPS TEST OF MAIN BRAKE SYSTEM AND NO FAULTS NOTED. VISUAL CHECK OF…
- 13 Dec 2022
Wire Harness, damaged
AFT SERVICE DOOR EMERGENCY LIGHTS EXIT IDENTIFIER INOP - REPAIRED WIRE HARNESS W201-02338-20 BY INSTALLING NEW CONTACT PINS IN REMOVABLE SPLICE IAW SWPM…
- 12 Dec 2022
Unknown, unknown
THIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. AFT SERVICE DOOR EMERGENCY LIGHTS EXIT IDENTIFIER WAS INOP. REPAIRED WIRE HARNESS FOR FIX. THIS SDR REVISED DUE…
- 12 Dec 2022
Unknown, unknown
THIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. AFT SERVICE DOOR EMERGENCY LIGHTS EXIT IDENTIFIER WAS INOP. REPAIRED WIRE HARNESS FOR FIX.
- 19 Nov 2022
Beam, corroded
CORROSION ON FWD PAX DOOR LOWER BEAM SEVERAL SPOTS BETWEEN FR16-FR19 AND STRGR 17L BELOW EVACUATION SLIDE FLOOR FITTINGS - REMOVED AND REPLACED PAX DOOR LOWER…
- 19 Nov 2022
Rib, cracked
LH LOWER WING CRACKED AT SPAR 2 RIB 10 - REPAIRED L/W LOWER SKIN AT SPAR 2 RIB 10 IAW ETD2022-190-032836 REV / AND BREEZE TASK CARD CATA-57EA-00532
- 19 Nov 2022
Rib, cracked
RH LOWER WING CRACKED AT SPAR 2 RIB 10 - REPAIRED R/W LOWER SKIN AT SPAR 2 RIB 10 IAW ETD2022-190-032840 REV A
- 25 May 2022
None, unserviceable
CENTER FUSELAGE EMERGENGY DOORS L/H AND R/H EMERGENGY LIGHTING EXIT MARKING SIGNS FOUND INOP DURING 14 DAY INSP. - REPLACED MIDDLE RH EMERGENCY LIGHT POWER…
- 25 May 2022
Battery, discharged
THIS SDR SUBMITTED LATE DUE AUDIT FINDING. CENTER FUSELAGE EMERGENGY DOORS L/H AND R/H EMERGENGY LIGHTING EXIT MARKING SIGNS FOUND INOP DURING 14 DAY INSP.