N107XJ
Saab-Fairchild 340A standard FAA →
reservations
earlier registrations
1 past record
service difficulty reports
33 reports
- 2 Jan 2002
Battery Pack, discharged
DURING TURNBACK INSPECTION NOTED EMERGENCY LIGHT POWER SUPPLY 22LN VOLTAGE TO BE LOW. MAINTENANCE REMOVED AND REPLACED BATTERY PAC ON EMERGENCY LIGHTING POWER…
- 25 Oct 2001
Control Unit, faulty
DURING FLIGHT 3172, RT ENGINE INTAKE LIP ACCUMULATED SIGNIFICANT ICE WITH ALL ENGINE ANTI-ICE SYSTEMS WORKING OK. MAINTENANCE CONDUCTED OPERATIONAL CHECK IAW…
- 1 Apr 2001
Ejector Valve, failed
ON CLIMBOUT FROM DTW ON FLIGHT 2800, STAB DEICE LIGHT WOULD NOT ILLUMINATE. TRIED MANUAL INFLATION AND LIGHT FLICKERED BUT DID NOT ILLUMINATE STEADY. TRIED…
- 7 Apr 2000
Skin, chafed
RT NACELLE INBOARD SKIN IS CHAFED. DISCOVERED DURING HEAVY CHECK AND REPAIRED IAW EO554033.
- 13 Feb 2000
Connector, contaminated
LEFT AIR VLAVE CAUTION LIGHT ILLUMINATES WHEN THE LEFT ENGINE ANTI-ICE SWITCH IS TURNED ON. MAINTENANCE FOUND CANNON PLUG FROM GREEN HARNESS TO VALVE FULL OF…
- 23 Dec 1999
Exhaust Nozzle, loose
LEFT INTAKE LIGHT CAME ON IN FLIGHT. QRH DIDN'T CORRECT THE PROBLEM. RETRUNED TO CWA. MAINTENANCE TROUBLESHOT SYSTEM, RESECURED EXHAUST NOZZLE ENVIROMENTAL…
- 25 Sep 1999
Retract Mech, malfunctioned
LANDING GEAR DID NOT COME DOWN AFTER SELECTED. CREW FOLLOWED QRH AND FOUND F7 CIRCUIT BREAKER OUT, RESET AND SYSTEM WORKED NORMALLY. MAINTENANCE PERFORMED…
- 1 Feb 1999
Fitting, broken
AFTER GEAR EXTENSION, HAD A HYDR FROM CWP, MAIN HYDRAULIC PRESSURE DECREASED TO ZERO AND HYDRAULIC QUANTITY DECREASED TO ZERO. AIRCRAFT LANDED WITHOUT…
- 1 Feb 1999
Actuator, failed
AFTER GEAR EXTENSION, HYDRAULIC PRESSURE DECREASED TO ZERO. MAINTENANCE REPLACED LT MLG ACTUATOR, ALL CHECKS GOOD.
- 19 Jan 1999
Cowl, loose
ON POST FLIGHT WALKAROUND, NOTED RIGHT COWL ABOVE PROP WAS LOOSE. LOOSE COWL HAD NICKED THE PROPS APPROXIMATELY 1 BY .5 INCH. MAINTENANCE INSPECTED RIGHT HAND…
- 19 Dec 1998
Wire Harness, failed
LT PROP ICE CAUTION LIGHT ILLUMINATES AFTER 1:10 SEC. AIRCRAFT RETURNED TO MSP. MAINTENANCE REPLACED WIRE HARNESS. OPS CHECKS GOOD.
- 8 Apr 1998
Caution Light, illuminated
ON DESCENT INTO MSP WHEN LOWERING GEAR, THE HYDRAULIC CAUTION LIGHT ILLUMINATED AND NOSE GEAR LIGHT WAS THE ONLY ONE TO ILLUMINATE. HYDRAULIC PUMP WAS…
- 7 Apr 1998
Lock Switch, internal fault
DURING CLIMB, CARGO DOOR WARNING LIGHT ILLUMINATED. MAINTENANCE REPLACED DOOR LOCK SWITCH. OPS CHECK GOOD.
- 31 Mar 1998
Overheat Light, illuminated
ON CLIMB, LEFT TAILPIPE HOT WARNING LIGHT ILLUMINATED, COMPLETED QRH AND WARNING LIGHT EXTINGUISHED AFTER CLOSING BLEED VALVE. AIRCRAFT RETURNED TO ATW.…
- 2 Mar 1998
Bulb, failed
DURING INSPECTION, 6A EMERGENCY EXIT SIGN INOP. MAINTENANCE RELAMPED EXIT SIGN, ALL CHECKS GOOD.
- 26 Feb 1998
Connector, loose
DURING INSPECTION, EMERGENCY FLOOR TRACK 9C/D INOP. MAINTENANCE RESECURED LOOSE CONNECTOR, OPS CHECK GOOD.
- 20 Feb 1998
Light, inoperative
DURING INSPECTION, EMERGENCY FLOOR TRACK LIGHT INOP AT 9C. MAINTENANCE RECYCLED POWER, ALL CHECKS GOOD.
- 29 Jan 1998
Battery Pack, discharged
DURING INSPECTION, EMERGENCY LIGHT INOP OVER SEATS 1 C/D AND 3 C/D. MAINTENANCE REPLACED POSITION 20LN BATTERY PACK, OPS CHECK GOOD.
- 28 Jan 1998
Battery Pack, discharged
DURING INSPECTION, SEVERAL EMERGENCY LIGHTS INOP. MAINTENANCE REPLACED ALL EMERGENCY LIGHT BATTERY PACKS, OPS CHECK GOOD.
- 19 Jan 1998
Terminal, melted
DURING FLIGHT, A BURNING SMELL COMING FROM THE LEFT AC SYSTEM, CREW SHUT OFF BLEED SYSTEM. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENACE FOUND LOWER TERMINAL…
- 15 Jan 1998
Air Distribution, odor
DURING CRUISE FLIGHT AT 17,000, THE CREW SMELLED BURNING WIRE, NO SMOKE VISIBLE. CREW RAN QRH AND FOUND CIRCUIT BREAKERS L2, RH TAIL PIPE HOT DETECTION AND…
- 13 Jan 1998
Lamp, failed
DURING INSPECTION, EMERGENCY LIGHTS IN ROW 4 AND 6 INOP. MAINTENANCE RELAMP EMERGENCY LIGHTS IN ROWS 4 AND 6, OPS CHECK GOOD.
- 2 Oct 1997
Bulb, failed
DURING INSPECTION EMERGENCY LIGHT 1C AND D, 2A, 4A AND 7CD INOP. MAINTENANCE RELAMPED. OPS CHECK GOOD. (M)
- 29 Sep 1997
Light, inoperative
DURING INSPECTION, ONE FORWARD FLOOR TRACK LIGHT FOUND INOPERABLE. MAINTENANCE REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD. (X)
- 24 Sep 1997
Connector, disconnected
DURING INSPECTION, EMERGENCY EXIT LIGHT OVER FLIGHT ATTENDANT SEAT INOP. MAINTENANCE FOUND CANNON PLUG FOR FA SEAT CABINET TO BE DISCONNECTED. RECONNECTED…
- 26 Aug 1997
Bulb, failed
DURING INSPECTION, EMERGENCY LIGHT OUT AT 6A AND C. MAINTENANCE RELAMPED. OPS CHECK GOOD. (X)
- 27 Jul 1997
Lamp, failed
DURING INSPECTION, ONE EMERGENCY SIDEWALL LIGHT AND ONE OVERHEAD EMERGENCY LIGHT INOP. MAINTENANCE RELAMPED. OPS CHECK GOOD. (M)
- 31 May 1997
Bulb, failed
DURING INSPECTION, ONE CABIN OVERHEAD EMERGENCY LIGHT WAS FOUND INOP. MAINTENANCE RELAMPED. ALL CHECKS GOOD. (M)
- 30 Apr 1997
Bulb, failed
DURING INSPECTION, EMERGENCY LIGHT 2A INOP. MAINTENANCE RELAMPED. ALL CHECKS GOOD. (M)
- 23 Apr 1997
Light, inoperative
DURING INSPECTION, EMERGENCY LIGHT ROWS 6 C AND D FOUND INOPERABLE. MAINTENANCE REPLACED EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOOD. (X)
- 23 Apr 1997
Light, inoperative
DURING INSPECTION, EMERGENCY LIGHT AT ROW 6 FOUND INOPERABLE. MAINTENANCE REPLACED LAMP. ALL CHECKS GOOD. (X)
- 21 Feb 1997
Distributor Vlv, failed
FLT 2974 - AFTER DEPARTING DTW, STABILIZER WARNING DE-ICE WAS SELECTED. CREW RECEIVED MASTER CAUTION AND DE-ICE TIMER LIGHTS ILLUMINATED WITH STABILIZER LIGHT…
- 20 Dec 1996
Ac Generator, failed
DTW - FLT 3032 - CLIMB-OUT FROM DTW, THE RIGHT AC GENERATOR BECAME INOPERATIVE. THE AIRCRAFT RETURNED TO DTW. MAINTENANCE REPLACED THE NR 2 AC GENERATOR. ALL…