N106ML
Raytheon Aircraft Company C90GT FAA →
registration
aircraft radio
1 past record
earlier registrations
1 past record
service difficulty reports
10 reports
- 3 Jul 2007
Downlock Switch, false indication
PILOT REPORTED LT MAIN LANDING GEAR DOWN AND LOCKED INDICATION WITH LANDING GEAR RETRACTED. FOUND SWITCH ASSY INDICATOR SHOWING GREEN DOWN AND LOCKED…
- 30 Apr 2001
Warning Light, illuminated
WHEN LEVELING AT 31,000 FT JAMMED STAB AMBER WARNING ON MFDU. PERFORMED AFCAS TEST IAW AMM 22-11-00, NO FAULTS FOUND. OPERATIONAL CHECK OF FLIGHT CONTROL…
- 17 Oct 2000
Structure, vibration
LOUD VIBRATING NOISE ON TAKEOFF ROLL. PERFORMED HIGH SPEED TAXI AND ENGINE HIGH POWER RUN IAW F-100 AMM 71-00-00, NO FAULTS NOTED. VIBRATION SURVEY PERFORMED…
- 8 Apr 2000
Warning Light, illuminated
FLT 650 RDU/BOS, NR 1 ENG THRUST REVERSER WARNING LIGHT FOR EXTENSION COMES ON AND OFF REPETIVELY DURING CLIMBOUT. ASSIGNED TO DMI NR 07968 PER MEL NR 78-30-1.
- 31 Mar 2000
Filter, clogged
AT FL 350 HYD SYS 1 OVERHEAT FAULT LIGHT ILLUMINATED. RETURNED TO RDU. REMOVED AND REPLACED NR 1 HYDRAULIC SYSTEM RETURN FILTER IAW AMM 29-13-05 AND NR 1…
- 24 Jan 2000
Connector, contaminated
JAMMED STAB . CLEANED SWITCH AND HARNESS CANNON PLUG OPERATIONAL CHECK GOOD AT THIS TIME I-A-W AMM 27-43-04.
- 17 Mar 1999
O Ring, worn
NR 1 HYDRAULIC SYSTEM QUANTITY LOW (FOLLOWED OPS PROCEDURE, ALT LG EXTENSION). FOUND NR 2 ENGINE HYDRAULIC PUMP QUICK DISCONNECT FITTING O-RING WORN…
- 28 Mar 1998
Manifold, failed
RDU - FLT 375 - SYSTEM NR 2 RUDDER FAULTED. REMOVED AND REPLACED RUDDER MANIFOLD IAW F-100 MM 27-22-01, OPS CHECK GOOD. (M)
- 11 Feb 1998
Pla Transmitter, out of adjust
RDU - FLT 931 - ON TAKEOFF ROLL, AUTOTHROTTLES ARMED AND ENGAGED. INSUFFICIENT POWER AND NO AUTOTHROTTLE MOVEMENT. TAKEOFF ABORTED AT APPROX 70 KTS. RDU MX…
- 3 Nov 1995
Hydraulic Pump, leaking
ABE/RDU - FLT 670 - LOW HYDRAULIC QUANTITY SYSTEM 1 DURING FLIGHT. UPON INSPECTION IN RDU FOUND O-RING ON NR 1 SYSTEM RT ENGINE HYDRAULIC PUMP CUT. REPLACED…