N106LN
1999 Eurocopter AS 350 B3 standard FAA →
earlier registrations
1 past record
- 1999
NTSB
- 8 Jun 2013
accident, Grand Prairie TX
- 2 Nov 2004
accident, Sierra Vista AZ
service difficulty reports
12 reports
- 1 Mar 2013
Spar, cracked
TAILROTOR ASSY SPAR CRACKED INTERNALLY. FOUND DURING MX.
- 8 Mar 2011
Ring, drilled
DURING SCHEDULED INSP, AN ATTACHMENT POINT, IT WAS DISCOVERED A PARTIALLY MISDRILLED FASTENER HOLE. THE MFG HAS REVIEWED THIS ANOMALY AND ISSUED FAA FORM…
- 8 Mar 2011
Beam, chafed
DURING SCHEDULED INSPECTION, SEVERAL LOCATIONS ON THE INBD SECTION OF BOTH AFT COMPATMENTS CHAFING WAS DISCOVERED. THE MFG HAS ISSED AN 8110-3 FOR THE REPAIRS…
- 16 Sep 2010
Unknown, odor
CREW REPORTED FUEL ODOR IN COCKPIT, INSPECTED A/F FUEL SYS FOR LEAKS NO LEAKS FOUND IAW MFG, CH 28 INSPECTED ENGINE IAW MFG MM CH 73NO LEAKS FOUND RETURNED…
- 20 Mar 2009
Unknown, odor
AFTER REFUELING, THE ACFT TOOK OFF AND STARTED TO CLIMB OUT, THE MED CREW THOUGHT THAT THEY SMELLED A STRONGER THAN NORMAL ODOR OF FUEL. PILOT SAID THE…
- 30 Sep 2008
Unknown, odor
SHORTLY AFTER TAKEOFF, PERSONNEL ONBOARD REPORTED A BURNING ODOR TO THE PILOT. ABORTED FLT AND RETURNED TO HELIPAD TO INVESTIGATE. MECH PERFORMED AN…
- 13 Sep 2008
Motor, shorted
DEPARTED ON A ROUTINE EMS MISSION, SHORTLY AFTER DEPARTURE, PILOT ABORTED FLT AND RETURNED TO HELIPAD. INFORMED MAINTENANCE OF A STRONG ELECTRICAL ODOR IN…
- 12 Jun 2002
Liner, worn
TEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 7 Jun 2002
Vent Line, cracked
OIL TUBE AIR VENT CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 19 Apr 2002
Display, malfunctioned
VEMD (ASTAR AFTER 3018) DISPLAY PIXELS NOT READABLE IN LOWER SCREEN PORTION. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 27 Feb 2002
Bearing, worn
TAIL ROTOR BEARING ELASTOMERICS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, FROM 1 EACH KIT CORRECTED PROBLEM. 4 HALF SHELLS EQUALS 1KIT.
- 8 Aug 2000
Transmitter, damaged
TORQUE TRANSMITTER LOST ROLL PIN. REPLACED 2 AND 3 MODULES DUE TO TURBINE RUB. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (X)