N10323
1986 Boeing 737-3TO standard FAA →
reservations
earlier registrations
3 past records
- 1986
- 1981
service difficulty reports
59 reports
- 7 May 2009
Downlock Sensor, failed
IN FLIGHT WITH THE LANDING GEAR UP, THE GREEN NOSE GEAR LIGHT WOULD FLASH INTERMITTENTLY. TROUBLESHOT PER M/M 32-61-00, FOUND NLG DOWN LOCK SENSOR RED TO…
- 10 Feb 2009
Charger, inoperative
DURING CHECK OF EMERGENCY LIGHTING, R1 DOOR EMERGENCY EXIT SIGN DID NOT ILLUMINATE. T/S PER WDM 33-51-31 PG 1. FOUND BATTERY CHARGER INOPERATIVE AT STATION…
- 6 Jun 2007
Skin, corroded
INSPECTION FOUND SKIN AT TOP ATC ANTENNA MOUNTING SURFACE CORRODED, STA 420-440, S1L TO 2L. A REPAIR WAS INSTALLED IAW SRM 53-00-01, FIGURE 201. A DIP WAS…
- 3 Jun 2007
Keelbeam, corroded
INSPECTION FOUND RIGHT KEELBEAM CORRODED JUST INSIDE A/C BAY AT STA 537. THE KEELBEAM WAS REPAIRED IAW SRM 53-60-12.
- 2 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 887 BETWEEN STRINGERS 8L AND 9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Skin, corroded
INSPECTION FOUND MOUNTING SKIN SURFACE FOR NR 2 COMM ANTENNA CORRODED AT STA 480-500B, S28L TO S28R. THE SKIN WAS REPAIRED IAW ECRA 5331-01316.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 867, S8L-9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 827 BETWEEN STRINGER 8L AND 9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 747 BETWEEN STRINGER 8L AND 9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 807 BETWEEN STRINGER 8L AND 9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 887 BETWEEN STRINGER 8R AND 9R. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 827 BETWEEN STRINGER 8R AND 9R. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 867 BETWEEN STRINGER 8R AND 9R. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 847 BETWEEN STRINGER 8R AND 9R. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A .25 INCH CRACK IN FUSELAGE FRAME AT STA 480 BETWEEN STRINGER 8L AND 9L. THE FRAME WAS REPAIRED IAW ECRA 5310-04636.
- 1 Jun 2007
Frame, cracked
INSPECTION FOUND A 5 INCH CRACK IN AFT CARGO DOOR CUTOUT FORWARD FRAME AT LOWER DOOR STOP AREA, STA 947.5, S16R-26R. THE FRAME WAS REPLACED IAW SRM 51-40-02…
- 27 May 2007
Frame, corroded
INSPECTION FOUND LOWER O/B CHORD CORRODED AT STA 227, RBL 0 TO LBL 3. REPAIRED IAW ECRA 5311-01324 ITEM 1-16, PAGE 1-3.
- 26 May 2007
Door Frame, cracked
INSPECTION FOUND A .75 INCH CRACK IN FORWARD CARGO DOOR CUTOUT AFT FRAME AT LOWER DOOR STOP FITTING, STA 480-500, S16R TO S28R. THE FRAME WAS REMOVED AND A…
- 25 May 2007
Shear Tie, corroded
INSPECTION FOUND RIGHT NLG WW SHEAR TIE CORRODED AT STA 285. A REPAIR WAS INSTALLED IAW SRM 53-00-07.
- 24 May 2007
Shear Tie, corroded
INSPECTION FOUND RIGHT NLG WW CHORD SHEAR TIE CORRODED AT STA 275, S25R-S26R. A SHEAR TIE FILLER REPAIR WAS INSTALLED IAW SRM 53-00-07.
- 22 May 2007
Frame, corroded
INSPECTION FOUND FRAME CORRODED AT STA 312, S28L. A REPAIR DOUBLER WAS INSTALLED IAW SRM 51-40-02 AND 53-00-07.
- 22 May 2007
Frame, corroded
INSPECTION FOUND FRAME CORRODED AT STA 312, RBL 2, S27R-28R. THE CORRODED AREA WAS CUT OUT AND A REPAIR WAS INSTALLED IAW SRM 53-00-07, FIGURE 201, REPAIR 1.
- 21 May 2007
Stringer, corroded
INSPECTION FOUND STRINGER 28R CORRODED AT STA 325. THE STRINGER WAS REMOVED AND REPLACED IAW SRM 51-20-01 AND 51-70-13.
- 18 May 2007
Frame, cracked
INSPECTION FOUND A 1 INCH CRACK IN LEFT MAIN FRAME AT STA 616, S17L, BELOW MAIN DECK FLOOR. THE FRAME WAS REPAIRED IAW ECRA 5311-01158.
- 15 May 2007
Angle, corroded
INSPECTION FOUND Z-ANGLE AT L-2 DOOR, STA 907-1006, LBL 50 CORRODED. THE Z-ANGLE WAS REPLACED IAW SRM 51-40-02.
- 15 May 2007
Angle, corroded
INSPECTION FOUND Z-ANGLE AT R-2 DOOR ENTRYWAY, STA 947.5-1000, S17R, CORRODED. THE Z-ANGLE WAS REMOVED AND REPLACED IAW SRM 51-40-02.
- 13 May 2007
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 986.5, RBL 43-54. THE CORRODED SECTION OF FLOORBEAM WAS REPLACED IAW SRM 51-40-02.
- 13 May 2007
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT FLOORBOARD MOUNT HOLES, STA 967, S17L TO S17R. REPAIRED FLOORBEAM IAW SRM 53-00-51, FIGURE 201, PAGE 201.
- 9 May 2007
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CORRODED AT STA 328, RBL 32-34. A REPAIR STRAP WAS INSTALLED IAW SRM 53-00-51, FIGURE 201.
- 8 May 2007
Skin, cracked
INSPECTION FOUND A 1.5 INCH CRACK IN FUSELAGE SKIN AROUND L-2 DOOR LOWER HINGE CUTOUT. THE SKIN WAS REPAIRED IAW SRM 53-60-01.
- 28 Apr 2004
Wire, shorted
EMERGENCY LIGHTS INOP AT SEAT ROWS 5-12. REPAIRED SHORTED WIRE UNDER SEAT ROW 5 PER STANDARD PRACTICES MANUAL.
- 21 May 2003
Skin, cracked
INSPECTION FOUND A 1/2 INCH CRACK IN C-2 DOOR INNER SKIN AT ACCESS PANEL CUTOUT BELOW HANDLE. A REPAIR DOUBLER WAS INSTALLED IAW ECRA 5232-01029.
- 21 May 2003
Skin, cracked
INSPECTION FOUND THE AFT CARGO DOOR INNER SKIN CRACKED AT THE EDGE OF A LIGHTENING HOLE. THE DOOR SKIN WAS REPAIRED IAW ECRA 5232-01029.
- 19 May 2003
Skin, cracked
INSPECTION FOUND A .5 INCH CRACK IN C-2 DOOR INNER SKIN ABOVE HANDLE ON LIGHTENING HOLE. THE SKIN WAS REPAIRED IAW ECRA 5232-01015.
- 15 May 2003
Channel, corroded
INSPECTION FOUND U-CHANNEL FOR DRAIN MAST CORRODED AT STA 986.5 BETWEEN S24L AND S25L. INSTALLED DRAIN MAST IAW MM 30-71-00, PAGE 501-503.
- 14 May 2003
Stringer, corroded
INSPECTION FOUND STRINGER 26R CORRODED BETWEEN STA 1006 AND 1016. THE STRINGER WAS REMOVED AND REPLACED IAW SRM 53-01.
- 14 May 2003
Stiffener, corroded
INSPECTION FOUND STIFFENER AFT OF STA 1016, BL 0 CORRODED ON BOTH RIGHT AND LEFT SIDES. LEFT AND RIGHT STIFFENERS AND SPLICES WERE INSTALLED IAW EA 5310-04045…
- 12 May 2003
Bulkhead, corroded
INSPECTION FOUND FORWARD FACE OF AFT PRESSURE BULKHEAD CORRODED JUST AFT OF FS 1016 AT LBL 6 TO RBL 6. REPAIRED APB IAW DRAWING 65C28106-1.
- 12 May 2003
Angle, corroded
INSPECTION FOUND L-2 DOOR ENTRYWAY Z-ANGLE CORRODED AT STA 943-987. A NEW Z-ANGLE WAS INSTALLED IAW SRM 51-40-2.
- 9 May 2003
Floor Support, corroded
INSPECTION FOUND CABIN FLOOR SUPPORT CORRODED AT STA 992-1006, RBL 7. A NEW FLOOR SUPPORT WAS INSTALLED IAW SRM 51-40-02.
- 28 Mar 2003
Skin, damaged
WHILE PERFORMING A PERMANENT REPAIR OF THE LT HORIZONTAL STABILIZER LE SKIN AT LE STA 69.93 IN IAH PER SRM 55-10-01, FIGURE 203, MAINTENANCE NOTED THE…
- 5 Oct 2001
Skin, dented
INSPECTION FOUND L/H HORIZONTAL STABILIZER L/E SKIN DENTED AT STA 147.90. A REPAIR WAS INSTALLED IAW ECRA 5510-01602.
- 4 Oct 2001
Skin, gouged
INSPECTION FOUND R/H RUDDER L/E SKIN GOUGED BELOW ACCESS PANEL 9559. REPAIRED IAW SRM 51-70-17 AND ECRA 5543-01017.
- 3 Oct 2001
Skin, dented
INSPECTION FOUND THE L/H HORIZONTAL STABILIZER FIXED L/E SKIN DENTED AT SECOND RIB FROM I/B. A REPAIR WAS INSTALLED IAW SRM 55-10-01, PAGE 202.
- 2 Oct 2001
Angle, dented
INSPECTION FOUND APU DOOR ANGLE DENTED ON AFT EDGE. A REPAIR DOUBLER WAS INSTALLED IAW SRM 51-70-13.
- 30 Sep 2001
Web, corroded
INSPECTION FOUND WEB CORRODED AROUND FASTENERS AT LOWER SIDE OF C-2 DOOR UPPER THRESHOLD. A NEW WEB WAS INSTALLED IAW SRM 51-10-2.
- 29 Sep 2001
Keelbeam, corroded
INSPECTION FOUND KEEL BEAM CORRODED ON LOWER SURFACE AT STA 705-727, LT SIDE. THE CORROSION WAS REMOVED AND A REPAIR WAS INSTALLED IAW ECRA 5310-03740.
- 15 Jun 2001
Bolt, cracked
INSPECTION FOUND BOTH LT LANDING GEAR DOOR TO STABILIZER BEAM BOLTS PITTED AND CRACKED. THE CRACKS WERE .25 INCH LONG. NEW BOLTS, WASHERS, AND NUTS WERE…
- 15 Jun 2001
Bolt, cracked
INSPECTION FOUND BOTH RT LANDING GEAR DOOR TO STABILIZER BEAM BOLTS PITTED AND ONE BOLT HAD A .25 INCH CRACK. NEW BOLTS, WASHERS, AND NUTS WERE INSTALLED IAW…
- 18 Apr 2001
Warn Panel, faulty
THE CARGO FIRE LIGHT ILLUMINATED WHILE EN ROUTE FROM IAH TO YYZ. NO BELL SOUNDED. THE CARGO FIRE SYSTEM TESTED NORMALLY, BUT THE LIGHT REMAINED ON AFTER TEST.…
- 15 Apr 2000
Wire, broken
THE LT OVERWING EXIT LIGHT WOULD NOT ILLUMINATE DURING OPERATIONAL CHECK PER EAA 3350-01255, STEP 07. A BROKEN WIRE AT THE LIGHT ASSEMBLY WAS REPAIRED IAW…
- 29 May 1999
Floorbeam, corroded
INSPECTION FOUND FLOORBEAM CAP CORRODED AT STA 344, LBL 36 TO RBL 12. A NEW SECTION OF FLOORBEAM AND DOUBLERS WERE INSTALLED IAW SRM 53-10-51.
- 12 Nov 1997
Connector, loose
INSPECTION FOUND EMERGENCY AISLE LIGHT ON ROW 12 INOPERATIVE. THE PLUG CONNECTION FOR ASILE LIGHT WAS RESECURED AND OPERATION CHECKED GOOD.
- 16 Sep 1997
Actuator, leaking
THE B-SYSTEM HYDRAULIC QUANTITY DROPPED TO 3/8 FULL IN FLIGHT. THE NR 2 ENGINE B-PUMP LOW PRESSURE LIGHT ILLUMINATED DURING APPROACH. THE AIRCRAFT LANDED…
- 13 Sep 1997
Logic Card, inoperative
THE RT MLG RED UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. WHEN THE GEAR HANDLE WAS CYCLED FROM OFF TO UP AND THEN BACK TO OFF, BOTH THE RED AND…
- 16 Jun 1997
Channel, corroded
INSPECTION FOUND FLOOR CHANNELS CORRODED AT STA 986 TO 1006 ON LEFT AND RIGHT HAND SIDES. THE CHANNELS WERE REMOVED AND REPLACED IAW SRM 51-40-2.
- 12 Jun 1997
Support, corroded
INSPECTION FOUND TOP EDGE OF FLOOR SUPPORT CORRODED 21 INCHES RIGHT OF CENTERLINE BETWEEN STA 967 AND 986.5. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED…
- 12 Jun 1997
Hat Section, corroded
INSPECTION FOUND TOP EDGE OF HAT SECTION UNDER RIGHT LAV FORWARD WALL AT STA 994 CORRODED. THE HAT SECTION WAS REMOVED AND REPLACED IAW SRM 51-40.
- 13 Nov 1996
Power Supply, inoperative
WHEN GROUND TEST SWITCH FOR EMERGENCY TRACK LIGHTS WAS PLACED IN TEST POSITION FROM COCKPIT OR FLIGHT ATTENDANT POSITION, THE AFT GALLEY AND LAST FOUR CABIN…