- 12 Jan 2004
Skin, cracked
DURING SCHEDULED PMC, FOUND SKIN CRACKED AT BS 757, STRINGER 18R. REPAIRED SKIN CRACK PER SRM.
- 9 Jan 2004
Wire, loose
DURING SCHEDULED PMC, FOUND FWD CABIN OVERHEAD EMERGENCY EXIT LIGHT INOP. RECONNECTED LOOSE WIRES ON OVERHEAD EMERGENCY EXIT LIGHT ASSEMBLY PER MM.
- 13 Nov 2003
Slide, out of position
L2 DOOR EVACUATION SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 10 Sep 2003
Indicator, out of position
DURING SCHEDULED C1 CHECK, FOUND BOTH AFT CABIN DOOR EMERGENCY EVAC SLIDE PRESS INDICATORS OUT OF VIEW. REPOSITIONED SLIDES PER MM.
- 10 Sep 2003
Cover, missing
DURING SCHEDULED C1 CHECK, FOUND SEVERAL EEPLS COVERS MISSING FROM FWD CABIN. INSTALLED COVERS PER MM.
- 16 Aug 2003
Light, inoperative
DURING SCHEDULED PM CHECK, FOUND AFT SVC DOOR EXTERIOR EMERGENCY EXIT LIGHT INOP. RELAMPED EXIT LIGHT PER MM.
- 1 Aug 2003
Clip, loose
FWD SVC DOOR EMERGENCY EVAC SLIDE GIRT BAR ATTACHMENT CLIPS LOOSE. SECURED ATTACHMENT CLIPS PER MM.
- 28 Jul 2003
Indicator, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 22 Jul 2003
Blade, bent
ON POST FLT WALK AROUND NOTICED DEVIATION IN NR 2 ENGINE FAN BLADE. DEVIATION IS 1.25 LONG AND .375 OFF OF STRAIGHT AND LEVEL. REMOVED AND REPLACED C1 FAN…
- 2 Jul 2003
Frame, cracked
DURING SCHEDULED A2 CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 440, STRINGER 24R. REPAIRED FRAME PER BFG ER.
- 2 Jul 2003
Connector, loose
DURING SCHEDULED A2 CHECK, FOUND LT OVERWING EMERGENCY EVACUATION LIGHT INOP. RESEATED EMERGENCY LIGHT BATTERY ASSY CONNECTOR D1494. OPS CK GOOD.
- 30 Jun 2003
Splice, cracked
DURING SCHEDULED SPECIAL VISIT, FOUND STRINGER SPLICE CRACKED AT BS 663, STR 8R. REMOVED AND REPLACED STRINGER SPLICE PER SRM.
- 27 Jun 2003
Stringer Clip, cracked
DURING SCHEDULED SPECIAL VISIT, FOUND STRINGER CLIP CRACKED AT BS 500B, STR 16L. REMOVED AND REPLACED STRINGER CLIP PER SRM.
- 11 Jun 2003
Slide, out of position
DURING SCHEDULED C4 CHECK, FOUND BOTH AFT CABIN DOOR EMERGENCY EVAC SLIDE PRESS IND'S OUT OF VIEW. REPOSITIONED SLIDES PER MM.
- 11 Jun 2003
Slide, out of position
DURING SCHEDULED C4 CHECK, FOUND BOTH AFT CABIN DOOR EMERGENCY EVAC SLIDE PRESS IND'S OUT OF VIEW. REPOSITIONED SLIDES PER MM.
- 11 Jun 2003
Frame, cracked
DURING SCHEDULED C4 CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 800, BETWEEN STR 23R AND STR 24R. REPAIRED FUSELAGE FRAME PER SWA EA.
- 16 Apr 2003
Skin, cracked
DURING WALK AROUND INSP, FOUND FUSELAGE SKIN CRACKS (2 E ) AT BS 912 BELOW STR 24R & BS 940 ABOVE STR 24L. REPAIRED SKIN PER SRM.
- 12 Jan 2003
Engine, stalled
NR 1 ENGINE SUFFERED COMPRESSOR STALL. REMOVED AND REPLACED NR 1 ENGINE, OPS CK GOOD PER MM.
- 18 Oct 2002
Bulkhead, cracked
DURING SCHEDULED C1 CHECK, FOUND BS 1016 PRESS BULKHEAD CRACKED (5 EA) ON WEBS THAT CONVERGE AT THE CENTER OF THE PRESS DOME. REPAIRED BULKHEAD PER SWA EA.
- 15 Oct 2002
Light, inoperative
DURING SCHEDULED C1 CHECK, FOUND AFT SVC DOOR OVERHEAD EMERGENCY EXIT LIGHT INOP. RELAMPED EXIT LIGHT PER MM.
- 15 Oct 2002
Light, inoperative
DURING SCHEDULED C1 CHECK, FOUND EEPLS INOP AT FWD CABIN. RELAMPED PER MM.
- 15 Oct 2002
Cable, misrouted
DURING SCHEDULED C1 CHECK, FOUND FWD ENTRY DOOR EMERGENCY EVAC SLIDE GIRT CABLE MISROUTED. REROUTED CABLE PER MM.
- 18 Aug 2002
Skin, cracked
DURING SCHEDULED SERVICE CHECK, FOUND FUSELAGE SKIN CRACKED AT BS 340, STR 21L. REPAIRED SKIN PER SWA EA.
- 24 Jul 2002
Slide, out of position
FWD ENTRY DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.
- 19 Jul 2002
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 15 Jul 2002
Nut Plate, missing
DURING SCHEDULED RON, FOUND AFT ENTRY DOOR EMERGENCY EVAC SLIDE CONTAINER ATTACH NUT PLATE MISSING. INSTALLED NUT PLATE AND REINSTALLED SLIDE PER MM.
- 20 Jun 2002
Slide, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 16 Jun 2002
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 2 Jun 2002
Slide, out of position
FWD SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 2 Jun 2002
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 30 May 2002
Skin, cracked
DURING SCHEDULED SERVICE CHECK, FOUND FUSELAGE SKIN CRACKED AT BS 903, STR 24R. REPAIRED SKIN PER SRM.
- 1 May 2002
Fitting, cracked
NR 5 L/E SLAT ACTUATOR MOUNT FITTING CRACKED. REMOVED AND REPLACED FITTING PER MM.
- 22 Apr 2002
Slide, out of position
DURING SCHEDULED C3 CHECK, FOUND BOTH AFT CABIN DOOR EMERGENCY EVAC SLIDE PRESS IND'S OUT OF VIEW. REPOSITIONED SLIDES PER MM.
- 13 Apr 2002
Skin, cracked
DURING SCHEDULED A2 CHECK, FOUND FUSELAGE SKIN CRACKED AT BS 947, 2 INCHES BELOW STR 21R. REPAIRED SKIN PER SRM.
- 12 Apr 2002
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE PER MM.
- 28 Feb 2002
Stringer, cracked
DURING SCHEDULED SPECIAL VISIT, FOUND STRINGERS CRACKED AT BS 530, STR 15R AND STR 15L. REPAIRED STR'S PER SRM.
- 26 Feb 2002
Splice, cracked
DURING SCHEDULED SPECIAL VISIT, FOUND STRINGER SPLICE CRACKED AT BS 360, STR 5L. REPAIRED STR SPLICE PER SRM.
- 25 Jan 2002
Skin, cracked
DURING SCHEDULED SERVICE CHECK, FOUND FUSELAGE SKIN CRACKED (4 EA) AT STR 10L, BS 370 TO BS 500B AND (4 EA) AT STR 4L, BS 390 TO BS 812.
- 9 Dec 2001
Stiffener, cracked
DURING SCHEDULED C2 CHECK, FOUND LT WING AILERON BALANCE BAY STIFFENER CRACKED 1.2 INCHES AT SECOND HINGE, WS 574. REPAIRED STIFFENER PER SWA RA.
- 19 Nov 2001
Skin, cracked
DURING WALKAROUND INSP FOUND FUSELAGE SKIN CRACKED AT BS 540A, STR 10L. REPAIRED SKIN PER SWA RA.
- 12 Nov 2001
Light, inoperative
DURING SCHEDULED A2 CHECK, FOUND AFT SVC DOOR EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED EXIT LIGHT PER MM.
- 24 Jun 2001
Slide, out of position
AFT DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EMERGENCY EVAC SLIDE PER MM.
- 30 May 2001
Connector, corroded
(AIR TURNBACK) DURING FLIGHT, 5 MINUTES AFTER APU SHUT DOWN FIRE WARNING LIGHT ILLUMINATED. PERFORMED APU FIRE PROCEDURE AND FIRED BOTTLE. WARNING LIGHT…
- 29 May 2001
Slide, out of position
DURING SCHEDULED C4 CHECK, FOUND AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EMERGENCY EVAC SLIDE PER MM.
- 29 May 2001
Skin, cracked
DURING SCHEDULED C4 CHECK, FOUND FUSELAGE SKIN CRACKED AT BS 942, STR 23R. REPAIRED SKIN PER SRM.
- 12 May 2001
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EMERGENCY EVAC SLIDE PER MM.
- 9 May 2001
Connector, cracked
DECLARED EMERGENCY, DIVERSON AND IN-FLIGHT ENGINE SHUT DOWN. NR 1 ENG FIRE WARNING LIGHT ILLUMINATED IN FLIGHT, ENGINE SHUT DOWN LIGHT RE-ILLUMINATED, FIRE…
- 5 May 2001
Battery Pack, inoperative
DURING SCHEDULED SERVICE CHECK, FOUND WING ROOT OVERWING EMERGENCY EXIT LIGHTS INOP. R&R BATTERY PACK PER MM.
- 4 May 2001
Slide, out of position
AFT ENTRY DOOR EMERGENCY EVAC SLIDE PRES IND OUT OF VIEW. REPOSITIONED EMERGENCY EVAC SLIDE ASSY PER MM.
- 16 Apr 2001
Lens, loose
AFT ENTRY DOOR EMERGENCY EXIT LIGHT LENS COVER LOOSE. SECURED LENS COVER PER MM.
- 15 Apr 2001
Indicator, inoperative
AIR TURNBACK, WX RADAR INDICATOR INOP OUT DURING TAKEOFF. R&R WX RADAR INDICATOR PER MM, OPS CHECK GOOD.
- 14 Apr 2001
Sensor, faulty
AIR TURNBACK, NR 4 KRUGER FLAP IN TRANSIT LIGHT WOULD NOT EXTINGUISH AT FLAPS 10 DEG POSITION. R&R NR 4 KRUGER FLAP DOWN SENSOR PER MM & BAC WDM. OPS CHECK…
- 9 Apr 2001
Transmitter, faulty
AIR TURNBACK, NR1 ENG OIL OVERTEMP INDICATION. SHUT DOWN ENGINE. R&R OIL FILTER, OIL TEMP BULB & PRESSURE TRANSMITTER PER MM. PERFORMED BREATHER PRESSURE…
- 23 Mar 2001
Skin, cracked
DURING WALKAROUND INSPECTION, FOUND EXTERNAL FUSELAGE SKIN CRACKED AT STR 22R, BS 927 & 947.5. REPAIRED SKIN PER SRM.
- 16 Mar 2001
Slide, out of position
AFT ENTRY AND SVC DOOR EMERGENCY EVAC SLIDE PRESS INDICATORS OUT OF VIEW. REPOSITIONED EVAC SLIDE ASSY''S PER MM.
- 28 Feb 2001
Cap, missing
DURING SCHEDULED C3 CHECK, FOUND EEPLS END CAP MISSING AT FWD SECTION. INSTALLED END CAP PER MM.
- 15 Feb 2001
Slide, out of position
AFT SERVICE DOOR EVACUATION SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 25 Jan 2001
Light, loose
AFT ENTRY DOOR EMERGENCY EXIT LIGHT COVER LOOSE. SECURED LIGHT COVER PER MM.
- 11 Jan 2001
Window, cracked
AIR TURNBACK, R1 WINDOW CRACKED DURING T/O. REMOVED AND REPLACED WINDOW PER MM. PRESS AND LEAK CHECK GOOD PER MM.
- 31 Dec 2000
Indicator, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EVAC SLIDE ASSY PER MM.
- 31 Dec 2000
Indicator, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EVAC SLIDE ASSY PER MM.
- 18 Dec 2000
Slide, out of position
AFT SVC & AFT ENTRY DOOR EMERGENCY EVAC SLIDE ASSY PRESS INDICATORS OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 10 Dec 2000
Slide, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. READJUSTED EVAC SLIDE ASSY PER MM.
- 3 Dec 2000
Slide, out of position
AFT SERVICE DOOR EVAC SLIDE PRESSURE INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 29 Nov 2000
Slide, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 29 Nov 2000
Slide, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED EVAC SLIDE ASSY PER MM.
- 27 Nov 2000
Slide, out of adj
DURING SCHEDULED C2 CHECK, FOUND BOTH AFT EMERGENCY EVAC DOORS SLIDE PRESS IND OUT OF VIEW. ADJUSTED SLIDE ASSYS PER MM.
- 7 Nov 2000
Indicator, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 5 Oct 2000
Indicator, out of position
AFT SVC DOOR EMERGENCY EVAC SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY ASSY PER MM.
- 17 Sep 2000
Slide, dislodged
AFT SERVICE DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REPOSITIONED SLIDE PER MM.
- 19 Aug 2000
Bulkhead, cracked
DURING SCHEDULED D-CHECK, FOUND BS 1016 BULKHEAD CRACKED, LBL 30, WL 290. REPAIRED BULKHEAD PER SB.
- 19 Aug 2000
Stringer, corroded
DURING SCHEDULED D-CHECK, FOUND STRINGER 21R CORRODED, BS 903. REPAIRED STRINGER PER SRM.
- 19 Aug 2000
Stringer, corroded
DURING SCHEDULED D-CHECK, FOUND STRINGER 21R CORRODED, BS 903. REPAIRED STRINGER PER SRM.
- 14 Aug 2000
Fitting, corroded
DURING SCHEDULED D-CHECK, FOUND RT HORIZONTAL STAB CENTER SECTION REAR SPAR UPPER AND LOWER AFT LUGS CORRODED. REPAIRED FITTING LUGS PER SRM ACO ER 00-0809.
- 7 Aug 2000
Stringer, cracked
DURING SCHEDULED D-CHECK, FOUND STRINGER 13R CRACKED, BS 807. REPAIRED STRINGER SECTION PER SRM.
- 26 Jul 2000
Shear Tie, corroded
DURING SCHEDULED D-CHECK, FOUND CORROSION DAMAGE AT SHEAR TIE, BS 727A, LBL 1. REPAIRED SHEAR TIE SECTION PER SRM.
- 25 Jul 2000
Stringer Clip, cracked
DURING SCHEDULED D-CHECK, FOUND 2 STRINGER CLIPS CRACKED, BS 597 AND BS 616, STRINGER 4L. REMOVED AND REPLACED CLIPS PER SRM.
- 25 Jul 2000
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND AFT SERVICE DOOR FUSELAGE CUTOUT STUB FRAME CRACKED, BS 954, STRINGER 10R. REMOVED AND REPLACED STUB FRAME PER SRM.
- 25 Jul 2000
Shear Tie, cracked
DURING SCHEDULED D-CHECK, FOUND BS 1121, LBL 30 SHEAR TIE CRACKED. REPAIRED SHEAR TIE SECTION PER SRM.
- 24 Jul 2000
Spar, cracked
DURING SCHEDULED D-CHECK, FOUND RT WING AFT SPAR MOST I/B FASTENER HOLE CRACKED IN UPPER CHORD. REPAIRED PER ER 00-0797.
- 24 Jul 2000
Stringer, cracked
DURING SCHEDULED D-CHECK, FOUND 2 STRINGER SPLICES CRACKED, BS 907, STRINGERS 4L AND 4R. REMOVED AND REPLACED STRINGER SPLICES PER SRM.
- 24 Jul 2000
Stringer, cracked
DURING SCHEDULED D-CHECK, FOUND STRINGER CRACKED, BS 1154, STRINGER 5R. REPAIRED STRINGER SECTION PER SRM.
- 23 Jul 2000
Stringer, corroded
DURING SCHEDULED D-CHECK, FOUND STRINGER 23R CORRODED, BS 907. REMOVED AND REPLACED STRINGER SECTION PER SRM.
- 23 Jul 2000
Stringer Clip, cracked
DURING SCHEDULED D-CHECK, FOUND STRINGER CLIPS CRACKED, BS 727B STR 6L, BS 787 STR 11L, BS 767 STR 7R, BS 807, STR 8R, BS 767 STR 3R, BS 727A STR 2R. REMOVED…
- 23 Jul 2000
Crease Beam, cracked
DURING SCHEDULED D-CHECK, FOUND CREASE BEAM CRACKED AT FASTENER HOLE, BS 178 - BS 188, LBL 31. REMOVED AND REPLACED CREASE BEAM SECTION PER SRM.
- 23 Jul 2000
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND FUSELAGE FRAME CRACKED, BS 189, LBL 31. REPAIRED FRAME SECTION PER SRM.
- 21 Jul 2000
Shear Tie, cracked
DURING SCHEDULED D-CHECK, FOUND SHEAR TIE CRACKED, BS 360, BETWEEN STRINGERS 14R - 15R. REPAIRED SHEAR TIE PER SRM.
- 21 Jul 2000
Stringer Clip, cracked
DURING SCHEDULED D-CHECK, FOUND 7 STRINGER CLIPS CRACKED, BS 727A, STR 7L, STR 7R, STR 10R, BS 727B, STR 8R, BS 767, STR 7L, BS 787, STR 10L, AND BS 827, STR…
- 19 Jul 2000
Stringer Clip, cracked
DURING SCHEDULED D-CHECK, FOUND 5 STRINGER CLIPS CRACKED, BS 727A, STRINGER 14L, BS 727B, STRINGERS 9R, 7R AND 4L, BS 847, STRINGER 10R. REMOVED AND REPLACED…
- 18 Jul 2000
Stringer, cracked
DURING SCHEDULED D-CHECK, FOUND STRINGER 15L CRACKED, BS 360. REMOVED AND REPLACED STRINGER SECTION PER SRM.
- 18 Jul 2000
Stringer, corroded
DURING SCHEDULED D-CHECK, FOUND STRINGER 26R CORRODED, BS 1009. REMOVED AND REPLACED STRINGER SECTION PER SRM.
- 17 Jul 2000
Floorbeam, corroded
DURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORRODED, BS 967, LBL 18, WL 208. REPAIRED BEAM PER SRM.
- 17 Jul 2000
Skin, cracked
DURING SCHEDULED D-CHECK, FOUND AFT SERVICE DOOR UPPER HINGE FUSELAGE SKIN CUTOUT CRACKED. REPAIRED SKIN PER SRM.
- 17 Jul 2000
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND FUSELAGE FRAME SUPPORT CRACKED, BS 332, STRINGER 7R. REMOVED AND REPLACED FRAME SUPPORT SECTION PER SRM.
- 15 Jul 2000
Crease Beam, cracked
DURING SCHEDULED D-CHECK, FOUND I/B CREASE BEAM CRACKED AT TWO PLACES, BS 520, RBL 64. REPAIRED CREASE BEAM PER SRM.
- 15 Jul 2000
Stringer, corroded
DURING SCHEDULED D-CHECK, FOUND CORROSION AT STRINGER 27R, BS 907. REPAIRED STRINGER SECTION PER SRM.
- 15 Jul 2000
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND CRACKED FRAME, BS 807, STRINGER 11R. REPAIRED FRAME PER SRM.
- 15 Jul 2000
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND CRACKED FRAME, BS 616, RBL 64, WL 201. REPAIRED FRAME PER SRM AND TRM.
- 13 Jul 2000
Stiffener, cracked
DURING SCHEDULED D-CHECK, FOUND BS 178 BULKHEAD VERTICAL STIFFENERS CRACKED, LBL 7 AND RBL 17, WL 225. REMOVED AND REPLACED VERTICAL STIFFENERS PER SRM AND ACO.
- 13 Jul 2000
Bulkhead, cracked
DURING SCHEDULED D-CHECK, FOUND BS 178 BULKHEAD CRACKED AT 3 PLACES, LBL 5 TO LBL 12. BULKHEAD WEB REPLACED PER ACO.
- 4 Apr 2000
Skin, cracked
DURING SCHEDULED C4 CHECK, FOUND LT WING UPPER SKIN CRACKED 1.5 INCHES LONG JUST FWD OF REAR SPAR, WS 157. REPAIRED SKIN PER TI 257-014.
- 3 Apr 2000
Light, loose
DURING SCHEDULED C4 CHECK, FOUND FWD EEPLS LOOSE. SECURED LIGHT ASSY PER MM.
- 3 Apr 2000
Indicator, out of position
DURING SCHEDULED C4 CHECK, FOUND AFT ENTRY DOOR EVACUATION SLIDE PRES IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 13 Mar 2000
Indicator, dislodged
AFT SERVICE DOOR EVACUATION SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 17 Feb 2000
Indicator, out of position
AFT SERVICE DOOR EVACUATION SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 10 Feb 2000
Indicator, dislodged
AFT SERVICE DOOR EVACUATION SLIDE PRESS IND OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 3 Feb 2000
Indicator, dislodged
AFT SERVICE DOOR EVACUATION SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 20 Dec 1999
Slide, loose
FWD ENTRY DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. INSTALLED SLIDE ASSY PER MM.
- 22 Nov 1999
Indicator, moved
AFT SERVICE DOOR EVACUATION SLIDE PRESSURE INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 9 Nov 1999
Slide, out of position
AFT SERVICE DOOR EVACUATION SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 28 Oct 1999
Drag Brace, cracked
AIR TURNBACK, UPON GEAR RETRACTION FELT AND HEARD A LOUD BANG BELOW RUDDER PEDALS, FOLLOWED BY A VIBRATION WHICH INCREASED AS AIRSPEED WENT UP. FOUND NLG DRAG…
- 18 Oct 1999
Indicator, out of position
AFT SERVICE DOOR EVACUATION SLIDE PRESS INDICATOR OUT OF VIEW. REPOSITIONED SLIDE ASSY PER MM.
- 18 Aug 1999
Slide, out of position
AFT SERVICE DOOR EVACUATION SLIDE PRESS GAUGE DIFFICULT TO READ. REINSTALLED SLIDE ASSY PER MM.
- 4 Aug 1999
Fire Loop, chafed
DIVERSION IN FLIGHT, ENG SHUT DOWN, NR 2 ENG FIRE WARNING LIGHT ILLUMINATED. ACCOMPLISHED CHECK LIST AND FIRE LIGHT ILLUMINATED AFTER FIRE HANDLE WAS PULLED.…
- 19 Mar 1999
Cover, cracked
DURING SCHEDULED 1/4D CHECK, FOUND EPLS TRACK LIGHTING LENS COVER CRACKED AND BROKEN AT FIRST 6 FEET IN FWD SECTION. REMOVED AND REPLACED PER MM.
- 19 Mar 1999
Web, cracked
NOSE WHEEL WELL, AFT BULKHEAD CRACKED AND RIVET SHEARED AT LT LOWER CORNER, (DUE TO BIRD STRIKE). REPAIRED PER SRM.
- 18 Mar 1999
Skin, corroded
DURING SCHEDULED 1/4D CHECK, FOUND CORROSION ON SKIN AROUND 4 FASTENERS UNDERNEATH DATA PLATE, BS 1020 BETWEEN STR 27L-27R. REPAIRED SKIN PER SRM.
- 17 Mar 1999
Skin, cracked
DURING SCHEDULED 1/4D CHECK, FOUND THROUGH EDDY CURRENT INSPECTION A CRACK INDICATION ON UPPER HINGE CUTOUT ON L-1 DOOR. REPAIRED PER SRM.
- 2 Jan 1999
Connector, dirty
WHEEL WELL FIRE LIGHT CAME ON DURING CLIMBOUT. LOWERED GEAR, LIGHT WENT OUT. AIRCRAFT RETURNED TO DAL AND MADE AN UNEVENTFUL LANDING. CLEANED CONNECTOR D4834P…
- 28 Dec 1998
Battery, discharged
DURING SCHEDULED A1 CHECK, FOUND RT AFT SERVICE DOOR OVERHEAD EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED BATTERY PACK PER BOEING M/M.
- 28 Dec 1998
Battery, discharged
DURING SCHEDULED A1 CHECK, FOUND RT AFT SERVICE DOOR OVERHEAD EMERG EXIT LIGHT INOP. REPLACED BATTERY PACK PER BOEING M/M.
- 11 Dec 1998
Skin, corroded
DURING SCHEDULED C3 CHECK, FOUND AFT LOWER LOBE BS 949 AT S27 HEAVILY CORRODED. REPAIRED PER BOEING SRM.
- 11 Dec 1998
Skin, corroded
DURING SCHEDULED C3 CHECK, FOUND AFT LOWER LOBE BS 972 AT S26R HEAVILY CORRODED NEAR I/B PRESSURE RELIEF VALVE. REPAIRED PER BOEING SRM.
- 29 Oct 1998
Air Dist, odor
FUEL SMELL IN CABIN WITH APU AIR ON. EXAMINED A/C PACK BAY, KEEL BEAM AREA AND A/C DISTRIBUTION BAY, NO FUEL LEAK NOTED. NO FUEL FOUND AT APU FUEL LINE SHROUD…
- 18 Oct 1998
Apu, odor
DURING SCHEDULED RON CHECK, FOUND FUEL SMELL IN CABIN WITH APU AIR ON. CONT PER MEL 49-1. OK FOR GROUND USE ONLY. OK FOR ENGINE START.
- 24 Jun 1998
Skin, cracked
DURING SCHEDULED SERVICE CHECK, FOUND CRACKED SKIN ABOVE BS 767, STR 19R. REPAIRED PER BOEING SRM.
- 31 Dec 1997
Battery, discharged
DURING SCHEDULED SERVICE CHECK, FOUND AFT CABIN AFT UPPER EMERGENCY FLASHLIGHT INOP. REPLACED BATTERY PER BOEING M/M.
- 30 Nov 1997
Acm, malfunctioned
DURING DESCENT, A SMOKE ODOR APPEARED TO BE COMING FROM LEFT PACK BLEED. STOPPED WHEN LEFT BLEED PACK TURNED OFF. LANDED WITHOUT INCIDENT. REPLACED LT AIR…
- 1 Sep 1997
Slide, malfunctioned
DURING SCHEDULED TERMINAL CHECK, FOUND THAT FWD ENTRY SLIDE GIRT BAR WOULDN'T REMAIN IN FLOOR BRACKET. REPLACED SLIDE ASSEMBLY PER BOEING M/M.
- 9 Aug 1997
Stringer, cracked
DURING C1 CHECK, FOUND STRINGER 18A LEFT CRACKED AT FASTENER. REPAIRED PER SWA ACO 6580-53.
- 1 Dec 1996
Fire Light, illuminated
AT TOUCHDOWN, APU FIRE DETECT INOP LIGHT FLICKERED. APU FIRE HANDLE AND BELL ACTIVATED. APU WAS SHUTDOWN. INSPECTED WITH NO EVIDENCE OF FIRE OR OVERHEAT…
- 8 Oct 1996
Frame, cracked
DURING SCHEDULED D-CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 312, LBL 45, WL 283. REPAIRED PER BOEING SRM.
- 8 Oct 1996
Floor Beam, corroded
DURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORROSION AT BS 312, 328, 270, AND 294. REPAIRED PER BOEING SRM.
- 4 Oct 1996
Bulkhead, cracked
DURING SCHEDULED D-CHECK, FOUND BS 178 BULKHEAD CRACKS AROUND FASTENERS, AT WL 234, LBL 10, 11.5, AND 13. REPAIRED PER BOEING SRM.
- 4 Oct 1996
Web, cracked
DURING SCHEDULED D-CHECK, FOUND CRACKS IN WEB AT BS 178 TO 188, WL 234, LBL 10. REPAIRED PER BOEING SRM.
- 4 Oct 1996
Bulkhead Angle, corroded
DURING SCHEDULED D-CHECK, FOUND BULKHEAD SUPPORT ANGLE CORRODED AT BS 520, RBL 26, S26R. REPAIRED PER BOEING SRM.
- 4 Oct 1996
Skin, gouged
DURING SCHEDULED D-CHECK, FOUND FUSELAGE SKIN GOUGED AT BS 818, S15 AND 16R. INSTALLED REPAIR DOUBLER PER BOEING SRM.
- 4 Oct 1996
Skin, dented
DURING SCHEDULED D-CHECK, FOUND FUSELAGE SKIN DENTED AT BS 967, S20L. INSTALLED REPAIR PER BOEING SRM.
- 4 Oct 1996
Skin, dented
DURING SCHEDULED D-CHECK, FOUND FUSELAGE SKIN DENTED AFT OF FWD ENTRY DOOR AT BS 367, ABOVE S17L. REPAIRED PER BOEING SRM.
- 4 Oct 1996
Doubler, cracked
DURING SCHEDULED D-CHECK, FOUND SERVICE DOOR LOWER AFT CORNER STOP FITTING DOUBLER, FRAME TO SKIN CRACKED. REPAIRED PER BOEING SRM.
- 6 May 1996
Skin, cracked
DURING SCHEDULED A1 CHECK, FOUND FUSELAGE SKIN CRACKED AT BS 986.5. REPAIRED PER BOEING SRM.
- 26 Apr 1996
Battery Pack, discharged
DURING SCHEDULED A1 CHECK, FOUND FWD LT AND RT EMERGENCY ESCAPE SLIDE LIGHTS INOP. REPLACED BATTERY PACK PER BOEING M/M.
- 8 Apr 1996
Skin, cracked
DURING SCHEDULED TERMINAL CHECK, FOUND A 3 INCH CRACK, 41 INCHES FWD OF OUTFLOW VALVE AT RIGHT AFT FUSELAGE. REPAIRED PER SWA RA 1-A53-1285.
- 5 Feb 1996
Skin, cracked
DURING SCHEDULED B2 CHECK, FOUND AFT ENTRY DOOR UPPER HINGE CUTOUT ON OUTER SKIN CRACKED IN BOTTOM RADIUS. REPAIRED PER BOEING SRM.
- 15 Oct 1995
Start Valve, failed
DURING CLIMBOUT, NUMBER 1 ENGINE WAS SHUTDOWN DUE TO START VALVE OPEN LIGHT ILLUMINATING. AIRCRAFT RETURNED TO BHM AND MADE AN UNEVENTFUL LANDING. REPLACED…
- 15 Oct 1995
Start Valve, malfunctioned
BHM - DURING CLIMBOUT PASSING 13,000 FT, NUMBER 1 ENGINE START VALVE OPEN LIGHT ILLUMINATED. ALSO, ENGINE OIL TEMP BEGAN INCREASING. CREW PERFORMED ENGINE…
- 10 Feb 1995
Eel Battery, discharged