N102HQ
2007 Embraer-Empresa Brasileira De ERJ 170-200 LR standard FAA →
registration
- 2007
service difficulty reports
112 reports
- 6 Mar 2026
Fitting, damaged
WHILE ON HEAVY CHECK - RH OUTBOARD LOWER PYLON TO WING FITTING OUTBOARD BUSHING MIGRATED.
- 24 Feb 2026
Doubler, corroded
WHILE ON HEAVY CHECK, FOUND THAT THE LT COCKPIT FLOOR DOUBLER HAD CORROSION AND WAS MISSING SURFACE PROTECTION FROM FR 8 - FR 12.
- 22 Feb 2026
Skin, cracked
WHLE ON HEAVY CHECK - RH WING LOWER INTERNAL AND EXTERNAL SKIN WAS FOUND CRACKED AT RIB 12 BETWEEN SPEAR 1 AND STRINGER 18-19. SEEN THROUGH PANEL 631 AB AND…
- 7 Nov 2025
Elec Connector, disconnected
DURING GVI FOUND ELECTRICAL PLUG DISCONNECTED ON 12/13 OHB EMG LIGHT. RECONNECTED OHB EMG LIGHT CANNON PLUG IN ROW CD.
- 5 Jul 2025
Strut, discharged
LG WOW SYS FAIL AFTER RETRACTION. CREW DECLARED EMERGENCY AND LANDED WITHOUT INCIDENT. PERFORMED NLG SERVICING WITH FAULT CLEARED.
- 21 Jun 2025
Warning Message, illuminated
STEER FAIL ON APPROACH. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. PERFORMED STEER FAIL RESET PROCEDURE, FAULT CLEARED.
- 17 Nov 2023
Seal Rest, corroded
DURING HEAVY CHECK MAINTENANCE FOUND FWD CARGO DOOR SURROUND, FWD SEAL REST CORRODED FR24 STR25L. REPLACED CARGO DOOR SURROUND FWD CARGO SEAL REST IAW AMM…
- 7 Nov 2023
Seal Rest, corroded
DURING HEAVY CHECK MAINTENANCE FOUND FWD CARGO DOOR SURROUND, AFT CORNER SEAL REST CORRODED FR27 - STR25L. REPLACED FWD CARGO DOOR SURROUND, FWD SEAL REST IAW…
- 3 Nov 2023
Shear Panel, corroded
DURING HEAVY CHECK MAINTENANCE FOUND CF3 BETWEEN FR87 AND FR88 CENTRE SHEAR PANEL CORRODED. CORRODED SHEAR PANEL BTWN FR 87 FR88 REPLACED IAW ERJ175 SRM 51-42…
- 3 Nov 2023
Floor Support, corroded
DURING HEAVY CHECK MAINTENANCE FOUND CF3 CABIN FLOOR SUPPORT BETWEEN FR88 AND FR 90 RBL 36 CORRODED. CABIN FLOOR SUPPORT REPLACED IAW SRM 51-42-03.
- 3 Nov 2023
Gusset, corroded
CF III FR 90 RBL 25, GUSSET PLATE CORRODED. CF III FR 90, RBL 25, GUSSET PLATE REPLACED IAW SRM 51-41-02.
- 3 Nov 2023
Shear Panel, corroded
DURING HEAVY CHECK MAINTENANCE FOUND CF3 BETWEEN FR87 AND FR88 LH SHEAR PANEL CORRODED. CORRODED SHEAR PANEL BTWN FR 78 FR88 REPLACED IAW ERJ175 SRM 51-42 -01.
- 3 Nov 2023
Rib, cracked
DURING HEAVY CHECK MAINTENANCE FOUND RIB MLG BAY AT FR 45 CRACKED. RIB IN MLG BAY AT FR45 REPAIRED IAW ETD 2023 -170-029313.
- 3 Nov 2023
Seat Track, corroded
R/H INBD. SEAT TRACK, CORRODED UPPER SHEET BTWN. FR85-86. REPLACED IAW ERJ175SRM 51-41-01 & 51-43-01.
- 3 Nov 2023
Shear Panel, corroded
DURING HEAVY CHECK FOUND CFIII, CORODED SHEAR PANEL BTWN. FR 78 & FR 88. REPLACED IAW ERJ 175 SRM 51-42-01.
- 2 Jul 2022
Engine, vibration
ENG 2 LP VIBES AT 4.0. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. THIS WAS ALREADY BEING TRACKED ON A DEFERRAL.
- 17 Mar 2021
Crossbeam, corroded
CORROSION - FR 84 CROSS BEAM SCRATCHED AND CORRODED AS MARKED ALONG ENTIRE LENGTH FROM STR17L TO STR 17R. CUT OUT DAMAGE AREA, FABRICATED ''L'' ANGLES…
- 29 Aug 2020
Battery, inoperative
AISLE EMERGENCY LIGHT OUT. R&R #4 EMERGENCY LIGHT BATTERY REF AMM 33-50-01.
- 10 Jun 2019
Actuator, dirty
R1 DOOR DIFFICULT TO ARM/DISARM. CLEANED DOOR ARMING ACTUATOR IAW AMM 52-11-00.
- 17 May 2019
Door, jammed
JAMMED EMERGENCY EQUIPMENT DOOR IN AFT GALLEY. UNJAMMED EMERGENCY EQUIPMENT DOOR IN AFT GALLEY IAW AMM 25-21-25. OPS CHECK GOOD.
- 19 Oct 2018
Beam, corroded
WHILE IN HEAVY CHECK - CORROSION LOCATED ON L1 DOOR BEAM AS MARKED. REMOVED AND REPLACED L1 DOOR LOWER BEAM. REF SRM 51-40-08.
- 19 Oct 2018
Rib, cracked
WHILE IN HEAVY CHECK - LT HORIZONTAL STABILIZER BETWEEN FRONT AND MIDDLE SPAR FWD OF FRONT STRINGER SUSPECT CRACK AT RIB 11 AS/MARKED. REMOVED AND REPLACED LT…
- 19 Oct 2018
Rib, cracked
WHILE IN HEAVY CHECK - RT HORIZONTAL STABILIZER BETWEEN FRONT SPAR AND MIDDLE SPAR AT RIB 12 HAS CRACK UPPER FLANGE. REMOVED AND REPLACED RIB 12 ON RT…
- 19 Oct 2018
Skin, corroded
WHILE IN HEAVY CHECK - CORROSION, WASTE SERVICE COMPARTMENT CUTOUT SKIN AS MARKED. COMPLY WITH ETD2018-170-102181.
- 19 Oct 2018
Crossbeam, corroded
WHILE IN HEAVY CHECK - CORROSION AT FRAME 17 CROSSBEAM 15" OUTBD OF RT CENTER SEAT TRACK. PERFORMED PERMANENT L-ANGLE REPAIR ON CROSSBEAM FR 17 IN ACCORDANCE…
- 17 Oct 2018
Shear Panel, corroded
CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 CENTER SHEAR PANEL.
- 17 Oct 2018
Shear Plate, corroded
CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT SHEAR PLATE.
- 17 Oct 2018
Splice Plate, corroded
CORROSION CENTER SPLICE PLATE FRAME 90.
- 17 Oct 2018
Gusset, corroded
CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RT CENTER GUSSET FRAME 90.
- 17 Oct 2018
Gusset, corroded
CORROSION RT GUSSET PLATE FRAME 90.
- 17 Oct 2018
Doubler, corroded
CORROSION COCKPIT FLOOR DOUBLER BETWEEN FRAME 11/12.
- 17 Oct 2018
Gusset, corroded
CORROSION- COCKPIT GUSSET AT FR 11 AS MARKED.
- 17 Oct 2018
Seat Track, corroded
CORROSION RT CENTER SEAT TRACK AT FR. 17.
- 17 Oct 2018
Seat Track, corroded
CORROSION AT PREVIOUS REPAIR LT CENTER SEAT TRACK FRAME 19,
- 17 Oct 2018
Floor Support, corroded
CORROSION, FLOOR BOARD SUPPORT FR.87 RBL 27".
- 17 Oct 2018
Upper Sheet, corroded
CORROSION, RT UPPER SHEET AS MARKED FR.85-86.
- 17 Oct 2018
Beam, corroded
CORROSION, RT BEAM AFT. OF UPPER SHEET AT FR. 87.
- 29 Jan 2017
Slide, unsecure
CATERING STATED THAT SLIDE WAS BUMPED WHEN REMOVED A CART AND SLIDE FELL OUT. AIRCRAFT WAS FLOWN VIA MAINTENANCE FERRY TO PIT WHERE MAINTENANCE INSTALLED NEW…
- 28 Dec 2016
Light, missing
CREW REPORTED THAT THE EMERGENCY LIGHT STRIP AT ROW 16 WAS MISSING. MAINTENANCE REPLACED THE LIGHT IAW AMM AND OPS CHECKED GOOD.
- 9 Dec 2016
Light, inoperative
MAINTENANCE REPORTED THAT THE EMERGENCY LIGHT STRIP NEAR SEAT 14 D & F WAS GLOWING. MAINTENANCE ADJUSTED THE LIGHT IAW AMM AND OPS CHECKED GOOD.
- 6 Dec 2016
Seal, dirty
CREW REPORTED VIBRATION FROM THE R2 DOOR FLOOR AREA. MAINTENANCE FOUND DEBRIS, CLEANED SEAL AND PRESSURIZED AIRCRAFT PER EMB AMM AND OPS CHECKED GOOD.
- 13 Sep 2016
Skin, cracked
DURING HEAVY CHECK, THE LT WING LOWER SURFACE SKIN WAS FOUND CRACKED AT RIB 17 AND THE END OF STRINGER 19 AS SEEN INTERNALLY THROUGH ACCESS 531DB. PERFORMED…
- 31 Aug 2016
Seal Rest, corroded
FORWARD CARGO DOOR SEAL REST CORRODED. R & R FORWARD SEAL REST, PN: 170-66803-401 REF SRM 51-23-04, AMM 20-10-01. AIRCRAFT REMAINS IN HEAVY CHECK.
- 30 Aug 2016
Seal Rest, corroded
AFT CARGO DOOR AFT CORNER SEAL REST HAS CORROSION. R & R AFT CARGO AFT CORNER SEAL REST REF SRM 51-40-02 AND AMM 20-10-07. REFER TO ADDITIONAL TASK ENTRIES…
- 28 Aug 2016
Skin, cracked
RT WING LOWER SURFACE SKIN IS CRACKED AT RIB 17 AND THE END OF STRINGER 19 SEEN INTERNALLY PERFORMED TEMPORARY REPAIR OF RT WING SKIN BY CUTOUT AND…
- 26 Aug 2016
Seat Track, corroded
CORROSION AT FRAME 19 INBD SEAT TRACK. REMOVED CORROSION IAW SRM 53-10-10.
- 25 Aug 2016
Door Sill, corroded
DURING HEAVY CHECK, FOUND CORROSION IN RT OTBD SILL AT FRAME 84. INSTALLED NEW FLOOR SILL AT FRAME 84 RT OTBD. RESTORED ORIGINAL FINISH. REF SRM 51-23-04,…
- 25 Aug 2016
Beam, corroded
FORWARD CARGO DOOR CUTOUT HORIZONTAL BEAM HAS CORROSION AS MARKED AT FRAME 27, STR 25R, Z=-1559. R & R FORWARD CARGO AFT FINGER DOUBLER AND APPLIED ALODINE…
- 25 Aug 2016
Seal Rest, corroded
FORWARD CARGO DOOR CENTER SEAL REST CORRODED. R & R CENTER SEAL REST, PN: 170-66804-401, REF SRM 51-40-01. AIRCRAFT REMAINS IN HEAVY CHECK.
- 25 Aug 2016
Gusset, corroded
CORROSION IN CENTER GUSSET, FRAME 90. R & R CENTER GUSSET AT FRAME 90, REF SRM 51-43-03.
- 25 Aug 2016
Beam, corroded
FWD CARGO DOOR CUTOUT HORIZONTAL BEAM HAS CORROSION FRAMES 27 TO 24 NUTPLATES HAVE CORRODED RIVITS STRINGER 25R. REMOVED AND REPLACED THE BEAM IAW SRM…
- 25 Aug 2016
Beam, corroded
FWD CARGO DOOR CUTOUT HORIZONTAL BEAM HAS CORROSION AS MARKED AT FRAME 24 STRINGER 25R. FWD FINGER DOUBLER. REMOVED CORROSION ON FWD CARGO DOOR CUTOUT FWD…
- 29 Apr 2016
Circuit Breaker, tripped
CREW RECEIVED A STEER FAIL MESSAGE. AN EMERGENCY WAS DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE RESET THE STEERING SYS AND PLANE TAXIED TO GATE…
- 28 Oct 2015
Windshield, smoke
CREW REPORTED AN UNUSUAL ODOR AND SMOKE. CREW PUT ON MASKS, DECLARED AN EMERGENCY, DIVERTED, AND LANDED. MAINTENANCE TROUBLESHOT, R & R RT WINDSHIELD IAW AMM…
- 21 Dec 2014
Uplock, corroded
DURING HEAVY CHECK, FWD CARGO DOOR UP LOCK ASSY HAS CORROSION. MAINTENANCE R & R FWD CARGO DOOR UPLOCK ASSY IAW AMM 52-31-24, PN 170-84599-407 LATCH ASSY.
- 20 Dec 2014
Splice, corroded
DURING HEAVY CHECK, LT SHEAR PLATE TO SILL ATTACHMENT DOUBLER BETWEEN FRAMES 87-88 HAS COROSION. MAINTENANCE R & R LT FLOOR SPLICE BETWEEN FRAMES 87-88 IAW…
- 20 Dec 2014
Shear Plate, corroded
DURING HEAVY CHECK, LT SHEAR PLATE BETWEEN FRAMES 87-88 BY OTBD DOUBLER IS CORRODED. MX R & R LT SHEAR PLATE BETWEEN 87-88 BY OTBD DOUBLER IAW SRM 51-42-01,…
- 20 Dec 2014
Plate, corroded
DURING HEAVY CHECK, WAS REPORTED THAT RT PLATE FWD OF R2 DOOR BETWEEN CROSSBEAMS 12 AND 15 IS CORRODED. MX REMOVED AND REPLACED THE RT PLATE IAW SRM 51-40-02,…
- 20 Dec 2014
Plate, corroded
DURING HEAVY CHECK, LT PLATE AFT OF L1 DOOR BETWEEN FRAMES 20-21 IS CORRODED. MAINTENANCE R & R THE PLATE IAW SRM 51-40-02, 51-23-05.
- 19 Dec 2014
Firewall, cracked
DURING HEAVY CHECK, APU FIREWALL HAS TWO CRACKS AT LOWER AND UPPER BENDS. MAINTENANCE REPAIRED THE FIREWALL IAW ETD2014-170-107391. T
- 19 Dec 2014
Rib, cracked
DURING HEAVY CHECK , LT HORIZONTAL STAB L/E RIB FOUND CRACKED. REPAIRED IAW ETD 2014-170-107231.
- 18 Dec 2014
Support Bracket, cracked
DURING HEAVY CHECK, LT PACK DUCT SUPPORT BRACKET IS CRACKED. R & R THE SUPPORT BRACKET IAW SRM 51-41-01AND AMM 20-10-01
- 2 Oct 2014
Light, missing
CREW REPORTED THAT THE EMERGENCY LIGHT WAS MISSING IN FRONT OF SEAT 1D.
- 15 Sep 2014
Unknown, unknown
CREW REPORTED CAPTAIN`S DV WINDOWN HAD A STRONG WIND NOISE AT 100 KNOTS AND MADE A LOUD BANGING NOISE. CREW DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE…
- 25 Jul 2014
Glowstrip, loose
MAINTENANCE REPORTED THAT THE PHOTO LUMINESCENT STRIP AT ROW 1 SLID OUT OF POSITION. MAINTENANCE REPOSITIONED PHOTO LUMINESCENT STRIP IAW EMB AMM AND OPS…
- 19 Jun 2014
Light, missing
CREW REPORTED THAT SECTION OF EMERGENCY LIGHT NEAR SEAT 2A MISSING.
- 15 Jun 2014
Light, loose
CREW REPORTED THAT THE EMERGENCY LIGHT NEXT TO SEAT 1D WAS LOOSE. MAINTENANCE SECURED EMERGENCY LIGHT STRIP IAW AMM AND OPS CHECKED GOOD.
- 24 Mar 2014
Seal, split
CREW REPORTED THAT THE L1 DOOR HAD A WHISTLE. AN EMERGENCY WAS NOT DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND FOUND THE L1 DOOR SEAL…
- 3 Jan 2014
Wire Harness, disconnected
COCKPIT EMERGENCY LIGHT NOT WORKING DURING COCKPIT PREFLIGHT. FOUND HARNESS TO COCKPIT EMERGENCY LIGHT MISSING. FOUND HARNESS AND SECURED IAW AMM 33-50-03.…
- 15 Aug 2013
Flashlight, unknown
CREW REPORTED THAT THE AFT F/A JUMPSEAT FLASHLIGHT WAS INOPERATIVE. MX INSPECTED IAW AMM AND FOUND NO DEFECTS WITH FLASHLIGHT OR CHARGER. OPS CHECKED GOOD.
- 14 Apr 2013
Glowstrip, loose
CREW REPORTED THAT THE PHOTO LUMINESCENT STRIP BY THE FORWARD CLOSET CAME LOOSE. MAINTENANCE RESECURED STRIP PER EMB AMM AND OPS CHECKED GOOD.
- 17 Mar 2013
Indicator, out of adjust
CREW REPORTED THAT THE L1 DOOR LOCK INDICATION WAS NOT WORKING PROPERLY. MAINTENANCE ADJUSTED DOOR LOCK INDICATOR PER EMB AMM 52-11-00. NO DEFECTS NOTED AND…
- 7 Mar 2013
Glowstrip, loose
CREW REPORTED PHOTO LUMINESCENT STRIP IN AISLE AT SEAT 1D IS LOOSE. MAINTENANCE SECURED PHOTO LUMINESCENT STRIP PER EMB AMM 33-50-2 AND OPS CHECKED GOOD.
- 5 Mar 2013
Glowstrip, loose
CREW REPORTED PHOTO LUMINESCENT STRIP AT SEATS 1 D & F IS LOOSE. MAINTENANCE RE-APPLIED PHOTO LUMINESCENT STRIP PER EMB AMM. OPS CHECKED GOOD.
- 4 Mar 2013
Glowstrip, loose
CREW FOUND PHOTO LUMINESCENT STRIP LOOSE AT ROW 1DF. MAINTENANCE RE-SECURED PHOTO LUMINESCENT STRIP PER EMB AMM 33-50-21. OPS CHECKED GOOD.
- 2 Mar 2013
Slide, unlaced
CREW REPORTED L1 DOOR JAMMED AND WILL NOT OPEN. MAINTENANCE INSPECTED AND FOUND THAT L1 DOOR SLIDE LACING CAME LOOSE. MAINTENANCE REMOVED AND REPLACED DOOR…
- 1 Mar 2013
Handle, dirty
CREW DISCOVERED THAT L1 DOOR WOULD NOT OPEN UPON ARRIVAL. MAINTENANCE WAS ABLE TO OPEN THE DOOR WITH SOME DIFFICULTY. MAINTENANCE CLEANED AND LUBED DOOR…
- 4 Jan 2013
Connector, disconnected
CREW REPORTS COCKPIT EMERGENCY LIGHT INOP. MX FOUND THE CONNECTOR NOT CONNECTED TO THE LIGHT ASSY. RE-SECURED CONNECTOR PER EMB AMM. OPS CHECK GOOD.
- 12 Dec 2012
Pin, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE NOSE LANDING GEAR DRAG BRACE MIDDLE PIN (AXLE) INTERNAL THREADS HAVE CORROSION. MAINTENANCE REMOVED…
- 12 Dec 2012
Attach Bracket, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND PANEL 419ML ATTACH BRACKET LEFT PYLON OUTBOARD SIDE CRACKED. MAINTENANCE REMOVED AND REPLACED BRACKET IAW…
- 10 Dec 2012
Mount Bracket, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE UPPER RADAR MOUNT BRACKET CRACKED. MAINTENANCE REMOVED AND REPLACED THE RADAR UPPER MOUNT BRACKET IAW…
- 10 Dec 2012
Support Bracket, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LOWER RADAR SUPPORT BRACKET CRACKED. MAINTENANCE REMOVED AND REPLACED THE LOWER RADAR SUPPORT BRACKET…
- 10 Dec 2012
Attach Angle, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE ATTACH ANGLE FOR RADAR CRACKED. MAINTENANCE REMOVED AND REPLACED ANGLE FOR RADAR ATTACHMENT IAW EMB…
- 10 Dec 2012
Support, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE UPPER RADAR SUPPORT CRACKED. MAINTENANCE REMOVED AND REPLACED THE RADAR UPPER SUPPORT IAW EMB 170 SRM…
- 10 Dec 2012
Support, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE RADAR LOWER SUPPORT CRACKED. MAINTENANCE REMOVED AND REPLACED THE RADAR LOWER SUPPORT IAW EMB 170 SRM…
- 9 Dec 2012
Pin, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE NOSE LANDING GEAR ACTUATOR LOWER ROD END PIN CORRODED. MAINTENANCE REMOVED AND REPLACED NOSE LANDING…
- 9 Dec 2012
Support, gouged
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE NOSE LANDING GEAR ACTUATOR SUPPORT GOUGED FORWARD EDGE INBOARD SIDE. MAINTENANCE BLENDED OUT DAMAGE…
- 8 Dec 2012
Pin, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT MAIN GEAR SIDE STAY LOWER ATTACH PIN CORRODED. MAINTENANCE REMOVED AND REPLACED THE LEFT MAIN…
- 8 Dec 2012
Pin, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE RIGHT MAIN LANDING GEAR SIDESTAY LOWER PIN CORRODED. MAINTENANCE REMOVED AND REPLACED THE RIGHT MAIN…
- 8 Dec 2012
Pin, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT MAIN LANDING GEAR SIDESTAY LOWER ATTACHMENT PIN CORRODED. MAINTENANCE REMOVED AND REPLACED THE…
- 7 Dec 2012
Floorbeam, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT FLOORBEAM CORRODED AT FRAMES 86 TO 87. MAINTENANCE REMOVED AND REPLACED THE LEFT FLOORBEAM AT…
- 7 Dec 2012
Shear Plate, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT SHEAR PLATE BETWEEN FRAME 87 AND 88 CORRODED. MAINTENANCE REMOVED AND REPLACED THE LEFT SHEAR…
- 6 Dec 2012
Bushing, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT ENGINE PYLON FAIRING INBOARD AFT QUICK RELEASE PIN BUSHING CORRODED. MAINTENANCE REMOVED AND…
- 6 Dec 2012
Bushing, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT PYLON AFT FAIRING QUICK RELEASE PIN OUTBOARD AFT BUSHING CORRODED. MAINTENANCE REMOVED AND…
- 6 Dec 2012
Beam, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE RIGHT CENTER FLOOR TRACK BEAM AT FRAME 18 HAS CORROSION. MAINTENANCE REMOVED AND REPLACED THE RIGHT…
- 6 Dec 2012
Floorbeam, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT CENTER FLOORBEAM TRACK AT FRAME 18 CORRODED. MAINTENANCE REMOVED AND REPLACED THE LEFT CENTER…
- 6 Dec 2012
Support, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE SUPPORT FOR THE LEFT RAM AIR VALVE CRACKED. MAINTENANCE REMOVED AND REPLACED THE LEFT RAM AIR VALVE…
- 6 Dec 2012
Profile, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE PROFILE FOR LEFT RAM AIR VALVE CRACKED. MAINTENANCE REMOVED AND REPLACED LEFT RAM AIR PROFILE IAW EMB…
- 6 Dec 2012
Support, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENACE FOUND THE LEFT RAM AIR VALVE SUPPORT CRACKED. MAINTENANCE REMOVED AND REPLACED THE LEFT RAM AIR VALVE SUPPORT IAW…
- 5 Dec 2012
Rib, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT WING SPAR 2 RIB 10 EXTENSION CRACKED. MAINTENANCE REMOVED AND REPLACED THE LEFT WING SPAR 2 RIB…
- 5 Dec 2012
Stop Fitting, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND RUST ON L2 DOOR STOP PADS 3 EACH ON AFT SIDE. MAINTENANCE REMOVED AND REPLACED L2 DOOR STOP PADS 3 EACH ON…
- 30 Sep 2012
Life Vest, damaged
CREW REPORTED 2 INFANT LIFE VESTS DAMAGED. MAINTENANCE REPLACED 2 INFANT LIFE VESTS AS REQUIRED PER EEM CHAPTER 4.
- 28 Nov 2011
Switch, failed
CREW REPORTED PARKING BRAKE NOT REALEASED MSG IN FLIGHT AND THE "ON" LIGHT FOR EMERGENCY BRAKE WAS FLICKERING DURING FLIGHT. DECLARED AN EMERGENCY AND LANDED…
- 2 Jul 2011
Light, inoperative
CREW REPORTED AFT RED RAINBOW LIGHT WOULDN'T ILLUMINATE. MAINTENANCE PLACED ITEM ON MEL 44-13-07-1.
- 28 Jun 2011
Seat Track, corroded
WHILE A/C WAS IN FOR HEAVY CHECK FOUND RT AFT SEAT TRACK HAS CORROSION AT FR 87. MX REPLACED RT SEAT TRACK AT FR 86-89 IAW EMB 175 SRM 51-43-01 NO FCS…
- 25 Jun 2011
Sill, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK, MAINTENANCE REPORTED NUT PLATE HOLDER ATTACH BASE CORRODED ALONG FWD CARGO DOOR SILL. MAINTENANCE REMOVED AND REPLACED NUT…
- 22 Jun 2011
Splice, corroded
*** WHILE AIRCRAFT WAS IN HEAVY CHECK *** LEVEL 2 CORROSION WAS FOUND ON THE RT FLOOR SUPPORT GUSSET AT FR 89. MAINTENANCE REMOVED AND REPLACED THE RT SEAT…
- 22 Jun 2011
Shear Plate, corroded
*** WHILE AIRCRAFT WAS IN FOR HEAVY CHECK *** LEVEL 2 CORROSION WAS FOUND ON SHEAR PLATE AT FRAME 88 & 89. MAINTENANCE REMOVED AND REPLACED THE RIGHT AND…
- 10 Jun 2011
Light, malfunctioned
CREW REPORTED CABIN EMERGENCY LIGHTS ILLUMINATED DURING TAKEOFF AND ON LANDING. MAINTENANCE PERFORMED OPS CHECK OF EMERGENCY LIGHTS PER EMB AMM, OPS CHECK GOOD.
- 10 Jun 2011
Battery, activated
CREW REPORTED EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED FWD RT EMERGENCY BATTERY UNIT PER EMB AMM.
- 26 Oct 2010
Sensor, failed
CREW REPORT SLAT FAIL ON APPROACH, AND DECLARED AN EMERGENCY INTO PHL, AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED BOTH SLAT 3/4 HARNESSES…
- 25 Jul 2010
Power Unit, inoperative
CREW REPORTED EMERGENCY LIGHT AT ROW 190 WAS INOP. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT POWER UNIT PER EMB AMM, THE A/C WAS THEN RETURNED TO…