N101HQ
2007 Embraer-Empresa Brasileira De ERJ 170-200 LR standard FAA →
registration
- 2007
service difficulty reports
74 reports
- 16 Sep 2025
Waste Box, corroded
EVIDENCE OF CORROSION ON WASTE SERICING PANEL CUT OUT INTERNAL SIDE. REMOVED AND REPLACED WASTE BOX DOUBLER. REF: EMB SRM 51-40-08
- 15 Sep 2025
Shear Tie, corroded
CORRODED SHEARCLIP FR78, STGR 27L-28L. FABRICATED, REMOVED AND REPLACED FR 78 STGR27L-28L SHEAR CLIP EMB SRM 51-40-08
- 8 Sep 2025
Skin, cracked
RH WING HAS CRACK ON UNDERSIDE @ RIB 4A SPAR 2 AS MARKED. REPAIRED RH WING CRACK ON UNDERSIDE@ RIB 4A SPAR 2 REF ETD2025-170-928277 REV A.
- 4 Oct 2024
Safety Pin, handler error
LANDING GEAR NO DISPATCH, GEAR WOULD NOT RETRACT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. FOUND NOSE LANDING GEAR SAFETY PIN INSTALLED. REMOVED SAFETY…
- 8 Jun 2024
Display, smoke
DISPLAY UNIT 4 SMELL OF SMOKE. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R DU 4.
- 2 Mar 2023
Unknown, unknown
L2 SLIDE PARTIALLY DEPLOYED. R&R L2 DOOR FLEXBALL CABLE.
- 1 Aug 2022
Shear Panel, corroded
CORRODED SHEAR PANEL FOUND ON FWD FUSE FR12-14 RBL36-49. REPLACED SHEAR PANEL PN 170-05663-005 IAW SRM 51-41-02, 51-43-04.
- 18 May 2021
Connector, disconnected
COCKPIT CEILING EMERGENCY LIGHT INOP. FOUND CONNECTOR DISCONNECTED FROM COCKPIT CEILING EMERGENCY LIGHT ASSY. RECONNECTED.
- 6 May 2021
Shear Tie, corroded
CENTER FUSELAGE III FRAME 90 STRINGER 28L EXTERNAL SKIN SHEAR CLIP HAS CORROSION - MAJOR REPAIR
- 19 Jul 2019
Safety Valve, faulty
CABIN ALTITUDE HIGH EICAS AT 330. ALL PAX MASKS DEPLOYED, NO AURAL INDICATION. CABIN ALTITUDE APPROXIMATELY 8800 AT 320. IN DESCENT, MASKS DEPLOY AUTO.…
- 13 Mar 2019
Arming Lever, obstructed
R1 DOOR ARMING LEVER STIFF. R1 DOOR LEVER HAS BEEN CLEANED AND DEBRIS REMOVED. OPS CHECK GOOD IAW AMM 52-11-00.
- 28 Feb 2019
Actuator, smoke
SMOKEY SMELL IN MID CABIN, FLAP LOW RATE MESSAGE. UPON FURTHER INSPECTION, SMOKE FOUND IN MID E-BAY COMING FROM SF-ACE 2 IAW AMM 27-53-02. OPS CHECK GOOD.
- 16 Jan 2019
Sign, inoperative
***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** AFT ENTRY HOUSING EXIT LOCATOR SING INOP. AFT ENTRY HOUSING LOCATOR SIGN REPLACED AND TESTED SERVICEABLE…
- 14 Jan 2019
Upper Sheet, corroded
WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK. CENTER FUSELAGE III FLOOR STRUCTURE OF PASSENGER CABIN, CORROSION FOUND AT UPPER SHEET BTW FRAME 85-86 RBL 12…
- 14 Jan 2019
Gusset, corroded
WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK. CENTER FUSELAGE III FLOOR STRUCTURE OF PASSENGER CABIN, CORROSION FOUND ON GUSSET PLATE BTW FRAME 85-86 LBL 12…
- 6 Jan 2019
Power Unit, inoperative
WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK. R1 EMERGENCY EXIT IDENTIFIER SIGN INOP. EMERGENCY-LIGHT POWER UNIT NR 1 REPLACED AND TESTED SERVICEABLE IAW AMM…
- 2 Dec 2018
Outflow Valve, inoperative
AT FL380, CREW HEARD A LOUD BANG AND THE SOUND OF RUSHING AIR. CABIN ALT WAS AT 7200 OR 7300 THEN IT STARTED TO CLIMB UP TO 7800 TO 8000 AND MORE. CREW DONNED…
- 5 Jan 2017
Light, migrated
CREW REPORTED THAT THE EMERGENCY LIGHT STRIP AT SEAT 2A HAD MIGRATED BACKWARD. MAINTENANCE ADJUSTED THE LIGHT IAW AMM AND OPS CHECKED GOOD.
- 5 Aug 2016
Stringer, corroded
CORROSION FOUND ON STRINGER 19L, BETWEEN FRAMES 84 - 83. REMOVED AND REPLACED THE STRINGER IAW ETD2016-072634 REV A. MAJOR REPAIR.
- 4 Aug 2016
Shear Panel, corroded
WHILE ACFT WAS IN FOR HEAVY CHECK, FOUND CORROSION ON STR 19R BETWEEN FRAME 83/84. MAINTENANCE INSTALLED NEW SHEAR PANEL AT FRAME 16 LT SIDE PN 170-12118-001…
- 4 Aug 2016
Plate, corroded
WHILE ACFT WAS IN FOR HEAVY CHECK, FOUND CORROSION FRAME 16 LT AFT LAV MOUNTING PLATE. MAINTENANCE R & R LAV MOUNTING PLATE FLOOR SUPPORT, PN 170-13633-001,…
- 4 Aug 2016
Seal Rest, corroded
DURING HEAVY CHECK, FOUND AFT CARGO FWD SEAL REST HAS CORROSION AROUND NUT PLATE, SEAL REST OUT OF LIMITS. REMOVED AND REPLACED THE SEAL REST IAW EMB SRM 175…
- 4 Aug 2016
Shear Panel, corroded
DURING HEAVY CHECK, FOUND CORROSION ON DOUBLER FRAMES 19 - 20. REMOVED AND REPLACED SHEAR PANEL IAW SRM 51-43-02, 51-41-02.
- 4 Aug 2016
Plate, corroded
DURING HEAVY CHECK, FOUND CORROSION AT FRAME 16 LT AFT LAVATORY MOUNTING PLATE. REMOVED AND REPLACED THE LAVATORY MOUNTING PLATE FLOOR SUPPORT, IAW SRM…
- 4 Aug 2016
Stringer, corroded
DURING HEAVY CHECK, FOUND CORROSION ON STRINGER 19R, BETWEEN FRAMES 84 - 83. CUT, REMOVED AND REPLACED SECTION OF THE STRINGER IAW SRM 53-23-03 REPAIR 3,…
- 4 Aug 2016
Mount, corroded
DURING HEAVY CHECK, FOUND FWD WET AREA AFT OF SERVICE DOOR RT WIND SCREEN MOUNT IS CORRODED. REMOVED AND REPLACED THE MOUNT IAW SRM 51-41-02, 51-42-02, AND…
- 4 Aug 2016
Shear Plate, corroded
DURING HEAVY CHECK, FOUND CORROSION ON THE SHEAR PLATE AT FRAMES 13 - 14 ON THE LT SIDE. REMOVED AND REPLACED THE LEFT SHEAR PLATE IAW SRM 51-41-02 AND…
- 3 Aug 2016
Attach Bracket, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK INSPECTION, FOUND CORROSION ON LAV WASTE BOX ATTACH BRACKETS WHICH PROMPTED THE COMPLETION OF SB170-53-0095. MAINTENANCE…
- 3 Aug 2016
Attach Bracket, corroded
WHILE ACFT WAS IN HEAVY CHECK INSPECTION, FOUND CORROSION ON LAV WASTE BOX ATTACH BRACKETS WHICH PROMPTED THE COMPLETION OF SB170-53-0095. MAINTENANCE…
- 6 Mar 2016
Flashlight, inoperative
CREW REPORTED THAT THE F/O FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R THE FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 15 Feb 2016
Anti-Ice Valve, inoperative
CREW RECEIVED AN A/I WING FAIL MESSAGE. CREW RAN QRH, DECLARED AN EMERGENCY AND DIVERTED, WHERE THEY LANDED WITHOUT INCIDENT. MAINTENANCE R & R RT WING A/I…
- 22 Dec 2015
Mechanism, dirty
CREW REPORTED THAT THE L1 DOOR WOULD NOT OPEN. MAINTENANCE FOUND THE DOOR WAS DIRTY INTERNALLY, CLEANED FITTING AND MECHANISM IN DOOR IAW AMM AND OPS CHECKED…
- 6 Sep 2015
Flashlight, inoperative
CREW REPORTED THAT THE AFT GALLEY FLASHLIGHT WAS INOPERATIVE. R & R THE FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 22 Mar 2015
Flashlight, inoperative
CREW REPORTED THAT THE FORWARD F/A FLASHLIGHT WOULD NOT HOLD A CHARGE. MAINTENANCE R & R FORWARD F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 5 Mar 2015
Skin, corroded
WHILE IN HEAVY CHECK, FWD CARGO DOOR UNDER NEATH SCUFF PLATE HAS SPOTS OF CORROSION. MAINTENANCE BLENDED AND COMPLIED WITH ETD 2015-170-02-1897.
- 4 Mar 2015
Beam, corroded
DURING HEAVY CHECK WAS REPORTED THAT LOWER SIDE OF FWD CARGO DOOR AFTDOOR LATCH FITTING IS CORRODED. MX R & R FWD CARGO DOOR BEAM IAW SRM 51-43-02, 51-41-02…
- 4 Mar 2015
Bushing, corroded
DURING HEAVY CHECK, RT SPOILER SECTION NR 1 PCU ATTACH LUG FITTINGS ON SPOILER BUSHINGS APPEAR CORRODED. MAINTENANCE R & R RT SPOILER SECTION NR 1 PCU ATTACH…
- 4 Mar 2015
Nut, corroded
WHILE IN HEAVY CHECK, FWD CARGO DOOR FWD LATCH 3 FITTINGS HARDWARE IS CORRODED. MX R & R FWD CARGO DOOR FWD LATCH 3 FITTINGS HARDWARE IAW 20-10-00.
- 4 Mar 2015
Clamp, corroded
WHILE IN HEAVY CHECK, AFT DRAIN TUBE BONDING JUMPER CLAMP IS CORRODED. MAINTENANCE R & R AFT DRAIN TUBE BONDING JUMPER, CLAMP IAW AMM 53-04-60.
- 3 Mar 2015
Bonding Strap, corroded
DURING HEAVY CHECK , AFT DRAIN FAIRING 4TH POSITION 1 BONDING STRAP CORRODED. MAINTENANCE REPAIRED AFT DRAIN FAIRING 4TH POSITION 1 BONDING STRAP IAW SRM…
- 3 Mar 2015
Seat Track, corroded
DURING HEAVY CHECK, LT CENTER SEAT TRACK AT FRAME 18 CLIP NUT PLATE CORRODED. MAINTENANCE R & R LT CENTER SEAT TRACK IAW SRM 51-40-02, 51-41-01, 51-43-01. PN…
- 3 Mar 2015
Floorbeam, corroded
DURING HEAVY CHECK, FLOOR BRACKET AT FRAME 16 OTBD END AT NUT PLATE HOLE IS CORRODED. MX R & R FASTENERS (2) EACH IAW SRM 51-41-02. AIRCRAFT REMAINS UNTIL…
- 3 Mar 2015
Seat Track, corroded
DURING HEAVY CHECK, RT CENTER SEAT TRACK AT FRAME 17 IS CORRODED. MX R & R RT CENTER SEAT TRACK IAW SRM 51-40-02, 51-41-01. PN 170-03263-001, TRACK. AIRCRAFT…
- 3 Mar 2015
Screw, corroded
DURING HEAVY CHECK, L-2 DOOR ON SLIDE MECHANISM TELEFLEX EYE BOLT IS CORRODED. MAINTENANCE R & R L-2 DOOR ON SLIDE MECHANISM TELEFLEX EYE BOLT IAW AMM…
- 3 Mar 2015
Bolt, corroded
DURING HEAVY CHECK, RT GROUND SPOILER NR 2 TOP PCU BOLT HAS CORROSION. MX R & R RT GROUND SPOILER NR 2 TOP PCU BOLT IAW AMM 27-62-01. PN NAS6212-31D, BOLT.…
- 3 Mar 2015
Dampener, corroded
DURING HEAVY CHECK WAS REPORTED THAT L-2 DOOR DAMPENER THREADS ON CYLINDER HAS CORROSION. MAINTENANCE R & R L-2 DOOR DAMPENER IAW AMM 52-12-27, PN SP-21619A…
- 1 Mar 2015
Access Panel, corroded
DURING HEAVY CHECK WAS REPORTED THAT WASTE DISPOSAL ACCESS PANEL HAS CORROSION. MAINTENANCE R & R WASTE DISPOSAL ACCESS PANEL IAW AMM 20-10-01 APPLIED PRIMER…
- 1 Mar 2015
Bracket, cracked
DURING HEAVY CHECK, LT RAM AIR BRACKET IS CRACKED. MAINTENANCE R & R LT RAM AIR BRACKET, LT RAM AIR FWD VERTICAL BRACKET IAW SRM 51-41-01. PN 170-92988-401,…
- 28 Feb 2015
Structure, corroded
DURING HEAVY CHECK, AFT GALLEY MIDDLE MATTING SURFACE HAS CORROSION. MAINTENANCE REPLACED TRIM PIECES ON AFT GALLEY ON BOTH SURFACES IAW AMM 25-00-23. PN…
- 28 Feb 2015
Bolt, corroded
WHILE IN HEAVY CHECK, FWD LAV LT SIDE AFT FLOOR BOLT IS CORRODED. MAINTENANCE R & R FWD LAV LT SIDE AFT FLOOR BOLT IAW AMM 25-41-02, P/N NAS6205L24, BOLT.…
- 20 Nov 2014
Wire Harness, damaged
CREW RECEIVED NR 2 ENGINE FIRE WARNING MESSAGE. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. ACFT REMAINS OUT OF SERVICE.
- 8 Aug 2014
Unknown, noise
CREW HEARD A LOUD THUMPING NOISE UNDER THE COCKPIT AND FRONT GALLEY. AFTER ACCLERATION THE NOISE BECAME MORE FREQUENT, SLOWING DOWN THE NOISE BECAME LESS…
- 20 Jun 2014
Panel, corroded
FOUND LAVATORY SERVICE PANEL EXTERIOR SIDE LEADING EDGE WITH CORROSION. MX R & R WASTE SERVICE PANEL IAW SRM 51-40-00. PN 170-86668-403, WASTE SERVICE DOOR.
- 15 Mar 2014
Button, missing
CREW REPORTED THAT THE F/A MEGAPHONE VOLUME CONTROL BUTTON WAS MISSING. MAINTENANCE R & R MEGAPHONE IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.
- 8 Nov 2013
Girt Bar, dirty
CREW REPORTED THAT THE L2 DOOR ARMED INDICATION IS ONLY PARTIALLY SHOWING. MAINTENANCE CLEANED GIRT BAR ATTACH POINTS IAW AMM AND OPS CHECKED GOOD. ACFT IS…
- 23 Sep 2013
Girt Bar, out of adjust
CREW REPORTED L2 DOOR WILL NOT DISARM. RESEATED GIRT BAR ON L2 DOOR IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.
- 7 Aug 2013
Megaphone, weak
CREW REPORTED THAT THE AFT F/A MEGAPHONE APPEARS TO BE WEAK. MX R & R AFT MEGAPHONE IAW AMM AND OPS CHECKED GOOD.
- 25 Jun 2013
Flashlight, unsecure
CREW REPORTED THAT THE AFT F/A FLASHLIGHT DOES NOT INDICATE A CHARGE CONSISTENTLY. MX SECURED AFT F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.
- 18 Jun 2013
Slide, defective
FA WAS HAVING TROUBLE CLOSING THE R2 DOOR. MX FOUND THE LACES ON THE SLIDE BAG ARE PULLED AND THE SLIDE IS FALLING OUT OF THE BAG. MX DEPLOYED THE SLIDE SO…
- 13 Apr 2013
Mask, missing
CREW REPORTED THAT THE FORWARD FLIGHT ATTENDANT REQUIRES A DEMO OXYGEN MASK. MAINTENANCE INSTALLED NEW DEMO OXYGEN MASK PER EMB AMM AND OPS CHECKED GOOD.
- 14 Mar 2013
Rib, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT RIB 52 WHEEL WELL FORWARD BULKHEAD CRACKED AT PREVIOUS REPAIR. MAINTENANCE STOP DRILLED CRACK IAW…
- 13 Mar 2013
Attach Bolt, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LOWER EMERGENCY SLIDE ON L2 DOOR ATTACH BOLT CORRODED. MAINTENANCE REMOVED AND REPLACED ATTACH BOLT…
- 13 Mar 2013
Seal Seat, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT CARGO DOOR LOWER SILL SEAL REST CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFT CARGO DOOR…
- 13 Mar 2013
Shaft, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT CARGO DOOR AFT DRIVE ROD SHAFT CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFT CARGO DOOR AFT…
- 12 Mar 2013
Hinge, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LAVATORY SERVICE DOOR HINGE HALF CORRODED. MAINTENANCE REMOVED AND REPLACED THE LAVATORY SERVICE DOOR…
- 12 Mar 2013
Spar, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE RIGHT HORIZONTAL LEADING EDGE SPAR FLANGE CRACKED. MAINTENANCE REPAIRED THE RIGHT HORIZONTAL…
- 11 Dec 2012
Sensor, faulty
CREW REPORTED SLAT FAIL MESSAGE IN FLIGHT. CREW DECLARED EMERGENCY AND RETURNED TO FIELD. MAINTENANCE T/S TO LEFT T1 SKEW SENSOR PER EMB AMM. MAINTENANCE…
- 20 Oct 2012
Light, inoperative
CREW REPORTED THE EMERGENCY LIGHTS ON CABIN CEILING PANEL ARE INOP. MAINTENANCE REPLACED THE LIGHTING ASSEMBLY. PARTS INFORMATION TO BE UPDATED WHEN AVAILABLE.
- 30 Sep 2012
Heat Exchanger, faulty
CREW REPORTED WHILE APPLYING TAKEOFF POWER THEY NOTICED A GAS/CHEMICAL SMELL THAT LASTED THROUGH 3000FT. MAINTENANCE TROUBLESHOT TO A BAD HEAT EXCHANGER.…
- 2 Jun 2012
Doubler, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND DOUBLER ON WATER SERVICE BOX CORRODED. MAINTENANCE REMOVED AND REPLACED THE DOUBLER ON THE WATER SERVICE…
- 2 Jun 2012
Doubler, corroded
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE DOUBLER ON THE WATER SERVICE BOX CORRODED. MAINTENANCE REMOVED AND REPLACED THE DOUBLER ON THE WATER…
- 2 Jun 2012
Rib, cracked
WHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE LEFT WING RIB 10 AT SPAR 2 CRACKED. MAINTENANCE REMOVED AND REPLACED THE RIB 10 AT SPAR 2 ON THE LEFT…
- 8 Aug 2011
Power Unit, failed
MAINTENANCE REPORTED NR 1 EMERGENCY LIGHT POWER UNIT FAILED TEST. MAINTENANCE REMOVED AND REPLACED NR 1 ELPU PER EMB AMM, OPS CHECK GOOD.
- 13 May 2008
Wire Harness, defective
CREW REPORTED SLAT FAIL MESSAGE ON APPROACH. CREW FOLLOWED QRH PROCEDURES AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT AND FOUND SLAT 3/4 HARNESS TO…