N101HN
reservations
service difficulty reports
13 reports
- 12 Jul 2002
Actuator, inoperative
ELECTRO-MECHANICAL ACTUATOR INOPERATIVE. AMBER ON PRIMARY FLIGHT DISPLAY. WOULD NOT PASS PREFLIGHT CHECK. REPLACED WITH NEW UNIT CORRECTED PROBLEM.
- 18 Jun 2002
Actuator, inoperative
SMART ELECTRIC MECHANICAL ACTUATOR, UNIT INOPERATIVE. WILL NOT TEST IN AUTOPILOT MODE. SUSPECT INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 5 Jun 2002
Computer, inoperative
DATA COLLECTION UNIT (DCU). UNIT INOPERATIVE. LOOSES TOTAL COUNT FORWARD AND BACKWARD. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 28 May 2002
Valve, inoperative
BLEED AIR HEAT, INOPERATIVE. REPLACED WITH NEW MIXING VALVE, CORRECTED PROBLEM.
- 22 May 2002
Module, inoperative
AUTO PILOT MODULE INOPERATIVE. YELLOW DIAGONAL SPLASH MARKS ON PFD AND AP2. CIRCUIT BREAKER POPPED. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 16 Apr 2002
Actuator, inoperative
SMART ELEC MECHA ACTUATOR - UNIT INOPERATIVE. POPS CIRCUIT BREAKER. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 12 Apr 2002
Actuator, inoperative
SMART ELEC MECHA ACTUATOR - UNIT INOPERATIVE. PRE-FLIGHT AUTOPILOT CHECK FAILED. DURING FLIGHT PILOT REPORTS AMBER Y ON PFD AND ACTUATOR LIGHT ON CAD.…
- 12 Apr 2002
Valve, inoperative
MIXING VALVE (HEATER/EJECTOR) UNIT INOPERATIVE. VALVE FUNCTIONS PROPERLY, BUT (BLEED AIR) INDICATION CAD ALLWAYS ON REGARDLESS OF HEATING STATUS. REPLACED…
- 9 Apr 2002
Signal Cond Unit, intermittent
SIGNAL PROCESSING UNIT - INTERMITTENT FULL BENDING INDICATION ON START-UP AND WILL STAY AT MAX INDICATION FOR DURATION OF FLIGHT. SOMETIMES UNIT WILL NOT…
- 7 Apr 2002
Module, inoperative
APM2000 AUTO PILOT MODULE - UNIT INOPERATIVE. FAILURE WITH YELLOW BARS ON PFD SHOWN. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 5 Apr 2002
Valve, intermittent
MIXING VALVE (HEATER/EJECTOR) - UNIT OPERATES INTERMITTENTLY. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.
- 3 Apr 2002
Valve, inoperative
MIXING VALVE (HEATER/EJECTOR) - UNIT INOPERATIVE. WILL NOT ALLOW WARM AIR TO COME FROM ENGINE, EVEN THROUGH (BLEED AIR) IS ILLUMINATED ON COCKPIT DISPLAY.…
- 9 Feb 2002
Actuator, intermittent
SMART ELEC MECHA ACTUATOR - INOPERATIVE INDICATION SHOWS ON DISPLAY INTERMITTENLY. INOPERATIVE AUTOPILOT DURING PREFLIGHT CHECK. REPLACED WITH NEW UNIT,…