~/tools/licenses/N983JC
N983JC
aircraft radio
1 past record
service difficulty reports
2 reports
- 11 May 2010
Combust Chamber, cracked
APU START TEMPERATURE HAD INCREASED INTO THE YELLOW AREA ON HOT DAY STARTS AND MAINTENANCE WAS TRENDING THIS FOR ABOUT TWO WEEKS WHEN ON THE FIRST START OF…
- 14 Jan 2010
Tube, failed
TUBE ASSY, PRESSURE OIL TO COOLER, PN 23056413 RUBBING STARTER AIR VALVE CLAMP BURST AT CHAFE RESULTING IN LOSS OF APPROX ONE QUART OF OIL.