N982AS
2023 Air Tractor INC AT-802A restricted FAA →
registration
- 2023
aircraft radio
1 past record
earlier registrations
1 past record
- 1997
service difficulty reports
107 reports
- 18 Dec 2007
Skin, dented
FUSELAGE SKIN DENTED BY JETWAY. REPLACED DAMAGED SECTION OF SKIN. INSTALLED REPAIR DOUBLER PER SRM 53-04-12B.
- 24 Nov 2007
Skin, dented
TWO DENTS ON FUSELAGE SKIN AT STA 235 BETWEEN LEFT L 17 & 18. REPLACED FORMER & REPAIRED SKIN PER SRM 53-04 FIG 12B & EA 5330 02266.
- 17 Aug 2007
Light, inoperative
OVERWING EMERGENCY EXIT LIGHT INOPERATIVE DURING TEST. REPLACED POWER SUPPLY.
- 20 Nov 2006
Floor Panel, delaminated
CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05 DWG 9939195 AND MM 53-20-01.
- 20 Nov 2006
Cusp Web, corroded
CABIN FLOOR CUSP WEB IS CORRODED. REPLACED TWO DAMAGED AREAS OF WEB AND INSTALLED TWO REPAIR DOUBLERS PER SRM 51-70-4.
- 10 Oct 2005
Skin, lightning strike
OKC - DURING HV-CHECK, FOUND FUSELAGE HAS LIGHTNING DAMAGE. REMOVED DAMAGED SECTION. INSTALLED INTERNAL REPAIR DOUBLER. (M)
- 3 Oct 2005
Skin, deteriorated
OKC - DURING HV-CHECK, RIGHT ELEVATOR GEARED TAB INBOARD TRAILING EDGE SKIN IS DETERIORATED. SMOOTHED DETERIORATED AREA AND INSTALLED REPAIR DOUBLER. (M)
- 3 Oct 2005
Seat Track, corroded
OKC - DURING HV CHECK, FOUND PAX CABIN SEAT TRACK IS CORRODED. REPLACED DAMAGED SECTION. INSTALLED PLUG AND CHANNEL. (M)
- 3 Oct 2005
Seat Track, corroded
OKC - DURING HV CHECK, PAX CABIN SEAT TRACK IS CORRODED. REPLACED DAMAGED SECTION. INSTALLED PLUG AND CHANNEL. (M)
- 28 Sep 2005
Tab, delaminated
OKC - DURING HV-CHECK, FOUND RIGHT ELEVATOR GEARED TAB IS DELAMINATED ON LOWER SURFACE AT TRAILING EDGE. REMOVED DAMAGED SECTION. INSTALLED SKIN REPAIR FILLER…
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV-CHECK, PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV C-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, PASSENGER CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV-CHECK, PAX CABIN FLOOR PANEL DELAMINATED. REPLAED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, corroded
OKC - DURING HV CHECK, FOUND PAX CABIN FLOOR PANEL HAS CORRODED INSERTS WITH DELAMINATION AROUND INSERTS. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND PAX CABIN FLOOR PANEL HAS CORRODED INSERTS WITH DELAMINATION AROUND INSERTS. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV CHECK, PAX CABIN FLOOR PANEL HAS CORRODED INSERTS WITH DELAMINATION AROUND INSERTS. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, corroded
OKC - DURING HV-CHECK, PAX CABIN FLOOR PANEL HAS CORRODED INSERTS WITH DELAMINATION AROUND INSERTS. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, PAX CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 26 Sep 2005
Floor Support, corroded
OKC - DURING HV CHECK, FOUND PAX CABIN FLOOR TRACK CORRODED. REPLACED TRACK. (M)
- 26 Sep 2005
Floor Support, corroded
OKC - DURING HV CHECK, PAX CABIN FLOOR TRACK CORRODED. REPLACED TRACK. (M)
- 26 Sep 2005
Web, corroded
OKC - DURING HV CHECK, FOUND PAX CABIN FLOOR WEB CORRODED. REPLACED DAMAGED SECTION. INSTALLED WEB REPAIR AND TWO DOUBLERS. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV-CHECK, PAX CABIN FLOOR PANEL IS DELAMINATED. REPLACED PANEL. (M)
- 26 Sep 2005
Floor Panel, delaminated
OKC - FOUND HV-CHECK, PASSENGER CABIN FLOOR PANEL IS DELAMINATED. REPLACED PANEL. (M)
- 26 Sep 2005
Channel, cracked
OKC - FOUND HV-CHECK, PASSENGER CABIN FLOOR PANEL HAS CRACKED HAT CHANNEL. REPLACED DAMAGED CHANNEL. (M)
- 26 Sep 2005
Intercostal, corroded
OKC - DURING HV-CHECK, FOUND INTERCOSTAL CORRODED. REPLACED INTERCOSTAL. (M)
- 26 Sep 2005
Intercostal, corroded
OKC - FOUND DURING HV-CHECK, INTERCOSTAL CORRODED. REPLACED INTERCOSTAL. (M)
- 26 Sep 2005
Intercostal, corroded
OKC - DURING HV CHECK, FOUND INTERCOSTAL CORRODED. REPLACED INTERCOSTAL. (M)
- 26 Sep 2005
Cusp Web, corroded
OKC - FOUND HV CHECK, CUSP WEB CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER. (M)
- 26 Sep 2005
Frame, corroded
OKC - DURING HV-CHECK, FOUND FRAME CORRODED. REMOVED DAMAGED SECTION. INSTALLED TWO REPAIR DOUBLERS, TWO REPAIR PLATES, AND ONE REPAIR FILLER. (M)
- 26 Sep 2005
Shear Tie, corroded
OKC - DURING HV-CHECK, FOUND SHEAR TIE CORRODED. REPLACED SHEAR TIE. (M)
- 26 Sep 2005
Frame, corroded
OKC - DURING HV-CHECK, FOUND FRAME CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER, TWO REPAIR ANGLES AND TWO REPAIR PLATES. (M)
- 26 Sep 2005
Cusp Web, corroded
OKC - DURING HV CHECK, FOUND CUSP WEB CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER. (M)
- 26 Sep 2005
Shear Tie, corroded
OKC - DURING HV-CHECK, FOUND SHEAR TIE CORRODED. REMOVED DAMGAED SECTION. INSTALLED REPLACEMENT SECTION WITH TWO REPAIR SPLICES. (M)
- 26 Sep 2005
Shear Tie, corroded
OKC - DURING HV CHECK, FOUND SHEAR TIE CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPLACEMENT SECTION WITH TWO REPAIR SPLICES. (M)
- 26 Sep 2005
Shear Tie, corroded
OKC - DURING HV CHECK, FOUND SHEAR TIE CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPLACEMENT SECTION WITH TWO REPAIR SPLICES. (M)
- 26 Sep 2005
Skin, dented
OKC - DURING HV CHECK, FOUND DENT IN FUSELAGE. COLD-FORMED SKIN TO ORIGINAL CONTOUR. INSTALLED INTERNAL REPAIR DOUBLER. (M)
- 26 Sep 2005
Skin, lightning strike
OKC - DURING HV-CHECK, FOUND FUSELAGE HAS LIGHTNING DAMAGE. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND INTERNAL DOUBLER. (M)
- 26 Sep 2005
Doubler, corroded
OKC - DURING HV-CHECK, FOUND ANTENNA DOUBLER CORRODED IN AFT CARGO BAY. REPLACED DOUBLER. (M)
- 26 Sep 2005
Tab, delaminated
OKC - FOUND DURING HV-CHECK, RIGHT ELEVATOR GEAR TAB UPPER SURFACE HAS DELAMINATION. REMOVED DAMAGED SECTION. INSTALLED SKIN FILLER AND REPAIR DOUBLER. (M)
- 26 Sep 2005
Tab, delaminated
OKC - DURING HV CHECK, FOUND RIGHT ELEVATOR ANTI-FLOAT TAB LOWER SURFACE IS DELAMINATED. REMOVED DAMAGED SECTION. INSTALLED SKIN FILLER AND REPAIR DOUBLER. (M)
- 26 Sep 2005
Angle, cracked
OKC - DURING HV CHECK, FOUND VERTICAL STABILIZER TO FUSELAGE LEFT ATTACH ANGLE IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED SKIN FILLER AND REPAIR ANGLE. (M)
- 26 Sep 2005
Wedge, cracked
OKC - DURING HV-CHECK, FOUND RIGHT INBOARD FLAP INBOARD WEDGE TRAILING EDGE IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED VACUUM CURED SPLICE. (M)
- 26 Sep 2005
Panel, gouged
OKC - DURING HV-CHECK, LEFT INBOARD SPOILER PANEL GOUGED ON UPPER SURFACE AT TRAILING EDGE. REPLACED DAMAGED PLIES. (M)
- 20 Nov 2004
Lanyard, disconnected
PRE-FLIGHT CHECK - FWD SERVICE (R-1) DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (K)
- 4 Nov 2004
Power Supply, discharged
SERVICE CHECK- EMERGENCY OVERHEAD CABIN LIGHTS INOPERATIVE AT OVERWING EXIT ON BOTH SIDES. REPLACED ASSOCIATED BATTERY PACKS (POWER SUPPLYS). LIGHT THEN…
- 2 Nov 2004
Skin, cracked
C-CHECK- NLG RT DOOR AFT HINGE COUTOUT IS CRACKED. STOP-DRILLED CRACK. INSTALLED REPAIR DOUBLER IAW SRM.
- 2 Nov 2004
Pan, gouged
C-CHECK - AFT CARGO DOOR LOWER FRAME AND INNER PAN ARE GOUGED ALONG EDGE ADJACENT TO RUB BLOCK. REMOVED DAMAGED AREA. REPAIRED IAW EA.(K)
- 2 Nov 2004
Floor Panel, cracked
C-CHECK - FLIGHT DECK FLOOR PANEL IS CRACKED. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM.(K)
- 20 Oct 2004
Skin, dented
OKC - C-CHECK, FUSELAGE SKIN, STA 218, BETWEEN LONGERON 18L AND 19L IS DENTED X=.042, D=2.20 WITHIN 1 INCH OF STRUCTURE. COLD WORKED SKIN TO CONTOUR,…
- 20 Oct 2004
Skin, dented
OKC - C-CHECK, AFT PIT DOOR FORWARD MID SECTION 12 INCHES FROM TOP IS DENTED D=.920 X=.030. COLD WORKED DENT TO CONTOUR, HFEC COMPLIED WITH, NO DEFECTS NOTED.…
- 20 Oct 2004
Skin, dented
OKC - C-CHECK, AFT PIT DOOR, AFT MID SECTION 3 INCHES FROM EDGE DENTED X=1.10, D=.027, COLD WORKED TO CONTOUR, COMPLIED WITH HFEC. NO DEFECTS NOTED,…
- 20 Oct 2004
Door Frame, corroded
OKC - C-CHECK, AFT CARGO DOOR JAMB LOWER WEB IS CORRODED AT STA 1212 TO STA 1231. REMOVED DAMAGED SECTION OF WEB, ORDERED AND INSTALLED NEW WEB, FABRICATED…
- 20 Oct 2004
Skin, dented
OKC - C-CHECK, MID CARGO DOOR UPPER HAS NUMEROUS DENTS, FWD DENTS, X=.036, D=.800, 13 INCHES AFT OF FORWARD DENT X=.024, D=.800 AND IS OVER PREVIOUS REPAIR.…
- 20 Oct 2004
Skin, gouged
OKC - C-CHECK, FUSELAGE SKIN, STA 237, LONGERON 17L HAS GOUGE WITH DENTS LESS THAN 1 INCH FROM STRUCTURE X=.034, D=1.11. REMOVED DAMAGE, FABRICATED AND…
- 13 Apr 2004
Connector, inoperative
DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE AT ROW 3. RECONNECTED WIRE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)
- 20 Mar 2004
Wire, inoperative
PDX - FOUND TWO EMERGENCY TRACK LIGHT INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED, REPAIRED WIRING, LOOSE CONNECTOR WIRE. LIGHT THEN OPERATED PROPERLY. (M)
- 21 Oct 2003
Lanyard, disconnected
PREFLIGHT CHECK, FOUND FORWARD SERVICE R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 17 Oct 2003
Lanyard, disconnected
PREFLIGHT CHECK, FOUND FORWARD SERVICE R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 13 Sep 2003
Light, inoperative
PDX LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHT WIRING DISCONNECTED AT ROW 30. RECONNECTED WIRING AT ROW 30. LIGHTS THEN OPERATED PROPERLY. (M)
- 5 Sep 2003
Light, inoperative
RNO - PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHT WIRING DISCONNECTED/DAMAGED AT ROW 30. SPLICED WIRING AT ROW 30. LIGHTS THEN OPERATED PROPERLY. (M)
- 19 Dec 2002
Light, inoperative
SEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY, INCLUDING BATTERY PACK. LIGHT THEN…
- 8 Dec 2002
Lanyard, disconnected
SEA - DURING PREFLIGHT CHECK, LANYARD BETWEEN GIRT BAR AND SLIDE COVER WAS FOUND DISCONNECTED. REATTACHED LANYARD. (M)
- 31 Aug 2002
Light, inoperative
SEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY (INCLUDING BATTERY PACK). LIGHT THEN…
- 24 May 2002
Door Frame, corroded
PAE - DURING C-CHECK, FOUND MID CARGO BAY LOWER DOOR BEAM TO BE CORRODED ON VERTICAL FACE AND LOWER HORIZONTAL LUG. REPAIRED PER EA 5310-02090. (M)
- 23 May 2002
Skin, bent
PAE - DURING C-CHECK, FOUND FORWARD PAX ENTRANCE DOOR SKIN BENT ALONG FORWARD BOTTOM EDGE. REPAIRED PER SRM 52-05, FIG 37. (M)
- 20 May 2002
Spacer, corroded
PAE - DURING C-CHECK, FOUND CORROSION ON AFT CARGO BAY THRESHOLD SPACER AT FS 1160-1207. REPAIRED PER EO 5300-0101. (M)
- 30 Mar 2002
Light, out of position
SEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE AT ROWS 6 THROUGH 9. RECONNECTED (REPOSITIONED) LIGHT MODULES. LIGHTS THEN OPERATED…
- 8 Mar 2002
Connector, disconnected
PDX - DURING LINE CHECK, FOUND 5 EMERGENCY TRACK LIGHTS INOPERATIVE, ROWS 6 TO 8. RESECURED ELECTRICAL CONNECTORS. LIGHTS THEN OPERATED PROPERLY. (M)
- 31 Dec 2001
Battery Pack, discharged
SEA - DURING PREFLIGHT CHECK, FOUND COCKPIT OVERHEAD EMERGENCY LIGHTING WAS INOPERATIVE. REPLACED ASSOCIATED BATTERY POWER SUPPLY PACK. LIGHTS THEN OPERATED…
- 15 Dec 2001
Battery Pack, discharged
PDX - DURING LINE CHECK, OVERHEAD EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE BETWEEN ROW 8 AND 17. REPLACED ASSOCIATED BATTERY POWER SUPPLY PACK AT B5-101.…
- 3 Jun 2001
Light, inoperative
PDX - DURING SERVICE CHECK, THE EMERGENCY CEILING LIGHT AT ROW 17 WAS FOUND TO BE INOPERATIVE. REPLACED THE LAMP ASSEMBLY AT ROW 17. THE LIGHTS OPERATED…
- 15 Apr 2001
Lanyard, disconnected
ANC - DURING PRE-FLIGHT CHECK, L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED FROM GIRT BAR. RE-SECURED LANYARD. (M)
- 27 Feb 2001
Girt Bar, inoperative
LAX - DURING PRE-FLIGHT CHECK. L-2 DOOR EMERGENCY SLIDE GIRT BAR WAS FOUND TO BE IMPROPERLY INSTALLED. RE-INSTALLED GIRT BAR PROPERLY. (M)
- 23 Feb 2001
Battery, discharged
PHX - DURING K-CHECK, FOUND LEFT AND RIGHT OVERWING EMERGENCY EXIT OVERHEAD LIGHTS INOPERATIVE. REMOVED AND REPLACED THE TWO BATTERIES IN THE ASSOCIATED…
- 21 Feb 2001
Intercostal, worn
PHX - DURING K-CHECK, FOUND WEAR MARK ON OUTER RADIUS OF TRIANGLE INTERCOSTAL AT FS 1385, LBL 48. FABRICATED AND INSTALLED A DOUBLER REPAIR PER SRM 53-01. (M)
- 20 Feb 2001
Intercostal, corroded
PHX - DURING K-CHECK, FOUND AFT CARGO BAY FRAME TO INTERCOSTAL ANGLE CORRODED AT FS 1155, RBL 3. REMOVED CORRODED ANGLE, FABRICATED AND INSTALLED NEW ANGLE…
- 20 Feb 2001
Doubler, corroded
PHX - DURING K-CHECK, FOUND CLAIRCOM (PAX PHONE) ANTENNA MOUNT INTERNAL DOUBLER, LOCATED IN THE AFT CARGO BAY, CORRODED. REMOVED CORRODED DOUBLER. FABRICATED…
- 19 Feb 2001
Cargo Track, corroded
PHX - DURING K-CHECK, FOUND AFT CARGO BAY CARGO TRACK CORRODED BETWEEN FS 1088 AND 1221, AT BL 15. REMOVED CORRODED TRACK. FABRICATED AND INSTALLED NEW TRACK…
- 16 Feb 2001
Cargo Track, corroded
PHX - DURING K-CHECK, FOUND AFT CARGO BAY CARGO TRACK AND SPLICES CORRODED AT LBL 15, FS 1221-1322. REMOVED AND REPLACED CARGO TRACK AND SPLICES, REF SRM…
- 14 Feb 2001
Intercostal, corroded
PHX - DURING K-CHECK, FOUND AFT CARGO BAY INTERCOSTAL AT FS 1149-1155, RBL 3, CORRODED. REMOVED AND REPLACED INTERCOSTAL, REF DWG 5936071. (M)
- 13 Feb 2001
Cargo Track, corroded
PHX - DURING K-CHECK, FOUND CORROSION ON RIGHT CARGO TRACK AT FS 1212-1322 IN AFT CARGO BAY. REMOVED AND REPLACED CORRODED CARGO TRACK. (M)
- 20 Jan 2001
Battery Pack, discharged
SJC - DURING PREFLIGHT CHECK, OVERHEAD EMERGENCY LIGHTS BETWEEN ROWS 19 AND 22 REMAINED ILLUMINATED WITH ALL POWER AND SWITCHES OFF. REPLACED ASSOCIATED…
- 15 Nov 2000
Battery Pack, discharged
SEA - DURING MAINTENANCE CHECK, BOTH EXTERIOR OVERWING EMERGENCY EXIT LIGHTS WERE DETERMINED TO BE INOPERATIVE. REPLACED BOTH BATTERY PACKS. LIGHTS THEN…
- 9 Oct 2000
Lanyard, disconnected
SEA PRIOR TO FLIGHT 571 THE L1 DOOR SLIDE LANYARD WAS FOUND TO BE DETACHED. RECLIPPED THE L1 DOOR LANYARD.
- 7 Sep 2000
Battery Pack, discharged
SEA - DURING MAINTENANCE CHECK, THE AFT CABIN AND TAILCONE EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. REPLACED THE BATTERY PACK AND THE LIGHTS OPERATED…
- 17 Jul 2000
Wire, broken
ANC - PRIOR TO DEPARTURE OF FLIGHT 190, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHT WIRES AT ROW 24 WERE EXPOSED. REPAIRED BROKEN WIRE IN FLOOR TRACK AT ROW…
- 15 Jul 2000
Battery, discharged
OAK - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE MID AND AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLYS AT…
- 14 Jul 2000
Battery, inoperative
OAK - DURING MAINTENANCE CHECK, THE AFT OVERWING EMERGENCY EXIT IDENTIFIERS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POER SUPPLY AND OPERATED…
- 4 Jul 2000
Battery, discharged
OAK - DURING MAINTENANCE CHECK, THE EMERGENCY LIGHTS IN THE AFT CATWALK AREA, THE AFT CABIN ENTRY DOOR EMERGENCY EXIT IDENTIFER, THE L2 DOOR EMERGENCY EXIT…
- 4 Jul 2000
Battery, discharged
OAK - DURING MAINTENANCE CHECK, THE AFT OVERWING EMERGENCY EXIT IDENTIFIERS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED…
- 24 Dec 1999
Wire, disconnected
SEA - AFTER ARRIVAL OF FLIGHT 557, CRWE REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE.. RECONNECTED WIRING IN FLOOR TRACK…
- 22 Dec 1999
Wire, failed
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 13 TO 15 WERE FOUND INOPERATIVE. REPLACED WIRING IN FLOOR TRACK AND OPERATED…
- 6 Sep 1999
Hook, damaged
SEA - FLT 94 - PRIOR TO DEPARTURE, CREW REPORTED THE L1 DOOR WOULD NOT CLOSE, DOOR RESTING ON JETWAY. STRAIGHTENED LOWER RT CORNER OF DOOR AND STRAIGHTENED…
- 6 Jan 1999
Light, defective
SEA - DURING MAINTENANCE CHECK THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. PART TC: 14,132.…
- 1 Jan 1999
Power Supply, inoperative
SEA - DURING MAINTENANCE CHECK, THE AFT OVERWING EMERGENCY EXIT IDENTIFIERS FLASH WHEN THE AUXILIARY HYDRAULIC PUMP IS SWITCHED ON. REPLACED THE POWER SUPPLY…
- 30 Nov 1998
Portable Light, inoperative
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 30 Oct 1998
Light, inop
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 29 May 1998
Skin, bird strike
SEA - DURING APPROACH OF FLT 537, CREW REPORTED STRIKING AN EAGLE ON THE FORWARD FUSELAGE AREA AT 3,000 FEET MSL. FOUND DAMAGE CONTAINED WITHIN THE…
- 29 Aug 1997
Switch, malfunctioned
SEA - AFTER ARRIVAL OF FLT 379, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS ILLUMINATE INTERMITTENTLY DURING FLIGHT. ACCOMPLISHED OPERATIONAL CHECK OF…