N981AS
1997 McDonnell Douglas Aircraft Co MD 83 standard FAA →
aircraft radio
1 past record
earlier registrations
1 past record
- 1997
service difficulty reports
107 reports
- 25 Oct 2016
Drag Angle, cracked
DURING C CHECK. PAX DOOR AFT DRAG ANGLE WAS FOUND CRACKED. COMPLIED WITH ECTC REO 601R-52-11-513.
- 20 Sep 2006
Handle, stiff
FOUND AFT CABIN DOOR HANDLE VERY HARD TO MOVE. LUBED DOOR HANDLE LOCKPINS. OP CHECKS NORMAL.
- 15 Sep 2006
Skin, dented
FOUND FUSELAGE DENTED. REMOVED TEMP REPAIR DOUBLER. INSTALLED REPAIR DOUBLER FILLER AND FINGER DOUBLER PER SRM 53 04.
- 13 Sep 2006
Floor Panel, delaminated
CABIN FLOOR PANEL DELAMINATED. REPLACED PANEL PER SRM 53-05.
- 5 Sep 2006
Skin, dented
FUSELAGE DENTED AFT OF FORWARD CARGO BAY. REMOVED DAMAGED SECTION ON SKIN. INSTALLED EXTERNAL DOUBLER PER SRM 53-04.
- 19 Oct 2005
Skin, dented
SEA - LINE CHECK, L-1 FWD PAX DOOR DENTED. REPAIRED PER SRM 53-04. (M)
- 17 Oct 2005
Structure, dented
SEA - LINE CHECK, L-1 FORWARD PAX DOOR DAMAGED/DENTED. REPAIRED PER SRM 53-04. (M)
- 21 Jun 2005
Shear Tie, corroded
OKC - DURING HV-CHECK, FOUND SHEAR TIE CORRODED. REPLACED SHEAR TIE. (M)
- 21 Jun 2005
Shear Tie, corroded
OKC - DURING HV-CHECK, FOUND SHEAR TIE CORRODED. REPLACED SHEAR TIE. (M)
- 21 Jun 2005
Intercostal, corroded
OKC - DURING HV-CHECK, FOUND INTERCOSTAL CORRODED. REPLACED INTERCOSTAL. (M)
- 21 Jun 2005
Cusp Web, corroded
OKC - DURING HV-CHECK, LEFT CUSP WEB IS CORRODED ON UPPER SURFACE. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER. (M)
- 21 Jun 2005
Skin, dented
OKC - DURING HV-CHECK, FOUND FUSELAGE SKIN DENTED AND CREASED. REMOVED DAMAGED SECTION. INSTALLED SKIN REPAIR SECTION, FINGER DOUBLER, LONGERON STRAPS,…
- 21 Jun 2005
Skin, delaminated
OKC - DURING HV-CHECK, FOUND LEFT ELEVATOR GEARED TAB UPPER INBOARD SURFACE IS DELAMINATED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER. (M)
- 21 Jun 2005
Structure, dented
OKC - DURING HV-CHECK, FOUND RIGHT ELEVATOR GEARED TAB LOWER INBOARD SURFACE IS DENTED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER. (M)
- 21 Jun 2005
Vane, punctured
OKC - DURING HV-CHECK, FOUND LEFT INBOARD FLAP INBOARD FLAP VANE PUNCTURED AND DELAMINATED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - FOUND HV CHECK, CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, corroded
OKC - DURING HV-CHECK, CABIN FLOOR PANEL INSERTS CORRODED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - FOUND HV CHECK, CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, corroded
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED AND CORRODED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL TORN AND DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, delaminated
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Panel, broken
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL BROKEN. REPLACED FLOOR PANEL. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - FOUND DURING HV-CHECK, CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - FOUND DURING HV CHECK, CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, FOUND CABIN FLOOR SUPPORT CORRODED AROUND INSERT. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Floor Support, corroded
OKC - DURING HV-CHECK, FOUND CABIN FLOOR PANEL SUPPORT CORRODED AROUND INSERT. REPLACED FLOOR PANEL SUPPORT. (M)
- 13 Jun 2005
Web, corroded
OKC - DURING HV CHECK, FOUND AFT CARGO BAY DOOR JAMB LOWER TORQUE BOX WEB CORRODED. REPLACED WEB. (M)
- 13 Jun 2005
Beam, corroded
OKC - DURING HV CHECK, FOUND AFT CARGO BAY DOOR JAMB LOWER BEAM CORRODED. REPLACED BEAM. (M)
- 13 Jun 2005
Longeron, corroded
OKC - FOUND HV-CHECK, LONGERON 30 CORRODED. REPLACED DAMAGED SECTION. (M)
- 13 Jun 2005
Shear Tie, corroded
OKC - DURING HV CHECK, AFT CARGO BAY SHEAR TIE CORRODED. REPLACED DAMAGED SHEAR TIE. (M)
- 13 Jun 2005
Intercostal, cracked
OKC - DURING HV CHECK, FOUND L1 DOOR INTERCOSTAL CRACKED. REPLACED DAMAGED INTERCOSTAL. (M)
- 13 Jun 2005
Intercostal, cracked
OKC - DURING HV CHECK, CABIN FLOOR INTERCOSTAL CRACKED. REPLACED DAMAGED INTERCOSTAL. (M)
- 13 Jun 2005
Shear Tie, corroded
OKC - FOUND DURING HV CHECK, AFT CARGO BAY SHEAR TIE CORRODED. REPLACED DAMAGED SHEAR TIE. (M)
- 13 Jun 2005
Longeron, cracked
OKC - DURING HV CHECK, FOUND LONGERON 2L CRACKED. REPLACED DAMAGED SECTION OF LONGERON. (M)
- 13 Jun 2005
Longeron, cracked
OKC - FOUND DURING HV CHECK, LONGERON 2R CRACKED. REPLACED DAMAGED SECTION OF LONGERON. (M)
- 13 Jun 2005
Intercostal, corroded
OKC - DURING HV CHECK, FOUND INTERCOSTAL CORRODED. REPLACED DAMAGED INTERCOSTAL. (M)
- 13 Jun 2005
Shear Tie, corroded
OKC - FOUND DURING HV CHECK, SHEAR TIE CORRODED. REPLACED DAMAGED SHEAR TIE. (M)
- 13 Jun 2005
Shear Tie, corroded
OKC - DURING HV CHECK, FOUND SHEAR TIE CORRODED. REPLACED DAMAGED SHEAR TIE. (M)
- 13 Jun 2005
Strap, corroded
OKC - DURING HV CHECK, AFT CARGO BAY STRAP BETWEEN FRAMES 1136 AND 1155 CORRODED. REPLACED DAMAGED STRAP. (M)
- 13 Jun 2005
Shear Tie, corroded
OKC - DURING HV CHECK, FOUND SHEAR TIE CORRODED. REPLACED DAMAGED SHEAR TIE. (M)
- 13 Jun 2005
Frame, corroded
OKC - FOUND DURING HV CHECK, AFT CARGO BAY FRAME CORROSION. REPLACED DAMAGED FRAME. (M)
- 13 Jun 2005
Seat Track, gouged
OKC - HV-CHECK, FOUND SEAT TRACK GOUGED. REPLACED DAMAGED SEAT TRACK SECTION. (M)
- 13 Jun 2005
Seat Track, corroded
OKC - DURING HV-CHECK, FOUND SEAT TRACK CORRODED. REPLACED DAMAGED SEAT TRACK SECTION. (M)
- 13 Jun 2005
Track, corroded
OKC - DURING HV CHECK, CABIN FLOOR FALSE TRACK CORRODED. REPLACED FALSE TRACK. (M)
- 13 Jun 2005
Track, corroded
OKC - DURING HV CHECK, FOUND CABIN FLOOR FALSE TRACK CORRODED. REPLACED FLASE TRACK. (M)
- 13 Jun 2005
Skin, dented
OKC - DURING HV-CHECK, FUSELAGE SKIN DENTED. INSTALLED REPAIR DOUBLER. (M)
- 13 Jun 2005
Skin, dented
OKC - DURING HV CHECK, AFT CARGO BAY DOOR SKIN DENTED. RECONTOURED SKIN AND INSTALLED REPAIR DOUBLER. (M)
- 12 Jun 2005
Floor Panel, corroded
OKC - DURING HV-CHECK, CABIN FLOOR PANEL CORRODED. REPLACED FLOOR PANEL. (M)
- 29 May 2004
Door Frame, cracked
OKC - DURING C-CHECK, FOUND NLG CUTOUT LONGITUDINAL FRAME IS CRACKED ON LEFT SIDE AT TOP FASTENER HOLE. STOP DRILLED AND INSTALLED REPAIR ANGLE AND SHIM PER…
- 29 May 2004
Door Frame, cracked
OKC - DURING C-CHECK, FOUND NLG CUTOUT LONGITUDINAL FRAME IS CRACKED ON RIGHT SIDE AT TOP FASTENER HOLE. STOP DRILLED AND INSTALLED REPAIR ANGLE AND SHIM PER…
- 29 May 2004
Skin, dented
OKC - DURING C-CHECK, FUSELAGE SKIN IS DENTED ON LEFT SIDE NEAR VERTICAL STABILIZER. REMOVED DAMAGED SECTION AND INSTALLED REPAIR DOUBLER PER SRM 53-01. (M)
- 13 May 2004
Power Supply, inoperative
LAX - FOUND EMERGENCY TRACK LIGHTS INOPERATIVE AT ROW 31. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)
- 1 Jan 2004
Lanyard, disconnected
LAS - DURING PREFLIGHT CHECK, FOUND AFT SERVICE L2 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 25 Oct 2003
Battery Pack, discharged
SAN PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS FLASH INTERMITTENTLY IN 1ST CLASS CABIN. REPLACED BATTERY PACK ABOVE SEAT 2E. LIGHTS THEN OPERATED…
- 24 Oct 2003
Connector, loose
PDX PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS FLASH INTERMITTENTLY IN 1ST CLASS CABIN. SECURED LOOSE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)
- 26 Aug 2003
Connector, loose
LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 13-16. RECONNECTED LOOSE CONNECTION. LIGHTS THEN OPERATED PROPERLY. (M)
- 20 Jul 2003
Lanyard, disconnected
PREFLIGHT CHECK, AFT SERVICE L-2 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 19 May 2003
Blade, failed
ON TAKEOFF ROLL FROM MZT, NR 2 ENGINE VIBRATION OCCURRED ABORTED TAKEOFF AND RETURNED TO THE GATE SUBSEQUENT ENGINE CHANGE INITIATED. A LOUD BANG AND…
- 11 Apr 2003
Lanyard, disconnected
SEA PREFLIGHT CHECK, FOUND LEFT AFT SERVICE (L-2) DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 6 Apr 2003
Connector, unsecure
SJC - DURING PREFLIGHT, FOUND PORTION OF EMERGENCY TRACK LIGHTS INOPERATIVE. SECURED EMERGENCY TRACK LIGHT CONNECTOR. LIGHTS THEN OPERATED NORMALLY. (M)
- 27 Jan 2003
Door, out of rig
SEA - DURING PREFLIGHT CHECK, FOUND COCKPIT DOOR COULD NOT BE OPENED. RE-RIGGED DOOR TO INCREASE CLEARANCES, WAS BINDING AT LOWER LEFT CORNER. DOOR THEN…
- 1 Nov 2002
Connector, disconnected
SEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED LOOSE CONNECTION. LIGHTS THEN OPERATED PROPERLY. (M)
- 26 Aug 2002
Light, inoperative
SEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED PORTABLE LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)
- 13 Aug 2002
Battery, failed
LAX - JUST PRIOR TO PUSH BACK, SMOKE WAS NOTED DISCHARGING FROM VENT HOLES AFT OF THE NLG WHEEL WELL. THE SMOKE WAS DETERMINED TO BE STEAM DISCHARGING FROM…
- 15 Jun 2002
Connector, loose
LAS - DURING PREFLIGHT CHECK, EMERGENCY TRACK LIGHTING IN AFT CABIN WAS FOUND TO BE INOPERATIVE. RECONNECTED LOOSE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)
- 16 May 2002
Module, disconnected
PDX - DURING LINE CHECK, DISCOVERED EMERGENCY TRACK LIGHTS AT ROW 10-15 WERE INOPERATIVE. RECONNECTED LAMP HOLDER MODULE. LIGHTS THEN OPERATED PROPERLY. (M)
- 2 Apr 2002
Lanyard, detached
PHX - DURING PREFLIGHT CHECK, L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)
- 2 Nov 2001
Lanyard, disconnected
LAX - DURING PREFLIGHT CHECK, THE TAILCONE SLIDE LANYARD WAS FOUND DISCONNECTED. THE LANYARD WAS RE-ATTACHED. (M)
- 16 Feb 2001
Light, damaged
SEA - DURING LINE CHECK, SEVERAL EMERGENCY LIGHT ASSEMBLIES IN THE TAILCONE AREA WERE FOUND TO BE DAMAGED. REMOVED AND REPLACED DAMAGED LIGHT ASSEMBLIES.…
- 11 Feb 2001
Light, damaged
SEA - DURING LINE CHECK, TWO OF SIX EXIT IDENTIFIER LIGHT ASSEMBLIES IN THE TAILCONE WERE DETERMINED TO BE DAMAGED. REPLACED THE L2-849 AND L2-850 EXIT…
- 28 Jan 2001
Hydraulic Line, leaking
PVR - DURING GEAR RETRACTION, RIGHT HYDRAULIC SYSTEM PRESSURE AND QUANTITY WENT TO ZERO. USED ALTERNATE GER EXTENSION TO LOWER GEAR FOR LANDING. RUDDER PCU…
- 24 Jan 2001
Cargo Track, corroded
PHX - DURING K-CHECK, AFT CARGO BAY TIE DOWN TRACK AT FS 1231-1287, WAS FOUND TO BE CORRODED. REMOVED AND REPLACED TRACK AIW SRM 51-30-2. (M)
- 24 Jan 2001
Shear Tie, corroded
PHX - DURING K-CHECK, AFT CARGO BAY SHEAR TIE AT FS 1250, LONGERON 28L-28R, WAS FOUND TO BE CORRODED. REMOVED AND REPLACED WITH NEWLY FABRICATED SHEAR TIE IAW…
- 24 Jan 2001
Cargo Track, corroded
PHX - DURING K-CHECK, AFT CARGO BAY LEFT CARGO TRACK SPLICES AT FS 1220 WERE FOUND TO BE CORRODED. REMOVED AND REPLACED SPLICES (P/N''S 5936660-91, 93, 95,…
- 24 Jan 2001
Seat Track, corroded
PHX - DURING K-CHECK, CABIN SEAT TRACK AT FS 246, 22 INCHES FROM RBL, WAS FOUND TO BE CORRODED. REPAIRED SEAT TRACK WITH SPLICE REPAIR IAW SRM 53-05, FIG 4F.…
- 24 Jan 2001
Frame, corroded
PHX - DURING K-CHECK, MID CARGO BAY LOWER AFT FRAME AT FS 522, FROM LONGERON 28R TO 28L, WAS FOUND TO BE HEAVILY CORRODED. REPLACED CORRODED SECTION USING…
- 23 Jan 2001
Longeron, corroded
PHX - DURING K-CHECK, FOUND LONGERON 30, IN MID CARGO BAY AT FS 579, WAS FOUND TO BE CORRODED AT FASTENERS COMMON TO FUSELAGE SKIN. FABRICATED AND INSTALLED…
- 23 Jan 2001
Battery, discharged
PHX - DURING K-CHECK, AFT SERVICE DOOR EMERGENCY SLIDE LIGHTING HARNESS BATTERY WAS DETERMINED TO HAVE LOW VOLTAGE. REPLACED COMPLETE SLIDE ASSEMBLY.…
- 22 Jan 2001
Frame, corroded
PHX - DURING K-CHECK, AFT CARGO BAY FRAME AT FS 1250, LONGERON 29L-28R, WAS FOUND TO BE CORRODED. FABRICATED AND INSTALLED NEW FRAME SECTINO AND SPLICES. (M)
- 22 Jan 2001
Cargo Track, corroded
PHX - DURING K-CHECK, AFT CARGO BAY TIE-DOWN TRACK AT FS 1090-1220, STRINGER 27L, WAS FOUND TO BE CORRODED. FABRICATED AND INSTALLED NEW CARGO TIE-DOWN TRACK.…
- 22 Jan 2001
Intercostal, corroded
PHX - DURING K-CHECK, MID CARGO BAY UPPER FLANGE OF INTERCOSTAL AT FS 522-541, LONGERON 29 RT, WAS FOUND TO BE CORRODED. FABRICATED AND INSTALLED NEW…
- 22 Jan 2001
Longeron, corroded
PHX - DURING K-CHECK, FOUND LONGERON 30, AT FS 1287 IN THE AFT CARGO BAY, WAS FOUND TO BE CORRODED. FABRICATED AND REPLACED SECTION OF LONGERON WITH SPLICE…
- 21 Aug 2000
Bottle, discharged
SEA - PRIOR TO FLIGHT 752, THE L2 DOOR EMERGENCY EVACUATION SLIDE PRESSURE WAS FOUND TO BE LOW. REPLACED THE L2 DOOR SLIDE AND ROUTED TO SEA FOR INSPECTION…
- 22 May 2000
Light, inoperative
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 14 Mar 2000
Battery, discharged
LAX - FLT 466 - PRIOR TO DEPARTURE, CREW REPORTED THE EMERGENCY EXIT FLOOR TRACK LIGHTING AND EMERGENCY EXIT LIGHTS ILLUMINATED INTERMITTENTLY. REPLACED…
- 10 Feb 2000
Battery, discharged
PDX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 24 TO 27 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 30 Apr 1999
Wire, defective
SEA - DURING MAINTENANCE CHECK, BOTH RED EMERGENCY FLOOR TRACK LIGHTS AT L2 DOOR WERE FOUND INOPERATIVE. REPLACED WIRING IN FLOOR TRACK AND OPERATED NORMALLY.…
- 9 Feb 1999
Bearing, broken
ANC - DURING GROUND SERVICING, THE L2 DOOR WOULD NOT OPEN. FOUND DOOR LOWER SNUBBER BEARING AT FUSELAGE ATTACHMENT BROKEN. REPLACED BEARING AND OPERATED…
- 17 Aug 1998
Light, inoperative
PDX - RETURN TO GATE OF FLIGHT 516, CREW REPORTED THE EMERGENCY FLOOR TRACK RED LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. REPLACED WIRE SECTION IN FLOOR…
- 15 Aug 1998
Light, inoperative
PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK RED LIGHTS FOR THE AFT OVERWING EMERGENCY EXIT WERE FOUND INOPERATIVE. RESEATED CONNECTORS TO LIGHT…
- 4 Oct 1997
Light, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 26 Aug 1997
Latch Mechanism, out of adjust
SEA - AFTER ARRIVAL OF FLT 637 - CREW REPORTED, THE L1 DOOR WAS DIFFICULT TO UNLATCH. ADJUSTED THE L1 DOOR LATCH MECHANISM AND OPERATED NORMALLY. (M)
- 6 Jul 1997
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 24 TO 27 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 21 Jun 1997
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 21 TO 24 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 19 Jun 1997
Lamp, defective
SEA - AFTER ARRIVAL OF FLT 477, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 26 TO 29 WERE DIM. REPLACED LAMP MODUEL AND OPERATED NORMALLY. (M)
- 18 May 1997
Wire, broken
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 21 TO 23 WERE FOUND INOPERATIVE. REPLACED WIRE AT ROW 23 AND OPERATED NORMALLY. (X)