N953AS
1978 Cessna T337H standard FAA →
registration
- 1978
aircraft radio
earlier registrations
1 past record
- 1986
service difficulty reports
96 reports
- 26 Aug 2003
Lanyard, disconnected
SJC PREFLIGHT CHECK, FOUND FORWARD PAX L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 21 Aug 2003
Lanyard, damaged
SEA PREFLIGHT CHECK, FOUND FORWARD SERVICE R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND BROKEN. REPLACED LANYARD. (M)
- 13 Aug 2003
Lanyard, disconnected
PDX PREFLIGHT CHECK, FOUND FORWARD PAX L-1 DOOR EMERGENCY SLIDE LANYARD WAS DISCONNECTED. RECONNECTED LANYARD. (M)
- 7 Jul 2003
Lanyard, disconnected
PDX - PREFLIGHT CHECK, FORWARD PAX (L-1) DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
- 1 Jul 2003
Engine, failed
LAX - A LOUD BANG AND VIBRATION FROM RT ENGINE CLIMB AT FL24500 OUT OF LAX. SUSPECT COMPRESSOR STALL. DECLARED EMERGENCY AND RETURNED TO LAX. ENGINE WAS…
- 7 Mar 2003
Hinge, gouged
OKC - DURING 30K CHECK, FOUND AFT GALLEY SERVICE DOOR HINGE FITTING GOUGED. BLENDED GOUGE PER ASA EA 5240-01102. (M)
- 4 Feb 2003
Lanyard, disconnected
SEA - DURING PREFLIGHT CHECK, FOUND LEFT FORWARD (L-1) PASSENGER DOOR GIRT-TO-SLIDE COVER LANYARD DISCONNECTED. RETATTACHED LANYARD. (M)
- 5 Jan 2003
Light, dislodged
DURING PREFLIGHT CHECK DISCOVERED (1ST WHITE) EMERGENCY LIGHT POPPED OUT OF STRIP. REPAIRED GROUND. LIGHT THEN OPERATIVE PROPERLY.
- 14 Nov 2002
Coalescer Bag, dirty
LAX - FOUND CABIN BEGAN TO FILL WITH FUMES/SMOKE WITH APU OPERATING ON DESCENT INTO LAX. SHUTDOWN APU, AND FUMES/SMOKE DISSIPATED. PERFORMED TASK CARD…
- 7 Nov 2002
Light, missing
DURING PREFLIGHT CHECK DISCOVERED TRACK LIGHTING-3EA LITE FROM FRONT TOP COVER MISSING. (BASED ON THE CORRECTIVE ACTION, THIS WRITE-UP WAS TAKEN TO MEAN 3 EA…
- 7 Nov 2002
Lens, broken
DURING PREFLIGHT, CHECK FOUND EMERGENCY TRACK LIGHT WHITE LENS BROKEN. REPLACED LENS, A SUB-ASSEMBLY OF THE LIGHT MODULE. LIGHTS WHEN OPERATED PROPERLY.
- 11 Oct 2002
Longeron, corroded
OAK - FOUND DURING C-CHECK, CORROSION ON LONGERON 30 IN MID CARGO BAY AT FS 636-693. SPLICED IN NEW SECTION OF LONGERON 30 FROM STA 588-655 PER EA 5310-02110.…
- 11 Oct 2002
Door Frame, cracked
OAK - DURING C-CHECK, FOUND LEFT MLG WHEEL WELL DOOR JAMB CRACKED AT FORWARD OUTBOARD SIDE. REPLACED DOOR JAMB PER SRM 51-30-2, PAGE 4-12. (M)
- 3 Oct 2002
Longeron, corroded
OAK - FOUND DURING C-CHECK, CORROSION ON LONGERON 30 AT FS 1022 IN AFT CARGO BAY. SPLICED IN NEW SECTION OF LONGERON 30 FROM FS 1003 TO 1070 PER EA 5310-0211.…
- 2 Oct 2002
Beam, corroded
OAK - FOUND DURING C-CHECK, VERTICAL FACE OF AFT CARGO BAY LOWER BEAM TO BE CORRODED. INSTALLED BEAM DOUBLER AND SPLICE PER SRM 53-05. (M)
- 2 Oct 2002
Cargo Track, corroded
OAK - FOUND DURING C-CHECK, LEFT FORWARD TIEDOWN TRACK IN AFT CARGO BAY CORRODED ON OUTBOARD SIDE. REPLACED SECTION OF TRACK FROM STATION 1007-1193 PER SRM…
- 2 Oct 2002
Bracket, cracked
OAK - FOUND DURING C-CHECK, AFT CARGO BAY BARRIER DOOR OUTER SKIN FORWARD ATTACH BRACKET CRACKED. REPLACED BRACKET PER SRM 51-30-1. (M)
- 1 Oct 2002
Structure, cracked
OAK - FOUND DURING C-CHECK, CRACK IN AFT SIDE OF RIGHT MAINTENANCE PLATFORM IN AFT ACCESSORY COMPARTMENT. INSTALLED DOUBLER ON PLATFORM PER SRM 53-01, PAG 10,…
- 27 Sep 2002
Shear Tie, damaged
OAK - C-CHECK, FOUND AFT CARGO BAY SHEAR TIE WAS FOUND DAMAGED ON FORWARD LOWER LEG STATION 1136 BETWEEN LONGERON 29R AND 30. REPLACED SHEAR TIE WITH NEWLY…
- 27 Sep 2002
Intercostal, corroded
OAK - C-CHECK, FOUND CORROSION IN AFT CARGO BAY AT NR 5 WEB LIGHTING HOLE FROM STATION 1193 TO 1212, LONGERON 28R TO 29R. REPLACED INTERCOSTAL AT STATION 1193…
- 25 Sep 2002
Pan, corroded
OAK - C-CHECK, FOUND FORWARD CARGO COMPARTMENT DOOR CUTOUT PAN VERTICAL AND HORIZONTAL LEGS ARE CORRODED FROM STATION 370 TO 427 IN LINE WITH LONGERON 28R.…
- 24 Sep 2002
Beam, corroded
OAK - C-CHECK, FOUND AFT CARGO COMPARTMENT LOWER DOOR BEAM VERTICAL FACE IS CORRODED. INSTALLED BEAM DOUBLER AND SPACER EPR SRM 53-05, PAGE 173-179F. (M)
- 23 Sep 2002
Longeron, corroded
OAK - C-CHECK, FOUND MID ACCESSORY COMPARTMENT LONGERON SECTION CORRODED. REPLACED LONGERON SECTION FROM STATION 550 TO 585. INSTALLED NEW SPLICE AT EACH END…
- 23 Sep 2002
Frame, corroded
OAK - C-CHECK, FOUND AFT CARGO COMPARTMENT FRAME AND SPLICE CORRODED AT STATION 1309 FROM LONGERON 29L TO 29R. INSTALLED NEW SECTION PER SRM 53-03, PAGE 4A. (M)
- 23 Sep 2002
Skin, dented
OAK - C-CHECK, FOUND RIGHT WING INBOARD FLAP LOWER SURFACE HAS TWO DENTS. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 57-01, PAGE 15 AND 51-30-2, PAGE…
- 20 Sep 2002
Bracket, cracked
OAK - FOUND C-CHECK, MID CARGO BAY BARRIER DOOR AFT GUIDE RAIL BRACKET WAS CRACKED. REPLACED BRACKET PER SRM 51-30-2. (M)
- 20 Sep 2002
Structure, cracked
OAK - FOUND DURING C-CHECK, AFT ACCESSORY COMPARTMENT RIGHT MAINTENANCE PLATFORM WAS CRACKED ON AFT SIDE. INSTALLED PLATFORM DOUBLER PER SRM 53-01, FIG 2,…
- 20 Sep 2002
Support Bracket, cracked
OAK - FOUND C-CHECK, AFT ACCESSORY COMPARTMENT VENTRAL STAIRS RIGHT AFT SIDEWALL PANEL SUPPORT BRACKET CRACKED. INSTALLED SIDEWALL DOUBLER PER SRM 51-10-4 AND…
- 20 Sep 2002
Rub Strip, cracked
OAK - FOUND DURING C-CHECK, LEFT WING TO BODY FAIRING AFT FILLET 2108 CHAFE STRIP WAS CRACKED AT TOP SIDE. TRIMMED CRACK AREA AND BLENDED AREA FILLET PANEL…
- 20 Sep 2002
Splice, cracked
OAK - FOUND DURING C-CHECK, AFT CARGO COMPARTMENT LEFT INBOARD SEAT TRACK SPLICE WEB WAS CRACKED. TRIMMED AND SMOOTHED DAMAGE PER SRM 53-01.(M)
- 19 Sep 2002
Door Frame, cracked
OAK - DURING C-CHECK, FOUND LEFT MLG DOOR JAMB WAS CRACKED AT UPLOCK SENSOR CUT OUT DOUBLER. REPLACED DOOR JAMB CUTOUT DOUBLER PER SRM 51-10-2,-3, AND -4. (M)
- 19 Sep 2002
Door Frame, cracked
OAK - DURING C-CHECK, FOUND RIGHT MLG DOOR FORWARD JAMB CRACKED AROUND RIVET HEAD. REPLACED DOOR JAMB PER SRM 51-10-3, -4, 51-30-2 AND -5. (M)
- 4 Aug 2002
Connector, disconnected
SEA - DURING PREFLIGHT CHECK, EMERGENCY TRACK LIGHT AT 23D 'OUT OF SOCKET' DISCONNECTED. REPAIRED RECONNECTED SOCKET. LIGHTS THEN OPERATED PROPERLY. (M)
- 5 Mar 2002
Lanyard, disconnected
SEA - LEFT AFT GALLEY DOOR EMERGENCY SLIDE LANYARD DISCONNECTED. REATTACHED LANYARD. (M)
- 12 Nov 2001
Lanyard, detached
PHX - DURING LINE CHECK, L-1 DOOR EMERGENCY SLIDE GIRT BAR-TO-LATCH LANYARD WAS FOUND DETACHED. REATTACHED LANYARD. (M)
- 16 Sep 2001
Lanyard, disconnected
SEA - DURING PRE-FLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DETACHED FROM GIRT BAR. REATTACHED LANYARD TO GIRT BAR. (M)
- 20 Jun 2001
Battery Pack, inoperative
ANC - DURING PREFLIGHT, OVERWING EMERGENCY LIGHTS WERE DETERMINED TO BE INOPERATIVE. REPLACED BATTERY PACK. LIGHTS THEN OPERATED NORMALLY. (M)
- 16 May 2001
Harness, failed
OAK - DURING C-CHECK, FOUND L1 DOOR EMERGENCY SLIDE HARNESS FAILED VOLTAGE CHECK. REPLACED L1 DOOR EMERGENCY SLIDE WITH SERVICEABLE SLIDE. (M)
- 19 Apr 2001
Light, inoperative
PDX - DURING LINE CHECK, FORWARD CABIN PORTABLE EMERGENCY LIGHT WAS DETERMINED TO BE INOPERATIVE. REPLACED LIGHT ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)
- 27 Dec 2000
Window, out of adj
LAX - DURING PREFLIGHT CHECK, CAPTAINS SLIDING CLEARVIEW WINDOW WAS FOUND TO BE DIFFICULT TO OPEN. ADJUSTED AND LUBED WINDOW SLIDE MECHANISM. WINDOW THEN…
- 24 Sep 2000
Track, lack of lube
LAX - FLT 482 - PRIOR TO FLIGHT, THE CAPTAIN'S SLIDING WINDOW WAS DIFFICULT TO OPEN AND CLOSE. CLEANED AND LUBRICATED THE WINDOW TRACK AND THE WINDOW OPERATED…
- 31 May 2000
Latch, out of adj
SAN - PRIOR TO DEPARTURE OF FLIGHT 557, CREW REPORTED THE L1 DOOR WOULD NOT LATCH IN THE OPEN POSITION. ADJUSTED THE L1 DOOR HOLD OPEN MECHANISM AND OPERATED…
- 29 Feb 2000
Skin, cracked
PHX - DURING 15K CHECK, FOUND TWO CRACKS WERE FOUND ON THE L2 SERVICE DOOR EXTERIOR SKIN AROUND THE DOOR HANDLE CUTOUT AT THE EXIT PLACARD. REPAIRED PER SRM…
- 29 Feb 2000
Longeron, deformed
PHX - DURING 15K CHECK, THE FORWARD CARGO COMPARTMENT WAS FOUND DEFORMED AT LONGERON 29R, BETWEEN FS 237 AND 256. REPAIRED PER SRM 53-02, FIG 18. (M)
- 29 Feb 2000
Shear Tie, corroded
PHX - DURING 15K CHECK, THE MID CARGO COMPARTMENT MAIN FRAME SHEAR TIE CLIP WAS FOUND CORRODED AT FS 636, LONGERON 29R-30. REPAIRED PER SRM 51-30-5. (M)
- 29 Feb 2000
Pan, corroded
PHX - DURING 15K CHECK, THE AFT CARGO COMPARTMENT DOOR CUTOUT LOWER PAN WAS FOUND CORRODED AT FS 1155 RIGHT. REPAIRED PER SRM 51-30. (M)
- 29 Feb 2000
Cargo Track, corroded
PHX - DURING 15K CHECK, THE AFT CARGO COMPARTMENT RIGHT TIEDOWN TRACK WAS FOUND CORRODED AROUND SEVERAL CLIP NUT FASTENER HOLES, FS 1212 TO 1322. REPAIRED PER…
- 29 Feb 2000
Seat Track, corroded
PHX - DURING 15K CHECK, THE AFT CABIN LEFT INBOARD SEAT TRACK, BOTTOM SIDE OF THE FLANGE WAS FOUND CORRODED AROUND THE NUT PLATE HOLES (TWO EACH) AT, LBL 20.…
- 29 Feb 2000
Seat Track, corroded
PHX - DURING 15K CHECK, THE LEFT OUTBOARD SEAT TRACK WAS FOUND CORRODED AT FS 1155. REPAIRED PER SRM 53-05. (M)
- 29 Feb 2000
Skin, cracked
PHX - DURING 15K CHECK, THE FUSELAGE SKIN AT FS 1401 WAS FOUND CRACKED OUT OF FASTENER HOLE LENGTH .20 ABOVE NR 1 PYLON, THIRD FASTENER ABOVE SKIN SPLICE.…
- 11 Feb 2000
Angle, corroded
PHX - DURING 15K CHECK, THE FLOORBOARD ATTACH ANGLE AT FS 160-168, LBL 51 WAS FOUND CORRODED. REPLACED SUPPORT ANGLE PER SRM 51-30 ADN 53-01. (M)
- 11 Feb 2000
Attach Angle, corroded
PHX - DURING 15K CHECK, THE FLOORBOARD ATTACH ANGLE AT FS 160-200, LBL 45 WAS FOUND CORRODED. REPLACED SUPPORT ANGLE PER SRM 53-14-1. (M)
- 11 Feb 2000
Longeron, corroded
PHX - DURING 15K CHECK, THE ACCESSORY COMPARTMENT, FS 200-218, LONGERON 29L WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1. (M)
- 11 Feb 2000
Stringer, corroded
PHX - DURING 15K CHECK, THE FORWARD CARGO COMPARTMENT, FS 408, STRINGER 30 WAS FOUND CORRODED. REPAIRED PER SRM 53-01. (M)
- 11 Feb 2000
Attach Angle, corroded
PHX - DURING 15K CHEC, THE FORWARD CARGO COMPARTMENT FLOOR SUPPORT ATTACH ANGLE WAS FOUND WITH LIGHT SURFACE CORROSION AT FS 426 ABOVE LONGERON 28R. REMOVED…
- 11 Feb 2000
Strap, tool damage
PHX - DURING 15K CHECK, THE FORWARD CARGO COMPARTMENT AFT SIDE OF CARGO DOOR CUTOUT DOOR JAMB TIE STRAP HAS DRILL START, FS 427 ABOVE LONGERON 28R. REPLACED…
- 11 Feb 2000
Longeron, corroded
PHX - DURING 15K CEHCK, THE FORWARD CARGO COMPARTMENT LONGERON 30 WAS FOUND CORRODED AT FS 446-465, STRINGER 30. REMOVED CORROSION PER SRM 53-01. (M)
- 11 Feb 2000
Frame, corroded
PHX - DURING 15K CHECK, THE MID CARGO DOOR, LOWER BEAM WAS FOUND CORRODED ON THE FORWARD FLANGE OF THE FRAME AT FS 655, INBOARD OF THE LOWER BEAM, FORWARD…
- 11 Feb 2000
Structure, corroded
PHX - DURING 15K CHECK, THE LOWER WING-TO-BODY FAIRING SUPPORT STRUCTURE WAS FOUND CORRODED AT FS 902, RBL 18. REMOVED CORROSION PER SRM 53-01. (M)
- 11 Feb 2000
Channel, corroded
PHX - DURING 15K CHECK, A SPLICE IN THE FLOOR SUPPORT CHANNEL AT FS 1250 ABOVE STRINGER 30 WAS FOUND CORRODED ON THE BOTTOM SIDE. REMOVED CORROSION PER SRM…
- 11 Feb 2000
Web, cracked
PHX - DURING 15K CHECK, THE MAIN CABIN RIGHT WEB PANEL WAS FOUND CRACKED APPROXIMATELY SIX INCHES BETWEEN FS 1287 - 1309, RBL 50. REPAIRED PER SRM 53-01, FIG…
- 11 Feb 2000
Clip, corroded
PHX - DURING 15K CHECK, THE AFT CARGO TIE CLIP AT FS 1322, AFT SIDE BETWEEN STRINGER 29R AND 28R WAS FOUND CORRODED ON THE LOWER EDGE. REMOVED CORROSION PER…
- 11 Feb 2000
Longeron, corroded
PHX - DURING 15K CHECK, FS 216, LONGERON 29R WAS FOUND CORRODED IN AND AROUND THE RIVET TAIL. REMOVED CORROSION PER SRM 53-01. (M)
- 11 Feb 2000
Longeron, corroded
PHX - DURING 15K CHECK, THE FORWARD CARGO COMPARTMENT RIGHT SURFACE WAS FOUND CORRODED ON TOP FLANGE OF LONGERON 22 BETWEEN FS 446 AND 465. REMOVED CORROSION…
- 11 Feb 2000
Skin, corroded
PHX - DURING 15K CHECK, THE FUSELAGE OUTER LOWER SKIN AT FS 807, BL 0 WAS FOUND CORRODED IN SEVERAL AREAS. REMOVED CORROSION PER SRM 53-01. (M)
- 11 Feb 2000
Structure, corroded
PHX - DURING 15K CHECK, THE WING-TO-BODY FAIRING LOWER SUPPORT STRUCTURE WAS FOUND CORRODED AT FS 1000-1013, BL 0 TO RBL 10. REMOVED CORROSION PER SRM 53-01.…
- 11 Feb 2000
Panel, corroded
PHX - DURING 15K CHECK, THE RIGHT INBOARD WING UPPER SURFACE STATION XRS 60.000 FUEL BOOST PUMP ACCESS COVER PANEL WAS FOUND CORRODED. REMOVED CORROSION PER…
- 2 Jan 2000
Battery, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 29 TO 31 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 29 Nov 1999
Power Supply, failed
SEA - PRIOR TO DEPARTURE OF FLT 650, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND…
- 5 Jul 1999
Light, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 24 May 1999
Wire, defective
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 7 TO 9 WERE FOUND INOPERATIVE. REPLACED WIRING IN FLOOR TRACK AND OPERATED…
- 22 Feb 1999
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 10 Feb 1999
Wire, broken
PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 1 TO 9 WERE FOUND INOPERATIVE. REPAIRED WIRING IN FLOOR TRACK AND OPERATED…
- 27 Jan 1999
Mechanism, lack of lube
SEA - FLT 593 - CREW REPORTED L-1 DOOR WAS VERY DIFFICULT TO LOCK INTO POSITION. LUBED LOCKS AND OPERATED NORMALLY. (M)
- 26 Apr 1998
Track, dirty
FAI - AFTER ARRIVAL OF FLT 119, CRE REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW WOULD NOT OPEN. CLEANED DEBRIS FROM WINDOW ROLLER TRACK AND LUBED…
- 15 Apr 1998
Batteries, discharged
PDX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 14 TO 18 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER AND OPERATED…
- 2 Jan 1998
Power Supply, inoperative
SEA - DURING MAINTENANCE CHECK, THE FORWARD OVERWING EMERGENCY EXIT IDENTIFIERS REMAIN ON WITH THE MAIN BATTERY SWITCH OFF. REPLACED THE POWER SUPPLY AND…
- 26 Dec 1997
Mechanism, lack of lube
BUR - PRIOR TO DEPARTURE OF FLT 137, CREW REPORTED THE R1 DOOR HANDLE WOULD NOT MOVE TO CLOSED POSITION. LUBRICATED THE DOOR HANDLE MECHANISM AND OPERATED…
- 27 Aug 1997
Inflation Bottle, low pressure
OAK - DURING C-CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE TAILCONE EMERGENCY EVACUATION SLIDE…
- 24 Aug 1997
Mechanism, out of adjust
OAK - DURING C-CHECK, THE L1 DOOR WAS FOUND DIFFICULT TO LOCK. ADJUSTED THE L1 DOOR MECHANISM AND OPERATED NORMALLY. (M)
- 14 Dec 1996
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE FORWARD OVERWING EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES AND OPERATED NORMALLY. (M)
- 22 Sep 1996
Light, inoperative
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 18 Sep 1996
Batteries, discharged
ONT - DURING MAINTENANCE CHECK, THE OVERWING EMERGENCY LIGHTS ILLUMINATED WHEN THE AIRCRAFT BATTERY SWITCH WAS TURNED OFF. RECHARGED THE BATTERIES AND…
- 30 Aug 1996
Battery, discharged
SEA - DURING MAINTENANCE CHECK, THE INTERIOR EMERGENCY EXIT LIGHT BATTERY PACK AT ROW 21 WAS FOUND DISCHARGED. REPLACED BATTERIES AND LIGHTS OPERATED…
- 1 Jul 1996
Slide Bottle, low pressure
PDX - DURING MAINTENANCE CHECK, THE R1 DOOR EMERGENCY EVACUATIONSLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE R1 DOOREMERGENCY EVACUATION SLIDE.…
- 15 May 1996
Light, defective
SFO - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT NEON CHARGE LAMP DID NOT ILLUMINATE WITH SWITCH IN THE ARMED POSITION. REPLACED THE LIGHT…
- 9 May 1996
Boost Pump, defective
SEA - DURING DESCENT OF FLT 557, THE LT ENGINE SHUT DOWN. THE LT FUEL TANK TRANSFERRED FUEL INTO THE CENTER TANK WITH THE CENTER TANK FUEL BOOST PUMPS OFF.…
- 9 May 1996
Check Valve, defective
SEA - DURING DESCENT OF FLT 557, THE LT ENGINE SHUT DOWN. THE LT FUEL TANK TRANSFERRED FUEL INTO THE CENTER TANK WITH THE CENTER TANK FUEL BOOST PUMPS OFF.…
- 16 Apr 1996
Frame, corroded
PAE - DURING 30K CHECK, CORROSION WAS FOUND ON FRAME AT Y1061, X+1, Z-49. REMOVED DAMAGED AREA AND INSTALLED NEW PIECES IAW DC-9 SRM. TAT: 28,268. TAC:…
- 16 Apr 1996
Frame, corroded
PAE - DURING 30K CHECK, CORROSION WAS FOUND ON FRAME AT Y1322, X+15 TO X-15, Z-43. REMOVED DAMAGED AREA AND INSTALLED NEW PIECES IAW DC-9 SRM. TAT: 28,268…
- 16 Apr 1996
Shear Tie, corroded
PAE - DURING 30K CHECK, CORROSION WAS FOUND ON SHEAR TIE AT Y1322, X-5, Z-43. REMOVED DAMAGED AREA AND INSTALLED NEW PIECES IAW DC-9 SRM. TAT: 28,268. TAC:…
- 10 Feb 1996
Wire, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD TWO RED EMERGENCY FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPAIRED WIRE TO TRACK LIGHTS AND OPERATED NORMALLY.…
- 4 Sep 1995
Eel Batteries, discharged
SEA - DURING MAINTENANCE CHECK, ONE TAILCONE EMERGENCY LIGHT AND TWO AFT CABIN OVERHEAD EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES AND…
- 26 Jan 1995
Eel Batt Pack, discharged
SEA - AT CHECK, 4 OVERHEAD EMERGENCY LIGHTS IN MID CABIN COME ON WHEN ACFT POWER IS TURNED OFF. MAINTENANCE REPLACED BATTERY PACK. (W)
- 25 Jan 1995
Eel Lamp, failed
SEA - CHECK, L-1 DOOR PORTABLE EMERGENCY LIGHT INOP. MAINTENANCE RELAMPED AND OPS CHECKED NORMAL. (W)
- 23 Nov 1994
Wires, defective
SEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY TRACK LIGHTS AT ROW 10-20 INOPERATIVE. REPAIRED WIRING AND LIGHTS OPERATED NORMALLY. (W)