N871GA
1991 McDonnell Douglas DC-9-83(MD-83) standard FAA →
reservations
aircraft radio
1 past record
earlier registrations
1 past record
- 1991
service difficulty reports
67 reports
- 1 Nov 2017
Web, cracked
LT LOUVER AIR BOX WEB CORNER CRACKED. STOP DRILLED CRACK AND PERFORMED HFEC INSPECTION TO VERIFY CONTAINMENT OF CRACK IAW SRM 51-01 PAGE 9 PARA (21).
- 16 Jan 2017
Proximity Sensor, out of adjust
EMERGENCY DECLARED. GEAR DOOR LIGHT ILLUMINATED. R&R SHIMS & MOUNTING HARDWARE AT LT GEAR DOOR OPEN PROXIMITY SENSOR AS WELL AS LT MAIN LANDING GEAR DOOR…
- 7 Jan 2017
Spar Cap, corroded
RT HORIZ UPPER REAR SPAR CAP, AFT BARREL NUT HOLE HAS CORROSION. REPAIRED RT BARREL NUT HOLE 29 IAW EA 16631 REV P2.
- 7 Jan 2017
Spar Cap, corroded
LT HORIZ STAB UPPER REAR SPAR CAP BOTH AFT BARREL NUT HOLES HAVE CORROSION. REPAIRED LT FWD & AFT BARREL NUT HOLES IAW EA 16630.
- 29 Mar 2016
Connector, defective
STALL INDICATOR FAILURE ON OAP. DURING CRUISE RAN QRH 85.4, STALL SYS 2 DID NOT TEST, PULLED FIRST OFFICERS STALL SYS NR 2 CB. FOUND HARD FAULT ON STALL COMP…
- 28 Mar 2016
Computer, faulty
STALL IND FAILURE ON OAP SEVERAL TIMES IN FLIGHT. STALL SYS 2 WOULDN’T TEST, WENT OUT IN APPROX 1 MINUTE EACH TIME. R & R STALL WARNING COMPUTERS 1 & 2.…
- 17 Mar 2016
Proximity Sensor, faulty
DURING THE T/O ROLL RECEIVED THE SLAT DISAGREE & THE SLAT AURAL WARNING AROUND 70 KTS. ABORTED T/O. TAXIED BACK TO THE GATE. CAPTAIN WILL PUT THE DISCREPANCY…
- 27 Nov 2015
Battery Pack, inoperative
EMERGENCY LIGHTS OVER AFT F/A SEATS OUT. REPLACED BULBS & BATTERY TASKS IN AFT RT LAV REF AMM 33-53-00-4.
- 29 Aug 2015
Battery, discharged
ROW 10 - 11 FED OVERHEAD EMER LIGHTS WON’T TURN OFF. R & R ROW 10 - 11 FED OVERHEAD EMER LIGHT BATTERIES IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.
- 8 Aug 2015
Unknown, malfunctioned
T CAS SYS NOT REPORTING TRAFFIC PROPERLY WITH VISUAL CONTACT OF TRAFFIC CLEARLY ON LEFT SIDE OF ACFT FLIGHT PATH, T CAS INDICATED TRAFFIC TO BE THE RIGHT SIDE…
- 17 Jun 2015
Power Supply, inoperative
L2, AFT ENTRY & TAIL CONE EMER EXIT SIGN LIGHT INOPERATIVE. R & R L2, AFT ENTRY & TAIL CONE EMER EXIT SIGN POWER SUPPLY IAW MM 33-53-00. OPERATIONS CHECKED…
- 5 Jun 2015
Light, inoperative
LEFT EXTERIOR EMER LIGHT INOPERATIVE. RELAMPED LT EXTERIOR EMER LIGHT IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- 29 May 2015
Unknown, odor
APU RUNNING AT GATE, STRONG SMELL OF FUEL IN CABIN. PERFORMED LEAK CHECK OF APU, NO LEAKS NOTED IAW MM 49-00-00. SEE LOG PAGE 533394 FOR COALESCER SOCK LT &…
- 28 May 2015
Battery, discharged
TAIL COMPARTMENT EMER EXIT LIGHTS INOPERATIVE. REPLACED POWER SUPPLY BATTERIES FOR TAIL COMPARTMENT LIGHTS. OPERATIONS CHECKED NORMAL IAW AMM 33-50-00.
- 22 Apr 2015
Slat, dented
NUMBER 2 SLAT DENT, DMI 15786. RE-INSPECT REQUIRED AT NEXT C-CHECK IS NOW BEING TRACKED BY CONTROL 51000014. THIS CLEARS MEL 05-05-10 DMI 15786.
- 18 Sep 2014
Oil System, leaking
ON CLIMB OUT STRONG SMELL OF FUMES THROUGHOUT CABIN & COCKPIT. RAN QRH 26.2 FUMES DISSIPATED ONLY BRIEFLY & RETURNED DURING DESCENT. PERFORMED QRH 26.5 FUMES…
- 16 Jun 2014
Battery, discharged
L1 ENTRANCE UPPER EMER FLASHLIGHT INOPERATIVE. R & R BATTERY FOR UPPER FWD EMER FLASHLIGHT IAW AMM 25-60-00. OPERATIONS CHECKED NORMAL.
- 27 Feb 2014
Battery, discharged
FWD FLIGHT ATTENDANT PORTABLE EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERIES & OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.
- 21 Feb 2014
Sign, defective
SELF-ILLUMINATED EXIT SIGNS AT AFT OVERWING EXIT FAILED COMPARATOR CHECK DURING C-CHECK
- 18 Feb 2014
Skin, chafed
VERTICAL STABILIZER SKIN, PN 5912166-185, CHAFED. REMOVED DAMAGED SECTION OF SKIN & INSTALLED REPAIR DOUBLER & FAIRING PLATE IAW SRM 55-01 FIG 4.
- 18 Feb 2014
Skin, chafed
VERTICAL STABILIZER SKIN, PN 5912166-11, BONDED DOUBLER, PN 5912166-89, CHAFED. FABRICATED NEW SKIN PANEL IAW EA NR 15570 & INSTALLED IAW SRM 51-30-2.
- 16 Feb 2014
Floor Panel, corroded
AFT CARGO FLOOR PANEL HAS CORROSION ON UPPER & LOWER SURFACES, OUT OF SRM LIMITS. LOCATED & DRILLED REPLACEMENT PANEL PN 5936603-1 IAW SRM 51-10-4.
- 16 Feb 2014
Skin, dented
AFT CARGO DOOR SKIN DENTED OUT OF SRM LIMITS. REMOVED DAMAGED SECTION OF DOOR SKIN & INSTALLED REPAIR DOUBLER & FILLER IAW SRM 52-05 FIG 66.
- 16 Feb 2014
Sign, defective
SELF-ILLUMINATING EXIT SIGNS AT FWD OVERWING EXIT FAILED COMPARATOR CHECK DURING C-CHECK.
- 19 Jan 2014
Controller, malfunctioned
CLIMBING THROUGH FL 220 PRESSURIZATION FAILED CABIN ALT CLIMBING RAPIDLY, NO FLOW HIGH. FOLLOWED QRH LED TO DEPLOYING PAX O2 MASKS. R & R NR 1 & NR 2 PRESS…
- 24 Oct 2013
Bulkhead, cracked
CRACK FOUND ON FWD AND AFT SIDES OF CANTED BULKHEAD WEB AT BS 1463 BETWEEN LONGERON 8 & 9R.
- 26 Mar 2013
Packing, damaged
WHILE AT THE GATE IT WAS NOTICED THERE WAS FUEL DRIPPING FROM THE APU AND A SMELL OF FUEL WAS NOTICED IN THE CABIN AREA. REMOVED AND REPLACED THE FUEL CONTROL…
- 29 Nov 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 27 May 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 28 Apr 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Apr 2012
Ballast, malfunctioned
FLIGHT CREW PERSONNEL REPORTED SMOKE FROM ROW 36 DEF FROM PASSENGER SERVICE UNIT. MAINTENANCE DEPARTMENT REMOVED AND REPLACED LIGHT BALLAST IAW MD80 AMM…
- 3 Apr 2012
Flashlight, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Feb 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 23 Feb 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 1 Feb 2012
Battery, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE…
- 6 Jan 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 17 May 2011
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 5 May 2011
Coalescer Bag, dirty
WHILE DEPLANING, CABIN FILLED WITH SMOKE, ALL PASSENGERS AND CREW TAKEN OFF PLANE. SHUT OFF ELECTRICAL ON PLANE. DURING WALK AROUND FOUND PUDDLE OF HYDRAULIC…
- 5 Apr 2011
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 29 Mar 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 16 Feb 2011
Cusp Web, corroded
FLOOR CUSP WEB CORRODED IN MAIN CABIN FS 215 LBL 15. INSTALLED REPAIR DOUBLER TO FLOOR WEB AS FS 215 LBL 15 IAW MD80 SRM 53-01 FIG 4.
- 16 Feb 2011
Cusp Web, corroded
FLOORBOARD CUSP WEB CORRODED AT FS 200 IN MAIN CABIN LBL 44. REPAIRED CUSP WEB IAW MD80 SRM 53-01 FIG 4.
- 24 Jan 2011
Power Supply, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 21 Jan 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 1 Jan 2011
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 1 Jan 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 31 Dec 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 31 Dec 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 28 Nov 2010
Ballast, failed
FLIGHT CREW PERSONNEL REPORTED ON THE GROUND AT STATION TOL, SMOKE AND FUMES COMING OUT OF OVERHEAD SEAT ROW 31 AND 30 A AND C. CONTRACT MAINTENANCE PERSONNEL…
- 1 Sep 2009
Window Frame, cracked
THE WINDOW PAN WAS FOUND CRACKED AT STA 886-905 RT LOWER AFT TAB. REF AA N/R 6200761.
- 1 Sep 2009
Cusp Web, cracked
LEFT CUSP CRACKED AT STA 837.
- 1 Sep 2009
Pan, cracked
LEFT SIDE STA 946-965 FWD TOP EAR CRACKED ON WINDOW PAN.
- 1 Sep 2009
Pan, cracked
WO 94582 AT STA 1155 RT WINDOW BELT CRACKED AT LOWER FWD CORNER. REPAIRED PER ESO 80559 DATE 28 AUG 2009.
- 1 Sep 2009
Longeron, cracked
FOUND LT LONGERON 2 AT STA 1418 CRACKED.
- 31 Aug 2009
Pan, cracked
CABIN RT SIDE STA 1136 TOP AFT WINDOW PAN EAR CRACKED.
- 26 Jul 2009
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 8 Jul 2009
Smoke Detector, false activation
FLIGHT CREW REPORTED SMOKE IN CABIN AND AFT LAV SMOKE DETECTORS WERE SET OFF. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED ALL RELATED SYSTEM AND FOUND NO…
- 6 Oct 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 3 Aug 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 13 Mar 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK MAINTENANCE INSPECTION. MAINTENANCE REPORTED THAT THE EMERGENCY EGRESS PATH LIGHTING FROM ROW 20 TO 24, BOTH FORWARD…
- 26 Feb 2007
Portable Light, malfunctioned
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION LAS VEGAS MAINTENANCE REPORTED THAT THE MAIN PASSENGER DOOR (L1) PORTABLE EMERGENCY LIGHT WOULD NOT…
- 25 Feb 2007
Connector, loose
DURING A ROUTINE OVERNIGHT MAINTENANCE SERVICE CHECK LAS VEGAS MAINTENANCE REPORTED THAT THE ELECTROLUMINESCENT EGRESS PATH LIGHTING WOULD NOT TEST BETWEEN…
- 23 Feb 2007
Battery, separated
DURING A ROUTINE OVERNIGHT MAINTENANCE SERVICE CHECK LAS VEGAS MAINTENANCE REPORTED THAT THE FORWARD OVERWING HATCH EXIT SIGNS WOULD NOT TEST. FURTHER REPORT…
- 18 Feb 2007
Skin, gouged
FLIGHT 5184 IFP/SJC - DURING THE PRE-FLIGHT WALKAROUND A PILOT NOTICED WHAT APPEARED TO BE A GOUGE IN THE FUSELAGE ABOVE L1 MAIN PASSENGER DOOR. INVESTIGATION…
- 2 Feb 2006
Bulb, inoperative
LAS - MAINTENANCE FOUND THE OVERHEAD EMERGENCY LIGHT INOPERATIVE AT ROW 6. REMOVED AND REPLACED BULB AND OPERATIONALLY CHECKED GOOD IAW MM 33-50-00. AIRCRAFT…
- 18 Jan 2006
Bulb, inoperative
LAS - MAINTENANCE FOUND THE EMERGENCY LIGHT INOPERATIVE AT ROW 8. REPLACED BULB FOR EMERGENCY LIGHT AT ROW 8 IAW MM 33-53-00. OPERATIONALLY CHECKED GOOD.…
- 18 Jan 2006
Battery Pack, inoperative
LAS - MAINTENANCE FOUND THE EMERGENCY LIGHTS IN THE TAIL CONE AREA INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN THE TAIL CONE IAW MM 33-53-00.…