N852AS
Bombardier INC CL-600-2B19 FAA →
aircraft radio
earlier registrations
1 past record
service difficulty reports
124 reports
- 24 May 2016
Bulkhead, cracked
REAR PRESSURE BULKHEAD FORWARD FACE IS CRACKED AT RBL 27.50 AND RBL 9.50 BETWEEN WL 73.50 AND WL 120.43. COMPLIED WITH ECTC REO 601R-53-61-1285 10 AND ECTC…
- 6 Dec 2015
Connector, disconnected
LIGHTED FLOOR-LEVEL EXIT SIGN AT ENTRANCE WAY INOPERATIVE. REPAIRED WIRE SPLICE CONNECTORS IAW ESPM 20-17-31. SYSTEM OPS CHECKED GOOD. NO FURTHER ACTION.
- 27 Jun 2015
Sign, damaged
LIGHTED EXIT SIGN ABOVE SERVICE DOOR DAMAGED. R & R SIGN IAW AMM 33-51-13. SYSTEM OPS CHECKED GOOD.
- 9 Sep 2014
Charger, inoperative
OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R OVERWING EMERGENCY LIGHT CHARGER IAW AMM 33-51-04-04. PERFORMED OPS CHECK OF CHARGER IAW AMM 33-51-04-05, REF IPC…
- 3 May 2014
Skin, corroded
ACCESS PANEL LANDING, CORRODED AT 640AB RT WING. COMPLIED WITH REO 601R-57-21-030 AND EO 600-57-81.
- 3 May 2014
Skin, corroded
LT WING ACCESS PANEL LANDING CORRODED AT 540BB. COMPLIED WITH REO 601R-57-21-030 AND EO 600-57-81 AND REF AMM 28-11-01-400-801.
- 3 May 2014
Skin, corroded
LT WING ACCESS PANEL LANDING CORRODED AT 510AB. COMPLIED WITH REO 601R-57-21-030 AND ECTC EO 600-57-81.
- 28 Apr 2014
Isolator, broken
AFT PRESSURE BULKHEAD HAS ONE ISOLATOR NUT PLATE BROKEN UNDER PANEL 282DRW. R & R ISOLATOR ON AFT PRESSURE BULKHEAD, IAW SRM 51-42-13.
- 28 Apr 2014
Floor Panel, damaged
FLOOR PANEL 251DLF HAS TWO INSERTS PULLED THRU. REPAIRED FLOOR PANEL IAW MM CGFP-02, REV 1.
- 28 Apr 2014
Skin, dented
DENT ON RT INBD FLAP LOWER SKIN, AFT OF FLAP ACCESS PANEL 684BB, MARKED. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702. REMOVED DAMAGED AREA AND…
- 28 Apr 2014
Floor Panel, cracked
RIGHT ELEVATOR BAY FLOOR AT BS 193 IS CRACKED. COMPLIED WITH REO PL 601R-53-11-245. COMPLIED WITH EC/TC REO 601R-53-11-245.
- 13 Mar 2014
Inverter, inoperative
LEFT EMERENCY EXIT SIDE WALL EXIT LIGHT INOPERATIVE. R & R INVERTER IAW AMM 33-51-07. OPS CHECKED GOOD.
- 16 Oct 2013
Bulkhead, cracked
AFT PRESSURE BULKHEAD CRACKED AT LBL 27.50, UPPER END OF CARGO DOOR TRACK, EXTENDS UNDER TRACK. REPAIRED IAW REO 601R-53-61-5057. MAJOR REPAIR.
- 2 Oct 2013
Sign, inoperative
LEFT OVERWING EMERGENCY EXIT FLOOR LEVEL EMERGENCY EXIT SIGN INOPERATIVE. R & R THE LT OVERWING EMERGENCY EXIT FLOOR LEVEL EMERGENCY EXIT SIGN IAW AMM 33-51-10.
- 4 Aug 2013
Door, unknown
PAX DOOR WILL NOT OPEN. OPS CHECKED PAX DOOR IAW AMM 52-11-00, OPS CHECKED OK AT THIS TIME.
- 24 Jun 2013
Sign, damaged
LIGHTED EXIT SIGN NEXT TO MAIN PASSENGER DOOR IS DAMAGED. SECURED MAIN EXIT LIGHTED EXIT SIGN ZAW AMM 33-50-00. OP'S CHECKED GOOD.
- 5 Mar 2013
Lamp, burned out
LEFT REAR FUSELAGE EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP IAW AMM 33-51-21. OPS CHECKED GOOD.
- 31 Jan 2013
Light, inoperative
LEFT EMERGENCY EXIT FLOOR LIGHT INOPERATIVE. R & R LT EMERGENCY EXIT FLOOR LIGHT IAW AMM 33-51-10. OPS TESTED GOOD.
- 13 Nov 2012
Uplock, failed
GEAR DISAGREE WARNING AFTER TAKEOFF, RT MAIN GEAR RED OTHER INDICATORS WHITE. ACFT RETURNED TO DEPARTURE AFTER TAKE OFF, DISAGREE CAUTION DID NOT EXTINGUISH…
- 8 May 2012
Unknown, unknown
EMERGENCY LIGHTS ON CONTINUOUSLY NO MATTER THE SWITCH POSITION. PERFORMED OPS CHECK OF EMERGENCY LIGHTS SYS IAW AMM 33-51-00, NO DEFECTS NOTED AT THIS TIME.
- 2 May 2012
Lens, missing
EMERGENCY EXIT LENS COVER IN FRONT OF AIRSTAIR DOOR IS MISSING. RESECURED EMERGENCY FLOOD LIGHT COVER LENS IAW AMM 33-51-19.
- 15 Mar 2012
Seat Track, corroded
LIGHT SURFACE CORROSION ON RT SEAT TRACK BETWEEN FS 424 AND 449.85 WITH GOUGE AT FS 439. CORROSION REMOVED IAW SRM 53-21-49 DIMENSION "U" IS WITHIN LIMITS AT…
- 12 Mar 2012
Angle, cracked
FS 484 INTERCOSTAL OTBD ANGLE CRACKED AT LBL 27. REMOVE CRACKED ANGLE AND FABRICATED NEW CLIP IAW SRM 51-42-21 & 51-24-16. INSTALLED ANGLE IAW REO…
- 12 Mar 2012
Attach Fitting, cracked
FS INTERCOSTAL INBD CLIP CRACKED AT LBL27. REMOVED CRACKED ANGLE IAW SRM 51-42-21. FABRICATED NEW ANGLE IAW SRM 51-24-16. INSTALLED NEW ANGLE IAW REO…
- 12 Mar 2012
Attach Fitting, cracked
FS 484 INTERCOSTAL OTBD ANGLE CRACKED AT RBL 27. REMOVED CRACKED ANGLE IAW SRM 51-42-21. FABRICATED NEW INTERCOSTAL ANGLE IAW SRM 51-24-16. INSTALLED NEW OTBD…
- 7 Mar 2012
Sill, corroded
CARGO DOOR CUTOUT FLOOR SILL EDGE MEMBER HAS MULTIPLE SPOTS OF CORROSION. REMOVED CORROSION IAW SRM 51-42-06 AND SRM 51-21-06. PERFORMED UT THICKNESS…
- 7 Mar 2012
Pan, cracked
FWD AVIONICS BAY FLOOR PAN CRACKED AT BRAKE ACCUML GUAGE BRACKET. REPAIRED IAW GREO 601R-53-11-111.
- 7 Mar 2012
Floorbeam, corroded
FLOORBEAM AT FS 349.00 BETWEEN LBL 9.0 AND LBL 27.0 HAS SURFACE CORROSION. REMOVE SURFACE COROSION IAW SRM 51-21-06. REPAIR CLASSIFIED AS A MAJOR.
- 7 Mar 2012
Floorbeam, corroded
FLOORBEAM AT FS 349 BETWEEN LBL 27 AND FLOOR SILL HAS SURFACE CORROISON. REMOVE SURFACE CORROSION SRM 51-21-06.
- 7 Mar 2012
Sill, corroded
CORROSION FOUND AT SERVICE DOOR SILL BS 319. REMOVEED CORROSION IAW SRM 51-21-06. FOUND CORROSION OUT OF LIMITS IAW SRM 53-00-00, & SRM 51-21-06. REMOVED AND…
- 6 Mar 2012
Structure, cracked
CARGO AFT WALL CAP 281GZ CRACKED. DRILLED NEW PANEL TO FIT REF SRM 51-40-11.
- 6 Mar 2012
Seat Track, gouged
SEAT TRACK BETWEEN FS 559 AND 559+16 IS GOUGED. REMOVED SEAT TRACK IAW AMM 53-01-11-000-802. DRILLED SEAT TRACK AND INSTALLED IAW AMM 53-01-11-400-802.
- 6 Mar 2012
Frame, unknown
REQUIRE NDT TO COMFIRM SUSPECTED CRACK AT BAGGAGE BAY DOOR HANDLE FACE FRAME MECHANISM ASSY. REMOVED CARGO-COMPT HANDLE HOUSING IAW AMM 52-70-02-000-801, AMM…
- 19 Jan 2012
Flashlight, inoperative
CAPTAIN`S FLASHLIGHT SWITCH INOPERATIVE. R & R FLASHLIGHT IAW AMM 25-61-00.
- 11 Jan 2012
Control Unit, failed
RIGHT SPOILERON CAUTION MESSAGE IN FLIGHT. EMERGENCY DECLARED. R & R RT OTBD SPOILERON PCU IAW AMM 27-62-01. OPS CHECKED GOOD.
- 19 May 2011
Handle, lack of lube
PAX DOOR WOULD NOT OPEN. LUBRICATED PAX DOOR OUTER HANDLE IAW AMM 12-20-52. PERFORMED OPS TEST OF PAX DOOR IAW AMM 52-11-00 .
- 2 May 2011
Door, binding
RAMP REPORTS PAX DOOR DIFFICULT TO OPEN. OPS TEST OF THE PASSENGER DOOR IAW AMM 52-11-00. OPS CHECK, NO DEFECTS NOTED. (CLOSED)
- 25 Sep 2010
Bulb, burned out
REFR TO DMIL 560491-3 LIGHT BULB BURNED OUT IN EMERGENCY LIGHT FLOOD FIXTURE BY CABIN DOOR. R & R EMERGENCY FLOOD LIGHT BULB IAW AMM 33-51-01, DMIL CLEARED,…
- 24 Sep 2010
Bulb, burned out
LIGHT BULB BURNED OUT IN EMERGENCY LIGHT FLOOD FIXTURE BY CABIN DOOR ( CABIN EMERGENCY LIGHTS: FLOOR LEVEL EMERGENCY FLOODLIGHTS (ACFT WITH PHOTOLUMINESCENT…
- 3 Nov 2009
Wire Harness, damaged
ANTI SKID I/B CAUTION MESSAGE *REPEAT* EMERGENCY DECLARED, TRUCKS STANDING BY AS A PRECAUTION. OPEN- PENDING MX DETERMINATION OF AN APPROPRIATE C/A. (…
- 21 Sep 2009
Panel, cracked
PANEL 833AZ HAS MULTIPLE CRACKS APPROX 6" LONG AND COMPOSITE DAMAGE AT LOWER CORNER. REMOVED AND REPLACED THE PANEL 833AZ IAW AMM CH 25-26-01-000-801 AND…
- 3 Sep 2009
Post, cracked
FS 409.0+128 VERTICAL POST RBL 18.0 I/B AND O/B POSTS HAVE INDICATIONS NOTED APPROX .2" IN LENGTH 50% FSH AT AFT FLANGE WL 69.0. BOTH FAILED NDT INSPECTION.…
- 3 Sep 2009
Post, cracked
FS 409+128 VERTICAL POST LBL 18.0 O/B POST HAS INDICATION NOTED APPROX .2" IN LENGTH 50% FSH AT AFT FLANGE WL 69.0 FAILED NDT INSPECTION. REMOVED INBD AND…
- 30 Aug 2009
Placard, torn
PAX DOOR EXIT PLACARD ON STEPS TORN.
- 29 Aug 2009
Bulkhead, corroded
REAR PRESSURE BULKHEAD WEB THAT SURROUNDS THE LINTEL ATTACHMENT FITTING HAS A INDICATION NOTED APPROX .1" IN LENGTH 50% FSH FAILED NDT INSP. REPAIR PER EC/TC…
- 29 Aug 2009
Bulkhead, cracked
F.S. 559 BULKHEAD WEB HAS 3 INDICATIONS NOTED, LT F.S. 559 WEB O/B OF LBL 9.0 WL 52.10 INDICATION APPROX .2" IN LENGTH 50% FSH, RT F.S. 559 WEB I/B OF RBL…
- 28 Aug 2009
Support Angle, cracked
FS 484 RBL 27 SUPPORT ANGLE CRACKED. REMOVED AND REPLACED SUPPORT ANGLE IAW SRM 51-42-21.
- 28 Aug 2009
Seat Track, corroded
FLOOR SEAT TRACK CORRODED AT RBL 9 AFT OF FS 559. REMOVED FLOOR SEAT TRACK AT RBL 9, AFT OF FS 559 AND LOCATED HOLES ONTO NEW SEAT TRACK. DRILLED AND…
- 28 Aug 2009
Sill, corroded
CABIN FLOOR SILL STRUCTURE FS 409+128-559 RBL 36 HAS SEVERAL PLACES OF CORROSION. DISPOSITION OF THE BLENDED CORROSION DAMAGE IS IDENTIFIED ON THE RT SIDE…
- 28 Aug 2009
Sill, corroded
CABIN FLOOR SILL STRUCTURE FS409+128-559 LBL 36 SEVERAL PLACES OF CORROSION. C/W REO 601R-53-41-666 REV D.
- 20 Mar 2009
Light, inoperative
RT MID EXTERIOR EMERGENCY LIGHT INOP.
- 14 Dec 2008
Bulkhead, cracked
FWD PRESS BULKHEAD CRACKED AT PASS THROUGH FOR LANDING GEAR MANUAL RELEASE CABLE.
- 6 Sep 2008
Bpsu, out of rig
FLAPS FAIL MSG AT 20 DEGREES ON FINAL APPROACH. COMPLIED WITH QRH. EMERGENCY DECLARED. CK`D RIGGING OF BPSU`S. FOUND LT AND RT BPSU`S OUT OF RIG. RIGGED…
- 8 Feb 2008
Step, broken
PAX DOOR TOP STEP B/W BROKEN.
- 2 Jan 2008
Light, inoperative
AFT MOST CEILING EMERGENCY LIGHT INOP.
- 22 Aug 2007
Flashlight, inoperative
F/A FLASHLIGHT INOP.
- 12 Jul 2007
Support Bracket, cracked
LEFT T/R SWITCH SUPPORT FWD BRACKET (ANGLE) CRACKED AT TOP HOLE.
- 6 Jul 2007
Handle, cracked
ASD INNER VERTICLE RELEASE HANDLE CRACKED SEVERAL SPOT NEAR READ BALL. RIGGING ADJUSTMENT CHECKED GOOD. SUPPLEMENTAL - SDR CLOSED 07/16/07.
- 6 Jul 2007
Frame, corroded
STA 605 FRAME HAS CORROSION BETWEEN STR 27 AND 26 LEFT. COMPLIED WITH EC/TC REO 601R-53-61-2260.
- 6 Jul 2007
Floor Skin, corroded
LT SIDE PRESSURE FLOOR SKIN AND DOUBLERS ARE CORRODED AT SEVERAL LOCATION BETWEEN FS 409.00 + 128 AND FS 559.00 BETWEEN LBL 36 AND 45 AT WL 73.50. WORK…
- 6 Jul 2007
Fitting, cracked
INTERCOSTAL AT FS 484.00 BETWEEN LBL 27 AND 36 INBOARD CLIP IS CRACKED. FINISHED INSTALLING INBOARD CLIP AT FS 484 BETWEEN LBL 27 AND 36 IAW CRJ 200 SRM…
- 6 Jul 2007
Doubler, corroded
AFT POTABLE WATER DRAIN MAST SKIN DOUBLER UNDER FLOOR IS CORRODED.
- 6 Jul 2007
Floor Support, corroded
FLOOR SUPPORT BEAM TO AFT PRESSURE BULKHEAD ATTACH FITTING AT LBL 27 HAS CORROSION.
- 6 Jul 2007
Floor Support, corroded
FLOOR SUPPORT BEAM UPPER CAP BETWEEN FS 589.00 AND FS 621 AT LBL-27 IS CORRODED AT NUT PLATE HOLES.
- 6 Jul 2007
Frame, corroded
FRAME AT FS 333.00 HAS CORROSION AT STR 27.
- 6 Jul 2007
Frame, corroded
FRAME AT FS 349.00 HAS CORROSION ON FWD FRAME DOUBLER AND AFT SIDE OF FRAME AT STR 27. REMOVED UPPER RIVETS AT STA 349 TOP OF FRAME AT FRAME DOUBLER AND…
- 6 Jul 2007
Stringer, corroded
ASD FLOOR SUPPORT STRINGER CORRODED BETWEEN FS 310-349. WORK COMPLETED IN ACCORDANCE WITH: SRM`S 51-42-21, 51-40-11, & 51-42-06, AMM 52-70-04, & 52-70-04 NO…
- 6 Jul 2007
Floor Support, corroded
SERVICE DOOR FLOOR SUPPORT STRINGER CORRODED BETWEEN FS 310-349. REMOVED UPPER -239 ATTACH ANGLE. REMOVED CORRODED -253 ANGLE, STRINGER AND 2EA FWD & AFT…
- 6 Jul 2007
Floor Support, corroded
ASD FLOOR SUPPORT ANGLE ABOVE STRINGER CORRODED 310-349. BLENDED CORROSION ON ASD FLOOR SUPPORT ANGLE ABOVE STRINGER, WITHIN LIMITS. REMOVED CLIPS PRIMED…
- 6 Jul 2007
Beam, corroded
STA 349 CORRODED AT SERVICE DOOR TRANSVERSE BEAM RBL 45. BEAM RBL 45. WORK COMPLETED IN ACCORDANCE WITH: SRM 51-21-06, 53-00-00, 51-42-16, REO 601R-53-21-782,…
- 6 Jul 2007
Angle, corroded
SERVICE DOOR ANGLE CORRODED AT FS 31- 349 AT SERVICE DOOR SEAL. FOR CORROSION TO SERVICE DOOR SILL ANGLE, REFER TO WO 63655 N/R-00166. BLENDED CORROSION ON…
- 6 Jul 2007
Floor Support, corroded
FLOOR SUPPORT BEAM UPPER CAP BETWEEN FS 589.00 AND FS 621 AT RBL 27 IS CORRODED AT NUT PLATE HOLES. [07-20-07] COMPLIED WITH EC/TC REO 601R-53-00-214.
- 6 Jul 2007
Fitting, cracked
INTERCOSTAL AT FS 484.00 BETWEEN RBL 27 INBOARD CLIP IS CRACKED. FINISHED INSTALLING INBOARD CLIP AT FS 484 BETWEEN RBL 27 AND 36 IAW CRJ 200 SRM 51-42-21.…
- 6 Jul 2007
Floor Support, corroded
ALL CARGO FLOOR TRACKS AND TIE DOWNS ARE CORRODED BETWEEN FS 559.00 AND FS 621 AT LBL 9 AND LBL 27.
- 5 Jul 2007
Frame, corroded
FS 473.15 FRAME IS CORRODED ON RT SIDE INBOARD JUST ABOVE FLOOR LEVEL. BLENDED CORROSION AT FS 473.15 IAW CRJ 200 SRM 53-00-00, FOUND TO BE IN LIMIT.…
- 5 Jul 2007
Pressure Panel, corroded
AREAS OF CORROSION ON WING BOX PRESSURE FLOOR UPPER SURFACE SKIN AND DOUBLERS SPANNING BETWEEN FS 424.00 AND FS 559.00 + 16 BETWEEN RBL 45 AND 36. WORK…
- 5 Jul 2007
Placard, faded
ALL CREW ESCAPE HATCH EXTERNAL PLACARDS ARE FADED.
- 5 Jul 2007
Placard, worn
PUSH IN TO EXIT PLACARD WORN ON RT EMERGENCY EXIT DOOR (EXTERIOR).
- 5 Jul 2007
Structure, corroded
CORROSION AT FS 605 BELOW FLOOR IN CARGO BAY. REFER TO WO 63655 N/R-00150 AND 00160 FOR CORRECTIVE ACTION. SUPPLEMENTAL SDR - CLOSED 07/16/07.
- 4 Jul 2007
Angle, corroded
FWD CENTER FLOORBOARD ANGLE JUST FWD OF STA 280 CROSSBEAM HAS SURFACE CORROSION PER MTC.
- 4 Jul 2007
Angle, corroded
AFT ANGLE FS 280 BETWEEN RBL 9 AND LBL 9 CORRODED. APPLIED CORROSION INHIBITOR AND SEALANT TO BULKHEAD PER REO601R-53-11-956. SUPPLEMENTAL - SDR CLOSED…
- 3 Jul 2007
Fitting, cracked
RIGHT O/B FUSELAGE STA 280 CLIP IS CRACKED. REMOVED 1EA CRACKED ANGLE CLIP AT FUSELAGE STA 280 RBL 9. WORK DONE IAW CRJ 200 SRM 51-42-21. SUPPLEMENTAL - SDR…
- 3 Jul 2007
Skin, cracked
LEFT WING PLANK APPEARS CRACKED AT WS 148.019 LEFT, NEEDS NDT TO VERIFY CRACK. COMPLETED IN ACCORDANCE WITH REO 601R-57 21-130.
- 3 Jul 2007
Light, no test
LEFT EMERGENCY EXIT FAILED BETA LIGHT TEST.
- 26 May 2007
Bulkhead, cracked
AFT PRESSURE BULKHEAD WAS FOUND TO BE CRACKED AT LBL 9 AND APPROX WL 100.00 HAS BEEN CONFIRMED CRACK BY ET AND FPI TYPE 1, METHOD C. FOUND DURING COMPLYING…
- 14 Nov 2006
Steering Sys, inoperative
NWS STEERING INOP ON APPROACH TO ICT. FLT 4804 DEL 240 MINS. EMERGENCY EQUIP REQUESTED ON STANDBY AS A PRECAUTION.
- 5 Aug 2006
Angle, cracked
LT SIDE FS 640 ANGLE CRACKED AFT
- 4 Aug 2006
Angle, cracked
RT SIDE FS 640 ANGLE CRACKED AFT
- 26 May 2006
Light, inoperative
LT AFT EXT EMERGENCY LIGHT INOP.
- 6 Feb 2006
Handle, cracked
DURING A HANGAR INSPECTION, THE AVIONICS BAY DOOR HANDLE WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE AVIONICS BAY DOOR HANDLE.…
- 27 Nov 2005
Light, burned out
DURING A GROUND INSPECTION IN ATL, THE EMERGENCY FLOOR LIGHT, AT ROW 5, WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY FLOOR…
- 2 Nov 2005
Support Beam, cracked
DURING AN A-CHECK, THE RT SIDE ENGINE SUPPORT BEAM, AT BL36.20, WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE WILL REPAIR THE RT SIDE ENGINE SUPPORT…
- 31 Oct 2005
Step, broken
DURING A GROUND INSPECTION IN CVG, THE PASSENGER DOOR BOTTOM STEP WAS FOUND TO BE BROKEN. MAINTENANCE REMOVED AND REPLACED THE PASSENGER DOOR BOTTOM STEP.…
- 7 Oct 2005
Handle, inoperative
DURING CLIMB-OUT FROM ATL-BHM, THE CREW RECEIVED A NOSE GEAR DISAGREE MESSAGE ON THE EICAS. THE NOSE DOOR WAS OPEN AND THE NOSE GEAR REMAINED IN THE LOCKED…
- 10 Jul 2005
Intercostal, cracked
DURING A C-CHECK, THE PASSENGER DOOR INTERCOSTAL AND INNER SKIN WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE PASSENGER DOOR INTERCOSTAL…
- 7 Jul 2005
Angle, cracked
DURING A C-CHECK, THE LT OB FS 484 ANGLE WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRE THE LT OB FS 484 ANGLE IAW EO. (K)
- 5 Jul 2005
Plate, cracked
DURING C-CHECK, THE CARGO DOOR FLOOR LANDING PLATE WAS FOUND TO BE CRACKED FROM THE CENTER 2 RIVETS BEYOND LIMITS. MAINTENANCE REPAIRED THE CARGO DOOR FLOOR…
- 23 Jun 2005
Support Beam, cracked
DURING HANGAR MAINTENANCE, THE ENGINE SUPPORT BEAM WAS FOUND TO BE CRACKED IN THE TOP WEB AT THE FIRE LOOP BRACKET BEYOND LIMITS. MAINTENANCE REPAIRD THE…
- 28 Feb 2005
Skin, cracked
DURING HANGAR MAINTENANCE IN MCN, THE INTERNAL SKIN UNDER THE TOP STEP ON THE PASSENGER DOOR WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE…
- 28 Feb 2005
Step, cracked
DURING HANGAR MAINTENANCE IN MCN, THE BOTTOM STEP ON THE PASSENGER DOOR WAS FOUND CRACKED AT THE FORWARD SECTION. MAINTENANCE REMOVED AND REPLACED THE BOTTOM…
- 23 Nov 2004
Clamp, loose
AFTER TAKEOFF, WHEN CLIMBING THROUGH 12,000 FT, THE CREW RECEIVED A MASTER WARNING, 14TH STAGE DUCT ON EICAS AND DUCT FAIL OF 14TH STAGE PANEL. THE QRH WAS…
- 12 Nov 2004
Clamp, loose
DURING CLIMB-OUT, AT APPROXIMATELY 25,000 FT, THE CREW RECEIVED AT RIGHT 14TH DUCT WARNING MESSAGE. THE QRH WAS COMPLIED WITH AND THE RT ENGINE THRUST LEVER…
- 11 Nov 2004
Loop, malfunctioned
DURING CLIMB-OUT, AT APPROXIMATELY 9,500 FEET, THE CREW RECEIVED A TRIPLE CHIME RT 14TH DUCT MESSAGE AND AURAL WARNING. THE CREW LEVELED THE AIRCRAFT TO…
- 29 Oct 2004
Step, cracked
DURING A GROUND INSPECTION, THE BOTTOM STEP ON THE PASSENGER DOOR WAS FOUND TO BE CRACKED AT THE LIFT POINT. MAINTENANCE REMOVED AND REPLACED THE BOTTOM STEP…
- 21 Aug 2004
Strut, leaking
FLT 4619 - DURING A GROUND INSPECTION IN ATL, THE PASSENGER DOOR WAS FOUND HARD TO OPEN. MAINTENANCE REMOVED AND REPLACED THE AFT GAS STRUT AND ADJUSTED THE…
- 29 Jul 2004
Wire, disconnected
DURING GROUND INSPECTION IN DFW, THE FORWARD EMERGENCY FLOOR STRIP INOPERATIVE. MAINTENANCE FOUND THE FORWARD ORAGNE STRIP OF FLOOR EMERGENCY LIGHTING…
- 2 Feb 2004
Step, broken
FLT 4228 - DURNIG A GROUND INSPECTION IN DFW, THE BOTTOM STAIR CONTROL ROD ON THE PASSENGER DOOR WAS FOUND BROKEN. MAINTENANCE REMOVED AND REPLACED THE BOTTOM…
- 15 Jan 2004
Step, cracked
DURING A C-CHECK IN MCN, THE TOP STEP ON THE PASSENGER DOOR WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE TOP STEP ON THE PASSENGER DOOR.…
- 8 Jan 2004
Clip, cracked
DURING A C-CHECK IN MCN, A CLIP UNDER THE CARGO COMPARTMENT SILL PLATE AT FS 589 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED A…
- 7 Jan 2004
Frame, cracked
DURING A C-CHECK IN MCN, FRAME FS 718, STRINGERS 10-11 ON THE RT SIDE WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED FRAME FS 718, STRINGERS…
- 6 Jan 2004
Floor Support, cracked
DURING A C-CHECK, THE CARGO COMPARTMENT AFT FLOOR SUPPORT ANGLES ON THE LT AND RT SIDES AT FS 621 WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS…
- 6 Jan 2004
Plate, cracked
DURING A C-CHECK, THE CARGO SILL PLATE UNDER THE FORWARD ATTACH BRACKET AT FS 562.72-589 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REMOVING AND…
- 6 Jan 2004
Step, cracked
DURING A C-CHECK IN MCN, THE TOP STEP ON THE PASSENGER DOOR WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE TOP STEP ON THE PASSENGER DOOR.…
- 6 Jan 2004
Clip, cracked
DURING A C-CHECK IN MCN, THE FLOOR SUPPORT CLIPS AT FS 280, LBL 9 AND RBL 9 WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOOR…
- 6 Jan 2004
Intercostal, cracked
DURING A C-CHECK IN MCN, THE LT INTERCOSTAL AT FS 484, BL 27-36 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REMOVING AND REPLACING THE LT…
- 6 Jan 2004
Clip, cracked
DURING A C-CHECK IN MCN, THE RT INTERCOSTAL CLIP AT APPROXIMATELY FS 484 IB AND OB WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE RT…
- 8 Nov 2003
Pin, inoperative
DURNG AGROUND INSPECTION IN DTW, PASSENGER DOOR INNER HANDLE WOULD NOT STOP AND THE DOOR WOULD NOT OPEN FROM THE INSIDE. MAINTENANCE REMOVED AND REPLACED THE…
- 5 Nov 2003
Spring, broken
DURING A GROUND INSPECTION IN MGM, THE PASSENGER DOOR WAS DIFFICULT TO CLOSE AND UPON OPENING IT FELL RAPIDLY. MAINTENANCE REMOVED AND REPLACED THE PASSENGER…
- 4 Sep 2003
Angle, cracked
DURING HANGAR MAINTENANCE IN BTR, THE SUPPORT DOUBLER AT FS 640 BETWEEN STRINGERS 9 AND 12 WAS FOUND TO BE CRACKED IN THE RADIUS BEYOND LIMITS. MAINTENANCE…
- 17 May 2003
Light, inoperative
DURING A GROUND INSPECTION IN ATL, THE FORWARD SECTION OF EMERGENCY FLOOR LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY…
- 19 Mar 2003
O-Ring, cut
FLT 4673 - DUIRNG CLIMB-OUT FROM ATL-SHV, THE CREW EXPERIENCED LOW OIL PRESSURE ON THE RIGHT ENGINE WITH IT DROPPING TO 21 PSI. QRH PROCEDURES WERE COMPLIED…
- 11 Feb 2002
Engine, vibration
FLT 4563 - WHILE CLIMBING OUT OF FWA, AT 21,000 FEET, THE LEFT ENGINE N2 VIBRATION SPIKED APPROXIMATELY 2.6 MILS. THE FLIGHT ATTENDANT AND PASSENGERS REPORTED…
- 11 Feb 2002
Gear, broken
FLT 4563 - WHILE CLIMBING-OUT OF FWA, AT 21,000 FEET, THE LEFT ENGINE N2 VIBRATION SPIKED APPROXIMATELY 2.6 MILS. THE FLIGHT ATTENDANT AND PASSENGERS REPORTED…
- 1 Aug 2000
Actuator, inoperative
APPROX 4 MINUTES INTO FLIGHT WITH AUTOPILOT ENGAGED, AP PITCH TRIM MESSAGE CAME ON. CREW FOLLOWED PROCEDURES, BUT MESSAGE RESUMED. THIS OCCURRED SEVERAL TIMES…