N789DL
2005 Cirrus Design Corp SR22 standard FAA →
registration
- 2005
aircraft radio
earlier registrations
1 past record
service difficulty reports
17 reports
- 4 Jul 1997
Controller, intermittent
NR 2 ENGINE A LOOP FIRE DETECTION CAME ON DURING CLIMB-OUT. LIGHT WENT OUT WHEN POWER WAS REDUCED. FOUND CONTROLLER INTERMITTENT, REPLACED CONTROLLER AND SYS…
- 11 Jun 1997
Spar Web, cracked
THE FS 1043, 1103 AND 1163 SPAR WEBS WERE FOUND TO BE MISSING A ROW OF ATTACH FASTENERS AT THE LBL AND RBL 116 END RIB ATTACH ANGLE. ONLY ONE ROW WAS…
- 3 Apr 1997
Pack, failed
OVERHEAT LIGHT IN PACK NR 3 FOLLOWED BY AREA -C- OVERHEAT WITH PACKS 1 AND 2 RUNNING SMOKE STARTED ENTERING CABIN. TURNED NR 2 PACK OFF AND OPENED DOORS SMOKE…
- 1 Apr 1997
Pack, malfunctioned
WHEN NR 3 PACK TURNED ON STRONG SULFUR SMELL IN AFT CABIN. DEFERRED NR 3 PACK, AIR OUT A/C, CKED PACK COMPT AND PACK CONTRL VLV AND ALL CKED OK.
- 1 Apr 1997
Compressor, damaged
CRUISE AT FL330, EXPERIENCED A YAW TYPE JOLT WITH POPPING SOUNDS FROM CAPTS SIDE OF AIRPLANE. ENG NR 1 VIBS WENT FROM 1.0 TO 1.8 FLIGHT ATTENDANT THEN…
- 23 Jan 1997
Engine, tailpipe fire
NR 1 ENG TAILPIPE FIRE. INSPECTED NR 1 ENG, FOUND OK. RAN ENG, CHECKED OK.
- 16 Jan 1997
Engine, failed
ON DESCENT, WHEN IDLING BACK THE CABIN FILLED WITH AN ODOR OF KEROSENE. REPLACED NUMBER THREE ENGINE.
- 26 Nov 1996
Support Fitting, cracked
FURTHER CRACKING WAS FOUND IN BOTH THE LT AND RT NLG SHOCK STRUT SUPPORT FITTINGS.
- 3 Jul 1996
Power Supply, inoperative
G-CK, OPN78100 OVERHEAD EMERGENCY LIGHTS BATT PACK DOES NOT TEST PROPERLY WITH SW ON PACK, COMES ON BUT GOES DIM IMMEDIATELY. REPLACED PWR SUPPLY, TEST GOOD…
- 3 Jul 1996
Power Supply, inoperative
OVERHEAD EMERGENCY LIGHTS BATT PACK ADJACENT TO L4 DOOR DOES NOT TEST PROPERLY WITH SW ON BATT PACK, LIGHTS COMES ON BUT GOES DIM IMMEDIATELY. REPLACED PWR…
- 2 Jul 1996
Bulkhead, buckled
DURING LTR CHK, THE AFT PRESSURE BLKH AT FS 1809 WAS FOUND TO BE BUCKLED. THE DAMAGED SECTION WAS CUT OUT AND A NEW PART WAS SPLICED IN.
- 1 Jul 1996
Skin, cracked
DURING A LETTER CHECK INSPECTION, A SMALL CRACK WAS FOUND IN THE UPPER AFT CORNER OF THE R1 DOOR. THE CONDITION WILL BE REPAIRED PER L1011 SRM 53-15-00, FIG…
- 1 Jul 1996
Skin, cracked
AN EXISITNG REPAIR WAS REMOVED FOR INSPECTION AND FOUND TO HAVE FURTHER DAMAGE. THIS REPAIR HAS BEEN INCORPORATED INTO ER/A 359868-14. NO FURTHER WORK IS…
- 17 May 1996
Skin, dented
JETWAY HIT A/C CAUSING SKIN DAMAGE 1.5 BY 8 BETWEEN FS 489 AND 509 AND STR 15 AND 15. THE DAMAGE WAS CUT OUT AND A FILLER WAS INSTALLED AND REINFORCED. REV A…
- 16 May 1996
Bulb, failed
L-1 EXTERIOR SLIDE LIGHT HAS ONE BULB IS INOP. RELAMPED, OP CKS GOOD.
- 8 Feb 1996
Battery Charger, inoperative
L4 EMERGENCY SLIDE LIGHT INOP. REPLACED BATTERY/CHARGER, OPERATION NORMAL.
- 5 Aug 1995
Eel, malfunctioned
EMERGENCY LIGHTS FAIL L/O TEST STEPS 13, 14 AND 15, ONLY C-ZONE LIGHTS CAME ON. RESET EMERGENCY LIGHTS, CHARGE C/B'S, TEST OK.