    s/n 117 engine Rolls-Royc Spey Mk 511SR

service difficulty reports

33 reports
  1. 19 Oct 2006

    Tee Fitting, cracked

    Gulstm G1159

    UPON POST FLIGHT INSPECTION THE PILOT NOTICED SMALL AMOUNT OF HYDRAULIC FLUID SEEPING FROM THE BOTTOM OF THE RADOME. MAINTENANCE DETERMINED THAT THE LEAK WAS…

  2. 25 May 2000

    Light, loose

    Doug DC987

    FLL - FLT 679 - FOUND FLOOR EMERGENCY LIGHT WILL NOT LAY FLAT, KEEPS POPPING OUT AT ROW 27. SECURED TRACK LIGHT OPS CHECK OK IAW MM 33-50. (M)

  3. 1 May 2000

    Light, inoperative

    Doug DC987

    ISP - FLT 718 - EMERGENCY ISLE PATH LIGHTING BROKEN BY ROW 1. NOT ''BROKEN'' LIGHT SEGMENT IS OUT OF TRACK. RE-INSTALLED EMERGENCY LIGHT SEGMENT INTO TRACK.…

  4. 24 Apr 2000

    Light, missing

    Doug DC987

    DTW - EMERGENCY TRACK LIGHTING FLOOR LENS ROW 1 MISSING. INSTALLED LENS AT ROW 1 EMERGENCY TRACK LIGHTING, REF 33-50-00 MD 80 MM. (M)

  5. 15 Apr 2000

    Power Supply, inoperative

    Doug DC987

    DTW - EMERGENCY CEILING LIGHTS ROW 3 AND 4 IS OUT. REMOVED AND REPLACED BATTERY POWER SUPPLY AND OPS CHECK GOOD IAW MM 33-50-00. (M)

  6. 14 Apr 2000

    Light, missing

    Doug DC987

    FLL - FLT 739 - FLOOR TRACK LIGHT MISSING ROW 12. INSTALLED LIGHT BULB AND COVER PER MM 33-60-0. OPS CHECK GOOD. (M)

  7. 18 Mar 2000

    Light, loose

    Doug DC987

    DTW - FLT 378 - AISLE PATH LIGHTS AT ROW 5/6 POPPED OUT. AISLE PATH LIGHT BULB AND LENS CRUSHED BY PASSENGER ROW 13. RESECURED AISLE PATH LIGHTS AT SEATS 5…

  8. 7 Mar 2000

    Light, loose

    Doug DC987

    LGA - FLT 419 - ROW 13 EMERGENCY LIGHT POPS OUT. RE-INSTALLED LENS COVER. (X)

  9. 6 Mar 2000

    Light, missing

    Doug DC987

    DTW - FLT 378 - ISLE PATH LIGHTING HAS MISSING LIGHT AT ROW 1D. RESEATED LAMP ASSY IAW MM 33-50-00. UNIT OPS CHECKS GOOD; NO DEFECTS NOTED. (X)

  10. 25 Feb 2000

    Battery Pack, inoperative

    Doug DC987

    DTW - EMERGENCY PATH LIGHTS INOPERATIVE BY OVERWING EXIT ROWS. REPAIRED SHORTED WIRE AND REMOVED AND REPLACED BATTERY PACK MM 33-50-00 AND OPS CHECK. NO…

  11. 24 Feb 2000

    Light, loose

    Doug DC987

    DTW - TRANSFERRED FROM CABIN LOG, FLOOR TRACK COMING OUT AT ROWS 4/5. RESECURED TRACK LIGHTING. OPS CHECKED GOOD IAW MD 80 MM 33-51-00. (M)

  12. 16 Jan 2000

    Wire, exposed

    Doug DC987

    DTW - EMERGENCY TRACK LIGHT AS ROW 11 WIRE PULLED OUT. REPLACED LIGHT SOCKET ASSEMBLY IN EMERGENCY FLOOR TRACK LIGHTING AT ROW 11. FUNCTIONAL CHECK GOOD. REF…

  13. 1 Jan 2000

    Cover, missing

    Doug DC987

    DTW - FLT 378 - FROM CABIN LOG, SEAT 25D AISLE PATH LIGHT COVER MISSING. REINSTALLED PATH LIGHT COVER AT SEAT 25D IAW MM CHAPTER 33-00. OPS CHECK GOOD. (M)

  14. 26 Dec 1999

    Light, loose

    Doug DC987

    DTW - FLT 378 - EMERGENCY FLOOR LIGHTING LOOSE NEAR FORWARD GALLEY. REPLACED AND RESECURED FLOOR TRACK LIGHTING NEAR FORWARD GALLEY AS REQUIRED. FUNCTIONAL…

  15. 19 Dec 1999

    Light, inoperative

    Doug DC987

    DTW - EMERGENCY FLOOR TRACK LIGHTING BETWEEN ROWS 25 NEEDS TO BE REPLACED. REMOVED AND REPLACED FLOOR TRACK LIGHT SOCKET. SYSTEM OPS CHECKS GOOD IAW MM…

  16. 15 Nov 1999

    Warning Light, illuminated

    Doug DC987

    DTW - FLT 712 - LEFT REVERSER ACCUMULATOR LOW LIGHT CAME ON DURING CRUISE. COMPLIED WITH QRH AND LIGHT CAME BACK ON AFTER 45 MINUTES. PERFORM OPS CHECK ON…

  17. 7 Nov 1999

    Power Supply, inoperative

    Doug DC987

    DTW - BOTH FORWARD OVERWING EMERGENCY EXITS LIGHTS INOPERATIVE. REPLACED EMERGENCY POWR SUPPLY, OPS CHECK GOOD PER MM 33-51-00. (M)

  18. 18 Jul 1999

    Bulb, failed

    Doug DC987

    A COUPLE OF LIGHTS OUT ON EMERGENCY FLOOR LIGHTING, ALSO NOTICED A FEW LENSES MISSING. INSTALLED NEW LENSE COVER AND BULBS, OPERATIONAL CHECK GOOD IAW MM REF…

  19. 14 Apr 1999

    Light, inoperative

    Doug DC987

    LGA - TAIL COMPARTMENT OVERHEAD EMERGENCY LIGHT AT STATION 1408. BROKEN AND INOPERATIVE AT BULB HOLDER BASE. REPLACED BROKEN BULB HOLDER BASE OF LIGHT L2-637…

  20. 13 Apr 1999

    Light, inoperative

    Doug DC987

    LGA - L1 EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY WITH REPAIRED ASSEMBLY PER MM 33-50-00. OPERATION CHECK OK. (M)

  21. 4 Apr 1997

    Socket, failed

    Doug DC987

    EMERGENCY LIGHT OUT IN FLOOR TRACK ROW 5. PLACED ON MEL, DMI NR 78. DMI NR 78 CLEARED LATER THAT DAY BY REPLACING LIGHT BULB RECEPTACLE. OPS CHECKED GOOD. (M)

  22. 19 Oct 1996

    Cover, loose

    Doug DC987

    LINE MAINTENANCE AT IFP, FOUND THE FORWARD EMERGENCY TRACK LIGHT COVER LOOSE. MAINTENANCE RESECURED THE FORWARD EMERGENCY TRACK LIGHT COVER. OPERATIONAL CHECK…

  23. 19 Oct 1996

    Cover, missing

    Doug DC987

    LINE MAINTENANCE AT IFP, FOUND THE EMERGENCY TRACK LIGHT COVER MISSING AT ROW 8. MAINTENANCE REPLACED THE EMERGENCY TRACK LIGHT COVER. OPERATIONAL CHECKED…

  24. 3 Jul 1996

    Light, loose

    Doug DC987

    LINE MAINTENANCE AT IFP, DISCOVERED THAT EMERGENCY FLOOR PATH LIGHT STRIP CAME LOOSE IN PASSENGER CABIN. MAINTENANCE SECURED THE EMERGENCY FLOOR TRACK LIGHT…

  25. 2 Aug 1995

    Prox Box, inoperative

    Doug DC987

    WHEN LANDING GEAR WAS LOWERED NO LIGHT CAME ON, ON LEFT MAIN. WHEN NOSE AND RIGHT BECAME GREEN, LEFT BECAME RED. EMERGENCY EXTENSION PROCEDURE ACCOMPLISHED.…

  26. 15 May 1995

    Airframe, bird strike

    Doug DC987

    ON TAKEOFF, ACFT SUFFERED A BIRD STRIKE. C/W BIRD STRIKE INSPECTION PER MM 05-51-08 PG 601 REF CC1, NR 4 AND NR 5. NO OTHER DEFECTS NOTED. (X)

  27. 5 May 1995

    Eel Battery, discharged

    Doug DC987

    EMERGENCY OVERWING LIGHTS INOP. REMOVED AND REPLACED EMERGENCY OVERWING LIGHTING POWER SUPPLY. OPS CHECK GOOD. (Z)

  28. 16 Apr 1995

    Eel Wire, loose

    Doug DC987

    FLOOR AISLE LIGHTS INOP FROM EMERGENCY EXIT TO REAR. REPAIRED LOOSE WIRE. OPS CHECK NORMAL. (W)

  29. 14 Apr 1995

    Eel, inoperative

    Doug DC987

    ONE RED FLOOR TRACK LIGHT INOP IN FORWARD AND AFT CABIN, TWO WHITE LIGHTS INOP IN FIRST CLASS CABIN. REPLACED BULB AT FORWARD RED LENS, SOLDERED BROKEN WHITE…

  30. 19 Mar 1995

    Switch, failed

    Doug DC987

    RNO - ON CLIMB-OUT FROM LAS, AFTER GEAR RETRACTED, GEAR HORN SOUNDED AND ALL RED GEAR LIGHTS WERE RED. AT LEVEL OFF, ALL RED LIGHTS WENT OUT. REMOVED AND…

  31. 18 Mar 1995

    Gear Warning, activated

    Doug DC987

    RNO - ON TAKEOFF, GEAR WARNING HORN AND RED GEAR UNSAFE LIGHTS CAME ON. HORN COULD BE SILENCED, RED LIGHTS ON UNTIL 210 IAS. PERFORMED PROX BOX BITE TEST. OPS…

  32. 17 Mar 1995

    Eel Battery, discharged

    Doug DC987

    DURING T/S INSPECTION, FOUND EMERGENCY TRACK LIGHTING INOP. REPLACED FLOOR TRACK LIGHTING BATTERY POWER SUPPLY. OPS CHECK NORMAL. (W)

  33. 8 Jan 1995

    Eel, inoperative

    Doug DC987

    EMEREGENCY LIGHT FIXTURE AFT STAIRWELL MIDDLE INOP. RELAMPED. OPS CHECK NORMAL. (X)

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05624 Nov 2026
FCC GMRS633,27224 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,84423 Nov 2026
FAA registered aircraft319,59223 Nov 2026
FAA N-number reservations126,12623 Nov 2026
FAA dealers12,51023 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,33524 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.