N722AA
1972 Cessna 172M standard FAA →
registration
- 1972
aircraft radio
2 past records
NTSB
- 20 Apr 1998
accident, Chicago IL
- 17 Oct 1984
incident, Las Vegas NV
service difficulty reports
61 reports
- 29 Mar 2001
Module, inoperative
MIA - DURING OVERNIGHT MAINTENANCE FIRST CLASS EMERGENCY EXIT LIGHT DIM. REPLACED FIRST CLASS EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL…
- 8 Feb 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PROXIMITY LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT SEGMENTS AT ROW 6, 8 AND 26. SYSTEM GROUND…
- 23 Jan 2001
Skin, corroded
TUL - FOUND LOWER WING SKIN ABOVE RIGHT PRIMARY HEAT EXCHANGER IS INFECTED WITH MODERATE TO HEAVY CORROSION LBL 32-RBL 32 STRINGER 3-5, STATION 805-820.…
- 22 Jan 2001
Pan, corroded
TUL - FOUND LAVATORY PAN CORRODED AROUND LAV TANK WEB FORWARD MOUNTS AND SURROUNDING WEB LBL 36, BS 1146. BLENDED OUT CORROSION AND INSTALLED DOUBLER PER SRM…
- 19 Jan 2001
Skin, corroded
TUL - FOUND CORROSION ON BOTTOM OF CENTER WING SKIN ABOVE LEFT AND RIGHT HEAT EC4. REMOVED CORROSION AND INSTALLED TWO 2024T3-.080 TRIPLERS, ONE SET BETWEEN…
- 19 Jan 2001
Angle, corroded
TUL - FOUND AIRCRAFT CARGO DOOR AFT CUTOUT THRESHOLD LOWER CHORD ANGLE CORRODED FORWARD CORNER BETWEEN STATION 950D AND 950E. REPAIRED PER ESO11697 DATED…
- 19 Jan 2001
Floorbeam, corroded
TUL - FOUND CORROSION ON TOP OF FORWARD UPPER CHORD OF FS 1130 FLOORBEAM LBL 26-60. BLENDED OUT CORROSION AND INSTALLED REPAIR STRAP PER AARD 53-10-07-1. (M)
- 18 Jan 2001
Blade, cracked
TUL - FOUND NR 1 ENGINE FAN BLADE CRACKED AT FIR TREE AS VIEWED FROM AFT SIDE OF DISH. REMOVED AND REPLACED FAN ASSY PER WORK CARD 11-17. (M)
- 18 Jan 2001
Skin, corroded
TUL - FOUND CORROSION ON TOP SKIN SURFACE. REMOVED CORROSION AND INSTALLED REPAIR STRAP PER ESO 11697 DATED 1-15-2001. (M)
- 18 Jan 2001
Skin, corroded
TUL - FOUND CORROSION ON SKIN SURFACE. REMOVED CORROSION AND INSTALLED HI-LOK WITH WASHER PER ESO 11697 DATED 1-16-01. (M)
- 17 Jan 2001
Lap Joint, corroded
TUL - FOUND STRINGER 26L SKIN LAP 4 INCH LONG AREA BULGING AT RIVETS STATION 661-665. FOUND CORROSION IN SKIN LAP. CUT OUT CORRODED AREA AND INSTALLED DOUBLER…
- 17 Nov 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT COCKPIT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT COCKPIT. SYSTEM GROUND CHECKED…
- 17 Nov 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AIR STAIR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT AIR STAIR. SYSTEM GROUND CHECKED…
- 17 Nov 2000
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, CABIN FLOOR PATH EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED CABIN FLOOR PATH EMERGENCY EXIT LIGHT STRIP. SYSTEM GROUND…
- 12 Aug 2000
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS IN AFT CABIN INOPERATIVE. REPAIRED LIGHT STRIP WIRE IN AFT AREA. SYSTEM GROUND CHECK…
- 2 Aug 2000
Wire, broken
DFW DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS AT ROW 15 AND FORWARD OF OVERWING EXIT MARKERS INOPERATIVE. REPAIRED LIGHT STRIP WIRE…
- 20 May 2000
Connector, defective
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT AT SEATS 27 TO 28 ON RIGHT SIDE INOPERATIVE. REPLACED BAD CONNECTOR AT SEAT 27. SYSTEM…
- 19 Apr 2000
Floorbeam, corroded
TUL - CORROSION AROUND NUTPLATES ON FLOORBEAM 1070 LOWER FORWARD FLANGE FROM LBL 15 TO RBL 20. INSTALLED STRAP ON FLOORBEAM PER ESO 11697 DATED 4-11-00. (X)
- 10 Apr 2000
Light, malfunctioned
TUL - FOUND MAIN EMERGENCY ESCAPE PATH MARKING LIGHT HARNESS DIM. INSTALLED NEW EPM FLAT CONDUCTOR A3-06-0720-101 BETWEEN STATION 1030-1090. OP CHECKED LIGHT,…
- 28 Mar 2000
Light, inoperative
MIA - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS AFT OF REAR GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT STRIP AFT OF…
- 21 Dec 1999
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EXTERIOR EMERGENCY EXIT L1 DOOR LIGHT INOPERATIVE. REPLACED EXTERIOR EMERGENCY EXIT L1 DOOR LIGHT. SYSTEM GROUND CHECK…
- 23 Nov 1999
Casting, corroded
TUL - HORIZONTAL STABILIZER HINGE LUGS RIGHT SIDE, BOTH INBOARD AND OUTBOARD HAS CORROSION. REMOVED CORROSION PER SRM 55-10-2. FABRICATED NEW BUSHING PER…
- 23 Nov 1999
Casting, corroded
TUL - HORIZONTAL STABILROSION ON BORES, LEFT SIDE. REMOVED CORROSION ER SRM 55-10-2 AND FABRICATED NEW BUSHING PER 55-10-2. TST: 72,812.33 HOURS. CYCLES:…
- 23 Nov 1999
Casting, corroded
TUL - VERTICAL FIN - HORIZONTAL STABILIZER ATTACH LUGS HAD CORROSION IN BORE, BOTH LEFT AND RIGHT. REMOVED CORROSION ON RIGHT LUG PER SB 727-55-7 AND SRM…
- 21 Nov 1999
Beam, corroded
TUL - HEAVY CORROSION ON TOP OF LEFT HORIZONTAL STABILIZER UPPER REAR T/E BEAM. INSTALLED DOUBLER OVER DAMAGED AREA PER 55-10-6. TST: 72,812 HOURS. CYCLES:…
- 19 Nov 1999
Skin, corroded
TUL - CORROSION ON BILGE SIDE OF SKIN OUTBOARD OF STR 28L STA 572 - STA 580. INSTALLED EXTERNAL DOUBLER PER SRO 53-30-3. TST: 72,812.33 HOURS. CYCLES: 47,830.…
- 17 Nov 1999
Angle, corroded
TUL - HEAVY CORROSION ON STRUCTURE NOSE WHEELWELL JUST OUTBOARD OF LEFT TRUNNION CAP S70 208 WL 178 LBL 20-23. REMOVED/TREATED CORROSION, INSTALLED DOUBLER…
- 4 Jul 1999
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, RIGHT EMERGENCY EXIT FLOOR PATH LIGHTING BY AFT DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT ASSEMBLY.…
- 17 Nov 1998
Turbine, failed
MIA - FLT T1301 - EN ROUTE MIA/EWR AFTER TAKEOFF ABOUT 1,600 FEET LOST POWER, DUMPED FUEL, AND RETURNED AND LANDED MIA WITHOUT FURTHER INCIDENT. REPLACED NR 1…
- 9 May 1998
Light, malfunctioned
DFW - DURNIG OVERNIGHT MAINTENANCE, AFT EMERGENCY EXIT LIGHT IS BLINKING OFF AND ON. REPLACED AFT AIRSTAIR EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL…
- 9 May 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST…
- 18 Dec 1997
Bulkhead Web, corroded
TUL - BS 178 WL 195-197, CORROSION ON BULKHEAD WEB ABOVE HORIZONTAL ANGLE. INSTALLED DOUBLER PER SRM 53-10-9. (M)
- 14 Dec 1997
Frame, dented
TUL - STATION 600, STRINGER 25L AND 24L, TOP FLANGE OF BELTFRAME DENTED, BULGING SIDE OF FRAME BETWEEN 24L AND 25L, DEEPLY DENTED OVER OUTBOARD EDGE OF 24L IN…
- 11 Dec 1997
Frame, dented
TUL - FOUND STATIONS 520, STRINGER 25R TO 21R, BELT FRAME HAS NUMEROUS DEEP DENTS, CREASED INTO RADIUS. FABRICATED AND INSTALLED REPAIR ON FRAME PER SRM…
- 11 Dec 1997
Keel Beam Web, cracked
TUL - BS 870-874, RBL 6, WL 155-161, RIGHT KEEL BEAM WEB CRACKED AROUND NUMEROUS FASTENERS THROUGH 870 TO KEEL BEAM CHORD ANGLE REPAIR. REMOVED DOUBLER ON…
- 10 Dec 1997
Frame, corrosion
TUL - FOUND CORROSION AT SCREW HOLES AND LOWER FLOORBEAM LOWER CAP. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER SRM 51-10-6 AND ESO 11697, DATED…
- 9 Dec 1997
Frame, dented
TUL - STATION 520, STRINGER 23L, BELTFRAME DEEPLY DENTED. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-3. (M)
- 6 Dec 1997
Frame, dented
TUL - STATION 580, STRINGER 25L TO 23L, BELTFRAME UPPER FLANGE DENTED, DENT AT 23L HAS CREASED RADIUS, DENT AT 25L HAS DENTED DOUBLER AT SPLICE. REMOVED…
- 3 Dec 1997
Splice, cracked
TUL - STRINGER SPLICE 21 RIGHT AT STATION 438 CRACKED. REPLACED STRINGER SPLICE PER SRM 53-30-3. (M)
- 3 Dec 1997
Frame, gouged
TUL - BELT FRAME STATION 783 DEEP TOOLING MARK BETWEEN STRINGERS 2 AND 3 RIGHT. INSTALLED DOUBLER ON BELTFRAME PER SRM 51-40-3. (M)
- 3 Dec 1997
Stringer, dented
TUL - FOUND STRINGER DENTED AT ATTACH POINT TO SKIN STATION 465 STRINGER 22L, DYE CHECKED FOUND TO BE CRACKED. CUT OUT DAMAGED SECTION OF STRINGER FABRICATED…
- 3 Dec 1997
Frame, dented
TUL - STATION 660, STRINGER 24R, BELTFRAME UPPER FLANGE DENTED, INCLUSIVE OF DEFORMATION TO VERTICLE FLANGE BEING BULGED BY DENT. REMOVED DAMAGED SECTION OF…
- 3 Dec 1997
Frame, dented
TUL - STATION 500 STRINGER 21R TO 20R, BELTFRAME UPPER FLANGE DENTED WITH CREASE INTO RADIUS. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED DOUBLER PER…
- 3 Dec 1997
Frame, dented
TUL - STATION 500, BELT FRAME DENTED ABOVE PREVIOUS REPAIR, ABOVE STRINGER 22R. REMOVED PREVIOUS REPAIR, FABRICATED AND INSTALLED NEW DOUBLER PER SRM 51-40-3.…
- 3 Dec 1997
Stringer, cracked
TUL - LEFT WING UPPER AFT STRINGER CRACKED AT JUNCTION WITH WS 656 RIB. STOP DRILLED AND INST REPAIR ANGLES PER SB 727-57A159 REV 5. (M)
- 7 Nov 1997
Frame, dented
TUL - STATION 660, STRINGER 24L TO 23L, BELTFRAME DENTED IN RADIUS, BOTH AREAS. REMOVED DAMAGE ON BELTFRAME PER SRM 51-40-3. FABRICATED AND INSTALLED DOUBLER…
- 7 Nov 1997
Frame, dented
TUL - STATION 720, STRINGER 246, BELTFRAME DENTED UPPER FLANGE. INSTALLED DOUBLER PER SRM 51-40-3. (M)
- 7 Nov 1997
Frame, damaged
TUL - STATION 700, STRINGER 23R, PREVIOUS REPAIR ON BELTFRAME HAS SLOTS CUT TO FACILITATE BEND UP TO FIT FRAME, THERE IS ONLY ONE ROW OF FASTENERS ON OUTER…
- 7 Nov 1997
Frame, dented
TUL - STATION 700, STRINGER 24R, BELTFRAME DENTED ON UPPER FLANGE, INTO RADIUS AND FORWARD FLANGE. REMOVED DAMAGE OF BELTFRAME STATION 700 PER SRM 51-40-3,…
- 6 Nov 1997
Frame, dented
TUL - STATION 560, STRINGER 25L TO 23L, BELTFRAME HAS NUMEROUS DENTS IN UPPER FLANGE. REMOVED DAMAGE PER SRM 51-40-3, FABRICATED DOUBLER AND INSTALLED PER SRM…
- 21 Aug 1997
Detector, defective
MIA - FLT 2103 - AFTER TAKEOFF MIA DURING CLIMB-OUT, NR 1 ENGINE STRUT OVERHEAT INDICATION FLICKERED. ACCOMPLISHED ABNORMAL PROCEDURE AND PRECAUTIONARY…
- 6 Apr 1997
Wire, loose
DFW - FLT 0554 - AFTER TAKEOFF DFW DURING INITIAL CLIMB-OUT, LOUD VIBRATION OCCURRED ACCOMPANIED BY HIGH EGT AND DECREASING RPM IN NR 2 ENGINE. ACCOMPLISHED…
- 7 Mar 1997
Skin, corroded
AFW - FOUND SKIN CORRODED AND MOUNT HOLE REAMED TO .783. REPAIR SKIN AND MOUNT HOLE PER MRB 727-0029. (M)
- 7 Mar 1997
Flap Track, corroded
AFW - FOUND CORROSION AT MOUNT HOLES. REWORK WITHOUT CAD PLATE NICKLE STRIKE. REWORK MOUNT HOLES PER MRB 727-0030. (M)
- 5 Mar 1997
Shear Tie, corroded
AFW - FOUND SHEAR TIE CORRODED. REINSTALLED NEW SHEAR TIE USING SAME FASTENER LOCATIONS AS ORIGINAL PER SRM CHAP 51. (M)
- 5 Mar 1997
Stringer, corroded
AFW - FOUND CORROSION IN STRINGER 28R AT STATION 484. REMOVED CORRODED SPLICE AND INSTALL SPLICE PER SRM 53-10-3. (M)
- 5 Mar 1997
Stringer, corroded
AFW - FOUND CORRODED STRINGER AT 26L STATION 708. INSTALLED REPAIR SECTION AS PER SRM 53-10-08. (M)
- 2 Jan 1997
Frame, cracked
TUL - FOUND STUB FRAME CRACKED THROUGH HOLE, STATION 825. INSTALLED DOUBLER PER SRM 51-40-2 FIG 1A, PAGE 6B. (M)
- 23 Dec 1994
Splice, corroded
REPAIR SPLICE CORRODED, 1 INCH BY 3 INCH AT STA 499-501, STR 27R. INSTALLED REPLACEMENT STR SECTION. STR REPAIR PER 53-10-3 FIG 1. (W)
- 23 Dec 1994
Skin, corroded
SKIN CORRODED 2 INCHES AT SKIN LAP, ON TOP SIDE OF STR 26R, STA 692-694. INSTALLED DOUBLER AT STA 692-694 STR 26R PER SRM 53-30-3 PG 23. (W)
- 23 Dec 1994
Skin, corroded
SKIN BULGED AND CORRODED WITH CRACKED FASTENER HEADS BETWEEN EXISTING DOUBLERS AT STR 27R, STA 500. CUT OUT CORRODED AREA AND INSTALLED DOUBLER AND TRIPLER…