service difficulty reports
54 reports
- 18 May 2013
Ballast, failed
F/A REPORTED ELECTRICAL ODOR NEAR AFT GALLEY. EMERGENCY DECLARED, AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. FOUND AFT OVERHEAD GALLEY LIGHT…
- 26 Feb 2013
Strap, cracked
CENTER STRAP UNDER FRAME AT STATION 377 IS CRACKED. ACCOMPLISHED NESTED ANGLE REPAIR PER SRM 53-10-51-2R-1.
- 27 Feb 2012
Transmitter, inoperative
DEN - INFLIGHT JFK-EGE. CREW REPORTED FLAP SPLIT INDICATION. EMERGENCY DECLARED FLIGHT DIVERTED DEN LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE.…
- 6 Oct 2011
Floorbeam, corroded
FLOORBEAM STATION 1640 HAS SEVERAL AREAS OF CORROSION TOP AND BOTTOM SIDE AROUND HOLES. CUT OUT DAMAGE AND INSTALLED T-CAP AND SPLICE STA 1640 PER BOEING…
- 4 Oct 2011
Doubler, corroded
AFT DECK SEVERAL AREAS OF CORROSION STATIONS 1710 TO 1720 FROM STRINGERS 17 LEFT TO 17 RIGHT. REMOVED OLD MULTIPLE DOUBLER, AND INSTALLED ONE LARGER REPAIR…
- 3 Oct 2011
Fitting, corroded
CORROSION ON LAVATORY TIE DOWN AT STATION 1640 AT LC 25. REPLACED LAVATORY FLOOR FITTING PER SRM 51-10-02-0G.
- 2 Oct 2011
Channel, corroded
CABIN FLOOR SUPPORT HAT CHANNEL CORRODED. REPLACED CHANNEL IAW SRM 51-10-02-0G.
- 1 Oct 2011
Angle, corroded
AFT GALLEY DECK PLATE Z ANGLE STRUCTURE TOP OF DECK STATIONS 1680 TO 1720 LEFT SIDE CORRODED. Z-ANGLE INSTALLED PER AARD 51-10-05-1.
- 1 Oct 2011
Doubler, corroded
CORROSION ON DOUBLER FORWARD OF RIGHT GALLEY MOUNT. INSTALLED NEW DOUBLER PER SRM 53-60-51-2R.
- 30 Sep 2011
Angle, corroded
CABIN, Z ANGLE STRUCTURE TOP OF DECK STATIONS 1680 TO 1720 ON RIGHT SIDE CORRODED. INSTALLED NEW Z ANGLE PER SRM 51-10-02-0G AND SRM 51-40-02-0G.
- 30 Sep 2011
Channel, corroded
HAT CHANNEL ON AFT DECK AT FRAME STATION 1680 TO 1710 CORRODED AROUND FASTENER HOLE. INSTALLED AFT CENTER HAT CHANNEL PER SRM 51-10-02-0G.
- 30 Sep 2011
Mount, corroded
RIGHT FORWARD GALLEY MOUNT IN AFT GALLEY AREA CORRODED. INSTALLED NEW MOUNT PER SRM 51-10-02-0G.
- 30 Sep 2011
Mount, corroded
RIGHT AFT GALLEY MOUNT IN AFT GALLEY AREA CORRODED. INSTALLED NEW MOUNT PER SRM 51-10-02-0G.
- 29 Sep 2011
Skin, damaged
ACCIDENTAL IMPACT AT STATION 1844 STRINGER 2 LEFT. ACCOMPLISHED DOUBLER REPAIR PER AT STATION 1844 PER SRM 53-00-01-2R-3.
- 26 Sep 2011
Mount, corroded
G1B GALLEY, AFT OUTBOARD MOUNT IS CORRODED. INSTALLED A NEW G1B GALLEY MOUNT PER SRM 51-10-02-0G, PARAGRAPH 9.
- 26 Sep 2011
Angle, cracked
CENTER INTERCOSTAL FLOORBOARD SUPPORT ANGLE CRACKED STATIONS 1520 TO 1540. REMOVED AND INSTALLED NEW SUPPORT ANGLE AT STATIONS 1520 TO 1540 PER SRM 51-10-02-0G.
- 23 Sep 2011
Mount, corroded
IN THE CABIN AT STATION 375 THE GALLEY MOUNT FORWARD END IS CORRODED, RIGHT BUTTLINE 11. INSTALLED NEW GALLEY MOUNT PER SRM 51-10-02-0G.
- 21 Sep 2011
Mount, corroded
MID LAVATORY MOUNT AFT INBOARD CORRODED. REPLACED MOUNT PER SRM 51-10-02-0G.
- 21 Sep 2011
Mount, corroded
MID LAVATORY MOUNT AFT OUTBOARD CORRODED. REPLACED MOUNT PER SRM 51-10-02-0G.
- 14 Oct 2010
Light, inoperative
PATHWAY EMERGENCY LIGHT AT SEAT 20D IS INOPERATIVE. REPLACED LAMP FOR PATHWAY EMERGENCY LIGHT AT SEAT 20D. OPS CHECKS NORMAL.
- 14 Oct 2010
Light, inoperative
EMERGENCY LIGHT ON EXTERIOR SIDE OF RIGHT NUMBER DOOR 1 IS INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT ON EXTERIOR SIDE OF RIGHT NUMBER 1 DOOR. OPS CHECKS…
- 14 Oct 2010
Light, inoperative
EMERGENCY LIGHT ABOVE SEAT 13ABC IS INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT ABOVE SEAT 13ABC. OPS CHECKS NORMAL.
- 12 Jan 2010
Light, inoperative
EXTERNAL EMERGENCY LIGHT AT RIGHT AFT OVERWING INOPERATIVE. REPLACED LAMP.
- 12 Jan 2010
Light, inoperative
EXTERNAL EMERGENCY LIGHT AT LEFT FORWARD OVERWING INOPERATIVE. REPLACED LAMP.
- 31 Dec 2009
Light, broken
THE 20DEF EMERGENCY LIGHT IS BROKEN. REPLACED LIGHT ASSEMBLY FOR 20DEF EMERGENCY LIGHT. OPS CHECKS NORMAL.
- 5 Mar 2009
Module, defective
LAS - SEAT MOUNTED EMERGENCY PATH LIGHTS FROM SEATS 9D TO 15D WILL NOT ILLUMINATE. REPLACED DEFECTIVE MODULE.
- 5 Mar 2009
Battery Pack, discharged
LAS - SEAT MOUNTED EMERGENCY LIGHTS FROM SEAT 9D TO 15D WILL NOT ILLUMINATE. REPLACED BATTERY PACK.
- 2 Jun 2008
Lamp, inoperative
DFW - EXTERIOR EMERGENCY LIGHT AT LT NR ONE DOOR INOPERATIVE. REPLACED LAMP FOR EXTERIOR EMERGENCY LIGHT AT LT NR ONE DOOR. SYSTEM GROUND CHECKED NORMAL…
- 2 Jun 2008
Battery Pack, inoperative
DFW - EMERGENCY LIGHT EXIT SIGN AT OVERHEAD MID LAVATORY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT EXIT SIGN AT OVERHEAD MID LAVATORY. SYSTEM…
- 2 Jun 2008
Lamp, inoperative
DFW - EMERGENCY LIGHT AT SEAT 36D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 36D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)
- 2 Jun 2008
Light, dirty
DFW - EXTERIOR EMERGENCY LIGHT AT RT NR FOUR DOOR INOPERATIVE. CLEANED AND SECURED LIGHT ASSEMBLY FOR EXTERIOR EMERGENCY LIGHT AT RT NR FOUR DOOR. SYSTEM…
- 2 Jun 2008
Battery Pack, inoperative
DFW - EMERGENCY LIGHT EXIT SIGN AT OVERHEAD RT NR ONE DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT EXIT SIGN AT OVERHEAD RT NR ONE DOOR. SYSTEM…
- 17 May 2008
Battery Pack, discharged
MIA EMERGENCY LIGHT AT RT NUMBER THREE DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT RT NUMBER THREE DOOR. SYSTEM GROUND CHECKED NORMAL…
- 17 May 2008
Battery Pack, discharged
MIA EMERGENCY LIGHT AT SEAT ROW 26 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT SEAT ROW 26. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED) (A)
- 14 Mar 2008
Battery Pack, inoperative
DFW - EXTERIOR EMERGENCY LIGHT AT LEFT NUMBER ONE DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EXTERIOR EMERGENCY LIGHT AT LEFT NUMBER ONE DOOR. SYSTEM GROUND…
- 9 Feb 2008
Indicator, tripped
JFK INFLIGHT T1876/09FEB MIA TO LGA - CREW REPORTED FLAP FAULT DURING DEPLOYMENT. TRAILING EDGE DISAGREE INDICATION. EXTENDED FLAPS WITH ALTERNATE SYSTEM.…
- 21 Jan 2008
Lamp, inoperative
DFW - EMERGENCY LIGHT AT RIGHT NUMBER THREE DOOR INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT RIGHT NUMBER THREE DOOR. SYSTEM GROUND CHECKED NORMAL…
- 29 Sep 2007
Connector, loose
MIA - EMERGENCY LIGHT AT SEAT 5E INOPERATIVE. RESEATED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 29 Sep 2007
Bulb, broken
MIA - EMERGENCY LIGHT AT LEFT NUMBER THREE DOOR BROKEN. REPLACED LAMP FOR EMERGENCY LIGHT AT LEFT NUMBER THREE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 26 May 2007
Battery Pack, inoperative
MIA - EMERGENCY LIGHT AT SEAT ROW 26 INOPERATIVE. REPLACED LEFT BATTERY PACK FOR EMERGENCY LIGHT AT SEAT ROW 26. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 2 Jan 2007
Connector, loose
MIA - EMERGENCY LIGHT AT SEAT 36D INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 36D. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 12 Mar 2005
Governor, inoperative
FLL INFLIGHT T2369/12MAR RIGHT HAND ENGINE PARAMETER FLUCTUATIONS. RETURNED TO FLL AND LANDED WITHOUT INCIDENT. REPLACED RIGHT ENGINE FUEL FLOW GOVERNOR AND…
- 2 Jun 2004
Skin, damaged
TUL - REPAIR OF TEMPORARY REPAIR OF FUSELAGE SKIN AT STRINGER 26L TO 27L AT STATION 500. CUT OUT AREA WAS 4.5 INCHES BY 6.25 INCHES. REPAIRED TEMPORARY REPAIR…
- 19 Nov 2003
Connector, loose
MIA AFT CARGO DOOR EMERGENCY LIGHT INOPERATIVE. FOUND CONNECTOR DISCONNECTED AT BATTERY PACK. REPOSITIONED AND SECURED CONNECTOR. SYSTEM GROUND CHECKED NORMAL…
- 26 Sep 2003
Connector, loose
MIA - OVERNIGHT MAINTENANCE OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT 20D. REINSTALLED LOOSE CONNECTION. SYSTEM GROUND CHECKED NORMAL…
- 5 May 2003
Light, inoperative
DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGTHS AT SEAT 1E INOPERATIVE. REPLACED EMEREGNCY EXIT SEAT LIGHT AT 1E. SYSTEM GROUND CHECKED NORMAL…
- 6 Jan 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT FLOOR PATH STRIP. SYSTEM GROUND CHECKED NORMAL…
- 18 Nov 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, MAIN CABIN FLOOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT STRIP AT MAIN CABIN FLOOR. SYSTEM GROUND…
- 18 Mar 2000
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING FROM ROW 15 TO 17, AND 34 INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT WIRE.…
- 24 Feb 2000
Wire, damaged
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE FLOOR PATH LIGHTS IN FIRST CLASS INOPERATIVE. REPAIRED WIRING. SYSTEM GROUND CHECK NORMAL OPERATION.…
- 16 Feb 2000
Connector, damaged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE FLOOR PATH LIGHTS INFORWARD COACH AREA INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE FLOOR PATH LIGHTS…
- 27 Jan 2000
Light, inoperative
MIA - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT FLOOR PATH LIGHTS AT SEAT 26D AND 34D INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT…
- 21 Aug 1999
Wire, loose
ORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING STRIPS FROM SEAT 9D TO SEAT 17D INOPERATIVE. RE-SECURED WIRE TO EMERGENCY EXIT FLOOR…
- 6 Aug 1999
Bottle, failed test
MEX - DURING OVERNIGHT MAINTENANCE, EMERGENCY OVERWING SLIDE BOTTLE WOULD NOT TEST FROM CABIN. PLACARDED LEFT OVERWING BOTTLE 'TEST INOP' PER MEL. REPLACED…